Merge "Gate at RST line length of 79 chars"
This commit is contained in:
commit
cf8230a80b
@ -289,8 +289,9 @@ including ensuring a set of instances run on different compute nodes for
|
||||
service resiliency or on the same node for high performance
|
||||
inter-instance communications.
|
||||
|
||||
Administrative users can specify which compute node their instances run
|
||||
on. To do this, specify the ``--availability-zone AVAILABILITY_ZONE:COMPUTE_HOST`` parameter.
|
||||
Administrative users can specify which compute node their instances
|
||||
run on. To do this, specify the ``--availability-zone
|
||||
AVAILABILITY_ZONE:COMPUTE_HOST`` parameter.
|
||||
|
||||
.. |Base image state with no running instances| image:: ../../common/figures/instance-life-1.png
|
||||
.. |Instance creation from image and runtime state| image:: ../../common/figures/instance-life-2.png
|
||||
|
@ -165,9 +165,9 @@ in ``self.logger``, has these new methods:
|
||||
"proxy-server.Container", or "proxy-server.Object" as soon as the
|
||||
Controller object is determined and instantiated for the request.
|
||||
|
||||
- ``update_stats(self, metric, amount, sample_rate=1)`` Increments the supplied
|
||||
meter by the given amount. This is used when you need to add or
|
||||
subtract more that one from a counter, like incrementing
|
||||
- ``update_stats(self, metric, amount, sample_rate=1)`` Increments
|
||||
the supplied meter by the given amount. This is used when you need
|
||||
to add or subtract more that one from a counter, like incrementing
|
||||
"suffix.hashes" by the number of computed hashes in the object
|
||||
replicator.
|
||||
|
||||
@ -177,11 +177,12 @@ in ``self.logger``, has these new methods:
|
||||
- ``decrement(self, metric, sample_rate=1)`` Lowers the given counter
|
||||
meter by one.
|
||||
|
||||
- ``timing(self, metric, timing_ms, sample_rate=1)`` Record that the given meter
|
||||
took the supplied number of milliseconds.
|
||||
- ``timing(self, metric, timing_ms, sample_rate=1)`` Record that the
|
||||
given meter took the supplied number of milliseconds.
|
||||
|
||||
- ``timing_since(self, metric, orig_time, sample_rate=1)`` Convenience method to record
|
||||
a timing meter whose value is "now" minus an existing timestamp.
|
||||
- ``timing_since(self, metric, orig_time, sample_rate=1)``
|
||||
Convenience method to record a timing meter whose value is "now"
|
||||
minus an existing timestamp.
|
||||
|
||||
Note that these logging methods may safely be called anywhere you have a
|
||||
logger object. If StatsD logging has not been configured, the methods
|
||||
|
@ -2,71 +2,62 @@
|
||||
Features and benefits
|
||||
=====================
|
||||
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Features | Benefits |
|
||||
+=============================+==================================================+
|
||||
| Leverages commodity | No lock-in, lower price/GB. |
|
||||
| hardware | |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| HDD/node failure agnostic | Self-healing, reliable, data redundancy protects |
|
||||
| | from failures. |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Unlimited storage | Large and flat namespace, highly scalable |
|
||||
| | read/write access, able to serve content |
|
||||
| | directly from storage system. |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Multi-dimensional | Scale-out architecture: Scale vertically and |
|
||||
| scalability | horizontally-distributed storage. Backs up |
|
||||
| | and archives large amounts of data with |
|
||||
| | linear performance. |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Account/container/object | No nesting, not a traditional file system: |
|
||||
| structure | Optimized for scale, it scales to multiple |
|
||||
| | petabytes and billions of objects. |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Built-in replication | A configurable number of accounts, containers |
|
||||
| 3✕ + data redundancy | and object copies for high availability. |
|
||||
| (compared with 2✕ on RAID) | |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Easily add capacity (unlike | Elastic data scaling with ease |
|
||||
| RAID resize) | |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| No central database | Higher performance, no bottlenecks |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| RAID not required | Handle many small, random reads and writes |
|
||||
| | efficiently |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Built-in management | Account management: Create, add, verify, |
|
||||
| utilities | and delete users; Container management: Upload, |
|
||||
| | download, and verify; Monitoring: Capacity, |
|
||||
| | host, network, log trawling, and cluster health. |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Drive auditing | Detect drive failures preempting data corruption |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Expiring objects | Users can set an expiration time or a TTL on an |
|
||||
| | object to control access |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Direct object access | Enable direct browser access to content, such as |
|
||||
| | for a control panel |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Realtime visibility into | Know what users are requesting. |
|
||||
| client requests | |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Supports S3 API | Utilize tools that were designed for the popular |
|
||||
| | S3 API. |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Restrict containers per | Limit access to control usage by user. |
|
||||
| account | |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Support for NetApp, | Unified support for block volumes using a |
|
||||
| Nexenta, SolidFire | variety of storage systems. |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Snapshot and backup API for | Data protection and recovery for VM data. |
|
||||
| block volumes | |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Standalone volume API | Separate endpoint and API for integration with |
|
||||
| available | other compute systems. |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
| Integration with Compute | Fully integrated with Compute for attaching |
|
||||
| | block volumes and reporting on usage. |
|
||||
+-----------------------------+--------------------------------------------------+
|
||||
.. list-table::
|
||||
:header-rows: 1
|
||||
:widths: 10 40
|
||||
|
||||
* - Features
|
||||
- Benefits
|
||||
* - Leverages commodity hardware
|
||||
- No lock-in, lower price/GB.
|
||||
* - HDD/node failure agnostic
|
||||
- Self-healing, reliable, data redundancy protects from failures.
|
||||
* - Unlimited storage
|
||||
- Large and flat namespace, highly scalable read/write access,
|
||||
able to serve content directly from storage system.
|
||||
* - Multi-dimensional scalability
|
||||
- Scale-out architecture: Scale vertically and
|
||||
horizontally-distributed storage. Backs up and archives large
|
||||
amounts of data with linear performance.
|
||||
* - Account/container/object structure
|
||||
- No nesting, not a traditional file system: Optimized for scale,
|
||||
it scales to multiple petabytes and billions of objects.
|
||||
* - Built-in replication 3✕ + data redundancy (compared with 2✕ on
|
||||
RAID)
|
||||
- A configurable number of accounts, containers and object copies
|
||||
for high availability.
|
||||
* - Easily add capacity (unlike RAID resize)
|
||||
- Elastic data scaling with ease .
|
||||
* - No central database
|
||||
- Higher performance, no bottlenecks.
|
||||
* - RAID not required
|
||||
- Handle many small, random reads and writes efficiently.
|
||||
* - Built-in management utilities
|
||||
- Account management: Create, add, verify, and delete users;
|
||||
Container management: Upload, download, and verify; Monitoring:
|
||||
Capacity, host, network, log trawling, and cluster health.
|
||||
* - Drive auditing
|
||||
- Detect drive failures preempting data corruption.
|
||||
* - Expiring objects
|
||||
- Users can set an expiration time or a TTL on an object to
|
||||
control access.
|
||||
* - Direct object access
|
||||
- Enable direct browser access to content, such as for a control
|
||||
panel.
|
||||
* - Realtime visibility into client requests
|
||||
- Know what users are requesting.
|
||||
* - Supports S3 API
|
||||
- Utilize tools that were designed for the popular S3 API.
|
||||
* - Restrict containers per account
|
||||
- Limit access to control usage by user.
|
||||
* - Support for NetApp, Nexenta, Solidfire
|
||||
- Unified support for block volumes using a variety of storage
|
||||
systems.
|
||||
* - Snapshot and backup API for block volumes.
|
||||
- Data protection and recovery for VM data.
|
||||
* - Standalone volume API available
|
||||
- Separate endpoint and API for integration with other compute
|
||||
systems.
|
||||
* - Integration with Compute
|
||||
- Fully integrated with Compute for attaching block volumes and
|
||||
reporting on usage.
|
||||
|
@ -14,7 +14,8 @@ created image:
|
||||
|
||||
**To configure tenant-specific image locations**
|
||||
|
||||
#. Configure swift as your ``default_store`` in the :file:`glance-api.conf` file.
|
||||
#. Configure swift as your ``default_store`` in the
|
||||
:file:`glance-api.conf` file.
|
||||
|
||||
#. Set these configuration options in the :file:`glance-api.conf` file:
|
||||
|
||||
|
@ -70,8 +70,8 @@ This example creates a my-new-volume volume based on an image.
|
||||
| nova | available |
|
||||
+------+-----------+
|
||||
|
||||
#. Create a volume with 8 gibibytes (GiB) of space, and specify the availability zone
|
||||
and image::
|
||||
#. Create a volume with 8 gibibytes (GiB) of space, and specify the
|
||||
availability zone and image::
|
||||
|
||||
$ cinder create 8 --display-name my-new-volume --image-id 397e713c-b95b-4186-ad46-6126863ea0a9 --availability-zone nova
|
||||
|
||||
|
@ -361,8 +361,8 @@ The following steps involve compute node 1.
|
||||
#. Security group rules (6) on the tunnel bridge ``qbr`` handle firewalling
|
||||
and state tracking for the packet.
|
||||
|
||||
#. The tunnel bridge ``qbr`` forwards the packet to the ``tap`` interface (7)
|
||||
on instance 1.
|
||||
#. The tunnel bridge ``qbr`` forwards the packet to the ``tap``
|
||||
interface (7) on instance 1.
|
||||
|
||||
#. For VLAN tenant networks:
|
||||
|
||||
@ -435,8 +435,8 @@ The following steps involve compute node 1:
|
||||
bridge ``qbr``. The packet contains destination MAC address *TG1*
|
||||
because the destination resides on another network.
|
||||
|
||||
#. Security group rules (2) on the tunnel bridge ``qbr`` handle state tracking
|
||||
for the packet.
