tripleo-heat-templates/puppet/services/cinder-backend-dellemc-vmax-iscsi.yaml
rajinir 2677de31fc Add support for Dell EMC VMAX ISCSI Backend
This change adds a new define for cinder::backend::dellemc_vmax_iscsi

Change-Id: I7c685e0a3186da138964f17b487fb0c3533f58c7
Implements: blueprint dellemc-vmax-isci
(cherry picked from commit c771899055)
Depends-On: Ifc169c60994856e382b76b72e020624ca64eef9f
2017-11-13 08:45:55 -06:00

66 lines
2.3 KiB
YAML

# Copyright (c) 2016-2017 Dell Inc, or its subsidiaries.
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
heat_template_version: ocata
description: >
Openstack Cinder Dell EMC VMAX iscsi backend
parameters:
CinderEnableDellEMCVMAXISCSIBackend:
type: boolean
default: true
CinderDellEMCVMAXISCSIBackendName:
type: string
default: 'tripleo_dellemc_vmax_iscsi'
CinderDellEMCVMAXISCSIConfigFile:
type: string
ServiceData:
default: {}
description: Dictionary packing service data
type: json
ServiceNetMap:
default: {}
description: Mapping of service_name -> network name. Typically set
via parameter_defaults in the resource registry. This
mapping overrides those in ServiceNetMapDefaults.
type: json
DefaultPasswords:
default: {}
type: json
RoleName:
default: ''
description: Role name on which the service is applied
type: string
RoleParameters:
default: {}
description: Parameters specific to the role
type: json
EndpointMap:
default: {}
type: json
description: Mapping of service endpoint -> protocol. Typically set
via parameter_defaults in the resource registry.
outputs:
role_data:
description: Role data for the Cinder Dell EMC VMAX iscsi backend.
value:
service_name: cinder_backend_dellemc_vmax_iscsi
config_settings:
tripleo::profile::base::cinder::volume::cinder_enable_dellemc_vmax_iscsi_backend: {get_param: CinderEnableDellEMCVMAXISCSIBackend}
cinder::backend::dell_emc_vmax_iscsi::volume_backend_name: {get_param: CinderDellEMCVMAXISCSIBackendName}
cinder::backend::dell_emc_vmax_iscsi::cinder_emc_config_file: {get_param: CinderDellEMCVMAXISCSIConfigFile}
step_config: |
include ::tripleo::profile::base::cinder::volume