When reconfiguring BIOS on iDRAC nodes, there can be a conflict between Lifecycle Controller job implementing the actual BIOS change and another job implementing boot sequence override. This change resolves the issue with the exception handler by adding code dealing with HTTP 409 error which wasn't correctly handled before, causing the problem. Change-Id: Ib57a330d267f573c8481e4823b0f5ee14556fde3
Dell EMC OEM extension for sushy
Sushy is a client library designed to communicate with Redfish based BMC.
Redfish specification offers extensibility mechanism to let hardware vendors
introduce their own features with the common Redfish framework. At the same
time, sushy
supports extending its data model by loading extensions found
within its "oem" namespace.
The sushy-oem-idrac
package is a sushy extension package that aims at
adding high-level hardware management abstractions, that are specific to
Dell EMC BMC (which is known under the name of iDRAC), to the tree of sushy
Redfish resources.
Example use
Once installed, sushy user can access Dell EMC OEM resources. For example, OEM extension of Manager resource can be instrumental for switching the node to boot from a virtual media device:
import sushy
root = sushy.Sushy('http://mydellemcbmc.example.com')
manager = root.get_manager('iDRAC.Embedded.1')
oem_manager = manager.get_oem_extension('Dell')
oem_manager.set_virtual_boot_device(
sushy.VIRTUAL_MEDIA_CD, persistent=False, manager=manager)
See full example of virtual media boot setup in the functional test suite.