|
||||
#. Security group rules (2) on the tunnel bridge ``qbr`` handle
|
||||
state tracking for the packet.
|
||||
|
||||
#. The tunnel bridge ``qbr`` forwards the packet to the logical tunnel
|
||||
interface ``vxlan-sid`` (3) where *sid* contains the tenant network
|
||||
@ -473,9 +473,10 @@ The following steps involve the network node.
|
||||
#. The logical tunnel interface ``vxlan-sid`` forwards the packet to the
|
||||
tunnel bridge ``qbr``.
|
||||
|
||||
#. The tunnel bridge ``qbr`` forwards the packet to the ``qr-1`` interface (5)
|
||||
in the router namespace ``qrouter``. The ``qr-1`` interface contains the
|
||||
tenant network 1 gateway IP address *TG1*.
|
||||
#. The tunnel bridge ``qbr`` forwards the packet to the ``qr-1``
|
||||
interface (5) in the router namespace ``qrouter``. The ``qr-1``
|
||||
interface contains the tenant network 1 gateway IP address
|
||||
*TG1*.
|
||||
|
||||
#. For VLAN tenant networks:
|
||||
|
||||
|
@ -148,7 +148,8 @@ The compute nodes contain the following network components:
|
||||
Packet flow
|
||||
~~~~~~~~~~~
|
||||
|
||||
During normal operation, packet flow with HA routers mirrors the legacy scenario with Linux bridge.
|
||||
During normal operation, packet flow with HA routers mirrors the
|
||||
legacy scenario with Linux bridge.
|
||||
|
||||
Case 1: HA failover operation
|
||||
-----------------------------
|
||||
|
@ -356,8 +356,8 @@ The following steps involve compute node 1:
|
||||
bridge ``qbr``. The packet contains destination MAC address *I2*
|
||||
because the destination resides on the same network.
|
||||
|
||||
#. Security group rules (2) on the provider bridge ``qbr`` handle state tracking
|
||||
for the packet.
|
||||
#. Security group rules (2) on the provider bridge ``qbr`` handle
|
||||
state tracking for the packet.
|
||||
|
||||
#. The Linux bridge ``qbr`` forwards the packet to the Open vSwitch
|
||||
integration bridge ``br-int``.
|
||||
|
@ -335,8 +335,8 @@ The following steps involve compute node 1:
|
||||
bridge ``qbr``. The packet contains destination MAC address *I2*
|
||||
because the destination resides on the same network.
|
||||
|
||||
#. Security group rules (2) on the provider bridge ``qbr`` handle state tracking
|
||||
for the packet.
|
||||
#. Security group rules (2) on the provider bridge ``qbr`` handle
|
||||
state tracking for the packet.
|
||||
|
||||
#. The provider bridge ``qbr`` forwards the packet to the logical VLAN
|
||||
interface ``device.sid`` where *device* references the underlying
|
||||
|
@ -8,35 +8,37 @@ Ethernet
|
||||
Ethernet is a networking protocol, specified by the IEEE 802.3 standard. Most
|
||||
wired network interface cards (NICs) communicate using Ethernet.
|
||||
|
||||
In the `OSI model`_ of networking protocols, Ethernet occupies the second layer,
|
||||
which is known as the data link layer. When discussing Ethernet, you will often
|
||||
hear terms such as *local network*, *layer 2*, *L2*, *link layer* and *data link
|
||||
layer*.
|
||||
In the `OSI model`_ of networking protocols, Ethernet occupies the
|
||||
second layer, which is known as the data link layer. When discussing
|
||||
Ethernet, you will often hear terms such as *local network*, *layer
|
||||
2*, *L2*, *link layer* and *data link layer*.
|
||||
|
||||
In an Ethernet network, the hosts connected to the network communicate by
|
||||
exchanging *frames*, which is the Ethernet terminology for packets. Every host on
|
||||
an Ethernet network is uniquely identified by an address called the media access
|
||||
control (MAC) address. In particular, in an OpenStack environment, every virtual
|
||||
machine instance has a unique MAC address, which is different from the MAC
|
||||
address of the compute host. A MAC address has 48 bits and is typically represented
|
||||
as a hexadecimal string, such as ``08:00:27:b9:88:74``. The MAC address is
|
||||
hard-coded into the NIC by the manufacturer, although modern NICs allow you to change the MAC
|
||||
address programatically. In Linux, you can retrieve the MAC address of a NIC
|
||||
using the ``ip`` command::
|
||||
In an Ethernet network, the hosts connected to the network communicate
|
||||
by exchanging *frames*, which is the Ethernet terminology for packets.
|
||||
Every host on an Ethernet network is uniquely identified by an address
|
||||
called the media access control (MAC) address. In particular, in an
|
||||
OpenStack environment, every virtual machine instance has a unique MAC
|
||||
address, which is different from the MAC address of the compute host.
|
||||
A MAC address has 48 bits and is typically represented as a
|
||||
hexadecimal string, such as ``08:00:27:b9:88:74``. The MAC address is
|
||||
hard-coded into the NIC by the manufacturer, although modern NICs
|
||||
allow you to change the MAC address programatically. In Linux, you can
|
||||
retrieve the MAC address of a NIC using the ``ip`` command::
|
||||
|
||||
$ ip link show eth0
|
||||
2: eth0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast state UP mode DEFAULT group default qlen 1000
|
||||
link/ether 08:00:27:b9:88:74 brd ff:ff:ff:ff:ff:ff
|
||||
|
||||
Conceptually, you can think of an Ethernet network as a single bus that each of the
|
||||
network hosts connects to. In early implementations, an Ethernet
|
||||
network consisted of a single coaxial cable that hosts would tap into to connect
|
||||
to the network. Modern Ethernet networks do not use this approach, and instead
|
||||
each network host connects directly to a network device called a *switch*.
|
||||
Still, this conceptual model is useful, and in network diagrams (including those
|
||||
generated by the OpenStack dashboard) an Ethernet network is often depicted as
|
||||
if it was a single bus. You'll sometimes hear an Ethernet network
|
||||
referred to as a *layer 2 segment*.
|
||||
Conceptually, you can think of an Ethernet network as a single bus
|
||||
that each of the network hosts connects to. In early implementations,
|
||||
an Ethernet network consisted of a single coaxial cable that hosts
|
||||
would tap into to connect to the network. Modern Ethernet networks do
|
||||
not use this approach, and instead each network host connects directly
|
||||
to a network device called a *switch*. Still, this conceptual model is
|
||||
useful, and in network diagrams (including those generated by the
|
||||
OpenStack dashboard) an Ethernet network is often depicted as if it
|
||||
was a single bus. You'll sometimes hear an Ethernet network referred
|
||||
to as a *layer 2 segment*.
|
||||
|
||||
In an Ethernet network, every host on the network can send a frame directly to
|
||||
every other host. An Ethernet network also supports broadcasts, so
|
||||
@ -46,27 +48,30 @@ are two notable protocols that use Ethernet broadcasts. Because Ethernet
|
||||
networks support broadcasts, you will sometimes hear an Ethernet network
|
||||
referred to as a *broadcast domain*.
|
||||
|
||||
When a NIC receives an Ethernet frame, by default the NIC checks to see if the
|
||||
destination MAC address matches the address of the NIC (or the broadcast
|
||||
address), and the Ethernet frame is discarded if the MAC address
|
||||
does not match. For a compute host, this behavior is undesirable because the
|
||||
frame may be intended for one of the instances. NICs can be configured for
|
||||
*promiscuous mode*, where they pass all Ethernet frames to the operating
|
||||
system, even if the MAC address does not match. Compute hosts should always have
|
||||
the appropriate NICs configured for promiscuous mode.
|
||||
When a NIC receives an Ethernet frame, by default the NIC checks to
|
||||
see if the destination MAC address matches the address of the NIC (or
|
||||
the broadcast address), and the Ethernet frame is discarded if the MAC
|
||||
address does not match. For a compute host, this behavior is
|
||||
undesirable because the frame may be intended for one of the
|
||||
instances. NICs can be configured for *promiscuous mode*, where they
|
||||
pass all Ethernet frames to the operating system, even if the MAC
|
||||
address does not match. Compute hosts should always have the
|
||||
appropriate NICs configured for promiscuous mode.
|
||||
|
||||
As mentioned earlier, modern Ethernet networks use switches to interconnect the
|
||||
network hosts. A switch is a box of networking hardware with a large number of ports,
|
||||
that forwards Ethernet frames from one connected host to another. When hosts first send
|
||||
frames over the switch, the switch doesn’t know which MAC address is associated
|
||||
with which port. If an Ethernet frame is destined for an unknown MAC address,
|
||||
the switch broadcasts the frame to all ports. The port learns which MAC addresses are
|
||||
at which ports by observing the traffic. Once it knows which MAC address is
|
||||
associated with a port, it can send Ethernet frames to the correct port instead
|
||||
of broadcasting. The switch maintains the mappings of MAC addresses to switch
|
||||
ports in a table called a *forwarding table* or *forwarding information base*
|
||||
(FIB). Switches can be daisy-chained together, and the resulting connection of
|
||||
switches and hosts behaves like a single network.
|
||||
As mentioned earlier, modern Ethernet networks use switches to
|
||||
interconnect the network hosts. A switch is a box of networking
|
||||
hardware with a large number of ports, that forwards Ethernet frames
|
||||
from one connected host to another. When hosts first send frames over
|
||||
the switch, the switch doesn’t know which MAC address is associated
|
||||
with which port. If an Ethernet frame is destined for an unknown MAC
|
||||
address, the switch broadcasts the frame to all ports. The port learns
|
||||
which MAC addresses are at which ports by observing the traffic. Once
|
||||
it knows which MAC address is associated with a port, it can send
|
||||
Ethernet frames to the correct port instead of broadcasting. The
|
||||
switch maintains the mappings of MAC addresses to switch ports in a
|
||||
table called a *forwarding table* or *forwarding information base*
|
||||
(FIB). Switches can be daisy-chained together, and the resulting
|
||||
connection of switches and hosts behaves like a single network.
