File location changes to support DS flattend Install TOC Add minitocs and remove duplicate include directive Convert images to figures and add captions Incorporate server prep. steps Add links to post-install steps. Inline overview and HW topics in procs. Patchset 1 review updates. Rework to reuse some StX install content in partner context and some partner install content in StX context. Conditionalize ipv6_note Share aio_duplex_extend Conditionalize Openstack prod name Add HW requirement includes for worker and storage nodes. Link worker and stor reqs to DX, StD and Dedicated install topics. Fix comment notation Correct for duplicate strings in output Updates and additions based on GW review Make ansible_install_time_only note available DS. Move link target from r6 > r7 Temporarily restore alarms to satisfy build Migrate DX flattening to new layout Additional HW requirements to DX, Std and Dedicated tables. Migrate Standard flattening to new layout Roll this-ver forward to r7 Migrate Dedicated Storage flattening to new layout Address review comments. Standardize HW requirement tables Support horizontally conditionalized inline content Address additional review comments Signed-off-by: Ron Stone <ronald.stone@windriver.com> Change-Id: I14c8a1e51f6b6ceff69be063a654b4aadb7d3b8c
701 lines
19 KiB
ReStructuredText
701 lines
19 KiB
ReStructuredText
|
|
=====================
|
|
Hardware Requirements
|
|
=====================
|
|
|
|
.. begin-min-hw-reqs-common-intro
|
|
|
|
.. ........
|
|
.. Preamble common to all deployments
|
|
.. ........
|
|
|
|
-----------------------------
|
|
Minimum hardware requirements
|
|
-----------------------------
|
|
|
|
This section describes the hardware requirements and server preparation for a
|
|
|prod-long| |this-ver| |bare-metal| deployment.
|
|
|
|
.. contents::
|
|
:local:
|
|
:depth: 1
|
|
|
|
The recommended minimum hardware requirements for |bare-metal| servers for various
|
|
host types are:
|
|
|
|
.. end-min-hw-reqs-common-intro
|
|
|
|
.. ........
|
|
.. Simplex
|
|
.. ........
|
|
|
|
.. begin-prepare-servers
|
|
.. begin-min-hw-reqs-sx
|
|
|
|
|
|
The recommended minimum hardware requirements for |bare-metal| servers for various
|
|
host types are:
|
|
|
|
|
|
.. list-table::
|
|
:header-rows: 1
|
|
|
|
* - Minimum Requirements
|
|
- All-in-one Controller Node
|
|
* - Number of servers
|
|
- 1
|
|
* - Minimum processor class
|
|
- Dual-CPU Intel® Xeon® E5 26xx family (SandyBridge) 8 cores/socket
|
|
|
|
or
|
|
|
|
Single-CPU Intel® Xeon® D-15xx family, 8 cores (low-power/low-cost option)
|
|
|
|
.. note::
|
|
|
|
* Platform: 2x physical cores (4x logical cores if hyper-threading), (by
|
|
default, configurable)
|
|
* Application: Remaining cores
|
|
* - Minimum memory
|
|
- 64 GB
|
|
|
|
* Platform:
|
|
|
|
- Socket 0: 7GB (by default, configurable)
|
|
|
|
- Socket 1: 1GB (by default, configurable)
|
|
|
|
* Application:
|
|
|
|
- Socket 0: Remaining memory
|
|
|
|
- Socket 1: Remaining memory
|
|
|
|
* - Primary disk
|
|
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
|
|
* - Additional disks
|
|
- * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD|
|
|
|
|
* Recommended, but not required: 1 or more |SSDs| or |NVMe| drives for
|
|
Ceph journals (min. 1024 MiB per |OSD| journal)
|
|
|
|
* Recommended, but not required: 1 or more 500G HDs (min. 10K RPM), |SSDs|
|
|
or |NVMe| drives for Container ephemeral disk storage.
