Validate protocols using parameter types
Parameters types is better way to enforce specific values because it's implemented at the interface level. This offloads some of the validations we have in manifest logics because we already started using parameter types. Change-Id: I93f1bdae811a999bbbc55861d9e2c7500d347c22
This commit is contained in:
parent
aaadd0ec50
commit
bec5c873e4
@ -59,24 +59,19 @@ define cinder::backend::dellemc_powermax (
|
||||
$powermax_array,
|
||||
$powermax_srp,
|
||||
$powermax_port_groups,
|
||||
$powermax_storage_protocol = 'iSCSI',
|
||||
$volume_backend_name = $name,
|
||||
$backend_availability_zone = $facts['os_service_default'],
|
||||
Hash $extra_options = {},
|
||||
Boolean $manage_volume_type = false,
|
||||
Enum['iSCSI', 'FC'] $powermax_storage_protocol = 'iSCSI',
|
||||
$volume_backend_name = $name,
|
||||
$backend_availability_zone = $facts['os_service_default'],
|
||||
Hash $extra_options = {},
|
||||
Boolean $manage_volume_type = false,
|
||||
) {
|
||||
|
||||
include cinder::deps
|
||||
include cinder::params
|
||||
|
||||
if $powermax_storage_protocol == 'iSCSI' {
|
||||
$volume_driver = 'cinder.volume.drivers.dell_emc.powermax.iscsi.PowerMaxISCSIDriver'
|
||||
}
|
||||
elsif $powermax_storage_protocol == 'FC' {
|
||||
$volume_driver = 'cinder.volume.drivers.dell_emc.powermax.fc.PowerMaxFCDriver'
|
||||
}
|
||||
else {
|
||||
fail('The cinder::backend::dellemc_powermax powermax_storage_protocol specified is not valid. It should be iSCSI or FC')
|
||||
$volume_driver = $powermax_storage_protocol ? {
|
||||
'FC' => 'cinder.volume.drivers.dell_emc.powermax.fc.PowerMaxFCDriver',
|
||||
default => 'cinder.volume.drivers.dell_emc.powermax.iscsi.PowerMaxISCSIDriver',
|
||||
}
|
||||
|
||||
$_powermax_port_groups = join(any2array($powermax_port_groups), ',')
|
||||
|
@ -46,25 +46,17 @@ define cinder::backend::dellemc_powerstore (
|
||||
$san_ip,
|
||||
$san_login,
|
||||
$san_password,
|
||||
$powerstore_ports = $facts['os_service_default'],
|
||||
$storage_protocol = 'iSCSI',
|
||||
$volume_backend_name = $name,
|
||||
$backend_availability_zone = $facts['os_service_default'],
|
||||
Boolean $manage_volume_type = false,
|
||||
Hash $extra_options = {},
|
||||
$powerstore_ports = $facts['os_service_default'],
|
||||
Enum['iSCSI', 'FC'] $storage_protocol = 'iSCSI',
|
||||
$volume_backend_name = $name,
|
||||
$backend_availability_zone = $facts['os_service_default'],
|
||||
Boolean $manage_volume_type = false,
|
||||
Hash $extra_options = {},
|
||||
) {
|
||||
|
||||
include cinder::deps
|
||||
|
||||
if $storage_protocol == 'iSCSI' {
|
||||
$driver = 'dell_emc.powerstore.driver.PowerStoreDriver'
|
||||
}
|
||||
elsif $storage_protocol == 'FC' {
|
||||
$driver = 'dell_emc.powerstore.driver.PowerStoreDriver'
|
||||
}
|
||||
else {
|
||||
fail('The cinder::backend::dellemc_powerstore storage_protocol specified is not valid. It should be iSCSI or FC')
|
||||
}
|
||||
$driver = 'dell_emc.powerstore.driver.PowerStoreDriver'
|
||||
|
||||
cinder_config {
|
||||
"${name}/volume_backend_name": value => $volume_backend_name;
|
||||
|
@ -98,35 +98,30 @@ define cinder::backend::dellemc_sc (
|
||||
$san_login,
|
||||
$san_password,
|
||||
$dell_sc_ssn,
|
||||
$target_ip_address = undef,
|
||||
$volume_backend_name = $name,
|
||||
$backend_availability_zone = $facts['os_service_default'],
|
||||
$dell_sc_api_port = $facts['os_service_default'],
|
||||