|
||||
|
||||
.. _OSI model: http://en.wikipedia.org/wiki/OSI_model
|
||||
|
||||
@ -74,32 +79,35 @@ VLANs
|
||||
~~~~~
|
||||
|
||||
VLAN is a networking technology that enables a single switch to act as
|
||||
if it was multiple independent switches. Specifically, two hosts that are
|
||||
connected to the same switch but on different VLANs do not see each other's
|
||||
traffic. OpenStack is able to take advantage of VLANs to isolate the traffic of
|
||||
different tenants, even if the tenants happen to have instances running on the
|
||||
same compute host. Each VLAN has an associated numerical ID, between 1 and 4095.
|
||||
We say "VLAN 15" to refer to the VLAN with numerical ID of 15.
|
||||
if it was multiple independent switches. Specifically, two hosts that
|
||||
are connected to the same switch but on different VLANs do not see
|
||||
each other's traffic. OpenStack is able to take advantage of VLANs to
|
||||
isolate the traffic of different tenants, even if the tenants happen
|
||||
to have instances running on the same compute host. Each VLAN has an
|
||||
associated numerical ID, between 1 and 4095. We say "VLAN 15" to refer
|
||||
to the VLAN with numerical ID of 15.
|
||||
|
||||
To understand how VLANs work, let's consider VLAN applications in a traditional
|
||||
IT environment, where physical hosts are attached to a physical switch, and no
|
||||
virtualization is involved. Imagine a scenario where you want three isolated
|
||||
networks, but you only have a single physical switch. The network administrator
|
||||
would choose three VLAN IDs, say, 10, 11, and 12, and would configure the switch
|
||||
to associate switchports with VLAN IDs. For example, switchport 2 might be
|
||||
associated with VLAN 10, switchport 3 might be associated with VLAN 11, and so
|
||||
forth. When a switchport is configured for a specific VLAN, it is called an
|
||||
*access port*. The switch is responsible for ensuring that the network traffic
|
||||
is isolated across the VLANs.
|
||||
To understand how VLANs work, let's consider VLAN applications in a
|
||||
traditional IT environment, where physical hosts are attached to a
|
||||
physical switch, and no virtualization is involved. Imagine a scenario
|
||||
where you want three isolated networks, but you only have a single
|
||||
physical switch. The network administrator would choose three VLAN
|
||||
IDs, say, 10, 11, and 12, and would configure the switch to associate
|
||||
switchports with VLAN IDs. For example, switchport 2 might be
|
||||
associated with VLAN 10, switchport 3 might be associated with VLAN
|
||||
11, and so forth. When a switchport is configured for a specific VLAN,
|
||||
it is called an *access port*. The switch is responsible for ensuring
|
||||
that the network traffic is isolated across the VLANs.
|
||||
|
||||
Now consider the scenario that all of the switchports in the first switch become
|
||||
occupied, and so the organization buys a second switch and connects it to the first
|
||||
switch to expand the available number of switchports. The second switch is also
|
||||
configured to support VLAN IDs 10, 11, and 12. Now imagine host A connected to
|
||||
switch 1 on a port configured for VLAN ID 10 sends an Ethernet frame intended
|
||||
for host B connected to switch 2 on a port configured for VLAN ID 10. When switch 1
|
||||
forwards the Ethernet frame to switch 2, it must communicate that the frame is
|
||||
associated with VLAN ID 10.
|
||||
Now consider the scenario that all of the switchports in the first
|
||||
switch become occupied, and so the organization buys a second switch
|
||||
and connects it to the first switch to expand the available number of
|
||||
switchports. The second switch is also configured to support VLAN IDs
|
||||
10, 11, and 12. Now imagine host A connected to switch 1 on a port
|
||||
configured for VLAN ID 10 sends an Ethernet frame intended for host B
|
||||
connected to switch 2 on a port configured for VLAN ID 10. When switch
|
||||
1 forwards the Ethernet frame to switch 2, it must communicate that
|
||||
the frame is associated with VLAN ID 10.
|
||||
|
||||
If two switches are to be connected together, and the switches are configured
|
||||
for VLANs, then the switchports used for cross-connecting the switches must be
|
||||
@ -157,11 +165,12 @@ identifier to all zeros to make reference to a subnet. For example, if
|
||||
a host's IP address is ``10.10.53.24/16``, then we would say the
|
||||
subnet is ``10.10.0.0/16``.
|
||||
|
||||
To understand how ARP translates IP addresses to MAC addresses, consider the
|
||||
following example. Assume host *A* has an IP address of ``192.168.1.5/24`` and a
|
||||
MAC address of ``fc:99:47:49:d4:a0``, and wants to send a packet to host *B*
|
||||
with an IP address of ``192.168.1.7``. Note that the network number is the same
|
||||
for both hosts, so host *A* is able to send frames directly to host *B*.
|
||||
To understand how ARP translates IP addresses to MAC addresses,
|
||||
consider the following example. Assume host *A* has an IP address of
|
||||
``192.168.1.5/24`` and a MAC address of ``fc:99:47:49:d4:a0``, and
|
||||
wants to send a packet to host *B* with an IP address of
|
||||
``192.168.1.7``. Note that the network number is the same for both
|
||||
hosts, so host *A* is able to send frames directly to host *B*.
|
||||
|
||||
The first time host *A* attempts to communicate with host *B*, the
|
||||
destination MAC address is not known. Host *A* makes an ARP request to
|
||||
@ -208,14 +217,15 @@ Protocol (:term:`DHCP`) to dynamically obtain IP addresses. A DHCP
|
||||
server hands out the IP addresses to network hosts, which are the DHCP
|
||||
clients.
|
||||
|
||||
DHCP clients locate the DHCP server by sending a UDP_ packet from port 68 to
|
||||
address ``255.255.255.255`` on port 67. Address ``255.255.255.255`` is the local
|
||||
network broadcast address: all hosts on the local network see the UDP
|
||||
packets sent to this address. However, such packets are not forwarded to
|
||||
other networks. Consequently, the DHCP server must be on the same local network
|
||||
as the client, or the server will not receive the broadcast. The DHCP server
|
||||
responds by sending a UDP packet from port 67 to port 68 on the client. The
|
||||
exchange looks like this:
|
||||
DHCP clients locate the DHCP server by sending a UDP_ packet from port
|
||||
68 to address ``255.255.255.255`` on port 67. Address
|
||||
``255.255.255.255`` is the local network broadcast address: all hosts
|
||||
on the local network see the UDP packets sent to this address.
|
||||
However, such packets are not forwarded to other networks.
|
||||
Consequently, the DHCP server must be on the same local network as the
|
||||
client, or the server will not receive the broadcast. The DHCP server
|
||||
responds by sending a UDP packet from port 67 to port 68 on the
|
||||
client. The exchange looks like this:
|
||||
|
||||
1. The client sends a discover ("I’m a client at MAC address
|
||||
``08:00:27:b9:88:74``, I need an IP address")
|
||||
@ -248,22 +258,22 @@ protocol were carried out for the instance in question.
|
||||
IP
|
||||
~~
|
||||
|
||||
The Internet Protocol (IP) specifies how to route packets between hosts that are
|
||||
connected to different local networks. IP relies on special network hosts
|
||||
called *routers* or *gateways*. A router is a host that is connected to at least
|
||||
two local networks and can forward IP packets from one local network to another.
|
||||
A router has multiple IP addresses: one for each of the networks it is connected
|
||||
to.
|
||||
The Internet Protocol (IP) specifies how to route packets between
|
||||
hosts that are connected to different local networks. IP relies on
|
||||
special network hosts called *routers* or *gateways*. A router is a
|
||||
host that is connected to at least two local networks and can forward
|
||||
IP packets from one local network to another. A router has multiple IP
|
||||
addresses: one for each of the networks it is connected to.
|
||||
|
||||
In the OSI model of networking protocols, IP occupies the third layer, which is
|
||||
known as the network layer. When discussing IP, you will often hear terms such as
|
||||
*layer 3*, *L3*, and *network layer*.
|
||||
In the OSI model of networking protocols, IP occupies the third layer,
|
||||
which is known as the network layer. When discussing IP, you will
|
||||
often hear terms such as *layer 3*, *L3*, and *network layer*.
|
||||
|
||||
A host sending a packet to an IP address consults its *routing table* to
|
||||
determine which machine on the local network(s) the packet should be sent to. The
|
||||
routing table maintains a list of the subnets associated with each local network
|
||||
that the host is directly connected to, as well as a list of routers that are
|
||||
on these local networks.
|
||||
A host sending a packet to an IP address consults its *routing table*
|
||||
to determine which machine on the local network(s) the packet should
|
||||
be sent to. The routing table maintains a list of the subnets
|
||||
associated with each local network that the host is directly connected
|
||||
to, as well as a list of routers that are on these local networks.
|
||||
|
||||
On a Linux machine, any of the following commands displays the routing table::
|
||||
|
||||
@ -279,25 +289,25 @@ Here is an example of output from ``ip route show``::
|
||||
192.168.27.0/24 dev eth1 proto kernel scope link src 192.168.27.100
|
||||
192.168.122.0/24 dev virbr0 proto kernel scope link src 192.168.122.1
|
||||
|
||||
Line 1 of the output specifies the location of the default route, which is the effective
|
||||
routing rule if none of the other rules match. The router associated with the
|
||||
default route (``10.0.2.2`` in the example above) is sometimes referred to as
|
||||
the *default gateway*. A DHCP_ server typically transmits the IP address of the
|
||||
default gateway to the DHCP client along with the client's IP address and
|
||||
a netmask.
