python-dracclient/dracclient/resources
Monica Pardhi 9ebc4afc84 Fix for H755 RAID controller when convert to JBOD
When converting Dell EMC PERC H755 RAID controller physical
disks to non-RAID mode, RAID-0 virtual disks get created
for each physical disk and disks moved to 'Online' state.

This is different from other controllers supporting non-RAID
conversion and takes up physical disks that cannot be
later used for user intended RAID configuration. This change
excludes H755 RAID controller's physical disks when converting
to non-RAID mode and leaves disks in 'Ready' state.

Change-Id: Id6de320c8e8a9ca21fac277718c405c657f58a3a
2021-09-20 11:45:00 +00:00
..
__init__.py Add power management 2015-11-10 10:05:21 +01:00
bios.py Remove deprecated commit_required parameter from python-dracclient 2019-01-08 05:12:02 -05:00
idrac_card.py Adds ability to reset iDRAC 2018-09-27 20:03:05 -04:00
inventory.py Merge "Provide last system inventory time" 2020-09-25 15:09:04 +00:00
job.py Take Lifecycle Controller out of recovery mode 2019-06-17 04:52:24 -04:00
lifecycle_controller.py Take Lifecycle Controller out of recovery mode 2019-06-17 04:52:24 -04:00
nic.py Add support for NIC configuration 2018-07-27 15:48:07 -04:00
raid.py Fix for H755 RAID controller when convert to JBOD 2021-09-20 11:45:00 +00:00
system.py Fetch system attributes 2017-07-06 14:42:34 -07:00
uris.py Add video enumeration to InventoryManagement 2020-09-25 07:54:27 -04:00