|
|
|
|
.. only:: openstack
|
|
|
|
* For |prod-os|, we recommend 1 or more 500 GB (min. 10K RPM) for |VM| local
|
|
ephemeral storage
|
|
|
|
* - Minimum network ports
|
|
- * MGMT: 1x1GE ( Recommended: MGMT 2x10GE LAG ) *Only required if subcloud is
|
|
in Distributed Cloud*.
|
|
* |OAM|: 1x1GE (Recommended: |OAM|: 2x1GE LAG)
|
|
|
|
* Data: 1 or more x 10GE (Recommended: Data: 2x10GE |LAG|)
|
|
|
|
* - USB
|
|
- 1 (Only required if used for initial installation of controller-0).
|
|
* - Boot order
|
|
- HD, PXE, USB
|
|
* - BIOS mode
|
|
- BIOS or UEFI
|
|
|
|
.. note::
|
|
|
|
|UEFI| Secure Boot and |UEFI| |PXE| boot over IPv6 are not supported. On
|
|
systems with an IPv6 management network, you can use a separate IPv4
|
|
network for |PXE| boot. For more information, see
|
|
:ref:`configuring-a-pxe-boot-server-r7`.
|
|
* - BIOS settings
|
|
- * Hyper-Threading technology enabled
|
|
|
|
* Virtualization technology enabled
|
|
|
|
* VT for directed I/O enabled
|
|
|
|
* CPU power and performance policy set to performance
|
|
|
|
* Minimum Processor Idle Power; CPU C state control disabled
|
|
|
|
* Plug & play |BMC| detection disabled
|
|
|
|
.. end-min-hw-reqs-sx
|
|
|
|
--------------------------
|
|
Prepare bare metal servers
|
|
--------------------------
|
|
|
|
.. include:: prep_servers.txt
|
|
|
|
* Cabled for networking
|
|
|
|
* Far-end switch ports should be properly configured to realize the networking
|
|
shown in the diagram below.
|
|
|
|
.. figure:: /deploy_install_guides/r7_release/figures/starlingx-deployment-options-simplex.png
|
|
:scale: 50%
|
|
:alt: All-in-one Simplex deployment configuration
|
|
|
|
*All-in-one Simplex deployment configuration*
|
|
|
|
|
|
.. end-prepare-servers
|
|
|
|
|
|
.. ........
|
|
.. Duplex
|
|
.. ........
|
|
|
|
.. begin-prepare-servers-dx
|
|
.. begin-min-hw-reqs-dx
|
|
|
|
|
|
This section describes the hardware requirements and server preparation for a
|
|
|prod-long| |this-ver| |bare-metal| Duplex deployment configuration.
|
|
|
|
The recommended minimum hardware requirements for |bare-metal| servers for various
|
|
host types are:
|
|
|
|
.. list-table::
|
|
:header-rows: 1
|
|
|
|
* - Minimum Requirements
|
|
- All-in-one Controller Node
|
|
- Worker Node
|
|
* - Number of servers
|
|
- 2
|
|
- 2-|max-workers|
|
|
* - Minimum processor class
|
|
- * Dual-CPU Intel® Xeon® E5 26xx family (SandyBridge) 8 cores/socket
|
|
|
|
or
|
|
|
|
* Single-CPU Intel® Xeon® D-15xx family, 8 cores (low-power/low-cost option)
|
|
|
|
.. note::
|
|
|
|
* Platform: 2x physical cores (4x logical cores if hyper-threading), (by
|
|
default, configurable)
|
|
* Application: Remaining cores
|
|
- (Same as controller node)
|
|
* - Minimum memory
|
|
- 64 GB
|
|
|
|
* Platform:
|
|
|
|
- Socket 0: 7GB (by default, configurable)
|
|
|
|
- Socket 1: 1GB (by default, configurable)
|
|
|
|
* Application:
|
|
|
|
- Socket 0: Remaining memory
|
|
|
|
- Socket 1: Remaining memory
|
|
- 32 GB
|
|
* - Primary disk
|
|
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
|
|
- 120 GB (Minimum 10k RPM)
|
|
* - Additional disks
|
|
- * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD|
|
|
|
|
* Recommended, but not required: 1 or more |SSDs| or |NVMe| drives for
|
|
Ceph journals (min. 1024 MiB per |OSD| journal)
|
|
|
|
* Recommended, but not required: 1 or more 500G HDs (min. 10K RPM), |SSDs|
|
|
or |NVMe| drives for Container ephemeral disk storage.
