Support for SC Cinder Backend
Updating the SC cinder backend to support both iSCSI and FC drivers. It is also enhanceded to support multiple backends. CinderScBackendName supports a list of backend names and a new CindeScMultiConfig parameter provides a way to specify parameter values for each backend. For example see file environments/cinder-dellemc-sc-config.yaml Depends-On: https://review.opendev.org/#/c/722538/ Change-Id: I6e5f3753fe167c7fbc75c3d382c88c09c247c7b3
This commit is contained in:
parent
5e62d5da1d
commit
ddd2385e00
149
deployment/cinder/cinder-backend-dellemc-sc-puppet.yaml
Normal file
149
deployment/cinder/cinder-backend-dellemc-sc-puppet.yaml
Normal file
@ -0,0 +1,149 @@
|
||||
# Copyright (c) 2016-2020 Dell Inc, or its subsidiaries.
|
||||
#
|
||||
# Licensed under the Apache License, Version 2.0 (the "License");
|
||||
# you may not use this file except in compliance with the License.
|
||||
# You may obtain a copy of the License at
|
||||
#
|
||||
# http://www.apache.org/licenses/LICENSE-2.0
|
||||
#
|
||||
# Unless required by applicable law or agreed to in writing, software
|
||||
# distributed under the License is distributed on an "AS IS" BASIS,
|
||||
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
||||
# See the License for the specific language governing permissions and
|
||||
# limitations under the License.
|
||||
heat_template_version: rocky
|
||||
|
||||
description: >
|
||||
Openstack Cinder Dell EMC Storage Center backend
|
||||
|
||||
parameters:
|
||||
CinderEnableScBackend:
|
||||
type: boolean
|
||||
default: true
|
||||
CinderScBackendName:
|
||||
type: comma_delimited_list
|
||||
default: 'tripleo_dellemc_sc'
|
||||
description: A list of Cinder SC Storage backend names.
|
||||
CinderScMultiConfig:
|
||||
type: json
|
||||
default: {}
|
||||
description: >
|
||||
Dictionary of settings when configuring multiple SC backends. The
|
||||
hash key is the backend name, and the value is a dictionary of parameter
|
||||
values unique to that backend.
|
||||
CinderScAvailabilityZone:
|
||||
default: ''
|
||||
description: >
|
||||
The availability zone of the Dell SC Cinder backend.
|
||||
When set, it overrides the default CinderStorageAvailabilityZone.
|
||||
type: string
|
||||
CinderScSanIp:
|
||||
type: string
|
||||
CinderScSanLogin:
|
||||
type: string
|
||||
default: 'Admin'
|
||||
CinderScSanPassword:
|
||||
type: string
|
||||
hidden: true
|
||||
CinderScSsn:
|
||||
type: number
|
||||
default: 64702
|
||||
CinderScIscsiIpAddress:
|
||||
type: string
|
||||
default: ''
|
||||
CinderScIscsiPort:
|
||||
type: number
|
||||
default: 3260
|
||||
CinderScApiPort:
|
||||
type: number
|
||||
default: 3033
|
||||
CinderScServerFolder:
|
||||
type: string
|
||||
default: 'dellsc_server'
|
||||
CinderScVolumeFolder:
|
||||
type: string
|
||||
default: 'dellsc_volume'
|
||||
CinderScSecondarySanIp:
|
||||
type: string
|
||||
default: ''
|
||||
CinderScSecondarySanLogin:
|
||||
type: string
|
||||
default: 'Admin'
|
||||
CinderScSecondarySanPassword:
|
||||
type: string
|
||||
hidden: true
|
||||
CinderScSecondaryScApiPort:
|
||||
type: number
|
||||
default: 3033
|
||||
CinderScExcludedDomainIp:
|
||||
type: string
|
||||
default: ''
|
||||
CinderScExcludedDomainIps:
|
||||
type: comma_delimited_list
|
||||
default: []
|
||||
CinderScMultipathXfer:
|
||||
type: boolean
|
||||
default: true
|
||||
CinderSCStorageProtocol:
|
||||
type: string
|
||||
default: 'iSCSI'
|
||||
constraints:
|
||||
- allowed_values: [ 'iSCSI', 'FC']
|
||||
ServiceData:
|
||||
default: {}
|
||||
description: Dictionary packing service data
|
||||
type: json
|
||||
ServiceNetMap:
|
||||
default: {}
|
||||
description: Mapping of service_name -> network name. Typically set
|
||||
via parameter_defaults in the resource registry. This
|
||||
mapping overrides those in ServiceNetMapDefaults.
