<section xml:id="emc-vnx-driver"
|
|
xmlns="http://docbook.org/ns/docbook"
|
|
xmlns:xi="http://www.w3.org/2001/XInclude"
|
|
xmlns:xlink="http://www.w3.org/1999/xlink" version="5.0">
|
|
<?dbhtml stop-chunking?>
|
|
<title>EMC VNX driver</title>
|
|
<para>EMC VNX driver consists of EMCCLIISCSIDriver
|
|
and EMCCLIFCDriver, and supports both iSCSI and FC protocol.
|
|
<literal>EMCCLIISCSIDriver</literal> (VNX iSCSI driver) and
|
|
<literal>EMCCLIFCDriver</literal> (VNX FC driver) are separately
|
|
based on the <literal>ISCSIDriver</literal> and <literal>FCDriver</literal>
|
|
defined in Block Storage.
|
|
</para>
|
|
<section xml:id="emc-vnx-overview">
|
|
<title>Overview</title>
|
|
<para>The VNX iSCSI driver and VNX FC driver perform the volume
|
|
operations by executing Navisphere CLI (NaviSecCLI)
|
|
which is a command line interface used for management, diagnostics, and reporting
|
|
functions for VNX.</para>
|
|
<section xml:id="emc-vnx-reqs">
|
|
<title>System requirements</title>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>VNX Operational Environment for Block version 5.32 or
|
|
higher.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>VNX Snapshot and Thin Provisioning license should be
|
|
activated for VNX.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Navisphere CLI v7.32 or higher is installed along with
|
|
the driver.</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
</section>
|
|
<section xml:id="emc-vnx-supported-ops">
|
|
<title>Supported operations</title>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>Create, delete, attach, and detach volumes.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Create, list, and delete volume snapshots.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Create a volume from a snapshot.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Copy an image to a volume.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Clone a volume.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Extend a volume.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Migrate a volume.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Retype a volume.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Get volume statistics.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Create and delete consistency groups.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Create, list, and delete consistency group snapshots.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Modify consistency groups.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Efficient non-disruptive volume backup.</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
</section>
|
|
</section>
|
|
<section xml:id="emc-vnx-prep">
|
|
<title>Preparation</title>
|
|
<para>This section contains instructions to prepare the Block Storage
|
|
nodes to use the EMC VNX driver. You install the Navisphere
|
|
CLI, install the driver, ensure you have correct zoning
|
|
configurations, and register the driver.</para>
|
|
<section xml:id="install-naviseccli">
|
|
<title>Install Navisphere CLI</title>
|
|
<para>Navisphere CLI needs to be installed on all Block Storage nodes
|
|
within an OpenStack deployment. You need to download different
|
|
versions for different platforms.</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>For Ubuntu x64, DEB is available at <link
|
|
xlink:href="https://github.com/emc-openstack/naviseccli">EMC
|
|
OpenStack Github</link>.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>For all other variants of Linux, Navisphere CLI is available at <link
|
|
xlink:href="https://support.emc.com/downloads/36656_VNX2-Series">
|
|
Downloads for VNX2 Series</link> or <link
|
|
xlink:href="https://support.emc.com/downloads/12781_VNX1-Series">
|
|
Downloads for VNX1 Series</link>.</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>After installation, set the security level of Navisphere CLI to low:</para>
|
|
<screen><prompt>$</prompt> <userinput
|
|
>/opt/Navisphere/bin/naviseccli security -certificate -setLevel low</userinput></screen>
|
|
</listitem>
|
|
</itemizedlist>
|
|
</section>
|
|
<section xml:id="check-array-software">
|
|
<title>Check array software</title>
|
|
<para>Make sure your have following software installed for certain features.</para>
|
|
<table rules="all">
|
|
<caption>Required software</caption>
|
|
<col width="50%"/>
|
|
<col width="50%"/>
|
|
<thead>
|
|
<tr>
|
|
<td>Feature</td>
|
|
<td>Software Required</td>
|
|
</tr>
|
|
</thead>
|
|
<tbody>
|
|
<tr>
|
|
<td><para>All</para></td>
|
|
<td><para>ThinProvisioning</para></td>
|
|
</tr>
|
|
<tr>
|
|
<td><para>All</para></td>
|
|
<td><para>VNXSnapshots</para></td>
|
|
</tr>
|
|
<tr>
|
|
<td><para>FAST cache support</para></td>
|
|
<td><para>FASTCache</para></td>
|
|
</tr>
|
|
<tr>
|
|
<td><para>Create volume with type <literal>compressed</literal></para></td>
|
|
<td><para>Compression</para></td>
|
|
</tr>
|
|
<tr>
|
|
<td><para>Create volume with type <literal>deduplicated</literal></para></td>
|
|
<td><para>Deduplication</para></td>
|
|
</tr>
|
|
</tbody>
|
|
</table>
|
|
<para>
|
|
You can check the status of your array software in the
|
|
"Software" page of "Storage System
|
|
Properties". Here is how it looks like.
|
|
</para>
|
|
<figure>
|
|
<title>Installed software on VNX</title>
|
|
<mediaobject>
|
|
<imageobject>
|
|
<imagedata fileref="../../../common/figures/emc/enabler.png"
|
|
contentwidth="6in"/>
|
|
</imageobject>
|
|
</mediaobject>
|
|
</figure>
|
|
</section>
|
|
<section xml:id="install-cinder-driver">
|
|
<title>Install EMC VNX driver</title>
|
|
<para>Both <literal>EMCCLIISCSIDriver</literal> and
|
|
<literal>EMCCLIFCDriver</literal> are included in the Block Storage
|
|
installer package:</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para><filename>emc_vnx_cli.py</filename></para>
|
|
</listitem>
|
|
<listitem>
|
|
<para><filename>emc_cli_fc.py</filename> (for
|
|
<option>EMCCLIFCDriver</option>)</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para><filename>emc_cli_iscsi.py</filename> (for
|
|
<option>EMCCLIISCSIDriver</option>)</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
</section>
|
|
<section xml:id="network-configuration">
|
|
<title>Network configuration</title>
|
|
<para>
|
|
For FC Driver, FC zoning is properly configured between hosts and
|
|
VNX. Check <xref linkend="register-fc-port-with-vnx"/> for
|
|
reference.
|
|
</para>
|
|
<para>
|
|
For iSCSI Driver, make sure your VNX iSCSI port is accessible by
|
|
your hosts. Check <xref linkend="register-iscsi-port-with-vnx"/> for
|
|
reference.