$dell_sc_server_folder = 'srv',
|
||||
$dell_sc_verify_cert = $facts['os_service_default'],
|
||||
$dell_sc_volume_folder = 'vol',
|
||||
$target_port = $facts['os_service_default'],
|
||||
$excluded_domain_ips = $facts['os_service_default'],
|
||||
$secondary_san_ip = $facts['os_service_default'],
|
||||
$secondary_san_login = $facts['os_service_default'],
|
||||
$secondary_san_password = $facts['os_service_default'],
|
||||
$secondary_sc_api_port = $facts['os_service_default'],
|
||||
Boolean $manage_volume_type = false,
|
||||
$use_multipath_for_image_xfer = true,
|
||||
$sc_storage_protocol = 'iSCSI',
|
||||
Hash $extra_options = {},
|
||||
$target_ip_address = undef,
|
||||
$volume_backend_name = $name,
|
||||
$backend_availability_zone = $facts['os_service_default'],
|
||||
$dell_sc_api_port = $facts['os_service_default'],
|
||||
$dell_sc_server_folder = 'srv',
|
||||
$dell_sc_verify_cert = $facts['os_service_default'],
|
||||
$dell_sc_volume_folder = 'vol',
|
||||
$target_port = $facts['os_service_default'],
|
||||
$excluded_domain_ips = $facts['os_service_default'],
|
||||
$secondary_san_ip = $facts['os_service_default'],
|
||||
$secondary_san_login = $facts['os_service_default'],
|
||||
$secondary_san_password = $facts['os_service_default'],
|
||||
$secondary_sc_api_port = $facts['os_service_default'],
|
||||
Boolean $manage_volume_type = false,
|
||||
$use_multipath_for_image_xfer = true,
|
||||
Enum['iSCSI', 'FC'] $sc_storage_protocol = 'iSCSI',
|
||||
Hash $extra_options = {},
|
||||
) {
|
||||
|
||||
include cinder::deps
|
||||
|
||||
if $sc_storage_protocol == 'iSCSI' {
|
||||
$volume_driver = 'cinder.volume.drivers.dell_emc.sc.storagecenter_iscsi.SCISCSIDriver'
|
||||
}
|
||||
elsif $sc_storage_protocol == 'FC' {
|
||||
$volume_driver = 'cinder.volume.drivers.dell_emc.sc.storagecenter_fc.SCFCDriver'
|
||||
}
|
||||
else {
|
||||
fail('The cinder::backend::dellemc_sc sc_storage_protocol specified is not valid. It should be iSCSI or FC')
|
||||
$volume_driver = $sc_storage_protocol ? {
|
||||
'FC' => 'cinder.volume.drivers.dell_emc.sc.storagecenter_fc.SCFCDriver',
|
||||
default => 'cinder.volume.drivers.dell_emc.sc.storagecenter_iscsi.SCISCSIDriver',
|
||||
}
|
||||
|
||||
cinder_config {
|
||||
|
@ -67,27 +67,22 @@ define cinder::backend::dellemc_xtremio (
|
||||
$san_login,
|
||||
$san_password,
|
||||
$xtremio_cluster_name,
|
||||
$volume_backend_name = $name,
|
||||
$backend_availability_zone = $facts['os_service_default'],
|
||||
$xtremio_array_busy_retry_count = $facts['os_service_default'],
|
||||
$xtremio_array_busy_retry_interval = $facts['os_service_default'],
|
||||
$xtremio_volumes_per_glance_cache = $facts['os_service_default'],
|
||||
Boolean $manage_volume_type = false,
|
||||
$xtremio_storage_protocol = 'iSCSI',
|
||||
$xtremio_ports = $facts['os_service_default'],
|
||||
Hash $extra_options = {},
|
||||
$volume_backend_name = $name,
|
||||
$backend_availability_zone = $facts['os_service_default'],
|
||||
$xtremio_array_busy_retry_count = $facts['os_service_default'],
|
||||
$xtremio_array_busy_retry_interval = $facts['os_service_default'],
|
||||
$xtremio_volumes_per_glance_cache = $facts['os_service_default'],
|
||||
Boolean $manage_volume_type = false,
|
||||
Enum['iSCSI', 'FC'] $xtremio_storage_protocol = 'iSCSI',
|
||||
$xtremio_ports = $facts['os_service_default'],
|
||||
Hash $extra_options = {},
|
||||
) {
|
||||
|
||||
include cinder::deps
|
||||
|