|
||||
Line 1 of the output specifies the location of the default route,
|
||||
which is the effective routing rule if none of the other rules match.
|
||||
The router associated with the default route (``10.0.2.2`` in the
|
||||
example above) is sometimes referred to as the *default gateway*. A
|
||||
DHCP_ server typically transmits the IP address of the default gateway
|
||||
to the DHCP client along with the client's IP address and a netmask.
|
||||
|
||||
Line 2 of the output specifies that IPs in the 10.0.2.0/24 subnet are on the
|
||||
local network associated with the network interface eth0.
|
||||
|
||||
Line 3 of the output specifies that IPs in the 192.168.27.0/24 subnet are on the
|
||||
local network associated with the network interface eth1.
|
||||
Line 3 of the output specifies that IPs in the 192.168.27.0/24 subnet
|
||||
are on the local network associated with the network interface eth1.
|
||||
|
||||
Line 4 of the output specifies that IPs in the 192.168.122/24 subnet are on the
|
||||
local network associated with the network interface virbr0.
|
||||
|
||||
The output of the ``route -n`` and ``netsat -rn`` commands are formatted in a
|
||||
slightly different way. This example shows how the same routes would be formatted
|
||||
using these commands::
|
||||
The output of the ``route -n`` and ``netsat -rn`` commands are
|
||||
formatted in a slightly different way. This example shows how the same
|
||||
routes would be formatted using these commands::
|
||||
|
||||
$ route -n
|
||||
Kernel IP routing table
|
||||
@ -308,8 +318,8 @@ using these commands::
|
||||
192.168.122.0 0.0.0.0 255.255.255.0 U 0 0 0 virbr0
|
||||
|
||||
The ``ip route get`` command outputs the route for a destination IP address.
|
||||
From the above example, destination IP address 10.0.2.14 is on the local network
|
||||
of eth0 and would be sent directly::
|
||||
From the above example, destination IP address 10.0.2.14 is on the
|
||||
local network of eth0 and would be sent directly::
|
||||
|
||||
$ ip route get 10.0.2.14
|
||||
10.0.2.14 dev eth0 src 10.0.2.15
|
||||
@ -357,21 +367,24 @@ applications. A TCP port is associated with a number in the range 1-65535, and
|
||||
only one application on a host can be associated with a TCP port at a time, a
|
||||
restriction that is enforced by the operating system.
|
||||
|
||||
A TCP server is said to *listen* on a port. For example, an SSH server typically
|
||||
listens on port 22. For a client to connect to a server using TCP, the client
|
||||
must know both the IP address of a server's host and the server's TCP port.
|
||||
A TCP server is said to *listen* on a port. For example, an SSH server
|
||||
typically listens on port 22. For a client to connect to a server
|
||||
using TCP, the client must know both the IP address of a server's host
|
||||
and the server's TCP port.
|
||||
|
||||
The operating system of the TCP client application automatically
|
||||
assigns a port number to the client. The client owns this port number until
|
||||
the TCP connection is terminated, after which time the operating system
|
||||
reclaims the port number. These types of ports are referred to as *ephemeral ports*.
|
||||
assigns a port number to the client. The client owns this port number
|
||||
until the TCP connection is terminated, after which time the operating
|
||||
system reclaims the port number. These types of ports are referred to
|
||||
as *ephemeral ports*.
|
||||
|
||||
IANA maintains a `registry of port numbers`_ for many TCP-based services, as
|
||||
well as services that use other layer 4 protocols that employ ports. Registering
|
||||
a TCP port number is not required, but registering a port number is helpful to
|
||||
avoid collisions with other services. See `Appendix B. Firewalls and default
|
||||
ports`_ of the `OpenStack Configuration Reference`_ for the default TCP ports
|
||||
used by various services involved in an OpenStack deployment.
|
||||
IANA maintains a `registry of port numbers`_ for many TCP-based
|
||||
services, as well as services that use other layer 4 protocols that
|
||||
employ ports. Registering a TCP port number is not required, but
|
||||
registering a port number is helpful to avoid collisions with other
|
||||
services. See `Appendix B. Firewalls and default ports`_ of the
|
||||
`OpenStack Configuration Reference`_ for the default TCP ports used by
|
||||
various services involved in an OpenStack deployment.
|
||||
|
||||
.. _registry of port numbers: http://www.iana.org/assignments/service-names-port-numbers/service-names-port-numbers.xhtml
|
||||
.. _Appendix B. Firewalls and default ports: http://docs.openstack.org/kilo/config-reference/content/firewalls-default-ports.html
|
||||
@ -384,21 +397,23 @@ simply, *sockets*. The sockets API exposes a *stream oriented* interface for
|
||||
writing TCP applications: from the perspective of a programmer, sending data
|
||||
over a TCP connection is similar to writing a stream of bytes to a file. It is
|
||||
the responsibility of the operating system's TCP/IP implementation to break up
|
||||
the stream of data into IP packets. The operating system is also responsible for
|
||||
automatically retransmitting dropped packets, and for handling flow control to
|
||||
ensure that transmitted data does not overrun the sender's data buffers,
|
||||
receiver's data buffers, and network capacity. Finally, the operating system is
|
||||
responsible for re-assembling the packets in the correct order into a stream of
|
||||
data on the receiver's side. Because TCP detects and retransmits lost packets,
|
||||
it is said to be a *reliable* protocol.
|
||||
the stream of data into IP packets. The operating system is also
|
||||
responsible for automatically retransmitting dropped packets, and for
|
||||
handling flow control to ensure that transmitted data does not overrun
|
||||
the sender's data buffers, receiver's data buffers, and network
|
||||
capacity. Finally, the operating system is responsible for
|
||||
re-assembling the packets in the correct order into a stream of data
|
||||
on the receiver's side. Because TCP detects and retransmits lost
|
||||
packets, it is said to be a *reliable* protocol.
|
||||
|
||||
The *User Datagram Protocol* (UDP) is another layer 4 protocol that is the basis
|
||||
of several well-known networking protocols. UDP is a *connectionless* protocol:
|
||||
two applications that communicate over UDP do not need to establish a connection
|
||||
before exchanging data. UDP is also an *unreliable* protocol. The operating
|
||||
system does not attempt to retransmit or even detect lost UDP packets. The
|
||||
operating system also does not provide any guarantee that the receiving
|
||||
application sees the UDP packets in the same order that they were sent in.
|
||||
The *User Datagram Protocol* (UDP) is another layer 4 protocol that is
|
||||
the basis of several well-known networking protocols. UDP is a
|
||||
*connectionless* protocol: two applications that communicate over UDP
|
||||
do not need to establish a connection before exchanging data. UDP is
|
||||
also an *unreliable* protocol. The operating system does not attempt
|
||||
to retransmit or even detect lost UDP packets. The operating system
|
||||
also does not provide any guarantee that the receiving application
|
||||
sees the UDP packets in the same order that they were sent in.
|
||||
|
||||
UDP, like TCP, uses the notion of ports to distinguish between different
|
||||
applications running on the same system. Note, however, that operating systems
|
||||
@ -416,23 +431,25 @@ for implementing this functionality in the application code.
|
||||
DHCP_, the Domain Name System (DNS), the Network Time Protocol (NTP), and
|
||||
:ref:`VXLAN` are examples of UDP-based protocols used in OpenStack deployments.
|
||||
|
||||
UDP has support for one-to-many communication: sending a single packet to multiple
|
||||
hosts. An application can broadcast a UDP packet to all of the network
|
||||
hosts on a local network by setting the receiver IP address as the special IP
|
||||
broadcast address ``255.255.255.255``. An application can also send a UDP packet to a
|
||||
set of receivers using *IP multicast*. The intended receiver applications join a
|
||||
multicast group by binding a UDP socket to a special IP address that is one of
|
||||
the valid multicast group addresses. The receiving hosts do not have to be on the
|
||||
same local network as the sender, but the intervening routers must be configured
|
||||
to support IP multicast routing. VXLAN is an example of a UDP-based protocol
|
||||
that uses IP multicast.
|
||||
UDP has support for one-to-many communication: sending a single packet
|
||||
to multiple hosts. An application can broadcast a UDP packet to all of
|
||||
the network hosts on a local network by setting the receiver IP
|
||||
address as the special IP broadcast address ``255.255.255.255``. An
|
||||
application can also send a UDP packet to a set of receivers using *IP
|
||||
multicast*. The intended receiver applications join a multicast group
|
||||
by binding a UDP socket to a special IP address that is one of the
|
||||
valid multicast group addresses. The receiving hosts do not have to be
|
||||
on the same local network as the sender, but the intervening routers
|
||||
must be configured to support IP multicast routing. VXLAN is an
|
||||
example of a UDP-based protocol that uses IP multicast.
|
||||
|
||||
The *Internet Control Message Protocol* (ICMP) is a protocol used for sending
|
||||
control messages over an IP network. For example, a router that receives an IP
|
||||
packet may send an ICMP packet back to the source if there is no route in the
|
||||
router's routing table that corresponds to the destination address (ICMP code 1,
|
||||
destination host unreachable) or if the IP packet is too large for the router to
|
||||
handle (ICMP code 4, fragmentation required and "don't fragment" flag is set).
|
||||
router's routing table that corresponds to the destination address
|
||||
(ICMP code 1, destination host unreachable) or if the IP packet is too
|
||||
large for the router to handle (ICMP code 4, fragmentation required
|
||||
and "don't fragment" flag is set).
|
||||
|
||||
The *ping* and *mtr* Linux command-line tools are two examples of network
|
||||
utilities that use ICMP.
|
||||
|
@ -7,11 +7,11 @@ destination addresses in the headers of an IP packet while the packet is
|
||||
in transit. In general, the sender and receiver applications are not aware that
|
||||
the IP packets are being manipulated.