|
|
</para>
|
|
<para>
|
|
You can use <literal>initiator_auto_registration=True</literal>
|
|
configuration to avoid register the ports manually. Please check
|
|
the detail of the configuration in
|
|
<xref linkend="emc-vnx-conf"/> for reference.
|
|
</para>
|
|
<para>
|
|
If you are trying to setup multipath, please refer to
|
|
<emphasis>Multipath Setup</emphasis> in
|
|
<xref linkend="multipath-setup"/>.
|
|
</para>
|
|
</section>
|
|
</section>
|
|
<section xml:id="emc-vnx-conf">
|
|
<title>Backend configuration</title>
|
|
<para>Make the following changes in
|
|
<filename>/etc/cinder/cinder.conf</filename> file:</para>
|
|
<note>
|
|
<para>Changes to your configuration won't take
|
|
effect until your restart your cinder service.</para>
|
|
</note>
|
|
<section xml:id="minimum-configuration">
|
|
<title>Minimum configuration</title>
|
|
<para>
|
|
Here is a sample of minimum backend configuration. See following
|
|
sections for the detail of each option Replace
|
|
<literal>EMCCLIFCDriver</literal> to
|
|
<literal>EMCCLIISCSIDriver</literal> if your are using the iSCSI
|
|
driver.
|
|
</para>
|
|
<programlisting language="ini">[DEFAULT]
|
|
enabled_backends = vnx_array1
|
|
|
|
[vnx_array1]
|
|
san_ip = 10.10.72.41
|
|
san_login = sysadmin
|
|
san_password = sysadmin
|
|
naviseccli_path = /opt/Navisphere/bin/naviseccli
|
|
volume_driver=cinder.volume.drivers.emc.emc_cli_fc.EMCCLIFCDriver
|
|
initiator_auto_registration=True</programlisting>
|
|
</section>
|
|
<section xml:id="multi-backend-configuration">
|
|
<title>Multi-backend configuration</title>
|
|
<para>
|
|
Here is a sample of a multi-backend configuration. See following
|
|
sections for the detail of each option. Replace
|
|
<literal>EMCCLIFCDriver</literal> to
|
|
<literal>EMCCLIISCSIDriver</literal> if your are using the iSCSI
|
|
driver.
|
|
</para>
|
|
<programlisting language="ini">[DEFAULT]
|
|
enabled_backends=backendA, backendB
|
|
|
|
[backendA]
|
|
storage_vnx_pool_names = Pool_01_SAS, Pool_02_FLASH
|
|
san_ip = 10.10.72.41
|
|
storage_vnx_security_file_dir = /etc/secfile/array1
|
|
naviseccli_path = /opt/Navisphere/bin/naviseccli
|
|
volume_driver=cinder.volume.drivers.emc.emc_cli_fc.EMCCLIFCDriver
|
|
initiator_auto_registration=True
|
|
|
|
[backendB]
|
|
storage_vnx_pool_names = Pool_02_SAS
|
|
san_ip = 10.10.26.101
|
|
san_login = username
|
|
san_password = password
|
|
naviseccli_path = /opt/Navisphere/bin/naviseccli
|
|
volume_driver=cinder.volume.drivers.emc.emc_cli_fc.EMCCLIFCDriver
|
|
initiator_auto_registration=True</programlisting>
|
|
<para>
|
|
For more details on multi-backends, see
|
|
<link xlink:href="http://docs.openstack.org/admin-guide-cloud/index.html">OpenStack
|
|
Cloud Administration Guide</link>
|
|
</para>
|
|
</section>
|
|
<section xml:id="required-configurations">
|
|
<title>Required configurations</title>
|
|
<section xml:id="ip-of-the-vnx-storage-processors">
|
|
<title>IP of the VNX Storage Processors</title>
|
|
<para>
|
|
Specify the SP A and SP B IP to connect.
|
|
</para>
|
|
<programlisting language="ini">san_ip = <IP of VNX Storage Processor A>
|
|
san_secondary_ip = <IP of VNX Storage Processor B></programlisting>
|
|
</section>
|
|
<section xml:id="vnx-login-credentials">
|
|
<title>VNX login credentials</title>
|
|
<para>
|
|
There are two ways to specify the credentials.
|
|
</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
Use plain text username and password.
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<para>
|
|
Supply for plain username and password as below.
|
|
</para>
|
|
<programlisting language="ini">san_login = <VNX account with administrator role>
|
|
san_password = <password for VNX account>
|
|
storage_vnx_authentication_type = global</programlisting>
|
|
<para>
|
|
Valid values for
|
|
<literal>storage_vnx_authentication_type</literal> are:
|
|
<literal>global</literal> (default), <literal>local</literal>,
|
|
<literal>ldap</literal>
|
|
</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>Use Security file</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<para>
|
|
This approach avoids the plain text password in your cinder
|
|
configuration file. Supply a security file as below:
|
|
</para>
|
|
<programlisting language="ini">storage_vnx_security_file_dir=<path to security file></programlisting>
|
|
<para>Please check Unisphere CLI user guide or <xref linkend="authenticate-by-security-file"/>
|
|
for how to create a security file.</para>
|
|
</section>
|
|
<section xml:id="path-to-your-unisphere-cli">
|
|
<title>Path to your Unisphere CLI</title>
|
|
<para>
|
|
Specify the absolute path to your naviseccli.
|
|
</para>
|
|
<programlisting language="ini">naviseccli_path = /opt/Navisphere/bin/naviseccli</programlisting>
|
|
</section>
|
|
<section xml:id="driver-name">
|
|
<title>Driver name</title>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>For the FC Driver, add the following option:</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<programlisting language="ini">volume_driver=cinder.volume.drivers.emc.emc_cli_fc.EMCCLIFCDriver</programlisting>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>For iSCSI Driver, add following option:</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<programlisting language="ini">volume_driver=cinder.volume.drivers.emc.emc_cli_iscsi.EMCCLIISCSIDriver</programlisting>
|
|
</section>
|
|
</section>
|
|
<section xml:id="optional-configurations">
|
|
<title>Optional configurations</title>
|
|
<section xml:id="vnx-pool-names">
|
|
<title>VNX pool names</title>
|
|
<para>
|
|
Specify the list of pools to be managed, separated by ','. They
|
|
should already exist in VNX.
|
|
</para>
|
|
<programlisting language="ini">storage_vnx_pool_names = pool 1, pool 2</programlisting>
|
|
<para>
|
|
If this value is not specified, all pools of the array will be
|
|
used.
