puppet-cinder/manifests/backend/dellemc_powermax.pp
rajinir a8ce510145 Support for PowerMax Volume Config
PowerMax config options have changed since newton.
Updating them to the latest for both iSCSI and FC drivers.
https://docs.openstack.org/cinder/latest/configuration/block-storage/drivers/dell-emc-powermax-driver.html

Change-Id: I574968e8e479d82c0369809bf3a8c3069c40a71b
2020-03-27 18:41:35 -05:00

111 lines
3.4 KiB
Puppet

#
# == Define: cinder::backend::dellemc_powermax
#
# Setup Cinder to use the Dell EMC PowerMax Driver
# Compatible for multiple backends
#
# == Parameters
#
# [*san_ip*]
# (required) IP address of PowerMax Unisphere.
#
# [*san_login*]
# (required) PowerMax Unisphere user name.
#
# [*san_password*]
# (required) PowerMax Unisphere user password.
#
# [*powermax_array*]
# (required) Serial number of the PowerMax Array.
#
# [*powermax_srp*]
# (required) Storage resource pool on array to use for provisioning.
#
# [*powermax_port_groups*]
# (required) List of port groups.
#
# [*powermax_storage_protocol*]
# (optional) The Storage protocol, iSCSI or FC.
# This will determine
# which Volume Driver will be configured; PowerMaxISCSIDriver or PowerMaxFCDriver.
# Defaults to 'iSCSI'
# [*volume_backend_name*]
# (optional) Allows for the volume_backend_name to be separate of $name.
# Defaults to: $name
#
# [*backend_availability_zone*]
# (Optional) Availability zone for this volume backend.
# If not set, the storage_availability_zone option value
# is used as the default for all backends.
# Defaults to $::os_service_default.
#
# [*volume_driver*]
# (optional) The Dell EMC PowerMax Driver
#
# [*manage_volume_type*]
# (Optional) Whether or not manage Cinder Volume type.
# If set to true, a Cinder Volume type will be created
# with volume_backend_name=$volume_backend_name key/value.
# Defaults to false.
#
# [*extra_options*]
# (optional) Hash of extra options to pass to the backend stanza
# Defaults to: {}
# Example :
# { 'dellemc_powermax_backend/param1' => { 'value' => value1 } }#
#
define cinder::backend::dellemc_powermax (
$san_ip,
$san_login,
$san_password,
$powermax_array,
$powermax_srp,
$powermax_port_groups,
$powermax_storage_protocol = 'iSCSI',
$volume_backend_name = $name,
$backend_availability_zone = $::os_service_default,
$extra_options = {},
$manage_volume_type = false,
) {
include cinder::deps
if $powermax_storage_protocol == 'iSCSI' {
$volume_driver = 'cinder.volume.drivers.dell_emc.powermax.iscsi.PowerMaxISCSIDriver'
}
elsif $powermax_storage_protocol == 'FC' {
$volume_driver = 'cinder.volume.drivers.dell_emc.powermax.fc.PowerMaxFCDriver'
}
else {
fail('The cinder::backend::dellemc_powermax powermax_storage_protocol specified is not valid. It should be iSCSI or FC')
}
cinder_config {
"${name}/volume_backend_name": value => $volume_backend_name;
"${name}/backend_availability_zone": value => $backend_availability_zone;
"${name}/volume_driver": value => $volume_driver;
"${name}/san_ip": value => $san_ip;
"${name}/san_login": value => $san_login;
"${name}/san_password": value => $san_password, secret => true;
"${name}/powermax_array": value => $powermax_array;
"${name}/powermax_srp": value => $powermax_srp;
"${name}/powermax_port_groups": value => $powermax_port_groups;
}
if $manage_volume_type {
cinder_type { $volume_backend_name:
ensure => present,
properties => ["volume_backend_name=${volume_backend_name}"],
}
}
ensure_packages( 'pywbem', {
ensure => present,
name => $::cinder::params::pywbem_package_name,
tag => 'cinder-support-package'})
create_resources('cinder_config', $extra_options)
}