diff --git a/ryu/flags.py b/ryu/flags.py index 7c50e697..225cbbb4 100644 --- a/ryu/flags.py +++ b/ryu/flags.py @@ -55,6 +55,24 @@ CONF.register_cli_opts([ # tests/switch/tester cfg.StrOpt('target', default='0000000000000001', help='target sw dp-id'), cfg.StrOpt('tester', default='0000000000000002', help='tester sw dp-id'), + cfg.IntOpt('target_recv_port', default=1, + help='target sw receiving port ' + '(default: 1)'), + cfg.IntOpt('target_send_port_1', default=2, + help='target sw sending port 1 ' + '(default: 2)'), + cfg.IntOpt('target_send_port_2', default=3, + help='target sw sending port 2 ' + '(default: 3)'), + cfg.IntOpt('tester_send_port', default=1, + help='tester sw sending port ' + '(default: 1)'), + cfg.IntOpt('tester_recv_port_1', default=2, + help='tester sw receiving port 1 ' + '(default: 2)'), + cfg.IntOpt('tester_recv_port_2', default=3, + help='tester sw receiving port 2 ' + '(default: 3)'), cfg.StrOpt('dir', default='ryu/tests/switch/of13', help='test files directory'), cfg.StrOpt('target-version', default='openflow13', diff --git a/ryu/tests/switch/tester.py b/ryu/tests/switch/tester.py index b6826e56..6508bec7 100644 --- a/ryu/tests/switch/tester.py +++ b/ryu/tests/switch/tester.py @@ -81,11 +81,6 @@ CONF = cfg.CONF # Default settings. -TESTER_SENDER_PORT = 1 -TESTER_RECEIVE_PORT = 2 -TARGET_SENDER_PORT = 2 -TARGET_RECEIVE_PORT = 1 - INTERVAL = 1 # sec WAIT_TIMER = 3 # sec CONTINUOUS_THREAD_INTVL = float(0.01) # sec @@ -265,7 +260,13 @@ class OfTester(app_manager.RyuApp): self._set_logger() self.target_dpid = self._convert_dpid(CONF['test-switch']['target']) + self.target_send_port_1 = CONF['test-switch']['target_send_port_1'] + self.target_send_port_2 = CONF['test-switch']['target_send_port_2'] + self.target_recv_port = CONF['test-switch']['target_recv_port'] self.tester_dpid = self._convert_dpid(CONF['test-switch']['tester']) + self.tester_send_port = CONF['test-switch']['tester_send_port'] + self.tester_recv_port_1 = CONF['test-switch']['tester_recv_port_1'] + self.tester_recv_port_2 = CONF['test-switch']['tester_recv_port_2'] self.logger.info('target_dpid=%s', dpid_lib.dpid_to_str(self.target_dpid)) self.logger.info('tester_dpid=%s', @@ -363,7 +364,7 @@ class OfTester(app_manager.RyuApp): else: self.tester_sw.dp = dp self.tester_sw.add_flow( - in_port=TESTER_RECEIVE_PORT, + in_port=self.tester_recv_port_1, out_port=dp.ofproto.OFPP_CONTROLLER) msg = 'Join tester SW.' else: @@ -712,14 +713,17 @@ class OfTester(app_manager.RyuApp): def _test_no_pktin_reason_check(self, test_type, target_pkt_count, tester_pkt_count): - before_target_receive = target_pkt_count[0][TARGET_RECEIVE_PORT]['rx'] - before_target_send = target_pkt_count[0][TARGET_SENDER_PORT]['tx'] - before_tester_receive = tester_pkt_count[0][TESTER_RECEIVE_PORT]['rx'] - before_tester_send = tester_pkt_count[0][TESTER_SENDER_PORT]['tx'] - after_target_receive = target_pkt_count[1][TARGET_RECEIVE_PORT]['rx'] - after_target_send = target_pkt_count[1][TARGET_SENDER_PORT]['tx'] - after_tester_receive = tester_pkt_count[1][TESTER_RECEIVE_PORT]['rx'] - after_tester_send = tester_pkt_count[1][TESTER_SENDER_PORT]['tx'] + before_target_receive = target_pkt_count[ + 0][self.target_recv_port]['rx'] + before_target_send = target_pkt_count[0][self.target_send_port_1]['tx'] + before_tester_receive = tester_pkt_count[ + 0][self.tester_recv_port_1]['rx'] + before_tester_send = tester_pkt_count[0][self.tester_send_port]['tx'] + after_target_receive = target_pkt_count[1][self.target_recv_port]['rx'] + after_target_send = target_pkt_count[1][self.target_send_port_1]['tx'] + after_tester_receive = tester_pkt_count[ + 1][self.tester_recv_port_1]['rx'] + after_tester_send = tester_pkt_count[1][self.tester_send_port]['tx'] if after_tester_send == before_tester_send: log_msg = 'no change in tx_packets on tester.' @@ -1121,10 +1125,12 @@ class OfTester(app_manager.RyuApp): class OpenFlowSw(object): + def __init__(self, dp, logger): super(OpenFlowSw, self).__init__() self.dp = dp self.logger = logger + self.tester_send_port = CONF['test-switch']['tester_send_port'] def send_msg(self, msg): if isinstance(self.dp, DummyDatapath): @@ -1229,7 +1235,7 @@ class OpenFlowSw(object): """ send a PacketOut message.""" ofp = self.dp.ofproto parser = self.dp.ofproto_parser - actions = [parser.OFPActionOutput(TESTER_SENDER_PORT)] + actions = [parser.OFPActionOutput(self.tester_send_port)] out = parser.OFPPacketOut( datapath=self.dp, buffer_id=ofp.OFP_NO_BUFFER, data=data, in_port=ofp.OFPP_CONTROLLER, actions=actions) @@ -1272,6 +1278,27 @@ class TestFile(stringify.StringifyMixin): self.tests = [] self._get_tests(path) + def _normalize_test_json(self, val): + def __replace_port_name(k, v): + for port_name in [ + 'target_recv_port', 'target_send_port_1', + 'target_send_port_2', 'tester_send_port', + 'tester_recv_port_1', 'tester_recv_port_2']: + if v[k] == port_name: + v[k] = CONF['test-switch'][port_name] + if isinstance(val, dict): + for k, v in val.iteritems(): + if k == "OFPActionOutput": + if 'port' in v: + __replace_port_name("port", v) + elif k == "OXMTlv": + if v.get("field", "") == "in_port": + __replace_port_name("value", v) + self._normalize_test_json(v) + elif isinstance(val, list): + for v in val: + self._normalize_test_json(v) + def _get_tests(self, path): with open(path, 'rb') as fhandle: buf = fhandle.read() @@ -1281,6 +1308,7 @@ class TestFile(stringify.StringifyMixin): if isinstance(test_json, unicode): self.description = test_json else: + self._normalize_test_json(test_json) self.tests.append(Test(test_json)) except (ValueError, TypeError) as e: result = (TEST_FILE_ERROR %