openstack-manuals/doc/common/tables/cinder-hpmsa.xml
Chris Maio 8841674998 Fix cinder.headers entry for HP MSA volume driver
The HP MSA volume driver supports both Fibre Channel and iSCSI host
attach.

Change-Id: I1d40247a3f6404d076ece1941c2cf836b9a37907
2015-09-22 11:01:20 -07:00

47 lines
1.7 KiB
XML

<?xml version='1.0' encoding='UTF-8'?>
<para xmlns="http://docbook.org/ns/docbook" version="5.0">
<!-- Warning: Do not edit this file. It is automatically
generated and your changes will be overwritten.
The tool to do so lives in openstack-doc-tools repository. -->
<table rules="all" xml:id="config_table_cinder_hpmsa">
<caption>Description of HP MSA volume driver configuration options</caption>
<col width="50%"/>
<col width="50%"/>
<thead>
<tr>
<th>Configuration option = Default value</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<th colspan="2">[DEFAULT]</th>
</tr>
<tr>
<td><option>hpmsa_api_protocol</option> = <replaceable>https</replaceable></td>
<td>(StrOpt) HPMSA API interface protocol.</td>
</tr>
<tr>
<td><option>hpmsa_backend_name</option> = <replaceable>A</replaceable></td>
<td>(StrOpt) Pool or Vdisk name to use for volume creation.</td>
</tr>
<tr>
<td><option>hpmsa_backend_type</option> = <replaceable>virtual</replaceable></td>
<td>(StrOpt) linear (for Vdisk) or virtual (for Pool).</td>
</tr>
<tr>
<td><option>hpmsa_iscsi_ips</option> = <replaceable></replaceable></td>
<td>(ListOpt) List of comma-separated target iSCSI IP addresses.</td>
</tr>
<tr>
<td><option>hpmsa_verify_certificate</option> = <replaceable>False</replaceable></td>
<td>(BoolOpt) Whether to verify HPMSA array SSL certificate.</td>
</tr>
<tr>
<td><option>hpmsa_verify_certificate_path</option> = <replaceable>None</replaceable></td>
<td>(StrOpt) HPMSA array SSL certificate path.</td>
</tr>
</tbody>
</table>
</para>