|
||||
|
||||
NAT is often implemented by routers, and so we will refer to the host performing
|
||||
NAT as a *NAT router*. However, in OpenStack deployments it is
|
||||
typically Linux servers that implement the NAT functionality, not hardware
|
||||
routers. These servers use the iptables_ software package to implement the
|
||||
NAT functionality.
|
||||
NAT is often implemented by routers, and so we will refer to the host
|
||||
performing NAT as a *NAT router*. However, in OpenStack deployments it
|
||||
is typically Linux servers that implement the NAT functionality, not
|
||||
hardware routers. These servers use the iptables_ software package to
|
||||
implement the NAT functionality.
|
||||
|
||||
There are multiple variations of NAT, and here we describe three kinds
|
||||
commonly found in OpenStack deployments.
|
||||
@ -47,18 +47,19 @@ the source, then the web server cannot send packets back to the sender.
|
||||
SNAT solves this problem by modifying the source IP address to an IP address
|
||||
that is routable on the public Internet. There are different variations of
|
||||
SNAT; in the form that OpenStack deployments use, a NAT router on the path
|
||||
between the sender and receiver replaces the packet's source IP address with the
|
||||
router's public IP address. The router also modifies the source TCP or UDP port
|
||||
to another value, and the router maintains a record of the sender's true IP
|
||||
address and port, as well as the modified IP address and port.
|
||||
between the sender and receiver replaces the packet's source IP
|
||||
address with the router's public IP address. The router also modifies
|
||||
the source TCP or UDP port to another value, and the router maintains
|
||||
a record of the sender's true IP address and port, as well as the
|
||||
modified IP address and port.
|
||||
|
||||
When the router receives a packet with the matching IP address and port, it
|
||||
translates these back to the private IP address and port, and forwards the
|
||||
packet along.
|
||||
|
||||
Because the NAT router modifies ports as well as IP addresses, this form of SNAT
|
||||
is sometimes referred to as *Port Address Translation* (PAT). It is also sometimes
|
||||
referred to as *NAT overload*.
|
||||
Because the NAT router modifies ports as well as IP addresses, this
|
||||
form of SNAT is sometimes referred to as *Port Address Translation*
|
||||
(PAT). It is also sometimes referred to as *NAT overload*.
|
||||
|
||||
OpenStack uses SNAT to enable applications running inside of instances to
|
||||
connect out to the public Internet.
|
||||
@ -66,20 +67,21 @@ connect out to the public Internet.
|
||||
DNAT
|
||||
~~~~
|
||||
|
||||
In *Destination Network Address Translation* (DNAT), the NAT router modifies the
|
||||
IP address of the destination in IP packet headers.
|
||||
In *Destination Network Address Translation* (DNAT), the NAT router
|
||||
modifies the IP address of the destination in IP packet headers.
|
||||
|
||||
OpenStack uses DNAT to route packets from instances to the OpenStack metadata service.
|
||||
Applications running inside of instances access the OpenStack metadata service
|
||||
by making HTTP GET requests to a web server with IP address 169.254.169.254. In an
|
||||
OpenStack deployment, there is no host with this IP address. Instead, OpenStack
|
||||
uses DNAT to change the destination IP of these packets so they reach the
|
||||
network interface that a metadata service is listening on.
|
||||
OpenStack uses DNAT to route packets from instances to the OpenStack
|
||||
metadata service. Applications running inside of instances access the
|
||||
OpenStack metadata service by making HTTP GET requests to a web server
|
||||
with IP address 169.254.169.254. In an OpenStack deployment, there is
|
||||
no host with this IP address. Instead, OpenStack uses DNAT to change
|
||||
the destination IP of these packets so they reach the network
|
||||
interface that a metadata service is listening on.
|
||||
|
||||
One-to-one NAT
|
||||
~~~~~~~~~~~~~~
|
||||
|
||||
In *one-to-one NAT*, the NAT router maintains a one-to-one mapping between private IP
|
||||
addresses and public IP addresses. OpenStack uses one-to-one NAT to implement
|
||||
floating IP addresses.
|
||||
In *one-to-one NAT*, the NAT router maintains a one-to-one mapping
|
||||
between private IP addresses and public IP addresses. OpenStack uses
|
||||
one-to-one NAT to implement floating IP addresses.
|
||||
|
||||
|
@ -1,114 +1,128 @@
|
||||
====================================================================================
|
||||
Migrate the legacy nova-network networking service to OpenStack Networking (neutron)
|
||||
====================================================================================
|
||||
=============================================================
|
||||
Migrate legacy nova-network to OpenStack Networking (neutron)
|
||||
=============================================================
|
||||
|
||||
Two networking models exist in OpenStack. The first is called legacy networking
|
||||
(nova-network) and it is a sub-process embedded in the Compute project (nova).
|
||||
This model has some limitations, such as creating complex network topologies, extending
|
||||
its back-end implementation to vendor-specific technologies, and providing
|
||||
tenant-specific networking elements. These limitations are the main reasons the
|
||||
OpenStack Networking (neutron) model was created.
|
||||
This model has some limitations, such as creating complex network
|
||||
topologies, extending its back-end implementation to vendor-specific
|
||||
technologies, and providing tenant-specific networking elements. These
|
||||
limitations are the main reasons the OpenStack Networking (neutron)
|
||||
model was created.
|
||||
|
||||
This section describes the process of migrating clouds based on the legacy networking
|
||||
model to the OpenStack Networking model. This process requires additional changes to
|
||||
both compute and networking to support the migration. This document describes the
|
||||
overall process and the features required in both Networking and Compute.
|
||||
This section describes the process of migrating clouds based on the
|
||||
legacy networking model to the OpenStack Networking model. This
|
||||
process requires additional changes to both compute and networking to
|
||||
support the migration. This document describes the overall process and
|
||||
the features required in both Networking and Compute.
|
||||
|
||||
The current process as designed is a minimally viable migration with the goal of
|
||||
deprecating and then removing legacy networking. Both the Compute and Networking teams agree
|
||||
that a "one-button" migration process from legacy networking to OpenStack Networking
|
||||
(neutron) is not an essential requirement for the deprecation and removal of the legacy
|
||||
networking at a future date. This section includes a process and tools which are
|
||||
designed to solve a simple use case migration.
|
||||
The current process as designed is a minimally viable migration with
|
||||
the goal of deprecating and then removing legacy networking. Both the
|
||||
Compute and Networking teams agree that a "one-button" migration
|
||||
process from legacy networking to OpenStack Networking (neutron) is
|
||||
not an essential requirement for the deprecation and removal of the
|
||||
legacy networking at a future date. This section includes a process
|
||||
and tools which are designed to solve a simple use case migration.
|
||||
|
||||
Users are encouraged to take these tools, test them, provide feedback, and then expand
|
||||
on the feature set to suit their own deployments; deployers that refrain from
|
||||
participating in this process intending to wait for a path that better suits their use
|
||||
case are likely to be disappointed.
|
||||
Users are encouraged to take these tools, test them, provide feedback,
|
||||
and then expand on the feature set to suit their own deployments;
|
||||
deployers that refrain from participating in this process intending to
|
||||
wait for a path that better suits their use case are likely to be
|
||||
disappointed.
|
||||
|
||||
Impact and limitations
|
||||
~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The migration process from the legacy nova-network networking service to OpenStack
|
||||
Networking (neutron) has some limitations and impacts on the operational state of the
|
||||
cloud. It is critical to understand them in order to decide whether or not this process
|
||||
is acceptable for your cloud and all users.
|
||||
The migration process from the legacy nova-network networking service
|
||||
to OpenStack Networking (neutron) has some limitations and impacts on
|
||||
the operational state of the cloud. It is critical to understand them
|
||||
in order to decide whether or not this process is acceptable for your
|
||||
cloud and all users.
|
||||
|
||||
Management impact
|
||||
-----------------
|
||||
|
||||
The Networking REST API is publicly read-only until after the migration is complete. During
|
||||
the migration, Networking REST API is read-write only to nova-api, and changes to Networking
|
||||
are only allowed via nova-api.
|
||||
The Networking REST API is publicly read-only until after the
|
||||
migration is complete. During the migration, Networking REST API is
|
||||
read-write only to nova-api, and changes to Networking are only
|
||||
allowed via nova-api.
|
||||
|
||||
The Compute REST API is available throughout the entire process, although there is a brief
|
||||
period where it is made read-only during a database migration. The Networking REST API will
|
||||
need to expose (to nova-api) all details necessary for reconstructing the information
|
||||
The Compute REST API is available throughout the entire process,
|
||||
although there is a brief period where it is made read-only during a
|
||||
database migration. The Networking REST API will need to expose (to
|
||||
nova-api) all details necessary for reconstructing the information
|
||||
previously held in the legacy networking database.
|
||||
|
||||
Compute needs a per-hypervisor "has_transitioned" boolean change in the data model to be
|
||||
used during the migration process. This flag is no longer required once the process is
|
||||
complete.
|
||||
Compute needs a per-hypervisor "has_transitioned" boolean change in
|
||||
the data model to be used during the migration process. This flag is
|
||||
no longer required once the process is complete.
|
||||
|
||||
Operations impact
|
||||
-----------------
|
||||
|
||||
In order to support a wide range of deployment options, the migration process described
|
||||
here requires a rolling restart of hypervisors. The rate and timing of specific
|
||||
hypervisor restarts is under the control of the operator.
|
||||
In order to support a wide range of deployment options, the migration
|
||||
process described here requires a rolling restart of hypervisors. The
|
||||
rate and timing of specific hypervisor restarts is under the control
|
||||
of the operator.