|
||||
type: json
|
||||
DefaultPasswords:
|
||||
default: {}
|
||||
type: json
|
||||
RoleName:
|
||||
default: ''
|
||||
description: Role name on which the service is applied
|
||||
type: string
|
||||
RoleParameters:
|
||||
default: {}
|
||||
description: Parameters specific to the role
|
||||
type: json
|
||||
EndpointMap:
|
||||
default: {}
|
||||
type: json
|
||||
description: Mapping of service endpoint -> protocol. Typically set
|
||||
via parameter_defaults in the resource registry.
|
||||
|
||||
outputs:
|
||||
role_data:
|
||||
description: Role data for the Cinder Dell EMC Storage Center backend.
|
||||
value:
|
||||
service_name: cinder_backend_dellsc
|
||||
config_settings:
|
||||
map_merge:
|
||||
- tripleo::profile::base::cinder::volume::cinder_enable_dellsc_backend: {get_param: CinderEnableScBackend}
|
||||
cinder::backend::dellemc_sc::volume_backend_name: {get_param: CinderScBackendName}
|
||||
cinder::backend::dellemc_sc::volume_multi_config: {get_param: CinderScMultiConfig}
|
||||
cinder::backend::dellemc_sc::san_ip: {get_param: CinderScSanIp}
|
||||
cinder::backend::dellemc_sc::san_login: {get_param: CinderScSanLogin}
|
||||
cinder::backend::dellemc_sc::san_password: {get_param: CinderScSanPassword}
|
||||
cinder::backend::dellemc_sc::dell_sc_ssn: {get_param: CinderScSsn}
|
||||
cinder::backend::dellemc_sc::iscsi_ip_address: {get_param: CinderScIscsiIpAddress}
|
||||
cinder::backend::dellemc_sc::iscsi_port: {get_param: CinderScIscsiPort}
|
||||
cinder::backend::dellemc_sc::dell_sc_api_port: {get_param: CinderScApiPort}
|
||||
cinder::backend::dellemc_sc::dell_sc_server_folder: {get_param: CinderScServerFolder}
|
||||
cinder::backend::dellemc_sc::dell_sc_volume_folder: {get_param: CinderScVolumeFolder}
|
||||
cinder::backend::dellemc_sc::secondary_san_ip: {get_param: CinderScSecondarySanIp}
|
||||
cinder::backend::dellemc_sc::secondary_san_login: {get_param: CinderScSecondarySanLogin}
|
||||
cinder::backend::dellemc_sc::secondary_san_password: {get_param: CinderScSecondarySanPassword}
|
||||
cinder::backend::dellemc_sc::secondary_sc_api_port: {get_param: CinderScSecondaryScApiPort}
|
||||
cinder::backend::dellemc_sc::excluded_domain_ips: {get_param: CinderScExcludedDomainIps}
|
||||
cinder::backend::dellemc_sc::use_multipath_for_image_xfer: {get_param: CinderScMultipathXfer}
|
||||
cinder::backend::dellemc_sc::sc_storage_protocol: {get_param: CinderScStorageProtocol}
|
||||
-
|
||||
if:
|
||||
- {equals : [{get_param: CinderScAvailabilityZone}, '']}
|
||||
- {}
|
||||
- cinder::backend::dellemc_sc::backend_availability_zone: {get_param: CinderScAvailabilityZone}
|
39
