# Copyright (c) 2013-2014 Wind River Systems, Inc.
|
|
#
|
|
# SPDX-License-Identifier: Apache-2.0
|
|
#
|
|
|
|
# vim: tabstop=4 shiftwidth=4 softtabstop=4
|
|
|
|
# All Rights Reserved.
|
|
#
|
|
|
|
""" inventory ipv Utilities and helper functions."""
|
|
|
|
import json
|
|
import subprocess
|
|
import sys
|
|
from sysinv.common import constants
|
|
from sysinv.common import exception
|
|
from sysinv.common import utils as cutils
|
|
from sysinv.openstack.common import log as logging
|
|
|
|
LOG = logging.getLogger(__name__)
|
|
|
|
|
|
class PVOperator(object):
|
|
'''Class to encapsulate Physical Volume operations for System Inventory'''
|
|
|
|
def __init__(self):
|
|
pass
|
|
|
|
def handle_exception(self, e):
|
|
traceback = sys.exc_info()[-1]
|
|
LOG.error("%s @ %s:%s" % (e, traceback.tb_frame.f_code.co_filename,
|
|
traceback.tb_lineno))
|
|
|
|
def ipv_get(self, cinder_device=None):
|
|
'''Enumerate physical volume topology based on:
|
|
|
|
:param self
|
|
:param cinder_device: by-path of cinder device
|
|
:returns list of physical volumes and attributes
|
|
'''
|
|
ipv = []
|
|
|
|
# keys: matching the field order of pvdisplay command
|
|
string_keys = ['lvm_pv_name', 'lvm_vg_name', 'lvm_pv_uuid',
|
|
'lvm_pv_size', 'lvm_pe_total', 'lvm_pe_alloced']
|
|
|
|
# keys that need to be translated into ints
|
|
int_keys = ['lvm_pv_size', 'lvm_pe_total', 'lvm_pe_alloced']
|
|
|
|
# pvdisplay command to retrieve the pv data of all pvs present
|
|
pvdisplay_command = 'pvdisplay -C --separator=";" -o pv_name,vg_name,pv_uuid'\
|
|
',pv_size,pv_pe_count,pv_pe_alloc_count'\
|
|
' --units B --nosuffix --noheadings'
|
|
|
|
# Execute the command
|
|
try:
|
|
pvdisplay_process = subprocess.Popen(pvdisplay_command,
|
|
stdout=subprocess.PIPE,
|
|
shell=True)
|
|
pvdisplay_output = pvdisplay_process.stdout.read()
|
|
except Exception as e:
|
|
self.handle_exception("Could not retrieve pvdisplay "
|
|
"information: %s" % e)
|
|
pvdisplay_output = ""
|
|
|
|
# Cinder devices are hidden by global_filter on standby controller,
|
|
# list them separately.
|
|
if cinder_device:
|
|
new_global_filer = ' --config \'devices/global_filter=["a|' + \
|
|
cinder_device + '|","r|.*|"]\''
|
|
pvdisplay_process = pvdisplay_command + new_global_filer
|
|
|
|
try:
|
|
pvdisplay_process = subprocess.Popen(pvdisplay_process,
|
|
stdout=subprocess.PIPE,
|
|
shell=True)
|
|
pvdisplay_output = pvdisplay_output + pvdisplay_process.stdout.read()
|
|
except Exception as e:
|
|
self.handle_exception("Could not retrieve vgdisplay "
|
|
"information: %s" % e)
|
|
|
|
# parse the output 1 pv/row
|
|
rows = [row for row in pvdisplay_output.split('\n') if row.strip()]
|
|
for row in rows:
|
|
if "unknown device" in row:
|
|
# Found a previously known pv that is now missing
|
|
# This happens when a disk is physically removed without
|
|
# being removed from the volume group first
|
|
# Since the disk is gone we need to forcefully cleanup
|
|
# the volume group
|
|
try:
|
|
values = row.split(';')
|
|
values = [v.strip() for v in values]
|
|
|
|
vgreduce_command = 'vgreduce --removemissing %s' % values[2]
|
|
subprocess.Popen(vgreduce_command,
|
|
stdout=subprocess.PIPE,
|
|
shell=True)
|
|
except Exception as e:
|
|
self.handle_exception("Could not execute vgreduce: %s" % e)
|
|
continue
|
|
|
|
# get the values of fields as strings
|
|
values = row.split(';')
|
|
values = [v.strip() for v in values]
|
|
|
|
# create the dict of attributes
|
|
attr = dict(zip(string_keys, values))
|
|
|
|
# convert required values from strings to ints
|
|
for k in int_keys:
|
|
if k in attr.keys():
|
|
attr[k] = int(attr[k])
|
|
|
|
# Make sure we have attributes and ignore orphaned PVs
|
|
if attr and attr['lvm_vg_name']:
|
|
# the lvm_pv_name for cinder volumes is always /dev/drbd4
|
|
if attr['lvm_vg_name'] == constants.LVG_CINDER_VOLUMES:
|
