Dell server config change to address Redfish image mount failure (pick stx 6.0)
Signed-off-by: Juanita-Balaraj <juanita.balaraj@windriver.com> Change-Id: I4c961007efe448471691f3546d53eacbd7996fce
This commit is contained in:
@@ -161,3 +161,24 @@ Executing the dcmanager subcloud reinstall command in the Central Cloud:
|
|||||||
:start-after: begin-ref-4
|
:start-after: begin-ref-4
|
||||||
:end-before: end-ref-4
|
:end-before: end-ref-4
|
||||||
|
|
||||||
|
.. important::
|
||||||
|
|
||||||
|
**Limitation**: When you perform a touchless subcloud install with Redfish
|
||||||
|
using the :command:`dcmanager subcloud add` command for all servers with
|
||||||
|
iDRAC 9 firmware installed, the subcloud install fails due to an ISO image
|
||||||
|
insertion mount failure over an IPv6 network |prod-dc| system.
|
||||||
|
|
||||||
|
**Workaround**: For all Dell servers with iDRAC 9 firmware installed with
|
||||||
|
version 5.10.00.00 or below, System administrators must perform the
|
||||||
|
following steps:
|
||||||
|
|
||||||
|
.. rubric:: |proc|
|
||||||
|
|
||||||
|
#. Log in to the iDRAC 9 web interface and select, **Configuration \>
|
||||||
|
Virtual Console** from the drop-down menu.
|
||||||
|
|
||||||
|
#. Select **HTML5** (or any other option except eHTML5) from the
|
||||||
|
**Plug-in Type** drop-down menu.
|
||||||
|
|
||||||
|
#. Click **Apply** to apply the change.
|
||||||
|
|
||||||
|