environments/cinder-dellemc-sc-config.yaml
Normal file
39
environments/cinder-dellemc-sc-config.yaml
Normal file
@ -0,0 +1,39 @@
|
||||
# A Heat environment file which can be used to enable a
|
||||
# Cinder Dell EMC Storage Center backend, configured via puppet
|
||||
resource_registry:
|
||||
OS::TripleO::Services::CinderBackendDellEMCSc: ../deployment/cinder/cinder-backend-dellemc-sc-puppet.yaml
|
||||
|
||||
parameter_defaults:
|
||||
CinderEnableScBackend: true
|
||||
CinderScBackendName: 'tripleo_dellemc_sc'
|
||||
CinderScMultiConfig: {}
|
||||
CinderScSanIp: ''
|
||||
CinderScSanLogin: 'Admin'
|
||||
CinderScSanPassword: ''
|
||||
CinderScSsn: 64702
|
||||
CinderScIscsiIpAddress: ''
|
||||
CinderScIscsiPort: 3260
|
||||
CinderScApiPort: 3033
|
||||
CinderScServerFolder: 'dellsc_server'
|
||||
CinderScVolumeFolder: 'dellsc_volume'
|
||||
CinderScSecondarySanIp: ''
|
||||
CinderScSecondarySanLogin: 'Admin'
|
||||
CinderScSecondarySanPassword: ''
|
||||
CinderScSecondaryScApiPort: 3033
|
||||
CinderScExcludedDomainIps: []
|
||||
CinderScMultipathXfer: true
|
||||
CinderScStorageProtocol: 'iSCSI'
|
||||
# To configure multiple SC backends, use CinderScMultiConfig to
|
||||
# assign parameter values specific to that backend. CinderScMultiConfig
|
||||
# is a dictionary of the parameter values for each backend specified in
|
||||
# CinderScBackendName
|
||||
# For example, see below:
|
||||
# CinderScBackendName:
|
||||
# - tripleo_dellemc_sc_1
|
||||
# - tripleo_dellemc_sc_2
|
||||
# CinderScMultiConfig:
|
||||
# tripleo_dellemc_sc_1:
|
||||
# CinderScStorageProtocol: 'iSCSI' # Specific value for this backend
|
||||
# tripleo_dellemc_sc_2:
|
||||
# CinderScStorageProtocol: 'FC' # Specific value for this backend
|
||||
|
@ -273,6 +273,7 @@ resource_registry:
|
||||
OS::TripleO::Services::NeutronML2FujitsuCfab: OS::Heat::None
|
||||
OS::TripleO::Services::NeutronML2FujitsuFossw: OS::Heat::None
|
||||
OS::TripleO::Services::CinderBackendDellSc: OS::Heat::None
|
||||
OS::TripleO::Services::CinderBackendDellEMCSc: OS::Heat::None
|
||||
OS::TripleO::Services::CinderBackendDellEMCPowermax: OS::Heat::None
|
||||
OS::TripleO::Services::CinderBackendDellEMCUnity: OS::Heat::None
|
||||
OS::TripleO::Services::CinderBackendDellEMCVMAXISCSI: OS::Heat::None
|
||||
|
6
releasenotes/notes/sc-driver-a428e372280c44e6.yaml
Normal file
6
releasenotes/notes/sc-driver-a428e372280c44e6.yaml
Normal file
@ -0,0 +1,6 @@
|
||||
---
|
||||
features:
|
||||
- Support for Dell EMC SC backend cinder driver.
|
||||
Supports both iSCSI and FC volume drivers
|
||||
and support deploying one or multiple cinder
|
||||
SC storage backends.
