Tacker Monitoring Framework
============================
This section will introduce tacker monitoring framework and describes the
various actions that a user can take when a specific event occurs.
* Introduction
* How to write a new monitor driver
* Events
* Actions
* How to write TOSCA template to monitor VNF entities
Introduction
-------------
Tacker monitoring framework provides the NFV operators and VNF vendors to
write a pluggable driver that monitors the various status conditions of the
VNF entities it deploys and manages.
How to write a new monitor driver
----------------------------------
A monitor driver for tacker is a python module which contains a class that
inherits from
"tacker.vnfm.monitor_drivers.abstract_driver.VNFMonitorAbstractDriver". If the
driver depends/imports more than one module, then create a new python package
under tacker/vnfm/monitor_drivers folder. After this we have to mention our
driver path in setup.cfg file in root directory.
For example:
::
tacker.tacker.monitor_drivers =
ping = tacker.vnfm.monitor_drivers.ping.ping:VNFMonitorPing
Following methods need to be overridden in the new driver:
``def get_type(self)``
This method must return the type of driver. ex: ping
``def get_name(self)``
This method must return the symbolic name of the vnf monitor plugin.
``def get_description(self)``
This method must return the description for the monitor driver.
``def monitor_get_config(self, plugin, context, vnf)``
This method must return dictionary of configuration data for the monitor
driver.
``def monitor_url(self, plugin, context, vnf)``
This method must return the url of vnf to monitor.
``def monitor_call(self, vnf, kwargs)``
This method must either return boolean value 'True', if VNF is healthy.
Otherwise it should return an event string like 'failure' or
'calls-capacity-reached' based on specific VNF health condition. More
details on these event is given in below section.
Custom events
--------------
As mentioned in above section, if the return value of monitor_call method is
other than boolean value 'True', then we have to map those event to the
corresponding action as described below.
For example:
::
vdu1:
monitoring_policy:
ping:
actions:
failure: respawn
In this example, we have an event called 'failure'. So whenever monitor_call
returns 'failure' tacker will respawn the VNF.
Actions
--------
The available actions that a monitor driver can call when a particular event
occurs.
#. respawn
#. log
How to write TOSCA template to monitor VNF entities
----------------------------------------------------
In the vdus section, under vdu you can specify the monitors details with
corresponding actions and parameters.The syntax for writing monitor policy
is as follows:
::
vduN:
monitoring_policy:
<monitoring-driver-name>:
monitoring_params:
<param-name>: <param-value>
...
actions:
<event>: <action-name>
...
...
Example Template
----------------
::
vdu1:
monitoring_policy:
ping:
actions:
failure: respawn
vdu2:
monitoring_policy:
http-ping:
monitoring_params:
port: 8080
url: ping.cgi
actions:
failure: respawn
acme_scaling_driver:
monitoring_params:
resource: cpu
threshold: 10000
actions:
max_foo_reached: scale_up
min_foo_reached: scale_down