||||
if $xtremio_storage_protocol == 'iSCSI' {
|
||||
$driver = 'dell_emc.xtremio.XtremIOISCSIDriver'
|
||||
}
|
||||
elsif $xtremio_storage_protocol == 'FC' {
|
||||
$driver = 'dell_emc.xtremio.XtremIOFCDriver'
|
||||
}
|
||||
else {
|
||||
fail('The cinder::backend::dellemc_xtremio xtremio_storage_protocol specified is not valid. It should be iSCSI or FC')
|
||||
$driver = $xtremio_storage_protocol ? {
|
||||
'FC' => 'dell_emc.xtremio.XtremIOFCDriver',
|
||||
default => 'dell_emc.xtremio.XtremIOISCSIDriver',
|
||||
}
|
||||
|
||||
cinder_config {
|
||||
|
@ -70,29 +70,24 @@ define cinder::backend::ibm_svf (
|
||||
$san_login,
|
||||
$san_password,
|
||||
$storwize_svc_volpool_name,
|
||||
$storwize_svc_allow_tenant_qos = $facts['os_service_default'],
|
||||
$storwize_svc_connection_protocol = 'iSCSI',
|
||||
$storwize_svc_iscsi_chap_enabled = $facts['os_service_default'],
|
||||
$storwize_svc_retain_aux_volume = $facts['os_service_default'],
|
||||
$storwize_portset = $facts['os_service_default'],
|
||||
$volume_backend_name = $name,
|
||||
$backend_availability_zone = $facts['os_service_default'],
|
||||
Hash $extra_options = {},
|
||||
Boolean $manage_volume_type = false,
|
||||
$storwize_svc_allow_tenant_qos = $facts['os_service_default'],
|
||||
Enum['iSCSI', 'FC'] $storwize_svc_connection_protocol = 'iSCSI',
|
||||
$storwize_svc_iscsi_chap_enabled = $facts['os_service_default'],
|
||||
$storwize_svc_retain_aux_volume = $facts['os_service_default'],
|
||||
$storwize_portset = $facts['os_service_default'],
|
||||
$volume_backend_name = $name,
|
||||
$backend_availability_zone = $facts['os_service_default'],
|
||||
Hash $extra_options = {},
|
||||
Boolean $manage_volume_type = false,
|
||||
) {
|
||||
|
||||
include cinder::deps
|
||||
|
||||
# NOTE: Svf was earlier called as storwize/svc driver, so the cinder
|
||||
# configuration parameters were named accordingly.
|
||||
if $storwize_svc_connection_protocol == 'iSCSI' {
|
||||
$volume_driver = 'cinder.volume.drivers.ibm.storwize_svc.storwize_svc_iscsi.StorwizeSVCISCSIDriver'
|
||||
}
|
||||
elsif $storwize_svc_connection_protocol == 'FC' {
|
||||
$volume_driver = 'cinder.volume.drivers.ibm.storwize_svc.storwize_svc_fc.StorwizeSVCFCDriver'
|
||||
}
|
||||
else {
|
||||
fail('The cinder::backend::ibm_svf storwize_svc_connection_protocol specified is not valid. It should be iSCSI or FC')
|
||||
$volume_driver = $storwize_svc_connection_protocol ? {
|
||||
'FC' => 'cinder.volume.drivers.ibm.storwize_svc.storwize_svc_fc.StorwizeSVCFCDriver',
|
||||
default => 'cinder.volume.drivers.ibm.storwize_svc.storwize_svc_iscsi.StorwizeSVCISCSIDriver',
|
||||
}
|
||||
|
||||
cinder_config {
|
||||
|
@ -95,34 +95,29 @@
|
||||
define cinder::backend::pure(
|
||||
$san_ip,
|
||||
$pure_api_token,
|
||||
$volume_backend_name = $name,
|
||||
$backend_availability_zone = $facts['os_service_default'],
|
||||
$pure_storage_protocol = 'iSCSI',
|
||||
$use_chap_auth = false,
|
||||
$use_multipath_for_image_xfer = true,
|
||||
Boolean $manage_volume_type = false,
|
||||
$image_volume_cache_enabled = true,
|
||||
$pure_host_personality = $facts['os_service_default'],
|
||||
$pure_eradicate_on_delete = $facts['os_service_default'],
|
||||
$pure_nvme_transport = $facts['os_service_default'],
|
||||
$pure_nvme_cidr = $facts['os_service_default'],
|
||||
$pure_nvme_cidr_list = $facts['os_service_default'],
|
||||
$pure_iscsi_cidr = $facts['os_service_default'],
