Merge "Update planning"

This commit is contained in:
Zuul 2021-03-25 11:09:32 +00:00 committed by Gerrit Code Review
commit 8ff2e4acee
9 changed files with 212 additions and 180 deletions

View File

@ -0,0 +1 @@
.. [#] See :ref:`Data Network Planning <data-network-planning>` for more information.

View File

@ -55,3 +55,7 @@ You must consider the following guidelines:
internal management network. To prevent loss of controller synchronization,
ensure that the switches and other devices on these networks are configured
with appropriate settings.
.. only:: partner
.. include:: ../../_includes/subnet-sizing-restrictions.rest

View File

@ -17,5 +17,9 @@ network for deployment reasons, or if it must support IPv6, you must configure
the optional untagged |PXE| boot network for |PXE| booting of new hosts using
IPv4.
.. only:: partner
.. include:: ../../_includes/subnet-sizing-restrictions.rest
.. note::
|prod| does not support IPv6 |PXE| booting.

View File

@ -8,7 +8,9 @@ IP Support
|prod| supports IPv4 and IPv6 versions for various networks.
The following table lists IPv4 and IPv6 support for different networks:
All networks must be a single address family, either IPv4 or IPv6, with the
exception of the |PXE| boot network which must always use IPv4. The following
table lists IPv4 and IPv6 support for different networks:
.. _network-requirements-ip-support-table-xqy-3cj-4cb:
@ -29,18 +31,12 @@ The following table lists IPv4 and IPv6 support for different networks:
* - Internal Management
- Y
- Y
- By default \(when |PXE| boot network is not present\), internal
management is used for |PXE| booting of new hosts. It must be untagged
and it must be IPv4. If, for deployment reasons, the internal management
network needs to be on a VLAN-tagged network, or if it needs to be IPv6,
you can configure the optional untagged |PXE| boot network for |PXE|
booting of new hosts using IPv4.
- -
* - OAM
- Y
- Y
- The OAM network supports IPv4 or IPv6 addressing. For more information,
see :ref:`OAM Network Planning <oam-network-planning>`.
* - Cluster Host Network
- -
* - Cluster Host
- Y
- Y
- The Cluster Host network supports IPv4 or IPv6 addressing.

View File

@ -70,3 +70,7 @@ guidelines:
internal management network. To prevent loss of controller synchronization,
ensure that the switches and other devices on these networks are configured
with appropriate settings.
.. only:: partner
.. include:: ../../_includes/subnet-sizing-restrictions.rest

View File

@ -117,8 +117,23 @@ in the following table.
Single-CPU Intel Xeon D-15xx Family, 8 cores \(low-power/low-cost
option for Simplex deployments\)
Platform: 2x physical cores \(4x logical cores if hyper-threading\), \(by default, configurable\)
Application: Remaining cores
* - Minimum Memory
- 64 GB
- - 64 GB
- Platform:
* Socket 0: 7GB \(by default, configurable\)
* Socket 1: 1GB \(by default, configurable\)
- Application:
* Socket 0: Remaining memory
* Socket 1: Remaining memory
* - Minimum Primary Disk
- 500 GB - |SSD| or |NVMe|
* - Additional Disks

View File

@ -45,3 +45,7 @@ exposed through |BGP| within the Calico |CNI| service. Calico |BGP|
configuration could be modified to advertise selected Application Container
services or the ingress controller service to a |BGP| Peer, specifying the
available next hop controller and/or worker nodes' cluster host IP Addresses.
.. only:: partner
.. include:: ../../_includes/subnet-sizing-restrictions.rest

