# == Class: nova::workarounds # # nova workarounds configuration # # === Parameters: # # [*never_download_image_if_on_rbd*] # (Optional) refuse to boot an instance if it would require downloading from # glance and uploading to ceph instead of a COW clone # Defaults to $facts['os_service_default'] # # [*ensure_libvirt_rbd_instance_dir_cleanup*] # (Optional) Ensure the instance directory is removed during clean up when using # rbd. When enabled this workaround will ensure that the instance directory is # always removed during cleanup on hosts using ``[libvirt]/images_type=rbd`` # Defaults to $facts['os_service_default'] # # [*enable_qemu_monitor_announce_self*] # (Optional) If it is set to True the libvirt driver will try as a best effort to # send the announce-self command to the QEMU monitor so that it generates RARP frames # to update network switches in the post live migration phase on the destination. # Defaults to $facts['os_service_default'] # # [*qemu_monitor_announce_self_count*] # (Optional) The total number of times to send the announce_self command to # the QEMU monitor when enable_qemu_monitor_announce_self is enabled. # Defaults to $facts['os_service_default'] # # [*qemu_monitor_announce_self_interval*] # (Optional) The number of seconds to wait before re-sending the announce_self # command to the QEMU monitor. # Defaults to $facts['os_service_default'] # # [*wait_for_vif_plugged_event_during_hard_reboot*] # (Optional) If set Nova will wait for the Neutron ML2 backend to sent vif # plugged events when performing hard reboot. # Defaults to $facts['os_service_default'] # # [*disable_compute_service_check_for_ffu*] # (Optional) If this is set, the normal safety check for old compute services will # be treated as a warning instead of an error. This is only to be enabled to # facilitate a Fast-Forward upgrade where new control services are being started # before compute nodes have been able to update their service record. # Defaults to $facts['os_service_default'] # # [*skip_hypervisor_version_check_on_lm*] # (Optional) When this is enabled, it will skip version-checking of # hypervisors during live migration. # Defaults to $facts['os_service_default'] # # DEPRECATED # # [*enable_numa_live_migration*] # (optional) Whether to enable live migration for NUMA topology instances. # Defaults to undef # class nova::workarounds ( $never_download_image_if_on_rbd = $facts['os_service_default'], $ensure_libvirt_rbd_instance_dir_cleanup = $facts['os_service_default'], $enable_qemu_monitor_announce_self = $facts['os_service_default'], $qemu_monitor_announce_self_count = $facts['os_service_default'], $qemu_monitor_announce_self_interval = $facts['os_service_default'], $wait_for_vif_plugged_event_during_hard_reboot = $facts['os_service_default'], $disable_compute_service_check_for_ffu = $facts['os_service_default'], $skip_hypervisor_version_check_on_lm = $facts['os_service_default'], # DEPRECATED PARAMETER $enable_numa_live_migration = undef, ) { if $enable_numa_live_migration != undef { warning('The enable_numa_live_migration parameter is deprecated') nova_config { 'workarounds/enable_numa_live_migration': value => $enable_numa_live_migration; } } nova_config { 'workarounds/never_download_image_if_on_rbd': value => $never_download_image_if_on_rbd; 'workarounds/ensure_libvirt_rbd_instance_dir_cleanup': value => $ensure_libvirt_rbd_instance_dir_cleanup; 'workarounds/enable_qemu_monitor_announce_self': value => $enable_qemu_monitor_announce_self; 'workarounds/qemu_monitor_announce_self_count': value => $qemu_monitor_announce_self_count; 'workarounds/qemu_monitor_announce_self_interval': value => $qemu_monitor_announce_self_interval; 'workarounds/wait_for_vif_plugged_event_during_hard_reboot': value => join(any2array($wait_for_vif_plugged_event_during_hard_reboot), ','); 'workarounds/disable_compute_service_check_for_ffu': value => $disable_compute_service_check_for_ffu; 'workarounds/skip_hypervisor_version_check_on_lm': value => $skip_hypervisor_version_check_on_lm; } }