|
||||
$pure_iscsi_cidr_list = $facts['os_service_default'],
|
||||
Hash $extra_options = {},
|
||||
$volume_backend_name = $name,
|
||||
$backend_availability_zone = $facts['os_service_default'],
|
||||
Enum['iSCSI', 'FC', 'NVMe'] $pure_storage_protocol = 'iSCSI',
|
||||
$use_chap_auth = false,
|
||||
$use_multipath_for_image_xfer = true,
|
||||
Boolean $manage_volume_type = false,
|
||||
$image_volume_cache_enabled = true,
|
||||
$pure_host_personality = $facts['os_service_default'],
|
||||
$pure_eradicate_on_delete = $facts['os_service_default'],
|
||||
$pure_nvme_transport = $facts['os_service_default'],
|
||||
$pure_nvme_cidr = $facts['os_service_default'],
|
||||
$pure_nvme_cidr_list = $facts['os_service_default'],
|
||||
$pure_iscsi_cidr = $facts['os_service_default'],
|
||||
$pure_iscsi_cidr_list = $facts['os_service_default'],
|
||||
Hash $extra_options = {},
|
||||
) {
|
||||
|
||||
include cinder::deps
|
||||
|
||||
$volume_driver = $pure_storage_protocol ? {
|
||||
'FC' => 'cinder.volume.drivers.pure.PureFCDriver',
|
||||
'iSCSI' => 'cinder.volume.drivers.pure.PureISCSIDriver',
|
||||
'NVMe' => 'cinder.volume.drivers.pure.PureNVMEDriver',
|
||||
default => undef,
|
||||
}
|
||||
|
||||
if ! $volume_driver {
|
||||
fail('Invalid pure_storage_protocol. It should be FC, iSCSI or NVMe')
|
||||
default => 'cinder.volume.drivers.pure.PureISCSIDriver',
|
||||
}
|
||||
|
||||
cinder_config {
|
||||
|
@ -75,9 +75,7 @@ describe 'cinder::backend::dellemc_powermax' do
|
||||
end
|
||||
|
||||
it 'should raise an error' do
|
||||
is_expected.to compile.and_raise_error(
|
||||
/The cinder::backend::dellemc_powermax powermax_storage_protocol specified is not valid. It should be iSCSI or FC/
|
||||
)
|
||||
is_expected.to compile.and_raise_error(/Evaluation Error/)
|
||||
end
|
||||
end
|
||||
|
||||
|
@ -66,9 +66,7 @@ describe 'cinder::backend::dellemc_powerstore' do
|
||||
end
|
||||
|
||||
it 'should raise an error' do
|
||||
is_expected.to compile.and_raise_error(
|
||||
/The cinder::backend::dellemc_powerstore storage_protocol specified is not valid. It should be iSCSI or FC/
|
||||
)
|
||||
is_expected.to compile.and_raise_error(/Evaluation Error/)
|
||||
end
|
||||
end
|
||||
end
|
||||
|
@ -84,9 +84,7 @@ describe 'cinder::backend::dellemc_sc' do
|
||||
end
|
||||
|
||||
it 'should raise an error' do
|
||||
is_expected.to compile.and_raise_error(
|
||||
/The cinder::backend::dellemc_sc sc_storage_protocol specified is not valid. It should be iSCSI or FC/
|
||||
)
|
||||
is_expected.to compile.and_raise_error(/Evaluation Error/)
|
||||
end
|
||||
end
|
||||
|
||||
|
@ -69,9 +69,7 @@ describe 'cinder::backend::dellemc_xtremio' do
|
||||
end
|
||||
|
||||
it 'should raise an error' do
|
||||
is_expected.to compile.and_raise_error(
|
||||
/The cinder::backend::dellemc_xtremio xtremio_storage_protocol specified is not valid. It should be iSCSI or FC/
|
||||
)
|
||||
is_expected.to compile.and_raise_error(/Evaluation Error/)
|
||||
end
|
||||
end
|
||||
|
||||
|
@ -51,9 +51,7 @@ describe 'cinder::backend::ibm_svf' do
|
||||
end
|
||||
|
||||
it 'should raise an error' do
|
||||
is_expected.to compile.and_raise_error(
|
||||
/The cinder::backend::ibm_svf storwize_svc_connection_protocol specified is not valid. It should be iSCSI or FC/
|
||||
)
|
||||
is_expected.to compile.and_raise_error(/Evaluation Error/)
|
||||
end
|
||||
end
|
||||
|
||||
|
Loading…
Reference in New Issue