View File

@ -6,178 +6,182 @@
Kubernetes Verified Commercial Hardware
=======================================
Verified and approved hardware components for use with |prod| are listed
here.
Verified and approved hardware components for use with |prod| are listed here.
.. _verified-commercial-hardware-verified-components:
.. table:: Table 1. Verified Components
:widths: 100, 200
:widths: auto
+----------------------------------------------------------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| Component | Approved Hardware |
+==========================================================+=============================================================================================================================================================================================================================================================================================================================================================================================================================================+
| Hardware Platforms | - Hewlett Packard Enterprise |
| | |
| | |
| | - HPE ProLiant DL360p Gen8 Server |
| | |
| | - HPE ProLiant DL360p Gen9 Server |
| | |
| | - HPE ProLiant DL360 Gen10 Server |
| | |
| | - HPE ProLiant DL380p Gen8 Server |
| | |
| | - HPE ProLiant DL380p Gen9 Server |
| | |
| | - HPE ProLiant ML350 Gen10 Server |
| | |
| | - c7000 Enclosure with HPE ProLiant BL460 Gen9 Server |
| | |
| | .. caution:: |
| | LAG support is dependent on the switch cards deployed with the c7000 enclosure. To determine whether LAG can be configured, consult the switch card documentation. |
| | |
| | |
| | - Dell |
| | |
| | |
| | - Dell PowerEdge R430 |
| | |
| | - Dell PowerEdge R630 |
| | |
| | - Dell PowerEdge R640 |
| | |
| | - Dell PowerEdge R720 |
| | |
| | - Dell PowerEdge R730 |
| | |
| | - Dell PowerEdge R740 |
| | |
| | |
| | - Kontron Symkloud MS2920 |
| | |
| | .. note:: |
| | The Kontron platform does not support power ON/OFF or reset through the BMC interface on |prod|. As a result, it is not possible for the system to properly fence a node in the event of a management network isolation event. In order to mitigate this, hosted application auto recovery needs to be disabled. |
+----------------------------------------------------------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| Supported Reference Platforms | - Intel Iron Pass |
| | |
| | - Intel Canoe Pass |
| | |
| | - Intel Grizzly Pass |
| | |
| | - Intel Wildcat Pass |
| | |
| | - Intel Wolf Pass |
+----------------------------------------------------------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| Disk Controllers | - Dell |
| | |
| | |
| | - PERC H310 Mini |
| | |
| | - PERC H730 Mini |
| | |
| | - PERC H740P |
| | |
| | - PERC H330 |
| | |
| | - PERC HBA330 |
| | |
| | |
| | |
| | - HPE Smart Array |
| | |
| | |
| | - P440ar |
| | |
| | - P420i |
| | |
| | - P408i-a |
| | |
| | - P816i-a |
| | |
| | |
| | - LSI 2308 |
| | |
| | - LSI 3008 |
+----------------------------------------------------------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| NICs Verified for PXE Boot, Management, and OAM Networks | - Intel I210 \(Springville\) 1G |
| | |
| | - Intel I350 \(Powerville\) 1G |
| | |
| | - Intel 82599 \(Niantic\) 10G |
| | |
| | - Intel X540 10G |
| | |
| | - Intel X710/XL710 \(Fortville\) 10G |
| | |
| | - Intel X722 \(Fortville\) 10G |
| | |
| | - Emulex XE102 10G |
| | |
| | - Broadcom BCM5719 1G |
| | |
| | - Broadcom BCM57810 10G |
| | |
| | - Mellanox MT27710 Family \(ConnectX-4 Lx\) 10G/25G |
| | |
| | - Mellanox MT27700 Family \(ConnectX-4\) 40G |
+----------------------------------------------------------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| NICs Verified for Data Interfaces [#]_ | The following NICs are supported: |
| | |
| | - Intel I350 \(Powerville\) 1G |
| | |
| | - Intel 82599 \(Niantic\) 10G |
| | |
| | - Intel X710/XL710 \(Fortville\) 10 G |
| | |
| | - Intel X552 \(Xeon-D\) 10G |
| | |
| | - Mellanox Technologies |
| | |
| | |