|
|
|
|
* For |prod-os|, we recommend 1 or more 500 GB (min. 10K RPM) for |VM| local
|
|
ephemeral storage
|
|
|
|
- For |prod-os|, we recommend 1 or more 500 GB (min. 10K RPM) for |VM| local
|
|
ephemeral storage
|
|
* - Minimum network ports
|
|
- * MGMT: 1x1GE ( Recommended: MGMT 2x10GE LAG ).
|
|
|
|
* |OAM|: 1x1GE (Recommended: |OAM|: 2x1GE LAG)
|
|
|
|
* Data: 1 or more x 10GE (Recommended: Data: 2x10GE |LAG|)
|
|
|
|
- * Mgmt/Cluster: 1x10GE (Recommended: MGMT 2x10GE LAG)
|
|
|
|
* Data: 1 or more x 10GE (Recommended: Data 2x10GE LAG)
|
|
|
|
* - USB
|
|
- 1 (Only required if used for initial installation of controller-0).
|
|
-
|
|
* - Board Management
|
|
-
|
|
- 1 |BMC|
|
|
* - Boot order
|
|
- HD, PXE, USB
|
|
- HD, PXE
|
|
* - BIOS mode
|
|
- BIOS or UEFI
|
|
|
|
.. note::
|
|
|
|
|UEFI| Secure Boot and |UEFI| |PXE| boot over IPv6 are not supported. On
|
|
systems with an IPv6 management network, you can use a separate IPv4
|
|
network for |PXE| boot. For more information, see
|
|
:ref:`configuring-a-pxe-boot-server-r7`.
|
|
- BIOS or UEFI
|
|
* - Bios settings
|
|
- * Hyper-Threading technology enabled
|
|
|
|
* Virtualization technology enabled
|
|
|
|
* VT for directed I/O enabled
|
|
|
|
* CPU power and performance policy set to performance
|
|
|
|
* CPU C state control disabled
|
|
|
|
* Plug & play |BMC| detection disabled
|
|
|
|
- (Same as controller node)
|
|
|
|
.. end-min-hw-reqs-dx
|
|
|
|
--------------------------
|
|
Prepare bare metal servers
|
|
--------------------------
|
|
|
|
.. include:: prep_servers.txt
|
|
|
|
* Cabled for networking
|
|
|
|
* Far-end switch ports should be properly configured to realize the networking
|
|
shown in the diagram above.
|
|
|
|
|
|
.. end-prepare-servers-dx
|
|
|
|
.. ........
|
|
.. Standard with storage
|
|
.. ........
|
|
|
|
.. begin-prepare-servers-std
|
|
.. begin-min-hw-reqs-std
|
|
|
|
This section describes the hardware requirements and server preparation for a
|
|
|prod-long| |this-ver| |bare-metal| Standard with Controller Storage deployment
|
|
configuration.
|
|
|
|
The recommended minimum hardware requirements for |bare-metal| servers for various
|
|
host types are:
|
|
|
|
.. list-table::
|
|
:header-rows: 1
|
|
|
|
* - Minimum Requirements
|
|
- Controller Node
|
|
- Worker Node
|
|
* - Number of servers
|
|
- 2
|
|
- 2-|max-workers|
|
|
* - Minimum processor class
|
|
- Dual-CPU Intel® Xeon® E5 26xx family (SandyBridge) 8 cores/socket
|
|
|
|
.. note:: All cores are used by the platform.