|
||||
|
||||
The migration may be paused, even for an extended period of time (for example, while
|
||||
testing or investigating issues) with some hypervisors on legacy networking and some
|
||||
on Networking, and Compute API remains fully functional. Individual hypervisors may be rolled
|
||||
back to legacy networking during this stage of the migration, although this requires
|
||||
The migration may be paused, even for an extended period of time (for
|
||||
example, while testing or investigating issues) with some hypervisors
|
||||
on legacy networking and some on Networking, and Compute API remains
|
||||
fully functional. Individual hypervisors may be rolled back to legacy
|
||||
networking during this stage of the migration, although this requires
|
||||
an additional restart.
|
||||
|
||||
In order to support the widest range of deployer needs, the process described here is
|
||||
easy to automate but is not already automated. Deployers should expect to perform
|
||||
multiple manual steps or write some simple scripts in order to perform this migration.
|
||||
In order to support the widest range of deployer needs, the process
|
||||
described here is easy to automate but is not already automated.
|
||||
Deployers should expect to perform multiple manual steps or write some
|
||||
simple scripts in order to perform this migration.
|
||||
|
||||
Performance impact
|
||||
------------------
|
||||
|
||||
During the migration, nova-network API calls will go through an additional internal
|
||||
conversion to Networking calls. This will have different and likely poorer performance
|
||||
characteristics compared with either the pre-migration or post-migration APIs.
|
||||
During the migration, nova-network API calls will go through an
|
||||
additional internal conversion to Networking calls. This will have
|
||||
different and likely poorer performance characteristics compared with
|
||||
either the pre-migration or post-migration APIs.
|
||||
|
||||
Migration process overview
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
#. Start neutron-server in intended final config, except with REST API restricted to
|
||||
read-write only by nova-api.
|
||||
#. Start neutron-server in intended final config, except with REST API
|
||||
restricted to read-write only by nova-api.
|
||||
#. Make the Compute REST API read-only.
|
||||
#. Run a DB dump/restore tool that creates Networking data structures representing current
|
||||
legacy networking config.
|
||||
#. Enable a nova-api proxy that recreates internal Compute objects from Networking information
|
||||
#. Run a DB dump/restore tool that creates Networking data structures
|
||||
representing current legacy networking config.
|
||||
#. Enable a nova-api proxy that recreates internal Compute objects
|
||||
from Networking information
|
||||
(via the Networking REST API).
|
||||
#. Make Compute REST API read-write again. This means legacy networking DB is now unused,
|
||||
new changes are now stored in the Networking DB, and no rollback is possible from here
|
||||
without losing those new changes.
|
||||
#. Make Compute REST API read-write again. This means legacy
|
||||
networking DB is now unused, new changes are now stored in the
|
||||
Networking DB, and no rollback is possible from here without losing
|
||||
those new changes.
|
||||
|
||||
.. note::
|
||||
At this moment the Networking DB is the source of truth, but nova-api is the only public
|
||||
read-write API.
|
||||
At this moment the Networking DB is the source of truth, but
|
||||
nova-api is the only public read-write API.
|
||||
|
||||
Next, you'll need to migrate each hypervisor. To do that, follow these steps:
|
||||
|
||||
#. Disable the hypervisor. This would be a good time to live migrate or evacuate the
|
||||
compute node, if supported.
|
||||
#. Disable the hypervisor. This would be a good time to live migrate
|
||||
or evacuate the compute node, if supported.
|
||||
#. Disable nova-compute.
|
||||
#. Enable the Networking agent.
|
||||
#. Set the "has_transitioned" flag in the Compute hypervisor database/config.
|
||||
#. Reboot the hypervisor (or run "smart" live transition tool if available).
|
||||
#. Re-enable the hypervisor.
|
||||
|
||||
At this point, all compute nodes have been migrated, but they are still using the
|
||||
nova-api API and Compute gateways. Finally, enable OpenStack Networking by following
|
||||
these steps:
|
||||
At this point, all compute nodes have been migrated, but they are
|
||||
still using the nova-api API and Compute gateways. Finally, enable
|
||||
OpenStack Networking by following these steps:
|
||||
|
||||
#. Bring up the Networking (l3) nodes. The new routers will have identical MAC+IPs as
|
||||
old Compute gateways so some sort of immediate cutover is possible, except for stateful
|
||||
connections issues such as NAT.
|
||||
#. Bring up the Networking (l3) nodes. The new routers will have
|
||||
identical MAC+IPs as old Compute gateways so some sort of immediate
|
||||
cutover is possible, except for stateful connections issues such as
|
||||
NAT.
|
||||
#. Make the Networking API read-write and disable legacy networking.
|
||||
|
||||
Migration Completed!
|
||||
|
@ -21,9 +21,10 @@ OpenStack Networking's networks, confined to a single node.
|
||||
libvirt network implementation
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
By default, libvirt's networking functionality is enabled, and libvirt creates a
|
||||
network when the system boots. To implement this network, libvirt leverages some of
|
||||
the same technologies that OpenStack Network does. In particular, libvirt uses:
|
||||
By default, libvirt's networking functionality is enabled, and libvirt
|
||||
creates a network when the system boots. To implement this network,
|
||||
libvirt leverages some of the same technologies that OpenStack Network
|
||||
does. In particular, libvirt uses:
|
||||
|
||||
* Linux bridging for implementing a layer 2 network
|
||||
* dnsmasq for providing IP addresses to virtual machines using DHCP
|
||||
@ -73,11 +74,12 @@ the output of :command:`ps`::
|
||||
How to disable libvirt networks
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
Although OpenStack does not make use of libvirt's networking, this networking
|
||||
will not interfere with OpenStack's behavior, and can be safely left enabled.
|
||||
However, libvirt's networking can be a nuisance when debugging OpenStack
|
||||
networking issues. Because libvirt creates an additional bridge, dnsmasq process, and
|
||||
iptables ruleset, these may distract an operator engaged in network troubleshooting.
|
||||
Although OpenStack does not make use of libvirt's networking, this
|
||||
networking will not interfere with OpenStack's behavior, and can be
|
||||
safely left enabled. However, libvirt's networking can be a nuisance
|
||||
when debugging OpenStack networking issues. Because libvirt creates an
|
||||
additional bridge, dnsmasq process, and iptables ruleset, these may
|
||||
distract an operator engaged in network troubleshooting.
|
||||
Unless you need to start up virtual machines using libvirt directly, you can
|
||||
safely disable libvirt's network.
|
||||
|
||||
@ -92,8 +94,8 @@ To deactivate the libvirt network named *default*::
|
||||
|
||||
# virsh net-destroy default
|
||||
|
||||
Deactivating the network will remove the ``virbr0`` bridge, terminate the dnsmasq process, and
|
||||
remove the iptables rules.
|
||||
Deactivating the network will remove the ``virbr0`` bridge, terminate
|
||||
the dnsmasq process, and remove the iptables rules.
|
||||
|
||||
To prevent the network from automatically starting on boot::
|
||||
|
||||
|
@ -2,10 +2,11 @@
|
||||
Manage IP addresses
|
||||
===================
|
||||
|
||||
Each instance has a private, fixed IP address (assigned when launched) and can also have a
|
||||
public, or floating, address. Private IP addresses are used for communication between
|
||||
instances, and public addresses are used for communication with networks outside the cloud,
|
||||
including the Internet.
|
||||
Each instance has a private, fixed IP address (assigned when launched)
|
||||
and can also have a public, or floating, address. Private IP addresses
|
||||
are used for communication between instances, and public addresses are
|
||||
used for communication with networks outside the cloud, including the
|
||||
Internet.
|
||||
|
||||
- By default, both administrative and end users can associate floating IP
|
||||
addresses with projects and instances. You can change user permissions for
|
||||
@ -19,8 +20,9 @@ including the Internet.
|
||||
floating IP addresses are created by default in OpenStack Networking.
|
||||
|
||||
As an administrator using legacy networking (``nova-network``), you
|
||||
can use the following bulk commands to list, create, and delete ranges of floating IP
|
||||
addresses. These addresses can then be associated with instances by end users.
|
||||
can use the following bulk commands to list, create, and delete ranges
|
||||
of floating IP addresses. These addresses can then be associated with
|
||||
instances by end users.
|
||||
|
||||
List addresses for all projects
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
@ -2,29 +2,32 @@
|
||||
Evacuate instances
|
||||
==================
|
||||
|
||||
If a cloud compute node fails due to a hardware malfunction or another reason, you can
|
||||
evacuate instances to make them available again. You can optionally include the target host
|
||||
on the :command:`evacuate` command. If you omit the host, the scheduler determines
|
||||
the target host.
|
||||
If a cloud compute node fails due to a hardware malfunction or another
|
||||
reason, you can evacuate instances to make them available again. You
|
||||
can optionally include the target host on the :command:`evacuate`
|
||||
command. If you omit the host, the scheduler determines the target
|
||||
host.
|
||||
|
||||
To preserve user data on server disk, you must configure shared storage on the target
|
||||
host. Also, you must validate that the current VM host is down; otherwise, the evacuation
|
||||
fails with an error.
|
||||
To preserve user data on server disk, you must configure shared
|
||||
storage on the target host. Also, you must validate that the current
|
||||
VM host is down; otherwise, the evacuation fails with an error.
|
||||
|
||||
#. To list hosts and find a different host for the evacuated instance, run::
|
||||
|
||||
$ nova host-list
|
||||
|
||||
#. Evacuate the instance. You can pass the instance password to the command by using
|
||||
the :option:`--password PWD` option. If you do not specify a
|
||||
password, one is generated and printed after the command finishes successfully. The
|
||||
following command evacuates a server without shared storage from a host that is down
|
||||
to the specified HOST_B::
|
||||
#. Evacuate the instance. You can pass the instance password to the
|
||||
command by using the :option:`--password PWD` option. If you do not
|
||||
specify a password, one is generated and printed after the command
|
||||
finishes successfully. The following command evacuates a server
|
||||
without shared storage from a host that is down to the specified
|
||||
HOST_B::
|
||||
|
||||
$ nova evacuate EVACUATED_SERVER_NAME HOST_B
|
||||
|
||||
The instance is booted from a new disk, but preserves its configuration including
|
||||
its ID, name, uid, IP address, and so on. The command returns a password::
|
||||
The instance is booted from a new disk, but preserves its
|
||||
configuration including its ID, name, uid, IP address, and so on.