| | - MT27710 Family \(ConnectX-4\) 10G/25G |
| | |
| | - MT27700 Family \(ConnectX-4\) 40G |
| | |
+----------------------------------------------------------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| PCI passthrough or PCI SR-IOV NICs | - Intel 82599 \(Niantic\) 10 G |
| | |
| | - Intel X710/XL710 \(Fortville\) 10G |
| | |
| | - Mellanox Technologies |
| | |
| | |
| | - MT27500 Family \(ConnectX-3\) 10G \(support for PCI passthrough only\) [#]_ |
| | |
| | |
| | |
| | |
| | - MT27710 Family \(ConnectX-4\) 10G/25G |
| | |
| | - MT27700 Family \(ConnectX-4\) 40G |
| | |
| | |
| | .. note:: |
| | For a Mellanox CX3 using PCI passthrough or a CX4 using PCI passthrough or SR-IOV, SR-IOV must be enabled in the CX3/CX4 firmware. For more information, see `How To Configure SR-IOV for ConnectX-3 with KVM (Ethernet): Enable SR-IOV on the Firmware <https://community.mellanox.com/docs/DOC-2365#jive_content_id_I_Enable_SRIOV_on_the_Firmware>`__. |
| | |
| | |
| | .. note:: |
| | The maximum number of VFs per hosted application instance, across all PCI devices, is 32. |
| | |
| | For example, a hardware encryption hosted application can be launched with virtio interfaces and 32 QAT VFs. However, a hardware encryption hosted application with an SR-IOV network interface \(with 1 VF\) can only be launched with 31 VFs. |
| | |
| | .. note:: |
| | Dual-use configuration \(PCI passthrough or PCI SR-IOV on the same interface\) is supported for Fortville NICs only. |
+----------------------------------------------------------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| PCI SR-IOV Hardware Accelerators | - Intel AV-ICE02 VPN Acceleration Card, based on the Intel Coleto Creek 8925/8950, and C62x device with QuickAssist ®. |
+----------------------------------------------------------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| GPUs Verified for PCI Passthrough | - NVIDIA Corporation: VGA compatible controller - GM204GL \(Tesla M60 rev a1\) |
+----------------------------------------------------------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| Board Management Controllers | - HPE iLO3 |
| | |
| | - HPE iLO4 |
| | |
| | - Quanta |
+----------------------------------------------------------+---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| Component | Approved Hardware |
+================================================================================+========================================================================================================================================================================================================================================================================================================================================================================================================================================+
| Hardware Platforms | - Hewlett Packard Enterprise |
| | |
| | |
| | - HPE ProLiant DL360p Gen8 Server |
| | |
| | - HPE ProLiant DL360p Gen9 Server |
| | |
| | - HPE ProLiant DL360 Gen10 Server |
| | |
| | - HPE ProLiant DL380p Gen8 Server |
| | |
| | - HPE ProLiant DL380p Gen9 Server |
| | |
| | - HPE ProLiant ML350 Gen10 Server |
| | |
| | - c7000 Enclosure with HPE ProLiant BL460 Gen9 Server |
| | |
| | .. caution:: |
| | LAG support is dependent on the switch cards deployed with the c7000 enclosure. To determine whether LAG can be configured, consult the switch card documentation. |
| | |
| | - HPE ProLiant e910t Server Blade |
| | |
| | |
| | - Dell |
| | |
| | |
| | - Dell PowerEdge R430 |
| | |
| | - Dell PowerEdge R630 |
| | |
| | - Dell PowerEdge R640 |
| | |
| | - Dell PowerEdge R720 |
| | |
| | - Dell PowerEdge R730 |
| | |
| | - Dell PowerEdge R740 |
| | |
| | |
| | - Kontron Symkloud MS2920 |
| | |
| | .. note:: |
| | The Kontron platform does not support power ON/OFF or reset through the BMC interface on |prod|. As a result, it is not possible for the system to properly fence a node in the event of a management network isolation event. In order to mitigate this, hosted application auto recovery needs to be disabled. |
