Merge "Update description of CP in VNFD Template Guide"
This commit is contained in:
commit
b199df2322
@ -334,9 +334,9 @@ For asymmetric NUMA architecture:
|
||||
Connection Points
|
||||
-----------------
|
||||
Connection point is used to connect the internal virtual link or outside
|
||||
virtual link. It may be a virtual port, a virtual NIC address, a physical port
|
||||
or a physical NIC address. Each connection point has to bind to a VDU. A CP
|
||||
always requires a virtual link and a virtual binding associated with it.
|
||||
virtual link. It may be a virtual NIC or a SR-IOV NIC. Each connection
|
||||
point has to bind to a VDU. A CP always requires a virtual link and a
|
||||
virtual binding associated with it.
|
||||
|
||||
A code snippet for virtual NIC (Connection Point) without anti-spoof
|
||||
protection and are accessible by the user. CP1 and CP2 are connected to
|
||||
@ -353,9 +353,12 @@ VDU1 in this order. Also CP1/CP2 are connected to VL1/VL2 respectively.
|
||||
type: tosca.nodes.nfv.CP.Tacker
|
||||
properties:
|
||||
type: vnic
|
||||
anti_spoof_protection: false
|
||||
anti_spoofing_protection: false
|
||||
management: true
|
||||
order: 0
|
||||
security_groups:
|
||||
- secgroup1
|
||||
- secgroup2
|
||||
requirements:
|
||||
- virtualLink:
|
||||
node: VL1
|
||||
@ -365,7 +368,7 @@ VDU1 in this order. Also CP1/CP2 are connected to VL1/VL2 respectively.
|
||||
type: tosca.nodes.nfv.CP.Tacker
|
||||
properties:
|
||||
type: vnic
|
||||
anti_spoof_protection: false
|
||||
anti_spoofing_protection: false
|
||||
management: true
|
||||
order: 1
|
||||
requirements:
|
||||
@ -386,11 +389,11 @@ VDU1 in this order. Also CP1/CP2 are connected to VL1/VL2 respectively.
|
||||
+-------------------------+--------+-------+-----------+----------------------+
|
||||
| Name |Required|Type |Constraints| Description |
|
||||
+-------------------------+--------+-------+-----------+----------------------+
|
||||
| type | Yes |String | None | Could be anything |
|
||||
| | | | | like virtual port, |
|
||||
| | | | | virtual NIC address, |
|
||||
| | | | | physical port, |
|
||||
| | | | | physical NIC address |
|
||||
| type | No |String |One of | Specifies the type |
|
||||
| | | | | of CP |
|
||||
| | | |- vnic | |
|
||||
| | | | (default)| |
|
||||
| | | |- sriov | |
|
||||
+-------------------------+--------+-------+-----------+----------------------+
|
||||
| anti_spoofing_protection| No |Boolean| None | Indicates whether |
|
||||
| | | | | anti_spoof rule is |
|
||||
@ -411,6 +414,11 @@ VDU1 in this order. Also CP1/CP2 are connected to VL1/VL2 respectively.
|
||||
| | | | | and ordering is |
|
||||
| | | | | required. |
|
||||
+-------------------------+--------+-------+-----------+----------------------+
|
||||
| security_groups | No |List | None | List of security |
|
||||
| | | | | groups to be |
|
||||
| | | | | associated with |
|
||||
| | | | | the CP |
|
||||
+-------------------------+--------+-------+-----------+----------------------+
|
||||
|
||||
:requirements:
|
||||
|
||||
@ -550,6 +558,7 @@ a template which mentions all node types with all available options.
|
||||
anti_spoofing_protection: [true, false]
|
||||
type: [ sriov, vnic ]
|
||||
order: order of CP within a VDU
|
||||
security_groups: list of security groups
|
||||
requirements:
|
||||
- virtualLink:
|
||||
node: VL to link to
|
||||
|
Loading…