Support for HPE Synergy compute module (dsR8) - draft

Create .rest files and fix link in table.

Signed-off-by: Elisamara Aoki Goncalves <elisamaraaoki.goncalves@windriver.com>
Change-Id: I2ab179aa3716c9e74876ee9e084b7f7b0ceec36c
This commit is contained in:
Elisamara Aoki Goncalves 2023-03-30 15:55:14 -03:00
parent cf558baf2c
commit 9410dd0488
5 changed files with 92 additions and 24 deletions

View File

@ -0,0 +1,2 @@
.. note-begin
.. note-end

View File

@ -0,0 +1,5 @@
.. hpe-begin
.. hpe-end
.. hard-drive-begin
.. hard-drive-end

View File

@ -21,7 +21,7 @@ host types are:
.. end-min-hw-reqs-common-intro .. end-min-hw-reqs-common-intro
.. ..
.. Simplex .. Simplex
.. ..
@ -48,7 +48,7 @@ host types are:
default, configurable) default, configurable)
Application: Remaining cores Application: Remaining cores
* - Minimum memory * - Minimum memory
- 64 GB - 64 GB
@ -57,16 +57,26 @@ host types are:
* Platform: * Platform:
- Socket 0: 7GB (by default, configurable) - Socket 0: 7GB (by default, configurable)
- Socket 1: 1GB (by default, configurable) - Socket 1: 1GB (by default, configurable)
* Application: * Application:
- Socket 0: Remaining memory - Socket 0: Remaining memory
- Socket 1: Remaining memory - Socket 1: Remaining memory
* - Primary disk * - Primary disk
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: starlingx
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: partner
.. include:: /_includes/prepare-servers-for-installation-91baad307173.rest
:start-after: primary-disk-begin
:end-before: primary-disk-end
* - Additional disks * - Additional disks
- * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD| - * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD|
@ -99,7 +109,7 @@ host types are:
* - USB Interface * - USB Interface
- 1 (Only required if used for initial installation of controller-0) - 1 (Only required if used for initial installation of controller-0)
* - Boot Order * - Boot Order
- HD, PXE, USB - HD, PXE, USB
@ -107,7 +117,7 @@ host types are:
- BIOS or |UEFI| - BIOS or |UEFI|
.. note:: .. note::
|UEFI Secure Boot and |UEFI| |PXE| boot over IPv6 are not |UEFI Secure Boot and |UEFI| |PXE| boot over IPv6 are not
supported. On systems with an IPv6 management network, you can use supported. On systems with an IPv6 management network, you can use
@ -122,7 +132,7 @@ host types are:
* VT for directed I/O enabled * VT for directed I/O enabled
* CPU power and performance policy set to performance * CPU power and performance policy set to performance
* |min-proc-idle-power| CPU C state control disabled * |min-proc-idle-power| CPU C state control disabled
* Plug & play |BMC| detection disabled * Plug & play |BMC| detection disabled
@ -149,7 +159,7 @@ Prepare bare metal servers
.. end-prepare-servers .. end-prepare-servers
.. ..
.. Duplex .. Duplex
.. ..
@ -187,7 +197,17 @@ host types are:
* - Minimum memory * - Minimum memory
- 64 GB - 64 GB
* - Primary disk * - Primary disk
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: starlingx
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: partner
.. include:: /_includes/prepare-servers-for-installation-91baad307173.rest
:start-after: primary-disk-begin
:end-before: primary-disk-end
* - Additional disks * - Additional disks
- * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD| - * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD|
@ -231,7 +251,7 @@ Prepare bare metal servers
.. end-prepare-servers-dx .. end-prepare-servers-dx
.. ..
.. Standard with storage .. Standard with storage
.. ..
@ -255,6 +275,7 @@ configuration.
Minimum hardware requirements Minimum hardware requirements
----------------------------- -----------------------------
The recommended minimum hardware requirements for bare metal servers for various The recommended minimum hardware requirements for bare metal servers for various
host types are: host types are:
@ -274,7 +295,17 @@ host types are:
- 64 GB - 64 GB
- 32 GB - 32 GB
* - Primary disk * - Primary disk
- 500 GB SSD or |NVMe| (see Configure |NVMe| Drive as Primary Disk)
.. only:: starlingx
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: partner
.. include:: /_includes/prepare-servers-for-installation-91baad307173.rest
:start-after: primary-disk-begin
:end-before: primary-disk-end
- 120 GB (Minimum 10k RPM) - 120 GB (Minimum 10k RPM)
* - Additional disks * - Additional disks
- * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD| - * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD|
@ -322,7 +353,7 @@ Prepare bare metal servers
.. end-prepare-servers-std .. end-prepare-servers-std
.. ..
.. Dedicated storage .. Dedicated storage
.. ..
@ -360,7 +391,7 @@ host types are:
- 2-9 - 2-9
- 2-100 - 2-100
* - Minimum processor class * - Minimum processor class
- Dual-CPU Intel® Xeon® E5 26xx family (SandyBridge) 8 cores/socket - Dual-CPU Intel® Xeon® E5 26xx family (SandyBridge) 8 cores/socket
- (Same as controller node) - (Same as controller node)
- (Same as controller node) - (Same as controller node)
* - Minimum memory * - Minimum memory
@ -368,7 +399,16 @@ host types are:
- 64 GB - 64 GB
- 32 GB - 32 GB
* - Primary disk * - Primary disk
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`) .. only:: starlingx
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
.. only:: partner
.. include:: /_includes/prepare-servers-for-installation-91baad307173.rest
:start-after: primary-disk-begin
:end-before: primary-disk-end
- 120 GB (min. 10k RPM) - 120 GB (min. 10k RPM)
- 120 GB (min. 10k RPM) - 120 GB (min. 10k RPM)
* - Additional disks * - Additional disks
@ -389,15 +429,15 @@ host types are:
* Data: 1 or more x 10GE * Data: 1 or more x 10GE
* - Bios settings * - Bios settings
- * Hyper-Threading technology enabled - * Hyper-Threading technology enabled
* Virtualization technology enabled * Virtualization technology enabled
* VT for directed I/O enabled * VT for directed I/O enabled
* CPU power and performance policy set to performance * CPU power and performance policy set to performance
* CPU C state control disabled * CPU C state control disabled
* Plug & play |BMC| detection disabled * Plug & play |BMC| detection disabled
- (Same as controller node) - (Same as controller node)
- (Same as controller node) - (Same as controller node)