| | |
| | - ZTSystems Triton |
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| Supported Reference Platforms | - Intel Iron Pass |
| | |
| | - Intel Canoe Pass |
| | |
| | - Intel Grizzly Pass |
| | |
| | - Intel Wildcat Pass |
| | |
| | - Intel Wolf Pass |
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| Disk Controllers | - Dell |
| | |
| | |
| | - PERC H310 Mini |
| | |
| | - PERC H730 Mini |
| | |
| | - PERC H740P |
| | |
| | - PERC H330 |
| | |
| | - PERC HBA330 |
| | |
| | |
| | |
| | - HPE Smart Array |
| | |
| | |
| | - P440ar |
| | |
| | - P420i |
| | |
| | - P408i-a |
| | |
| | - P816i-a |
| | |
| | |
| | - LSI 2308 |
| | |
| | - LSI 3008 |
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| NICs Verified for PXE Boot, Management, and OAM Networks | - Intel I210 \(Springville\) 1G |
| | |
| | - Intel I350 \(Powerville\) 1G |
| | |
| | - Intel 82599 \(Niantic\) 10G |
| | |
| | - Intel X540 10G |
| | |
| | - Intel X710/XL710 \(Fortville\) 10G |
| | |
| | - Intel X722 \(Fortville\) 10G |
| | |
| | - Intel E810 25G Columbiaville \(Salem Channel\) NIC \(for management and OAM networks only\) |
| | |
| | - Emulex XE102 10G |
| | |
| | - Broadcom BCM5719 1G |
| | |
| | - Broadcom BCM57810 10G |
| | |
| | - Mellanox MT27710 Family \(ConnectX-4 Lx\) 10G/25G |
| | |
| | - Mellanox MT27700 Family \(ConnectX-4\) 40G |
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| NICs Verified for Data Interfaces [#]_ | The following NICs are supported: |
| | |
| | - Intel I350 \(Powerville\) 1G |
| | |
| | - Intel 82599 \(Niantic\) 10G |
| | |
| | - Intel X710/XL710 \(Fortville\) 10 G |
| | |
| | - Intel X552 \(Xeon-D\) 10G |
| | |
| | - Mellanox Technologies |
| | |
| | |
| | - MT27710 Family \(ConnectX-4\) 10G/25G |
| | |
| | - MT27700 Family \(ConnectX-4\) 40G |
| | |
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| PCI-Passthrough or PCI SR-IOV NICs | - Intel E810 25G Columbiaville \(Salem Channel\) NIC \(SR-IOV only\) |
| | |
| | - Intel 82599 \(Niantic\) 10 G |
| | |
| | - Intel X710/XL710 \(Fortville\) 10G |
| | |
| | - Mellanox Technologies |
| | |
| | |
| | - MT27710 Family \(ConnectX-4\) 10G/25G |
| | |
| | - MT27700 Family \(ConnectX-4\) 40G |
| | |
| | |
| | .. note:: |
| | For a Mellanox using PCI passthrough or a CX4 using PCI passthrough or SR-IOV, SR-IOV must be enabled in the CX4 firmware. For more information, see, `HowTo Configure SR-IOV for ConnectX-4/ConnectX-5/ConnectX-6 with KVM (Ethernet) <https://community.mellanox.com/s/article/HowTo-Configure-SR-IOV-for-ConnectX-4-ConnectX-5-ConnectX-6-with-KVM-Ethernet#jive_content_id_I_Enable_SRIOV_on_the_Firmware>`__. |
| | |
| | |
| | .. note:: |
| | The maximum number of VFs per hosted application instance, across all PCI devices, is 32. |
| | |
| | For example, a hardware encryption hosted application can be launched with virtio interfaces and 32 QAT VFs. However, a hardware encryption hosted application with an SR-IOV network interface \(with 1 VF\) can only be launched with 31 VFs. |
| | |
| | .. note:: |
| | Dual-use configuration \(PCI passthrough or PCI SR-IOV on the same interface\) is supported for Fortville NICs only. |
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| PCI SR-IOV Hardware Accelerators | - Intel AV-ICE02 VPN Acceleration Card, based on the Intel Coleto Creek 8925/8950, and C62x device with QuickAssist ®. |
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| Hardware Accelerator Devices Verified for PCI-Passthrough or PCI SR-IOV Access | - ACC100 Adapter \(Mount Bryce\) - SRIOV only |
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| GPUs Verified for PCI Passthrough | - NVIDIA Corporation: VGA compatible controller - GM204GL \(Tesla M60 rev a1\) |
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
| Board Management Controllers | - HPE iLO3 |
| | |
| | - HPE iLO4 |
| | |
| | - Quanta |
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
.. include:: ../../_includes/verified-commercial-hardware.rest
.. include:: ../../_includes/release-notes-overview-footnote.rest