|
|
</para>
|
|
</section>
|
|
<section xml:id="initiator-auto-registration">
|
|
<title>Initiator auto registration</title>
|
|
<para>
|
|
When <literal>initiator_auto_registration=True</literal>, the
|
|
driver will automatically register initiators to all working
|
|
target ports of the VNX array during volume attaching (The
|
|
driver will skip those initiators that have already been
|
|
registered) if the option <literal>io_port_list</literal> is not
|
|
specified in cinder.conf.
|
|
</para>
|
|
<para>
|
|
If the user wants to register the initiators with some specific
|
|
ports but not register with the other ports, this functionality
|
|
should be disabled.
|
|
</para>
|
|
<para>
|
|
When a comma-separated list is given to
|
|
<literal>io_port_list</literal>, the driver will only register the
|
|
initiator to the ports specified in the list and only return
|
|
target port(s) which belong to the target ports in the
|
|
<literal>io_port_list</literal> instead of all target ports.
|
|
</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
Example for FC ports:
|
|
</para>
|
|
<programlisting language="ini">io_port_list=a-1,B-3</programlisting>
|
|
<para>
|
|
<literal>a</literal> or <literal>B</literal> is
|
|
<emphasis>Storage Processor</emphasis>, number
|
|
<literal>1</literal> and <literal>3</literal> are
|
|
<emphasis>Port ID</emphasis>.
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
Example for iSCSI ports:
|
|
</para>
|
|
<programlisting language="ini">io_port_list=a-1-0,B-3-0</programlisting>
|
|
<para>
|
|
<literal>a</literal> or <literal>B</literal> is
|
|
<emphasis>Storage Processor</emphasis>, the
|
|
first numbers <literal>1</literal> and <literal>3</literal>
|
|
are <emphasis>Port ID</emphasis> and the
|
|
second number <literal>0</literal> is
|
|
<emphasis>Virtual Port ID</emphasis>
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<note>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
Rather than de-registered, the registered ports will be
|
|
simply bypassed whatever they are in 'io_port_list' or not.
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
The driver will raise an exception if ports in
|
|
<literal>io_port_list</literal> are not existed in VNX
|
|
during startup.
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
</note>
|
|
</section>
|
|
<section xml:id="force-delete-volumes-in-storage-group">
|
|
<title>Force delete volumes in storage group</title>
|
|
<para>
|
|
Some <literal>available</literal> volumes may remain in storage
|
|
group on the VNX array due to some OpenStack timeout issue. But
|
|
the VNX array do not allow the user to delete the volumes which
|
|
are in storage group. Option
|
|
<literal>force_delete_lun_in_storagegroup</literal> is
|
|
introduced to allow the user to delete the
|
|
<literal>available</literal> volumes in this tricky situation.
|
|
</para>
|
|
<para>
|
|
When <literal>force_delete_lun_in_storagegroup=True</literal> in
|
|
the back-end section, the driver will move the volumes out of
|
|
storage groups and then delete them if the user tries to delete
|
|
the volumes that remain in storage group on the VNX array.
|
|
</para>
|
|
<para>
|
|
The default value of
|
|
<literal>force_delete_lun_in_storagegroup</literal> is
|
|
<literal>False</literal>.
|
|
</para>
|
|
</section>
|
|
<section xml:id="over-subscription-in-thin-provisioning">
|
|
<title>Over subscription in thin provisioning</title>
|
|
<para>
|
|
Over subscription allows that the sum of all volumes' capacity
|
|
(provisioned capacity) to be larger than the pool's total
|
|
capacity.
|
|
</para>
|
|
<para>
|
|
<literal>max_over_subscription_ratio</literal> in the back-end
|
|
section is the ratio of provisioned capacity over total
|
|
capacity.
|
|
</para>
|
|
<para>
|
|
The default value of
|
|
<literal>max_over_subscription_ratio</literal> is 20.0, which
|
|
means the provisioned capacity can not exceed the total
|
|
capacity. If the value of this ratio is set larger than 1.0, the
|
|
provisioned capacity can exceed the total capacity.
|
|
</para>
|
|
</section>
|
|
<section xml:id="storage-group-automatic-deletion">
|
|
<title>Storage group automatic deletion</title>
|
|
<para>
|
|
For volume attaching, the driver has a storage group on VNX for
|
|
each compute node hosting the vm instances which are going to
|
|
consume VNX Block Storage (using compute node's hostname as
|
|
storage group's name). All the volumes attached to the VM
|
|
instances in a compute node will be put into the storage group.
|
|
If <literal>destroy_empty_storage_group=True</literal>, the
|
|
driver will remove the empty storage group after its last volume
|
|
is detached. For data safety, it does not suggest to set
|
|
<literal>destroy_empty_storage_group=True</literal> unless the
|
|
VNX is exclusively managed by one Block Storage node because
|
|
consistent lock_path is required for operation synchronization
|
|
for this behavior.
|
|
</para>
|
|
</section>
|
|
<section xml:id="initiator-auto-deregistration">
|
|
<title>Initiator auto deregistration</title>
|
|
<para>
|
|
Enabling storage group automatic deletion is the precondition of
|
|
this function. If
|
|
<literal>initiator_auto_deregistration=True</literal> is set,
|
|
the driver will deregister all the initiators of the host after
|
|
its storage group is deleted.
|
|
</para>
|
|
</section>
|
|
<section xml:id="fc-san-auto-zoning">
|
|
<title>FC SAN auto zoning</title>
|
|
<para>
|
|
The EMC VNX FC driver supports FC SAN auto zoning when ZoneManager
|
|
is configured. Set <literal>zoning_mode</literal> to
|
|
<literal>fabric</literal> in <literal>DEFAULT</literal> section
|
|
to enable this feature. For ZoneManager configuration, please
|
|
refer to Block Storage official guide.
|
|
</para>
|
|
</section>
|
|
<section xml:id="volume-number-threshold">
|
|
<title>Volume number threshold</title>
|
|
<para>
|
|
In VNX, there is a limitation on the number of pool volumes that
|
|
can be created in the system. When the limitation is reached, no
|
|
more pool volumes can be created even if there is remaining
|
|
capacity in the storage pool. In other words, if the scheduler
|
|
dispatches a volume creation request to a back end that has free
|
|
capacity but reaches the volume limitation, the creation fails.
|
|
</para>
|
|
<para>
|
|
The default value of
|
|
<literal>check_max_pool_luns_threshold</literal> is
|
|
<literal>False</literal>. When
|
|
<literal>check_max_pool_luns_threshold=True</literal>, the
|
|
pool-based back end will check the limit and will report 0 free
|
|
capacity to the scheduler if the limit is reached. So the scheduler
|
|
will be able to skip this kind of pool-based back end that runs out
|
|
of the pool volume number.