|
@ -59,6 +59,7 @@
|
||||
- OS::TripleO::Services::CinderApi
|
||||
- OS::TripleO::Services::CinderBackendDellSc
|
||||
- OS::TripleO::Services::CinderBackendDellEMCPowermax
|
||||
- OS::TripleO::Services::CinderBackendDellEMCSc
|
||||
- OS::TripleO::Services::CinderBackendDellEMCUnity
|
||||
- OS::TripleO::Services::CinderBackendDellEMCVMAXISCSI
|
||||
- OS::TripleO::Services::CinderBackendDellEMCVNX
|
||||
|
@ -51,6 +51,7 @@
|
||||
- OS::TripleO::Services::CinderApi
|
||||
- OS::TripleO::Services::CinderBackendDellSc
|
||||
- OS::TripleO::Services::CinderBackendDellEMCPowermax
|
||||
- OS::TripleO::Services::CinderBackendDellEMCSc
|
||||
- OS::TripleO::Services::CinderBackendDellEMCUnity
|
||||
- OS::TripleO::Services::CinderBackendDellEMCVMAXISCSI
|
||||
- OS::TripleO::Services::CinderBackendDellEMCVNX
|
||||
|
@ -44,6 +44,7 @@
|
||||
- OS::TripleO::Services::CinderApi
|
||||
- OS::TripleO::Services::CinderBackendDellSc
|
||||
- OS::TripleO::Services::CinderBackendDellEMCPowermax
|
||||
- OS::TripleO::Services::CinderBackendDellEMCSc
|
||||
- OS::TripleO::Services::CinderBackendDellEMCUnity
|
||||
- OS::TripleO::Services::CinderBackendDellEMCVMAXISCSI
|
||||
- OS::TripleO::Services::CinderBackendDellEMCVNX
|
||||
|
@ -60,6 +60,7 @@
|
||||
- OS::TripleO::Services::CinderApi
|
||||
- OS::TripleO::Services::CinderBackendDellSc
|
||||
- OS::TripleO::Services::CinderBackendDellEMCPowermax
|
||||
- OS::TripleO::Services::CinderBackendDellEMCSc
|
||||
- OS::TripleO::Services::CinderBackendDellEMCUnity
|
||||
- OS::TripleO::Services::CinderBackendDellEMCVMAXISCSI
|
||||
- OS::TripleO::Services::CinderBackendDellEMCVNX
|
||||
|
@ -61,6 +61,7 @@
|
||||
- OS::TripleO::Services::CinderApi
|
||||
- OS::TripleO::Services::CinderBackendDellSc
|
||||
- OS::TripleO::Services::CinderBackendDellEMCPowermax
|
||||
- OS::TripleO::Services::CinderBackendDellEMCSc
|
||||
- OS::TripleO::Services::CinderBackendDellEMCUnity
|
||||
- OS::TripleO::Services::CinderBackendDellEMCVMAXISCSI
|
||||
- OS::TripleO::Services::CinderBackendDellEMCVNX
|
||||
|
@ -50,6 +50,7 @@
|
||||
- OS::TripleO::Services::CertmongerUser
|
||||
- OS::TripleO::Services::CinderApi
|
||||
- OS::TripleO::Services::CinderBackendDellEMCPowermax
|
||||
- OS::TripleO::Services::CinderBackendDellEMCSc
|
||||
- OS::TripleO::Services::CinderBackendDellEMCUnity
|
||||
- OS::TripleO::Services::CinderBackendDellEMCVMAXISCSI
|
||||
- OS::TripleO::Services::CinderBackendDellEMCVNX
|
||||
|
@ -62,6 +62,7 @@
|
||||
- OS::TripleO::Services::CinderApi
|
||||
- OS::TripleO::Services::CinderBackendDellSc
|
||||
- OS::TripleO::Services::CinderBackendDellEMCPowermax
|
||||
- OS::TripleO::Services::CinderBackendDellEMCSc
|
||||
- OS::TripleO::Services::CinderBackendDellEMCUnity
|
||||
- OS::TripleO::Services::CinderBackendDellEMCVMAXISCSI
|
||||
- OS::TripleO::Services::CinderBackendDellEMCVNX
|
||||
|
Loading…
x
Reference in New Issue
Block a user