|
||||
The command returns a password::
|
||||
|
||||
+-----------+--------------+
|
||||
| Property | Value |
|
||||
@ -32,9 +35,11 @@ fails with an error.
|
||||
| adminPass | kRAJpErnT4xZ |
|
||||
+-----------+--------------+
|
||||
|
||||
#. To preserve the user disk data on the evacuated server, deploy OpenStack Compute
|
||||
with a shared file system. To configure your system, see `Configure migrations <http://docs.openstack.org/admin-guide-cloud/content/section_configuring-compute-migrations.html>`_ in
|
||||
OpenStack Cloud Administrator Guide. In the following example, the
|
||||
password remains unchanged::
|
||||
#. To preserve the user disk data on the evacuated server, deploy
|
||||
OpenStack Compute with a shared file system. To configure your
|
||||
system, see `Configure migrations
|
||||
<http://docs.openstack.org/admin-guide-cloud/content/section_configuring-compute-migrations.html>`_
|
||||
in OpenStack Cloud Administrator Guide. In the following example,
|
||||
the password remains unchanged::
|
||||
|
||||
$ nova evacuate EVACUATED_SERVER_NAME HOST_B --on-shared-storage
|
||||
|
@ -9,25 +9,38 @@ tenant user, as well as update the quota defaults for a new tenant.
|
||||
|
||||
**Compute quota descriptions**
|
||||
|
||||
=============================== ========================================================
|
||||
Quota name Description
|
||||
=============================== ========================================================
|
||||
cores Number of instance cores (VCPUs)
|
||||
allowed per tenant.
|
||||
fixed-ips Number of fixed IP addresses allowed per tenant.
|
||||
This number must be equal to or
|
||||
greater than the number of allowed instances.
|
||||
floating-ips Number of floating IP addresses allowed per tenant.
|
||||
injected-file-content-bytes Number of content bytes allowed per injected file.
|
||||
injected-file-path-bytes Length of injected file path.
|
||||
injected-files Number of injected files allowed per tenant.
|
||||
instances Number of instances allowed per tenant.
|
||||
key-pairs Number of key pairs allowed per user.
|
||||
metadata-items Number of metadata items allowed per instance.
|
||||
ram Megabytes of instance ram allowed per tenant.
|
||||
security-groups Number of security groups per tenant.
|
||||
security-group-rules Number of rules per security group.
|
||||
=============================== ========================================================
|
||||
.. list-table::
|
||||
:header-rows: 1
|
||||
:widths: 10 40
|
||||
|
||||
* - Quota name
|
||||
- Description
|
||||
* - cores
|
||||
- Number of instance cores (VCPUs) allowed per tenant.
|
||||
* - fixed-ips
|
||||
- Number of fixed IP addresses allowed per tenant. This number
|
||||
must be equal to or greater than the number of allowed
|
||||
instances.
|
||||
* - floating-ips
|
||||
- Number of floating IP addresses allowed per tenant.
|
||||
* - injected-file-content-bytes
|
||||
- Number of content bytes allowed per injected file.
|
||||
* - injected-file-path-bytes
|
||||
- Length of injected file path.
|
||||
* - injected-files
|
||||
- Number of injected files allowed per tenant.
|
||||
* - instances
|
||||
- Number of instances allowed per tenant.
|
||||
* - key-pairs
|
||||
- Number of key pairs allowed per user.
|
||||
* - metadata-items
|
||||
- Number of metadata items allowed per instance.
|
||||
* - ram
|
||||
- Megabytes of instance ram allowed per tenant.
|
||||
* - security-groups
|
||||
- Number of security groups per tenant.
|
||||
* - security-group-rules
|
||||
- Number of rules per security group.
|
||||
|
||||
View and update Compute quotas for a tenant (project)
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
@ -69,9 +69,9 @@ To manage host aggregates
|
||||
- To manage hosts, locate the host aggregate that you want to edit
|
||||
in the table. Click :guilabel:`More` and select :guilabel:`Manage Hosts`.
|
||||
|
||||
In the :guilabel:`Add/Remove Hosts to Aggregate` dialog box, click **+** to
|
||||
assign a host to an aggregate. Click **-** to remove a host that is assigned
|
||||
to an aggregate.
|
||||
In the :guilabel:`Add/Remove Hosts to Aggregate` dialog box,
|
||||
click **+** to assign a host to an aggregate. Click **-** to
|
||||
remove a host that is assigned to an aggregate.
|
||||
|
||||
- To delete host aggregates, locate the host aggregate that you want
|
||||
to edit in the table. Click :guilabel:`More` and select
|
||||
|
@ -29,9 +29,10 @@ As an administrative user, you can view information for OpenStack services.
|
||||
* :guilabel:`Default Quotas`:
|
||||
Displays the quotas that have been configured for the cluster.
|
||||
|
||||
* :guilabel:`Availability Zones`: Displays the availability zones that have been configured
|
||||
for the cluster. It is only available when multiple availability zones have been defined.
|
||||
* :guilabel:`Availability Zones`: Displays the availability zones
|
||||
that have been configured for the cluster. It is only available
|
||||
when multiple availability zones have been defined.
|
||||
|
||||
* :guilabel:`Host Aggregates`: Displays the host aggregates that have been
|
||||
defined for the cluster. It is only available when multiple host aggregates
|
||||
have been defined.
|
||||
* :guilabel:`Host Aggregates`: Displays the host aggregates that
|
||||
have been defined for the cluster. It is only available when
|
||||
multiple host aggregates have been defined.
|
||||
|
@ -2,19 +2,22 @@
|
||||
View cloud usage statistics
|
||||
===========================
|
||||
|
||||
The Telemetry module provides user-level usage data for OpenStack-based clouds,
|
||||
which can be used for customer billing, system monitoring, or alerts. Data can be
|
||||
collected by notifications sent by existing OpenStack components (for example,
|
||||
usage events emitted from Compute) or by polling the infrastructure (for example,
|
||||
libvirt).
|
||||
The Telemetry module provides user-level usage data for
|
||||
OpenStack-based clouds, which can be used for customer billing, system
|
||||
monitoring, or alerts. Data can be collected by notifications sent by
|
||||
existing OpenStack components (for example, usage events emitted from
|
||||
Compute) or by polling the infrastructure (for example, libvirt).
|
||||
|
||||
.. note::
|
||||
You can only view metering statistics on the dashboard (available only to administrators).
|
||||
|
||||
You can only view metering statistics on the dashboard (available
|
||||
only to administrators).
|
||||
The Telemetry service must be set up and administered through the
|
||||
:command:`ceilometer` command-line interface (CLI).
|
||||
|
||||
For basic administration information, refer to the "Measure Cloud Resources"
|
||||
chapter in the `OpenStack End User Guide <http://docs.openstack.org/user-guide/>`_.
|
||||
For basic administration information, refer to the "Measure Cloud
|
||||
Resources" chapter in the `OpenStack End User Guide
|
||||
<http://docs.openstack.org/user-guide/>`_.
|
||||
|
||||
.. _dashboard-view-resource-stats:
|
||||
|
||||
@ -29,15 +32,17 @@ View resource statistics
|
||||
|
||||
* :guilabel:`Global Disk Usage` tab to view disk usage per tenant (project).
|
||||
|
||||
* :guilabel:`Global Network Traffic Usage` tab to view ingress or egress usage
|
||||
per tenant (project).
|
||||
* :guilabel:`Global Network Traffic Usage` tab to view ingress or
|
||||
egress usage per tenant (project).
|
||||
|
||||
* :guilabel:`Global Object Storage Usage` tab to view incoming and outgoing
|
||||
storage bytes per tenant (project).
|
||||
|
||||
* :guilabel:`Global Network Usage` tab to view duration and creation requests for
|
||||
networks, subnets, routers, ports, and floating IPs, per tenant (project).
|
||||
* :guilabel:`Global Network Usage` tab to view duration and
|
||||
creation requests for networks, subnets, routers, ports, and
|
||||
floating IPs, per tenant (project).
|
||||
|
||||
* :guilabel:`Stats` tab to view a multi-series line chart with user-defined
|
||||
meters. You group by project, define the value type (min, max, avg, or sum),
|
||||
and specify the time period (or even use a calendar to define a date range).
|
||||
* :guilabel:`Stats` tab to view a multi-series line chart with
|
||||
user-defined meters. You group by project, define the value type
|
||||
(min, max, avg, or sum), and specify the time period (or even use
|
||||
a calendar to define a date range).
|
||||
|
@ -59,8 +59,8 @@ Alarm
|
||||
The comparison operator compares a selected meter statistic against
|
||||
an evaluation window of configurable length into the recent past.
|
||||
|
||||
This example uses the :command:`heat` client to create an auto-scaling stack and the
|
||||
:command:`ceilometer` client to measure resources.
|
||||
This example uses the :command:`heat` client to create an auto-scaling
|
||||
stack and the :command:`ceilometer` client to measure resources.
|
||||
|
||||
#. Create an auto-scaling stack by running the following command.
|
||||
The :option:`-f` option specifies the name of the stack template
|
||||
|
@ -236,7 +236,8 @@ Create ports
|
||||
| f7a08fe4-e7... | | fa:16:3e:97:e0:fc | {"subnet_id"... ..."ip_address": "192.168.2.40"}|
|
||||
+----------------+------+-------------------+-------------------------------------------------+
|
||||
|
||||
``--fixed-ips ip_address=192.168.2.2 ip_address=192.168.2.40`` is one unknown option.