|
|
</para>
|
|
</section>
|
|
<section xml:id="iscsi-initiators">
|
|
<title>iSCSI initiators</title>
|
|
<para>
|
|
<literal>iscsi_initiators</literal> is a dictionary of IP
|
|
addresses of the iSCSI initiator ports on OpenStack Nova/Cinder
|
|
nodes which want to connect to VNX via iSCSI. If this option is
|
|
configured, the driver will leverage this information to find an
|
|
accessible iSCSI target portal for the initiator when attaching
|
|
volume. Otherwise, the iSCSI target portal will be chosen in a
|
|
relative random way.
|
|
</para>
|
|
<para>
|
|
<emphasis>This option is only valid for iSCSI driver.</emphasis>
|
|
</para>
|
|
<para>
|
|
Here is an example. VNX will connect <literal>host1</literal>
|
|
with <literal>10.0.0.1</literal> and
|
|
<literal>10.0.0.2</literal>. And it will connect
|
|
<literal>host2</literal> with <literal>10.0.0.3</literal>.
|
|
</para>
|
|
<para>
|
|
The key name (like <literal>host1</literal> in the example)
|
|
should be the output of command <literal>hostname</literal>.
|
|
</para>
|
|
<programlisting language="ini">iscsi_initiators = {"host1":["10.0.0.1", "10.0.0.2"],"host2":["10.0.0.3"]}</programlisting>
|
|
</section>
|
|
<section xml:id="default-timeout">
|
|
<title>Default timeout</title>
|
|
<para>
|
|
Specify the timeout(minutes) for operations like LUN migration,
|
|
LUN creation, etc. For example, LUN migration is a typical long
|
|
running operation, which depends on the LUN size and the load of
|
|
the array. An upper bound in the specific deployment can be set
|
|
to avoid unnecessary long wait.
|
|
</para>
|
|
<para>
|
|
The default value for this option is infinite.
|
|
</para>
|
|
<para>
|
|
Example:
|
|
</para>
|
|
<programlisting language="ini">default_timeout = 10</programlisting>
|
|
</section>
|
|
<section xml:id="max-luns-per-storage-group">
|
|
<title>Max LUNs per storage group</title>
|
|
<para>
|
|
<literal>max_luns_per_storage_group</literal> specify the max
|
|
number of LUNs in a storage group. Default value is 255. It is
|
|
also the max value supportedby VNX.
|
|
</para>
|
|
</section>
|
|
<section xml:id="ignore-pool-full-threshold">
|
|
<title>Ignore pool full threshold</title>
|
|
<para>
|
|
if <literal>ignore_pool_full_threshold</literal> is set to
|
|
<literal>True</literal>, driver will force LUN creation even if
|
|
the full threshold of pool is reached. Default to
|
|
<literal>False</literal>
|
|
</para>
|
|
</section>
|
|
</section>
|
|
</section>
|
|
<section xml:id="emc-vnx-extra-spec">
|
|
<title>Extra spec options</title>
|
|
<para>
|
|
Extra specs are used in volume types created in cinder as the
|
|
preferred property of the volume.
|
|
</para>
|
|
<para>
|
|
The Block storage scheduler will use extra specs to find the suitable back end
|
|
for the volume and the Block storage driver will create the volume based on the
|
|
properties specified by the extra spec.
|
|
</para>
|
|
<para>
|
|
Use following command to create a volume type:
|
|
</para>
|
|
<screen><prompt>$</prompt> <userinput>cinder type-create "demoVolumeType"</userinput></screen>
|
|
<para>
|
|
Use following command to update the extra spec of a volume type:
|
|
</para>
|
|
<screen><prompt>$</prompt> <userinput>cinder type-key "demoVolumeType" set provisioning:type=thin</userinput></screen>
|
|
<para>
|
|
Volume types can also be configured in OpenStack Horizon.
|
|
</para>
|
|
<para>
|
|
In VNX Driver, we defined several extra specs. They are introduced
|
|
below:
|
|
</para>
|
|
<section xml:id="provisioning-type">
|
|
<title>Provisioning type</title>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
Key: <literal>provisioning:type</literal>
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
Possible Values:
|
|
</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
<literal>thick</literal>
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<para>
|
|
Volume is fully provisioned.
|
|
</para>
|
|
<example>
|
|
<title>creating a <literal>thick</literal> volume type:</title>
|
|
<screen><prompt>$</prompt> <userinput>cinder type-create "ThickVolumeType"</userinput>
|
|
<prompt>$</prompt> <userinput>cinder type-key "ThickVolumeType" set provisioning:type=thick thick_provisioning_support='<is> True'</userinput></screen>
|
|
</example>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
<literal>thin</literal>
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<para>
|
|
Volume is virtually provisioned
|
|
</para>
|
|
<example>
|
|
<title>creating a <literal>thin</literal> volume type:</title>
|
|
<screen><prompt>$</prompt> <userinput>cinder type-create "ThinVolumeType"</userinput>
|
|
<prompt>$</prompt> <userinput>cinder type-key "ThinVolumeType" set provisioning:type=thin thin_provisioning_support='<is> True'</userinput></screen>
|
|
</example>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
<literal>deduplicated</literal>
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<para>
|
|
Volume is <literal>thin</literal> and deduplication is
|
|
enabled. The administrator shall go to VNX to configure the
|
|
system level deduplication settings. To create a deduplicated
|
|
volume, the VNX Deduplication license must be activated on
|
|
VNX, and specify
|
|
<literal>deduplication_support=True</literal> to
|
|
let Block Storage scheduler find the proper volume back end.
|
|
</para>
|
|
<example>
|
|
<title>creating a <literal>deduplicated</literal> volume type:</title>
|
|
<screen><prompt>$</prompt> <userinput>cinder type-create "DeduplicatedVolumeType"</userinput>
|
|
<prompt>$</prompt> <userinput>cinder type-key "DeduplicatedVolumeType" set provisioning:type=deduplicated deduplication_support='<is> True'</userinput></screen>
|
|
</example>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
<literal>compressed</literal>
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<para>
|
|
Volume is <literal>thin</literal> and compression is enabled.
|
|
The administrator shall go to the VNX to configure the system
|
|
level compression settings. To create a compressed volume, the
|
|
VNX Compression license must be activated on VNX , and use
|
|
<literal>compression_support=True</literal> to
|
|
let Block Storage scheduler find a volume back end. VNX does
|
|
not support creating snapshots on a compressed volume.
