487d14aafc6a56d40ddbe40a301bef2e564c61bb
This update changes the default Maintenance Heartbeat period
from 100 msecs to 1 second (1000 msecs).
Test Plan:
PASS: Verify full deployment of WRCP AIO DX Plus 1 worker
PASS: Verify full deployment of 2+4+2 Standard System
PASS: Verify heartbeat period default is 1 second
Regression:
PASS: Verify AIO DX enable handler heartbeat soak
PASS: Verify AIO DX add handler heartbeat soak
PASS: Verify Standard controller enable handler heartbeat soak
PASS: Verify Standard controller add handler heartbeat soak
PASS: Verify Standard worker node enable handler heartbeat soak
PASS: Verify Standard worker node add handler heartbeat soak
PASS: Verify heartbeat loss handling with new default heartbeat period
PASS: Verify MNFA handling with with new default heartbeat period
PASS: Verify hostwd quorum process failure fault detection and
handling timing is not effected by new default heartbeat period.
PASS: Run WRCP DX Sanity on AIO DX and 2+4+2 Sandard system
Depends-On: https://review.opendev.org/c/starlingx/config/+/955893
Partial-Fix: 2117252
Change-Id: Iaae2cc0efca92aa751e9404c886ac569d238be86