|
||||
``--fixed-ips ip_address=192.168.2.2 ip_address=192.168.2.40`` is one
|
||||
unknown option.
|
||||
|
||||
**How to find unknown options**
|
||||
The unknown options can be easily found by watching the output of
|
||||
|
@ -63,11 +63,12 @@ Before you can launch an instance, gather the following parameters:
|
||||
make it accessible from outside the cloud. See
|
||||
:doc:`cli_manage_ip_addresses`.
|
||||
|
||||
After you gather the parameters that you need to launch an instance, you
|
||||
can launch it from an image_ or a :ref:`volume`. You can launch an instance directly
|
||||
from one of the available OpenStack images or from an image that you have
|
||||
copied to a persistent volume. The OpenStack Image service provides a
|
||||
pool of images that are accessible to members of different projects.
|
||||
After you gather the parameters that you need to launch an instance,
|
||||
you can launch it from an image_ or a :ref:`volume`. You can launch an
|
||||
instance directly from one of the available OpenStack images or from
|
||||
an image that you have copied to a persistent volume. The OpenStack
|
||||
Image service provides a pool of images that are accessible to members
|
||||
of different projects.
|
||||
|
||||
Gather parameters to launch an instance
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
@ -54,8 +54,8 @@ Create a snapshot of the instance
|
||||
$ nova image-create --poll myInstance myInstanceSnapshot
|
||||
Instance snapshotting... 50% complete
|
||||
|
||||
#. Use the :command:`nova image-list` command to check the status until the status is
|
||||
``ACTIVE``::
|
||||
#. Use the :command:`nova image-list` command to check the status
|
||||
until the status is ``ACTIVE``::
|
||||
|
||||
$ nova image-list
|
||||
+--------------------------------------+---------------------------------+--------+--------+
|
||||
|
@ -157,8 +157,8 @@ copy of the image on the compute node where the instance starts.
|
||||
|
||||
The instance starts on a compute node in the cloud.
|
||||
|
||||
The :guilabel:`Instances` tab shows the instance's name, its private and public IP
|
||||
addresses, size, status, task, and power state.
|
||||
The :guilabel:`Instances` tab shows the instance's name, its private
|
||||
and public IP addresses, size, status, task, and power state.
|
||||
|
||||
If you did not provide a key pair, security groups, or rules, users can
|
||||
access the instance only from inside the cloud through VNC. Even pinging
|
||||
|
@ -66,8 +66,8 @@ The following template defines the :file:`my_nova.yaml` file as value for the
|
||||
properties:
|
||||
key_name: my_key
|
||||
|
||||
The :code:`key_name` argument of the ``my_nova.yaml`` template gets its value from
|
||||
the :code:`key_name` property of the new template.
|
||||
The :code:`key_name` argument of the ``my_nova.yaml`` template gets
|
||||
its value from the :code:`key_name` property of the new template.
|
||||
|
||||
.. note::
|
||||
|
||||
|
@ -177,12 +177,14 @@ data, and metadata is derived from any associated
|
||||
|
||||
Signals and wait conditions
|
||||
---------------------------
|
||||
Often it is necessary to pause further creation of stack resources until the
|
||||
boot configuration script has notified that it has reached a certain state.
|
||||
This is usually either to notify that a service is now active, or to pass out
|
||||
some generated data which is needed by another resource. The resources
|
||||
:hotref:`OS::Heat::WaitCondition` and :hotref:`OS::Heat::SwiftSignal` both perform
|
||||
this function using different techniques and tradeoffs.
|
||||
|
||||
Often it is necessary to pause further creation of stack resources
|
||||
until the boot configuration script has notified that it has reached a
|
||||
certain state. This is usually either to notify that a service is now
|
||||
active, or to pass out some generated data which is needed by another
|
||||
resource. The resources :hotref:`OS::Heat::WaitCondition` and
|
||||
:hotref:`OS::Heat::SwiftSignal` both perform this function using
|
||||
different techniques and tradeoffs.
|
||||
|
||||
:hotref:`OS::Heat::WaitCondition` is implemented as a call to the
|
||||
`Orchestration API`_ resource signal. The token is created using credentials
|
||||
@ -529,10 +531,11 @@ The `Custom image script`_ already includes the ``heat-config-script`` element
|
||||
so the built image will already have the ability to configure using shell
|
||||
scripts.
|
||||
|
||||
Config inputs are mapped to shell environment variables. The script can
|
||||
communicate outputs to heat by writing to the :file:`$heat_outputs_path.{output name}`
|
||||
file. See the following example for a script
|
||||
which expects inputs ``foo``, ``bar`` and generates an output ``result``.
|
||||
Config inputs are mapped to shell environment variables. The script
|
||||
can communicate outputs to heat by writing to the
|
||||
:file:`$heat_outputs_path.{output name}` file. See the following
|
||||
example for a script which expects inputs ``foo``, ``bar`` and
|
||||
generates an output ``result``.
|
||||
|
||||
.. code-block:: yaml
|
||||
:linenos:
|
||||
|
@ -250,8 +250,10 @@ with the syntax for each type.
|
||||
|
||||
length
|
||||
++++++
|
||||
The :code:`length` constraint applies to parameters of type ``string``. It defines
|
||||
a lower and upper limit for the length of the string value.
|
||||
|
||||
The :code:`length` constraint applies to parameters of type
|
||||
``string``. It defines a lower and upper limit for the length of the
|
||||
string value.
|
||||
|
||||
The syntax of the :code:`length` constraint is:
|
||||
|
||||
@ -264,8 +266,10 @@ upper limit. However, at least one of ``min`` or ``max`` must be specified.
|
||||
|
||||
range
|
||||
+++++
|
||||
The :code:`range` constraint applies to parameters of type ``number``. It defines a
|
||||
lower and upper limit for the numeric value of the parameter.
|
||||
|
||||
The :code:`range` constraint applies to parameters of type ``number``.
|
||||
It defines a lower and upper limit for the numeric value of the
|
||||
parameter.
|
||||
|
||||
The syntax of the :code:`range` constraint is:
|
||||
|
||||
@ -285,10 +289,11 @@ following range constraint would allow for all numeric values between 0 and 10:
|
||||
|
||||
allowed_values
|
||||
++++++++++++++
|
||||
The :code:`allowed_values` constraint applies to parameters of type ``string`` or
|
||||
``number``. It specifies a set of possible values for a parameter. At
|
||||
deployment time, the user-provided value for the respective parameter must
|
||||
match one of the elements of the list.
|
||||
|
||||
The :code:`allowed_values` constraint applies to parameters of type
|
||||
``string`` or ``number``. It specifies a set of possible values for a
|
||||
parameter. At deployment time, the user-provided value for the
|
||||
respective parameter must match one of the elements of the list.
|
||||
|
||||
The syntax of the :code:`allowed_values` constraint is:
|
||||
|
||||
@ -323,9 +328,10 @@ For example:
|
||||
|
||||
allowed_pattern
|
||||
+++++++++++++++
|
||||
The :code:`allowed_pattern` constraint applies to parameters of type ``string``.
|
||||
It specifies a regular expression against which a user-provided parameter value
|
||||
must evaluate at deployment.
|
||||
|
||||
The :code:`allowed_pattern` constraint applies to parameters of type
|
||||
``string``. It specifies a regular expression against which a
|
||||
user-provided parameter value must evaluate at deployment.
|
||||
|
||||
The syntax of the :code:`allowed_pattern` constraint is:
|
||||
|
||||
@ -760,7 +766,9 @@ For example:
|
||||
|
||||
list_join
|
||||
---------
|
||||
The :code:`list_join` function joins a list of strings with the given delimiter.
|
||||
|
||||
The :code:`list_join` function joins a list of strings with the given
|
||||
delimiter.
|
||||
|
||||
The syntax of the :code:`list_join` function is:
|
||||
|
||||
@ -780,7 +788,9 @@ This resolve to the string ``one, two, and three``.
|
||||
|
||||
resource_facade
|
||||
---------------
|
||||
The :code:`resource_facade` function retrieves data in a parent provider template.
|
||||
|
||||
The :code:`resource_facade` function retrieves data in a parent
|
||||
provider template.
|
||||
|
||||
A provider template provides a custom definition of a resource, called its
|
||||
facade. For more information about custom templates, see :ref:`composition`.
|
||||
@ -838,8 +848,8 @@ application:
|
||||
params:
|
||||
host: { get_attr: [ my_instance, first_address ] }
|
||||
|
||||
The following examples show the use of the :code:`str_replace` function to build an
|
||||
instance initialization script:
|
||||
The following examples show the use of the :code:`str_replace`
|
||||
function to build an instance initialization script:
|
||||
|
||||
.. code-block:: yaml
|
||||
:linenos:
|
||||
|
4
tox.ini
4
tox.ini
@ -94,12 +94,12 @@ commands = {toxinidir}/tools/generatepot-rst.sh {posargs}
|
||||
[doc8]
|
||||
# Settings for doc8:
|
||||
# Ignore target directories
|
||||
ignore-path = doc/*/target,doc/*/build,doc/common-rst/glossary.rst
|
||||
ignore-path = doc/*/target,doc/*/build*,doc/common-rst/glossary.rst
|
||||
# File extensions to use
|
||||
extensions = .rst,.txt
|
||||
# Maximal line length should be 79 but we have some overlong lines.
|
||||
# Let's not get far more in.
|
||||
max-line-length = 100
|
||||
max-line-length = 79
|
||||
# Disable some doc8 checks:
|
||||
# D000: Check RST validity (cannot handle lineos directive)
|
||||
ignore = D000
|
||||
|
Loading…
Reference in New Issue
Block a user