|
|
</para>
|
|
<example>
|
|
<title>creating a <literal>compressed</literal> volume type:</title>
|
|
<screen><prompt>$</prompt> <userinput>cinder type-create "CompressedVolumeType"</userinput>
|
|
<prompt>$</prompt> <userinput>cinder type-key "CompressedVolumeType" set provisioning:type=compressed compression_support='<is> True'</userinput></screen>
|
|
</example>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
Default: <literal>thick</literal>
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<note>
|
|
<para><literal>provisioning:type</literal> replaces the old spec key
|
|
<literal>storagetype:provisioning</literal>. The latter one will
|
|
be obsoleted in the next release. If both <literal>provisioning:type</literal>and
|
|
<literal>storagetype:provisioning</literal> are set in the volume
|
|
type, the value of <literal>provisioning:type</literal> will be
|
|
used.</para>
|
|
</note>
|
|
</section>
|
|
<section xml:id="storage-tiering-support">
|
|
<title>Storage tiering support</title>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
Key: <literal>storagetype:tiering</literal>
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
Possible Values:
|
|
</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
<literal>StartHighThenAuto</literal>
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
<literal>Auto</literal>
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
<literal>HighestAvailable</literal>
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
<literal>LowestAvailable</literal>
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
<literal>NoMovement</literal>
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
Default: <literal>StartHighThenAuto</literal>
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<para>
|
|
VNX supports fully automated storage tiering which requires the
|
|
FAST license activated on the VNX. The OpenStack administrator can
|
|
use the extra spec key <literal>storagetype:tiering</literal> to
|
|
set the tiering policy of a volume and use the key
|
|
<literal>fast_support='<is> True'</literal> to let Block
|
|
Storage scheduler find a volume back end which manages a VNX with
|
|
FAST license activated. Here are the five supported values for the
|
|
extra spec key <literal>storagetype:tiering</literal>:
|
|
</para>
|
|
<example>
|
|
<title>creating a volume types with tiering policy:</title>
|
|
<screen><prompt>$</prompt> <userinput>cinder type-create "ThinVolumeOnLowestAvaibleTier"</userinput>
|
|
<prompt>$</prompt> <userinput>cinder type-key "CompressedVolumeOnLowestAvaibleTier" set provisioning:type=thin storagetype:tiering=Auto fast_support='<is> True'</userinput></screen>
|
|
</example>
|
|
<note>
|
|
<para>Tiering policy can not be applied to a deduplicated volume.
|
|
Tiering policy of the deduplicated LUN align with the settings of
|
|
the pool.</para>
|
|
</note>
|
|
</section>
|
|
<section xml:id="fast-cache-support">
|
|
<title>FAST cache support</title>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
Key: <literal>fast_cache_enabled</literal>
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
Possible Values:
|
|
</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
<literal>True</literal>
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
<literal>False</literal>
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
Default: <literal>False</literal>
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<para>
|
|
VNX has FAST Cache feature which requires the FAST Cache license
|
|
activated on the VNX. Volume will be created on the backend with
|
|
FAST cache enabled when <literal>True</literal> is specified.
|
|
</para>
|
|
</section>
|
|
<section xml:id="snap-copy">
|
|
<title>Snap-copy</title>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
Key: <literal>copytype:snap</literal>
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
Possible Values:
|
|
</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
<literal>True</literal>
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
<literal>False</literal>
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
Default: <literal>False</literal>
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<para>
|
|
The VNX driver supports snap-copy, which extremely accelerates the
|
|
process for creating a copied volume.
|
|
</para>
|
|
<para>
|
|
By default, the driver will do full data copy when creating a
|
|
volume from a snapshot or cloning a volume, which is
|
|
time-consuming especially for large volumes. When the snap-copy is
|
|
used, the driver will simply create a snapshot and mount it as a
|
|
volume for the 2 kinds of operations which will be instant even
|
|
for large volumes.
|
|
</para>
|
|
<para>
|
|
To enable this functionality, the source volume should have
|
|
<literal>copytype:snap=True</literal> in the extra specs of its
|
|
volume type. Then the new volume cloned from the source or copied
|
|
from the snapshot for the source, will be in fact a snap-copy
|
|
instead of a full copy. If a full copy is needed, retype/migration
|
|
can be used to convert the snap-copy volume to a full-copy volume
|
|
which may be time-consuming.
|
|
</para>
|
|
<screen><prompt>$</prompt> <userinput>cinder type-create "SnapCopy"</userinput>
|
|
<prompt>$</prompt> <userinput>cinder type-key "SnapCopy" set copytype:snap=True</userinput></screen>
|
|
<para>
|
|
User can determine whether the volume is a snap-copy volume or not
|
|
by showing its metadata. If the 'lun_type' in metadata is 'smp',
|
|
the volume is a snap-copy volume. Otherwise, it is a full-copy
|
|
volume.
|
|
</para>
|
|
<screen><prompt>$</prompt> <userinput>cinder metadata-show <volume></userinput></screen>
|
|
<para>
|
|
<emphasis>Constraints:</emphasis>
|
|
</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
<literal>copytype:snap=True</literal> is not allowed in the
|
|
volume type of a consistency group.
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
Clone and snapshot creation are not allowed on a copied volume
|
|
created through the snap-copy before it is converted to a full
|
|
copy.
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
The number of snap-copy volume created from a source volume is
|
|
limited to 255 at one point in time.
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
The source volume which has snap-copy volume can not be
|
|
deleted.
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
</section>
|
|
<section xml:id="pool-name">
|
|
<title>Pool name</title>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
Key: <literal>pool_name</literal>
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
Possible Values: name of the storage pool managed by cinder
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
Default: None
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<para>
|
|
If the user wants to create a volume on a certain storage pool in
|
|
a backend that manages multiple pools, a volume type with a extra
|
|
spec specified storage pool should be created first, then the user
|
|
can use this volume type to create the volume.
|
|
</para>
|
|
<example>
|
|
<title>Creating the volume type:</title>
|
|
<screen><prompt>$</prompt> <userinput>cinder type-create "HighPerf"</userinput>
|
|
<prompt>$</prompt> <userinput>cinder type-key "HighPerf" set pool_name=Pool_02_SASFLASH volume_backend_name=vnx_41</userinput></screen>
|
|
</example>
|
|
</section>
|
|
<section xml:id="obsoleted-extra-specs">
|
|
<title>Obsoleted extra specs in Liberty</title>
|
|
<para>
|
|
Please avoid using following extra spec keys.
|
|
</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
<literal>storagetype:provisioning</literal>
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
<literal>storagetype:pool</literal>
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
</section>
|
|
</section>
|
|
<section xml:id="emc-vnx-ad-features">
|
|
<title>Advanced features</title>
|
|
<section xml:id="read-only-volumes">
|
|
<title>Read-only volumes</title>
|
|
<para>
|
|
OpenStack supports read-only volumes. The following command can be
|
|
used to set a volume as read-only.
