============================ Alarm Severity Configuration ============================ Overview -------- Vitrage retrieves information from diverse data-sources regarding alarms in the cloud, and stores and combines this information into a unified system model. An important property of an alarm is its **severity**. This severity can be used both in the Vitrage templates to trigger actions, and in the Horizon UI for color-coding purposes. Therefore, it is important that within the Vitrage data model, severity names are aggregated and normalized. Since each data-source might represent severity differently, for each data-source we can supply it's own mapping to the aggregated severity supported in Vitrage. This way we can know which severity is more important. In addition we also normalize the severities for the horizon UI (called ``vitrage_operational_severity``) in order for the UI to know what color to show in Horizon. This page explains how to handle this mapping for a given data-source. Configure Access to Alarm Severity ---------------------------------- The alarm severity configuration is handled via config files. The location of these files can be determined in **/etc/vitrage/vitrage.conf**. Under the [entity_graph] section, set: +------------------------+------------------------------------+----------------------------------+ | Name | Description | Default Value | +========================+====================================+==================================+ | datasources_values_dir | Directory path from where to load | /etc/vitrage/datasources_values/ | | | the values configurations | | +------------------------+------------------------------------+----------------------------------+ Configure Alarm Severity Mapping -------------------------------- The alarm severity configuration files configure how the severity of each alarm is aggregated and normalized. There are several guidelines for creating a config file: - Operational severity is a normalized severity values can be mapped to specific defined values which can be found in operational_alarm_severity.py (OperationalAlarmSeverity class). - Aggregated severity comes with a priority, so that if an alarm is given different severities from different sources (e.g., a host alarm raised both by nagios and Vitrage), the severity with the highest priority will be used as the **aggregated severity**. - The config file is in YAML format. - The config filename must be .yaml, for the relevant datasource. - Defining a config file for each datasource is recommended, but not mandatory. Datasources with no such configuration will use the values as-is. Once the file is modified, you must restart **vitrage-graph** service to load the changes. Default Configuration +++++++++++++++++++++ Default configurations for alarms severities will be installed with Vitrage for all the pre-packaged data-sources. Format ++++++ .. code:: yaml category: ALARM values: - aggregated values: priority: original values: - name: operational_value: - name: ... # can list several severities for one aggregation - aggregated values: priority: ... # can list several aggregated severities ... ... Example +++++++ The following file will map alarm severities. For aggregated severity with priority 40 we have 2 severities and each one of them is mapped to operational severity CRITICAL. For aggregated severity with priority 30 we have 1 severity called WARNING and it is mapped to operational severity WARNING, etc... .. code:: yaml category: ALARM values: - aggregated values: priority: 40 original values: - name: CRITICAL operational_value: CRITICAL - name: DOWN operational_value: CRITICAL - aggregated values: priority: 30 original values: - name: WARNING operational_value: WARNING - aggregated values: priority: 20 original values: - name: UNKNOWN operational_value: N/A - aggregated values: priority: 10 original values: - name: OK operational_value: OK - name: UP operational_value: OK