undercloud: support noop management interface for snmp and ipmi

We're replacing the usage of the "fake" interface for snmp with
the new "noop" one. It will also be enabled for ipmi.

Change-Id: I05cca0eee30134d99a45d2dc44a8d370e7004eac
Story: #2003203
This commit is contained in:
Dmitry Tantsur 2018-08-06 14:02:24 +02:00
parent 867867d141
commit 190d0fdc74
2 changed files with 13 additions and 8 deletions

View File

@ -46,7 +46,8 @@ class TestProcessDriversAndHardwareTypes(base.TestCase):
'IronicEnabledHardwareTypes': ['idrac', 'ilo', 'ipmi', 'redfish'],
'IronicEnabledBootInterfaces': ['ilo-pxe', 'pxe'],
'IronicEnabledManagementInterfaces': ['fake', 'idrac', 'ilo',
'ipmitool', 'redfish'],
'ipmitool', 'noop',
'redfish'],
'IronicEnabledPowerInterfaces': ['fake', 'idrac', 'ilo',
'ipmitool', 'redfish'],
'IronicEnabledRaidInterfaces': ['idrac', 'no-raid'],
@ -64,7 +65,7 @@ class TestProcessDriversAndHardwareTypes(base.TestCase):
'IronicEnabledHardwareTypes': ['ipmi', 'redfish'],
'IronicEnabledBootInterfaces': ['pxe'],
'IronicEnabledManagementInterfaces': ['fake', 'ipmitool',
'redfish'],
'noop', 'redfish'],
'IronicEnabledPowerInterfaces': ['fake', 'ipmitool', 'redfish'],
'IronicEnabledRaidInterfaces': ['no-raid'],
'IronicEnabledVendorInterfaces': ['ipmitool', 'no-vendor'],
@ -91,7 +92,8 @@ class TestProcessDriversAndHardwareTypes(base.TestCase):
'IronicEnabledBootInterfaces': ['ilo-pxe', 'irmc-pxe', 'pxe'],
'IronicEnabledManagementInterfaces': ['cimc', 'fake', 'idrac',
'ilo', 'ipmitool', 'irmc',
'redfish', 'staging-ovirt',
'noop', 'redfish',
'staging-ovirt',
'ucsm', 'xclarity'],
'IronicEnabledPowerInterfaces': ['cimc', 'fake', 'idrac',
'ilo', 'ipmitool', 'irmc',

View File

@ -168,18 +168,21 @@ def _process_drivers_and_hardware_types(conf, env):
if hw_type in enabled_hardware_types:
vendor_interfaces.add(iface)
power_interfaces = mgmt_interfaces.copy()
# The snmp hardware type uses noop management and snmp power; noop
# management is also used by ipmi and staging hardware types.
mgmt_interfaces.add('noop')
if 'snmp' in enabled_hardware_types:
power_interfaces.add('snmp')
env['IronicEnabledHardwareTypes'] = sorted(enabled_hardware_types)
env['IronicEnabledBootInterfaces'] = sorted(boot_interfaces)
env['IronicEnabledManagementInterfaces'] = sorted(mgmt_interfaces)
env['IronicEnabledPowerInterfaces'] = sorted(power_interfaces)
env['IronicEnabledRaidInterfaces'] = sorted(raid_interfaces)
env['IronicEnabledVendorInterfaces'] = sorted(vendor_interfaces)
# The snmp hardware type uses fake management and snmp power
if 'snmp' in enabled_hardware_types:
mgmt_interfaces.add('snmp')
env['IronicEnabledPowerInterfaces'] = sorted(mgmt_interfaces)
def _process_ipa_args(conf, env):