View File

@ -44,5 +44,11 @@ persistent volume claim or container-ephemeral storage.
| | /dev/sdc | | | | | | | AIO-SX:superscript:`1:` (replication = 2) ; AIO-DX (replication = 2) | | | /dev/sdc | | | | | | | AIO-SX:superscript:`1:` (replication = 2) ; AIO-DX (replication = 2) |
+--------------+----------+-----------+-----------+-----------+-----------------------------------------------+-----------------------------+-------------------+-------------------------------------------------------------------------+ +--------------+----------+-----------+-----------+-----------+-----------------------------------------------+-----------------------------+-------------------+-------------------------------------------------------------------------+
.. only:: partner
.. include:: /_includes/controller-disk-configurations-for-all-in-one-systems.rest
:start-after: note-begin
:end-before: note-end
.. [#fntarg1] |AIO|-Simplex Ceph replication is disk-based. .. [#fntarg1] |AIO|-Simplex Ceph replication is disk-based.

View File

@ -6,8 +6,16 @@
Hard Drive Options Hard Drive Options
================== ==================
For hard drive storage, |prod| supports high-performance |SSD| and |NVMe| .. only:: starlingx
drives as well as rotational disks.
For hard drive storage, |prod| supports high-performance |SSD| and |NVMe|
drives as well as rotational disks.
.. only:: partner
.. include:: /_includes/hard-drive-options.rest
:start-after: hpe-begin
:end-before: hpe-end
To increase system performance, you can use a |SSD| or a |NVMe| drive on |prod| To increase system performance, you can use a |SSD| or a |NVMe| drive on |prod|
hosts in place of any rotational drive. |SSD| provides faster read-write access hosts in place of any rotational drive. |SSD| provides faster read-write access
@ -26,3 +34,10 @@ adapters is required.
To use an |NVMe| drive as a root drive, you must enable |UEFI| support in the To use an |NVMe| drive as a root drive, you must enable |UEFI| support in the
host BIOS. In addition, when installing the host, you must perform extra steps host BIOS. In addition, when installing the host, you must perform extra steps
to assign the drive as the boot device. to assign the drive as the boot device.
.. only:: partner
.. include:: /_includes/hard-drive-options.rest
:start-after: hard-drive-begin
:end-before: hard-drive-end