ofp_handler: Handle empty data field in OFPErrorMsg
OpenFlow Spec defines that the data field should contain at least 64 bytes of the failed request that caused the error message to be generated, unless otherwise specified. But, the data field can be empty in some switch implementation, this patch checks the data field length and skips parsing it if the field does not contain enough bytes to parse. Reported-by: Yury Yurochko <y.yurochko@brain4net.com> Signed-off-by: IWASE Yusuke <iwase.yusuke0@gmail.com> Signed-off-by: FUJITA Tomonori <fujita.tomonori@lab.ntt.co.jp>
This commit is contained in:
parent
51fcda83b5
commit
7b5d6bd24a
@ -243,22 +243,29 @@ class OFPHandler(ryu.base.app_manager.RyuApp):
|
||||
def error_msg_handler(self, ev):
|
||||
msg = ev.msg
|
||||
ofp = msg.datapath.ofproto
|
||||
(version, msg_type, msg_len, xid) = ofproto_parser.header(msg.data)
|
||||
self.logger.debug('EventOFPErrorMsg received.')
|
||||
self.logger.debug(
|
||||
'version=%s, msg_type=%s, msg_len=%s, xid=%s', hex(msg.version),
|
||||
hex(msg.msg_type), hex(msg.msg_len), hex(msg.xid))
|
||||
self.logger.debug(
|
||||
' `-- msg_type: %s', ofp.ofp_msg_type_to_str(msg.msg_type))
|
||||
self.logger.debug(
|
||||
"OFPErrorMsg(type=%s, code=%s, data=b'%s')", hex(msg.type),
|
||||
hex(msg.code), utils.binary_str(msg.data))
|
||||
self.logger.debug(
|
||||
' |-- type: %s', ofp.ofp_error_type_to_str(msg.type))
|
||||
self.logger.debug(
|
||||
' |-- code: %s', ofp.ofp_error_code_to_str(msg.type, msg.code))
|
||||
self.logger.debug(
|
||||
' `-- data: version=%s, msg_type=%s, msg_len=%s, xid=%s',
|
||||
hex(version), hex(msg_type), hex(msg_len), hex(xid))
|
||||
self.logger.debug(
|
||||
' `-- msg_type: %s', ofp.ofp_msg_type_to_str(msg_type))
|
||||
"EventOFPErrorMsg received.\n"
|
||||
"version=%s, msg_type=%s, msg_len=%s, xid=%s\n"
|
||||
" `-- msg_type: %s\n"
|
||||
"OFPErrorMsg(type=%s, code=%s, data=b'%s')\n"
|
||||
" |-- type: %s\n"
|
||||
" |-- code: %s",
|
||||
hex(msg.version), hex(msg.msg_type), hex(msg.msg_len),
|
||||
hex(msg.xid), ofp.ofp_msg_type_to_str(msg.msg_type),
|
||||
hex(msg.type), hex(msg.code), utils.binary_str(msg.data),
|
||||
ofp.ofp_error_type_to_str(msg.type),
|
||||
ofp.ofp_error_code_to_str(msg.type, msg.code))
|
||||
if len(msg.data) >= ofp.OFP_HEADER_SIZE:
|
||||
(version, msg_type, msg_len, xid) = ofproto_parser.header(msg.data)
|
||||
self.logger.debug(
|
||||
" `-- data: version=%s, msg_type=%s, msg_len=%s, xid=%s\n"
|
||||
" `-- msg_type: %s",
|
||||
hex(version), hex(msg_type), hex(msg_len), hex(xid),
|
||||
ofp.ofp_msg_type_to_str(msg_type))
|
||||
else:
|
||||
self.logger.warning(
|
||||
"The data field sent from the switch is too short: "
|
||||
"len(msg.data) < OFP_HEADER_SIZE\n"
|
||||
"The OpenFlow Spec says that the data field should contain "
|
||||
"at least 64 bytes of the failed request.\n"
|
||||
"Please check the settings or implementation of your switch.")
|
||||
|
Loading…