|
|
</para>
|
|
<screen><prompt>$</prompt> <userinput>cinder readonly-mode-update <volume> True</userinput></screen>
|
|
<para>
|
|
After a volume is marked as read-only, the driver will forward the
|
|
information when a hypervisor is attaching the volume and the
|
|
hypervisor will make sure the volume is read-only.
|
|
</para>
|
|
</section>
|
|
<section xml:id="efficient-non-disruptive-volume-backup">
|
|
<title>Efficient non-disruptive volume backup</title>
|
|
<para>
|
|
The default implementation in Cinder for non-disruptive volume
|
|
backup is not efficient since a cloned volume will be created
|
|
during backup.
|
|
</para>
|
|
<para>
|
|
The approach of efficient backup is to create a snapshot for the
|
|
volume and connect this snapshot (a mount point in VNX) to the
|
|
Cinder host for volume backup. This eliminates migration time
|
|
involved in volume clone.
|
|
</para>
|
|
<para>
|
|
<emphasis>Constraints:</emphasis>
|
|
</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
Backup creation for a snap-copy volume is not allowed if the
|
|
volume status is <literal>in-use</literal> since snapshot
|
|
cannot be taken from this volume.
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
</section>
|
|
</section>
|
|
<section xml:id="emc-vnx-best-practice">
|
|
<title>Best practice</title>
|
|
<section xml:id="multipath-setup">
|
|
<title>Multipath setup</title>
|
|
<para>
|
|
Enabling multipath volume access is recommended for robust data
|
|
access. The major configuration includes:
|
|
</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>
|
|
Install <literal>multipath-tools</literal>,
|
|
<literal>sysfsutils</literal> and <literal>sg3-utils</literal>
|
|
on nodes hosting Nova-Compute and Cinder-Volume services
|
|
(Please check the operating system manual for the system
|
|
distribution for specific installation steps. For Red Hat
|
|
based distributions, they should be
|
|
<literal>device-mapper-multipath</literal>,
|
|
<literal>sysfsutils</literal> and
|
|
<literal>sg3_utils</literal>).
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
Specify <literal>use_multipath_for_image_xfer=true</literal>
|
|
in cinder.conf for each FC/iSCSI back end.
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
Specify <literal>iscsi_use_multipath=True</literal> in
|
|
<literal>libvirt</literal> section of
|
|
<literal>nova.conf</literal>. This option is valid for both
|
|
iSCSI and FC driver.
|
|
</para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
<para>
|
|
For multipath-tools, here is an EMC recommended sample of
|
|
<filename>/etc/multipath.conf</filename>.
|
|
</para>
|
|
<para>
|
|
<literal>user_friendly_names</literal> is not specified in the
|
|
configuration and thus it will take the default value
|
|
<literal>no</literal>. It is NOT recommended to set it to
|
|
<literal>yes</literal> because it may fail operations such as VM
|
|
live migration.
|
|
</para>
|
|
<programlisting language="ini">blacklist {
|
|
# Skip the files under /dev that are definitely not FC/iSCSI devices
|
|
# Different system may need different customization
|
|
devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*"
|
|
devnode "^hd[a-z][0-9]*"
|
|
devnode "^cciss!c[0-9]d[0-9]*[p[0-9]*]"
|
|
|
|
# Skip LUNZ device from VNX
|
|
device {
|
|
vendor "DGC"
|
|
product "LUNZ"
|
|
}
|
|
}
|
|
|
|
defaults {
|
|
user_friendly_names no
|
|
flush_on_last_del yes
|
|
}
|
|
|
|
devices {
|
|
# Device attributed for EMC CLARiiON and VNX series ALUA
|
|
device {
|
|
vendor "DGC"
|
|
product ".*"
|
|
product_blacklist "LUNZ"
|
|
path_grouping_policy group_by_prio
|
|
path_selector "round-robin 0"
|
|
path_checker emc_clariion
|
|
features "1 queue_if_no_path"
|
|
hardware_handler "1 alua"
|
|
prio alua
|
|
failback immediate
|
|
}
|
|
}</programlisting>
|
|
<note>
|
|
<para>When multipath is used in OpenStack, multipath faulty devices may
|
|
come out in Nova-Compute nodes due to different issues
|
|
(<link xlink:href="https://bugs.launchpad.net/nova/+bug/1336683">Bug
|
|
1336683</link> is a typical example).</para>
|
|
</note>
|
|
<para>
|
|
A solution to completely avoid faulty devices has not been found
|
|
yet. <literal>faulty_device_cleanup.py</literal> mitigates this
|
|
issue when VNX iSCSI storage is used. Cloud administrators can
|
|
deploy the script in all Nova-Compute nodes and use a CRON job to
|
|
run the script on each Nova-Compute node periodically so that
|
|
faulty devices will not stay too long. Please refer to:
|
|
<link xlink:href="https://github.com/emc-openstack/vnx-faulty-device-cleanup">
|
|
VNX faulty device cleanup</link> for detailed usage and the script.
|
|
</para>
|
|
</section>
|
|
</section>
|
|
<section xml:id="emc-vnx-limitation">
|
|
<title>Restrictions and limitations</title>
|
|
<section xml:id="iscsi-port-cache">
|
|
<title>iSCSI port cache</title>
|
|
<para>
|
|
EMC VNX iSCSI driver caches the iSCSI ports information, so that
|
|
the user should restart the cinder-volume service or wait for
|
|
seconds (which is configured by
|
|
<literal>periodic_interval</literal> in
|
|
<filename>cinder.conf</filename>) before any volume attachment
|
|
operation after changing the iSCSI port configurations. Otherwise
|
|
the attachment may fail because the old iSCSI port configurations
|
|
were used.
|
|
</para>
|
|
</section>
|
|
<section xml:id="no-extending-for-volume-with-snapshots">
|
|
<title>No extending for volume with snapshots</title>
|
|
<para>
|
|
VNX does not support extending the thick volume which has a
|
|
snapshot. If the user tries to extend a volume which has a
|
|
snapshot, the status of the volume would change to
|
|
<literal>error_extending</literal>.
|
|
</para>
|
|
</section>
|
|
<section xml:id="limitations-for-deploying-cinder-on-computer-node">
|
|
<title>Limitations for deploying cinder on computer node</title>
|
|
<para>
|
|
It is not recommended to deploy the driver on a compute node if
|
|
<literal>cinder upload-to-image --force True</literal> is used
|
|
against an in-use volume. Otherwise,
|
|
<literal>cinder upload-to-image --force True</literal> will
|
|
terminate the data access of the vm instance to the volume.
