tripleo-heat-templates/deployment/cinder/cinder-backend-dellsc-puppet.yaml
rajinir 21773792c5 Deprecating Old Dell SC Iscsi Volume Config
New Dell EMC SC Volume config that now supports both iSCSI and FC
drivers is added. See https://review.opendev.org/#/c/723018/
Deprecating the old resource.

Change-Id: I323dbc95eea8086faeb815f069202ca25720fdaa
2020-04-24 16:26:13 -05:00

160 lines
5.7 KiB
YAML

# Copyright (c) 2016-2017 Dell Inc, or its subsidiaries.
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
heat_template_version: rocky
description: >
Openstack Cinder Dell EMC Storage Center backend
Please note, this template is deprecated now.
Use Cinder Dell EMC SC backend template defined in
cinder-backend-dellemc-sc-puppet.yaml.
parameters:
CinderEnableDellScBackend:
type: boolean
default: true
CinderDellScBackendName:
type: string
default: 'tripleo_dellsc'
CinderDellScAvailabilityZone:
default: ''
description: >
The availability zone of the Dell SC Cinder backend.
When set, it overrides the default CinderStorageAvailabilityZone.
type: string
CinderDellScSanIp:
type: string
CinderDellScSanLogin:
type: string
default: 'Admin'
CinderDellScSanPassword:
type: string
hidden: true
CinderDellScSsn:
type: number
default: 64702
CinderDellScIscsiIpAddress:
type: string
default: ''
CinderDellScIscsiPort:
type: number
default: 3260
CinderDellScApiPort:
type: number
default: 3033
CinderDellScServerFolder:
type: string
default: 'dellsc_server'
CinderDellScVolumeFolder:
type: string
default: 'dellsc_volume'
CinderDellScSecondarySanIp:
type: string
default: ''
CinderDellScSecondarySanLogin:
type: string
default: 'Admin'
CinderDellScSecondarySanPassword:
type: string
hidden: true
CinderDellScSecondaryScApiPort:
type: number
default: 3033
CinderDellScExcludedDomainIp:
type: string
default: ''
CinderDellScExcludedDomainIps:
type: comma_delimited_list
default: []
CinderDellScMultipathXfer:
type: boolean
default: true
ServiceData:
default: {}
description: Dictionary packing service data
type: json
ServiceNetMap:
default: {}
description: Mapping of service_name -> network name. Typically set
via parameter_defaults in the resource registry. This
mapping overrides those in ServiceNetMapDefaults.
type: json
DefaultPasswords:
default: {}
type: json
RoleName:
default: ''
description: Role name on which the service is applied
type: string
RoleParameters:
default: {}
description: Parameters specific to the role
type: json
EndpointMap:
default: {}
type: json
description: Mapping of service endpoint -> protocol. Typically set
via parameter_defaults in the resource registry.
parameter_groups:
- label: deprecated
description: |
The following parameters are deprecated and will be removed.
parameters:
- CinderEnableDellScBackend
- CinderDellScBackendName
- CinderDellScSanIp
- CinderDellScSanLogin
- CinderDellScSanPassword
- CinderDellScSsn
- CinderDellScIscsiIpAddress
- CinderDellScIscsiPort
- CinderDellScApiPort
- CinderDellScServerFolder
- CinderDellScVolumeFolder
- CinderDellScSecondarySanIp
- CinderDellScSecondarySanLogin
- CinderDellScSecondarySanPassword
- CinderDellScSecondaryScApiPort
- CinderDellScExcludedDomainIps
- CinderDellScMultipathXfer
outputs:
role_data:
description: Role data for the Cinder Dell EMC Storage Center backend.
value:
service_name: cinder_backend_dellsc
config_settings:
map_merge:
- tripleo::profile::base::cinder::volume::cinder_enable_dellsc_backend: {get_param: CinderEnableDellScBackend}
cinder::backend::dellsc_iscsi::volume_backend_name: {get_param: CinderDellScBackendName}
cinder::backend::dellsc_iscsi::san_ip: {get_param: CinderDellScSanIp}
cinder::backend::dellsc_iscsi::san_login: {get_param: CinderDellScSanLogin}
cinder::backend::dellsc_iscsi::san_password: {get_param: CinderDellScSanPassword}
cinder::backend::dellsc_iscsi::dell_sc_ssn: {get_param: CinderDellScSsn}
cinder::backend::dellsc_iscsi::iscsi_ip_address: {get_param: CinderDellScIscsiIpAddress}
cinder::backend::dellsc_iscsi::iscsi_port: {get_param: CinderDellScIscsiPort}
cinder::backend::dellsc_iscsi::dell_sc_api_port: {get_param: CinderDellScApiPort}
cinder::backend::dellsc_iscsi::dell_sc_server_folder: {get_param: CinderDellScServerFolder}
cinder::backend::dellsc_iscsi::dell_sc_volume_folder: {get_param: CinderDellScVolumeFolder}
cinder::backend::dellsc_iscsi::secondary_san_ip: {get_param: CinderDellScSecondarySanIp}
cinder::backend::dellsc_iscsi::secondary_san_login: {get_param: CinderDellScSecondarySanLogin}
cinder::backend::dellsc_iscsi::secondary_san_password: {get_param: CinderDellScSecondarySanPassword}
cinder::backend::dellsc_iscsi::secondary_sc_api_port: {get_param: CinderDellScSecondaryScApiPort}
cinder::backend::dellsc_iscsi::excluded_domain_ips: {get_param: CinderDellScExcludedDomainIps}
cinder::backend::dellsc_iscsi::use_multipath_for_image_xfer: {get_param: CinderDellScMultipathXfer}
-
if:
- {equals : [{get_param: CinderDellScAvailabilityZone}, '']}
- {}
- cinder::backend::dellsc_iscsi::backend_availability_zone: {get_param: CinderDellScAvailabilityZone}