Remove Combination alarms support

combination alarms are completely removed in Ocata.
Remove this from tripleo.

Change-Id: Iec2e26ebdaa108ddbb2cf45fc4b6c68023fb6ce0
This commit is contained in:
Pradeep Kilambi 2016-11-16 16:09:48 -05:00
parent e171ef1b68
commit ea22134c72
1 changed files with 0 additions and 6 deletions

View File

@ -21,11 +21,6 @@ parameters:
MonitoringSubscriptionAodhApi:
default: 'overcloud-ceilometer-aodh-api'
type: string
EnableCombinationAlarms:
default: false
description: Combination alarms are deprecated in Newton, hence disabled
by default. To enable, set this parameter to true.
type: boolean
EnableInternalTLS:
type: boolean
default: false
@ -83,7 +78,6 @@ outputs:
# internal_api_uri -> [IP]
# internal_api_subnet - > IP/CIDR
aodh::wsgi::apache::bind_host: {get_param: [ServiceNetMap, AodhApiNetwork]}
tripleo::profile::base::aodh::api::enable_combination_alarms: {get_param: EnableCombinationAlarms}
service_config_settings:
get_attr: [AodhBase, role_data, service_config_settings]
step_config: |