Merge "[arch-guide] Adding arch guidance to storage design"
This commit is contained in:
commit
ea55880fc0
@ -182,8 +182,82 @@ Cost
|
||||
incompatibility and interoperability issues.
|
||||
|
||||
Performance
|
||||
The latency of storage I/O requests indicates performance. Performance
|
||||
requirements affect which solution you choose.
|
||||
Performance of block based storage is typically measured in the maximum read
|
||||
and write operations to non-contiguous storage locations per second. This
|
||||
measurement typically applies to SAN, hard drives, and solid state drives.
|
||||
While IOPS can be broadly measured and is not an official benchmark, many
|
||||
vectors like to be used by vendors to communicate performance levels. Since
|
||||
there are no real standards for measuring IOPS, vendor test results may vary,
|
||||
sometimes wildly. However, along with transfer rate which measures the speed
|
||||
that data can be transferred to contiguous storage locations, IOPS can be
|
||||
used in a performance evaluation. Typically, transfer rate is represented by
|
||||
a bytes per second calculation but IOPS is measured by an integer.
|
||||
|
||||
To calculate IOPS for a single drive you could use:
|
||||
IOPS = 1 / (AverageLatency + AverageSeekTime)
|
||||
For example:
|
||||
Average Latency for Single Disk = 2.99ms or .00299 seconds
|
||||
Average Seek Time for Single Disk = 4.7ms or .0047 seconds
|
||||
IOPS = 1/(.00299 + .0047)
|
||||
IOPS = 130
|
||||
|
||||
To calculate maximum IOPS for a disk array:
|
||||
Maximum Read IOPS:
|
||||
In order to accurately calculate maximum read IOPS for a disk array,
|
||||
multiply the IOPS for each disk by the maximum read or write IOPS per disk.
|
||||
maxReadIOPS = nDisks * diskMaxIOPS
|
||||
For example, 15 10K Spinning Disks would be measured the following way:
|
||||
maxReadIOPS = 15 * 130 maxReadIOPS = 1950
|
||||
|
||||
Maximum write IOPS per array:
|
||||
Determining the maximum *write* IOPS is a little different because most
|
||||
administrators configure disk replication using RAID and since the RAID
|
||||
controller requires IOPS itself, there is a write penalty. The severity of
|
||||
the write penalty is determined by the type of RAID used.
|
||||
|
||||
=========== ==========
|
||||
Raid Type Penalty
|
||||
----------- ----------
|
||||
1 2
|
||||
5 4
|
||||
10 2
|
||||
=========== ==========
|
||||
|
||||
.. note::
|
||||
|
||||
Raid 5 has the worst penalty (has the most cross disk writes.)
|
||||
Therefore, when using the above examples, a 15 disk array using RAID 5 is
|
||||
capable of 1950 read IOPS however, we need to add the penalty when
|
||||
determining the *write* IOPS:
|
||||
|
||||
.. code-block:: none
|
||||
|
||||
maxWriteIOPS = 1950 / 4
|
||||
maxWriteIOPS = 487.5
|
||||
|
||||
A RAID 5 array only has 25% of the write IOPS of the read IOPS while a RAID
|
||||
1 array in this case would produce a maximum of 975 IOPS.
|
||||
|
||||
What about SSD? DRAM SSD?
|
||||
In an HDD, data transfer is sequential. The actual read/write head "seeks" a
|
||||
point in the hard drive to execute the operation. Seek time is significant.
|
||||
Transfer rate can also be influenced by file system fragmentation and the
|
||||
layout. Finally, the mechanical nature of hard disks also has certain
|
||||
performance limitations.
|
||||
|
||||
In an SSD, data transfer is *not* sequential; it is random so it is faster.
|
||||
There is consistent read performance because the physical location of data is
|
||||
irrelevant because SSDs have no read/write heads and thus no delays due to
|
||||
head motion (seeking).
|
||||
|
||||
.. note::
|
||||
|
||||
Some basic benchmarks for small read/writes:
|
||||
|
||||
- **HDDs**: Small reads – 175 IOPs, Small writes – 280 IOPs
|
||||
- **Flash SSDs**: Small reads – 1075 IOPs (6x), Small writes – 21 IOPs (0.1x)
|
||||
- **DRAM SSDs**: Small reads – 4091 IOPs (23x), Small writes – 4184 IOPs
|
||||
(14x)
|
||||
|
||||
Scalability
|
||||
Scalability, along with expandability, is a major consideration in a
|
||||
@ -207,9 +281,9 @@ Configure Block Storage resource nodes with advanced RAID controllers
|
||||
and high-performance disks to provide fault tolerance at the hardware
|
||||
level.
|
||||
|
||||
Deploy high performing storage solutions such as SSD drives or
|
||||
flash storage systems for applications requiring additional performance out
|
||||
of Block Storage devices.
|
||||
We recommend deploying high performing storage solutions such as SSD
|
||||
drives or flash storage systems for applications requiring additional
|
||||
performance out of Block Storage devices.
|
||||
|
||||
In environments that place substantial demands on Block Storage, we
|
||||
recommend using multiple storage pools. In this case, each pool of
|
||||
@ -418,9 +492,51 @@ nodes and proxy servers should make use of a design which is scalable.
|
||||
Redundancy
|
||||
----------
|
||||
|
||||
.. TODO
|
||||
|
||||
|
||||
Replication
|
||||
-----------
|
||||
|
||||
.. TODO
|
||||
Replicas in Object Storage function independently, and clients only
|
||||
require a majority of nodes to respond to a request in order for an
|
||||
operation to be considered successful. Thus, transient failures like
|
||||
network partitions can quickly cause replicas to diverge.
|
||||
Fix These differences are eventually reconciled by
|
||||
asynchronous, peer-to-peer replicator processes. The replicator processes
|
||||
traverse their local filesystems, concurrently performing operations in a
|
||||
manner that balances load across physical disks.
|
||||
|
||||
Replication uses a push model, with records and files generally only being
|
||||
copied from local to remote replicas. This is important because data on the
|
||||
node may not belong there (as in the case of handoffs and ring changes), and a
|
||||
replicator can not know what data exists elsewhere in the cluster that it
|
||||
should pull in. It is the duty of any node that contains data to ensure that
|
||||
data gets to where it belongs. Replica placement is handled by the ring.
|
||||
|
||||
Every deleted record or file in the system is marked by a tombstone, so that
|
||||
deletions can be replicated alongside creations. The replication process cleans
|
||||
up tombstones after a time period known as the consistency window. The
|
||||
consistency window encompasses replication duration and the length of time a
|
||||
transient failure can remove a node from the cluster. Tombstone cleanup must be
|
||||
tied to replication to reach replica convergence.
|
||||
|
||||
If a replicator detects that a remote drive has failed, the replicator uses the
|
||||
``get_more_nodes`` interface for the ring to choose an alternative node with
|
||||
which to synchronize. The replicator can maintain desired levels of replication
|
||||
in the face of disk failures, though some replicas may not be in an immediately
|
||||
usable location.
|
||||
|
||||
.. note::
|
||||
|
||||
The replicator does not maintain desired levels of replication when other
|
||||
failures occur, such as entire node failures, because most failures are
|
||||
transient.
|
||||
|
||||
Replication is an area of active development, andimplementation details
|
||||
are likely to change over time.
|
||||
|
||||
There are two major classes of replicator: the db replicator, which replicates
|
||||
accounts and containers, and the object replicator, which replicates object
|
||||
data.
|
||||
|
||||
For more information, please see the `Swift replication page <https://docs.openstack.org/developer/swift/overview_replication.html>`_.
|
||||
|
Loading…