|
|
</para>
|
|
</section>
|
|
<section xml:id="storage-group-with-host-names-in-vnx">
|
|
<title>Storage group with host names in VNX</title>
|
|
<para>
|
|
When the driver notices that there is no existing storage group
|
|
that has the host name as the storage group name, it will create
|
|
the storage group and also add the compute node's or Block Storage
|
|
nodes' registered initiators into the storage group.
|
|
</para>
|
|
<para>
|
|
If the driver notices that the storage group already exists, it
|
|
will assume that the registered initiators have also been put into
|
|
it and skip the operations above for better performance.
|
|
</para>
|
|
<para>
|
|
It is recommended that the storage administrator does not create
|
|
the storage group manually and instead relies on the driver for
|
|
the preparation. If the storage administrator needs to create the
|
|
storage group manually for some special requirements, the correct
|
|
registered initiators should be put into the storage group as well
|
|
(otherwise the following volume attaching operations will fail ).
|
|
</para>
|
|
</section>
|
|
<section xml:id="emc-storage-assisted-volume-migration">
|
|
<title>EMC storage-assisted volume migration</title>
|
|
<para>
|
|
EMC VNX driver supports storage-assisted volume migration, when
|
|
the user starts migrating with
|
|
<literal>cinder migrate --force-host-copy False <volume_id> <host></literal>
|
|
or
|
|
<literal>cinder migrate <volume_id> <host></literal>,
|
|
cinder will try to leverage the VNX's native volume migration
|
|
functionality.
|
|
</para>
|
|
<para>
|
|
In following scenarios, VNX storage-assisted volume migration will
|
|
not be triggered:
|
|
</para>
|
|
<orderedlist numeration="arabic">
|
|
<listitem>
|
|
<para>
|
|
Volume migration between back ends with different storage
|
|
protocol, ex, FC and iSCSI.
|
|
</para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>
|
|
Volume is to be migrated across arrays.
|
|
</para>
|
|
</listitem>
|
|
</orderedlist>
|
|
</section>
|
|
</section>
|
|
<section xml:id="emc-vnx-appendix">
|
|
<title>Appendix</title>
|
|
<section xml:id="authenticate-by-security-file">
|
|
<title>Authenticate by security file</title>
|
|
<para>
|
|
VNX credentials are necessary when the driver connects to the VNX
|
|
system. Credentials in global, local and ldap scopes are
|
|
supported. There are two approaches to provide the credentials:
|
|
</para>
|
|
<para>
|
|
The recommended one is using the Navisphere CLI security file to
|
|
provide the credentials which can get rid of providing the plain
|
|
text credentials in the configuration file. Following is the
|
|
instruction on how to do this.
|
|
</para>
|
|
<procedure>
|
|
<step>
|
|
<para>
|
|
Find out the Linux user id of the
|
|
<systemitem class="service">cinder-volume</systemitem> processes. Assuming
|
|
the service <systemitem class="service">cinder-volume</systemitem> is running
|
|
by the account <literal>cinder</literal>.
|
|
</para>
|
|
</step>
|
|
<step>
|
|
<para>
|
|
Run <literal>su</literal> as root user.
|
|
</para>
|
|
</step>
|
|
<step>
|
|
<para>
|
|
In <filename>/etc/passwd</filename>, change
|
|
<literal>cinder:x:113:120::/var/lib/cinder:/bin/false</literal>
|
|
to
|
|
<literal>cinder:x:113:120::/var/lib/cinder:/bin/bash</literal>
|
|
(This temporary change is to make step 4 work.)
|
|
</para>
|
|
</step>
|
|
<step>
|
|
<para>
|
|
Save the credentials on behave of <literal>cinder</literal>
|
|
user to a security file (assuming the array credentials are
|
|
<literal>admin/admin</literal> in <literal>global</literal>
|
|
scope). In the command below, the '-secfilepath' switch is
|
|
used to specify the location to save the security file.
|
|
</para>
|
|
<screen><prompt>#</prompt> <userinput>su -l cinder -c '/opt/Navisphere/bin/naviseccli -AddUserSecurity -user admin -password admin -scope 0 -secfilepath <location>'</userinput></screen>
|
|
</step>
|
|
<step>
|
|
<para>
|
|
Change
|
|
<literal>cinder:x:113:120::/var/lib/cinder:/bin/bash</literal>
|
|
back to
|
|
<literal>cinder:x:113:120::/var/lib/cinder:/bin/false</literal>
|
|
in <literal>/etc/passwd</literal>
|
|
</para>
|
|
</step>
|
|
<step>
|
|
<para>
|
|
Remove the credentials options <literal>san_login</literal>,
|
|
<literal>san_password</literal> and
|
|
<literal>storage_vnx_authentication_type</literal> from
|
|
cinder.conf. (normally it is
|
|
<filename>/etc/cinder/cinder.conf</filename>). Add option
|
|
<literal>storage_vnx_security_file_dir</literal> and set its
|
|
value to the directory path of your security file generated in
|
|
step 4. Omit this option if <literal>-secfilepath</literal> is
|
|
not used in step 4.
|
|
</para>
|
|
</step>
|
|
<step>
|
|
<para>
|
|
Restart the <systemitem class="service">cinder-volume</systemitem> service
|
|
to validate the change.
|
|
</para>
|
|
</step>
|
|
</procedure>
|
|
</section>
|
|
<section xml:id="register-fc-port-with-vnx">
|
|
<title>Register FC port with VNX</title>
|
|
<para>
|
|
This configuration is only required when
|
|
<literal>initiator_auto_registration=False</literal>.
|
|
</para>
|
|
<para>
|
|
To access VNX storage, the compute nodes should be registered on
|
|
VNX first if initiator auto registration is not enabled.
|
|
</para>
|
|
<para>
|
|
To perform "Copy Image to Volume" and "Copy Volume
|
|
to Image" operations, the nodes running the
|
|
<systemitem class="service">cinder-volume</systemitem>
|
|
service (Block Storage nodes) must be registered with the VNX as
|
|
well.
|
|
</para>
|
|
<para>
|
|
The steps mentioned below are for the compute nodes. Please follow
|
|
the same steps for the Block Storage nodes also (The steps can be
|
|
skipped if initiator auto registration is enabled).