|
attr['lvm_pv_name'] = constants.CINDER_DRBD_DEVICE
|
|
for pv in ipv:
|
|
# ignore duplicates
|
|
if pv['lvm_pv_name'] == attr.get('lvm_pv_name'):
|
|
break
|
|
else:
|
|
ipv.append(attr)
|
|
|
|
LOG.debug("ipv= %s" % ipv)
|
|
|
|
return ipv
|
|
|
|
def ipv_delete(self, ipv_dict):
|
|
"""Delete LVM physical volume
|
|
|
|
Also delete Logical volume Group if PV is last in group
|
|
|
|
:param ipv_dict: values for physical volume object
|
|
:returns: pass or fail
|
|
"""
|
|
LOG.info("Deleting PV: %s" % (ipv_dict))
|
|
|
|
if ipv_dict['lvm_vg_name'] == constants.LVG_CINDER_VOLUMES:
|
|
# disable LIO targets before cleaning up volumes
|
|
# as they may keep the volumes busy
|
|
LOG.info("Clearing LIO configuration")
|
|
cutils.execute('targetctl', 'clear',
|
|
run_as_root=True)
|
|
# Note: targets are restored from config file by Cinder
|
|
# on restart. Restarts should done after 'cinder-volumes'
|
|
# re-configuration
|
|
|
|
# Check if LVG exists
|
|
stdout, __ = cutils.execute('vgs', '--reportformat', 'json',
|
|
run_as_root=True)
|
|
data = json.loads(stdout)['report']
|
|
LOG.debug("ipv_delete vgs data: %s" % data)
|
|
vgs = []
|
|
for vgs_entry in data:
|
|
if type(vgs_entry) == dict and 'vg' in vgs_entry.keys():
|
|
vgs = vgs_entry['vg']
|
|
break
|
|
for vg in vgs:
|
|
if vg['vg_name'] == ipv_dict['lvm_vg_name']:
|
|
break
|
|
else:
|
|
LOG.info("VG %s not found, "
|
|
"skipping removal" % ipv_dict['lvm_vg_name'])
|
|
vg = None
|
|
|
|
# Remove all volumes from volume group before deleting any PV from it
|
|
# (without proper pvmove the data will get corrupted anyway, so better
|
|
# we remove the data while the group is still clean)
|
|
if vg:
|
|
LOG.info("Removing all volumes "
|
|
"from LVG %s" % ipv_dict['lvm_vg_name'])
|
|
# VG exists, should not give any errors
|
|
# (make sure no FD is open when running this)
|
|
# TODO(oponcea): Run pvmove if multiple PVs are
|
|
# associated with the same LVG to avoid data loss
|
|
cutils.execute('lvremove',
|
|
ipv_dict['lvm_vg_name'],
|
|
'-f',
|
|
run_as_root=True)
|
|
|
|
# Check if PV exists
|
|
stdout, __ = cutils.execute('pvs', '--reportformat', 'json',
|
|
run_as_root=True)
|
|
data = json.loads(stdout)['report']
|
|
LOG.debug("ipv_delete pvs data: %s" % data)
|
|
pvs = []
|
|
for pvs_entry in data:
|
|
if type(pvs_entry) == dict and 'pv' in pvs_entry.keys():
|
|
for pv in pvs:
|
|
pvs = vgs_entry['pv']
|
|
break
|
|
for pv in pvs:
|
|
if (pv['vg_name'] == ipv_dict['lvm_vg_name'] and
|
|
pv['pv_name'] == ipv_dict['lvm_pv_name']):
|
|
break
|
|
else:
|
|
pv = None
|
|
|
|
# Removing PV. VG goes down with it if last PV is removed from it
|
|
if pv:
|
|
parm = {'dev': ipv_dict['lvm_pv_name'],
|
|
'vg': ipv_dict['lvm_vg_name']}
|
|
if (pv['vg_name'] == ipv_dict['lvm_vg_name'] and
|
|
pv['pv_name'] == ipv_dict['lvm_pv_name']):
|
|
LOG.info("Removing PV %(dev)s "
|
|
"from LVG %(vg)s" % parm)
|
|
cutils.execute('pvremove',
|
|
ipv_dict['lvm_pv_name'],
|
|
'--force',
|
|
'--force',
|
|
'-y',
|
|
run_as_root=True)
|
|
else:
|
|
LOG.warn("PV %(dev)s from LVG %(vg)s not found, "
|
|
"nothing to remove!" % parm)
|
|
|
|
try:
|
|
cutils.disk_wipe(ipv_dict['idisk_device_node'])
|
|
# Clean up the directory used by the volume group otherwise VG
|
|
# creation will fail without a reboot
|
|
vgs, __ = cutils.execute('vgs', '--noheadings',
|
|
'-o', 'vg_name',
|
|
run_as_root=True)
|
|
vgs = [v.strip() for v in vgs.split("\n")]
|
|
if ipv_dict['lvm_vg_name'] not in vgs:
|
|
cutils.execute('rm', '-rf',
|
|
'/dev/%s' % ipv_dict['lvm_vg_name'])
|
|
except exception.ProcessExecutionError as e:
|
|
LOG.warning("Continuing after wipe command returned exit code: "
|
|
"%(exit_code)s stdout: %(stdout)s err: %(stderr)s" %
|
|
{'exit_code': e.exit_code,
|
|
'stdout': e.stdout,
|
|
'stderr': e.stderr})
|
|
|
|
LOG.info("Deleting PV: %s completed" % (ipv_dict))
|