|
|
</para>
|
|
<procedure>
|
|
<step>
|
|
<para>Assume <literal>20:00:00:24:FF:48:BA:C2:21:00:00:24:FF:48:BA:C2</literal>
|
|
is the WWN of a FC initiator port name of the compute node whose
|
|
hostname and IP are <literal>myhost1</literal> and
|
|
<literal>10.10.61.1</literal>. Register
|
|
<literal>20:00:00:24:FF:48:BA:C2:21:00:00:24:FF:48:BA:C2</literal>
|
|
in Unisphere:</para>
|
|
<substeps>
|
|
<step><para>Login to Unisphere, go to
|
|
<guibutton>FNM0000000000->Hosts->Initiators</guibutton>.
|
|
</para></step>
|
|
<step><para>Refresh and wait until the initiator <literal>
|
|
20:00:00:24:FF:48:BA:C2:21:00:00:24:FF:48:BA:C2</literal>
|
|
with SP Port <literal>A-1</literal> appears.</para></step>
|
|
<step><para>Click the <guibutton>Register</guibutton> button,
|
|
select <guilabel>CLARiiON/VNX</guilabel> and enter the
|
|
hostname (which is the output of the linux command <literal>
|
|
hostname</literal>) and IP address:</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>Hostname : <literal>myhost1</literal></para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>IP : <literal>10.10.61.1</literal></para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Click <guibutton>Register</guibutton></para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
</step>
|
|
<step><para>Then host <literal>10.10.61.1</literal> will
|
|
appear under <guibutton>Hosts->Host List</guibutton>
|
|
as well.</para></step>
|
|
</substeps>
|
|
</step>
|
|
<step><para>Register the wwn with more ports if needed.</para></step>
|
|
</procedure>
|
|
</section>
|
|
<section xml:id="register-iscsi-port-with-vnx">
|
|
<title>Register iSCSI port with VNX</title>
|
|
<para>
|
|
This configuration is only required when
|
|
<literal>initiator_auto_registration=False</literal>.
|
|
</para>
|
|
<para>
|
|
To access VNX storage, the compute nodes should be registered on
|
|
VNX first if initiator auto registration is not enabled.
|
|
</para>
|
|
<para>
|
|
To perform "Copy Image to Volume" and "Copy Volume
|
|
to Image" operations, the nodes running the cinder-volume
|
|
service (Block Storage nodes) must be registered with the VNX as
|
|
well.
|
|
</para>
|
|
<para>
|
|
The steps mentioned below are for the compute nodes. Please follow
|
|
the same steps for the Block Storage nodes also (The steps can be
|
|
skipped if initiator auto registration is enabled).
|
|
</para>
|
|
<procedure>
|
|
<step><para>On the compute node with IP address
|
|
<literal>10.10.61.1</literal> and hostname <literal>myhost1</literal>,
|
|
execute the following commands (assuming <literal>10.10.61.35</literal>
|
|
is the iSCSI target):</para>
|
|
<substeps>
|
|
<step><para>Start the iSCSI initiator service on the node</para>
|
|
<screen><prompt>#</prompt> <userinput
|
|
>/etc/init.d/open-iscsi start</userinput></screen></step>
|
|
<step><para>Discover the iSCSI target portals on VNX</para>
|
|
<screen><prompt>#</prompt> <userinput
|
|
>iscsiadm -m discovery -t st -p 10.10.61.35</userinput></screen></step>
|
|
<step><para>Enter <filename>/etc/iscsi</filename></para>
|
|
<screen><prompt>#</prompt> <userinput
|
|
>cd /etc/iscsi</userinput></screen></step>
|
|
<step><para>Find out the iqn of the node</para>
|
|
<screen><prompt>#</prompt> <userinput
|
|
>more initiatorname.iscsi</userinput></screen></step>
|
|
</substeps>
|
|
</step>
|
|
<step><para>Login to VNX from the compute node using the
|
|
target corresponding to the SPA port:</para>
|
|
<screen><prompt>#</prompt> <userinput
|
|
>iscsiadm -m node -T iqn.1992-04.com.emc:cx.apm01234567890.a0 -p 10.10.61.35 -l</userinput></screen>
|
|
</step>
|
|
<step><para>Assume <literal>iqn.1993-08.org.debian:01:1a2b3c4d5f6g</literal>
|
|
is the initiator name of the compute node. Register
|
|
<literal>iqn.1993-08.org.debian:01:1a2b3c4d5f6g</literal> in
|
|
Unisphere:</para>
|
|
<substeps>
|
|
<step><para>Login to Unisphere, go to
|
|
<guibutton>FNM0000000000->Hosts->Initiators
|
|
</guibutton>.</para></step>
|
|
<step><para>Refresh and wait until the initiator
|
|
<literal>iqn.1993-08.org.debian:01:1a2b3c4d5f6g</literal>
|
|
with SP Port <literal>A-8v0</literal> appears.</para></step>
|
|
<step><para>Click the <guibutton>Register</guibutton> button,
|
|
select <guilabel>CLARiiON/VNX</guilabel> and enter the
|
|
hostname (which is the output of the linux command <literal>
|
|
hostname</literal>) and IP address:</para>
|
|
<itemizedlist>
|
|
<listitem>
|
|
<para>Hostname : <literal>myhost1</literal></para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>IP : <literal>10.10.61.1</literal></para>
|
|
</listitem>
|
|
<listitem>
|
|
<para>Click <guibutton>Register</guibutton></para>
|
|
</listitem>
|
|
</itemizedlist>
|
|
</step>
|
|
<step><para>Then host <literal>10.10.61.1</literal> will
|
|
appear under <guibutton>Hosts->Host List</guibutton>
|
|
as well.</para></step>
|
|
</substeps>
|
|
</step>
|
|
<step><para>Logout iSCSI on the node:</para>
|
|
<screen><prompt>#</prompt> <userinput
|
|
>iscsiadm -m node -u</userinput></screen>
|
|
</step>
|
|
<step><para>Login to VNX from the compute node using the
|
|
target corresponding to the SPB port:</para>
|
|
<screen><prompt>#</prompt> <userinput
|
|
>iscsiadm -m node -T iqn.1992-04.com.emc:cx.apm01234567890.b8 -p 10.10.61.36 -l</userinput></screen>
|
|
</step>
|
|
<step><para>In Unisphere register the initiator with the
|
|
SPB port.</para></step>
|
|
<step><para>Logout iSCSI on the node:</para>
|
|
<screen><prompt>#</prompt> <userinput
|
|
>iscsiadm -m node -u</userinput></screen>
|
|
</step>
|
|
<step><para>Register the iqn with more ports if needed.</para></step>
|
|
</procedure>
|
|
</section>
|
|
</section>
|
|
</section>
|