|
|
- Dual-CPU Intel® Xeon® E5 26xx family (SandyBridge) 8 cores/socket
|
|
|
|
.. note::
|
|
|
|
* Platform: 1x physical cores (2x logical cores if hyper-threading),
|
|
(by default, configurable)
|
|
* Application: Remaining cores
|
|
* - Minimum memory
|
|
- 64 GB
|
|
- 32 GB
|
|
* - Primary disk
|
|
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
|
|
- 120 GB (Minimum 10k RPM)
|
|
* - Additional disks
|
|
- * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD|
|
|
|
|
* Recommended, but not required: 1 or more |SSDs| or |NVMe| drives for
|
|
Ceph journals (min. 1024 MiB per |OSD| journal)
|
|
- For |prod-os|, we recommend 1 or more 500 GB (min. 10K RPM) for |VM| local
|
|
ephemeral storage
|
|
|
|
Recommended but not required: 1 or more 500G HDs (min. 10K RPM), |SSDs| or
|
|
|NVMe| drives for Container ephemeral disk storage.
|
|
* - Minimum network ports
|
|
- * MGMT: 1x1GE (Recommended: MGMT 2x10GE LAG)
|
|
* |OAM|: 1x1GE (Recommended: |OAM|: 2x1GE LAG)
|
|
* Data: 1 or more x 10GE (Recommended: Data: 2x10GE |LAG|)
|
|
- * Mgmt/Cluster: 1x10GE (Recommended: MGMT 2x10GE LAG)
|
|
|
|
* Data: 1 or more x 10GE (Recommended: Data: 2x10GE |LAG|)
|
|
* - USB
|
|
- 1 (Only required if used for initial installation of controller-0).
|
|
-
|
|
* - Board Management
|
|
-
|
|
- 1 |BMC|
|
|
* - Boot order
|
|
- HD, PXE, USB
|
|
- HD, PXE
|
|
* - BIOS mode
|
|
- BIOS or UEFI
|
|
|
|
.. note::
|
|
|
|
|UEFI| Secure Boot and |UEFI| |PXE| boot over IPv6 are not supported. On
|
|
systems with an IPv6 management network, you can use a separate IPv4
|
|
network for |PXE| boot. For more information, see
|
|
:ref:`configuring-a-pxe-boot-server-r7`.
|
|
- BIOS or UEFI
|
|
* - Bios settings
|
|
- * Hyper-Threading technology enabled
|
|
|
|
* Virtualization technology (VTD, VTX) enabled
|
|
|
|
* VT for directed I/O enabled
|
|
|
|
* CPU power and performance policy set to performance
|
|
|
|
* CPU C state control disabled
|
|
|
|
* Plug & play |BMC| detection disabled
|
|
|
|
- (Same as controller node)
|
|
|
|
.. end-min-hw-reqs-std
|
|
|
|
--------------------------
|
|
Prepare bare metal servers
|
|
--------------------------
|
|
|
|
.. include:: prep_servers.txt
|
|
|
|
* Cabled for networking
|
|
|
|
* Far-end switch ports should be properly configured to realize the networking
|
|
shown in the diagram above.
|
|
|
|
|
|
.. end-prepare-servers-std
|
|
|
|
|
|
.. ........
|
|
.. Dedicated storage
|
|
.. ........
|
|
|
|
.. begin-prepare-servers-ded
|
|
.. begin-min-hw-reqs-ded
|
|
|
|
This section describes the hardware requirements and server preparation for a
|
|
|prod-long| |this-ver| |bare-metal| Standard with Dedicated Storage deployment
|
|
configuration.
|
|
|
|
The recommended minimum hardware requirements for |bare-metal| servers for various
|
|
host types are:
|
|
|
|
.. list-table::
|
|
:header-rows: 1
|
|
|
|
* - Minimum Requirements
|
|
- Controller Node
|
|
- Storage Node
|
|
- Worker Node
|
|
* - Number of servers
|
|
- 2
|
|
- 2-9
|
|
- 2-|max-workers|
|
|
* - Minimum processor class
|
|
- Dual-CPU Intel® Xeon® E5 26xx family (SandyBridge) 8 cores/socket
|
|
|
|
.. note:: All cores are used by the platform.
|
|
|
|
- Dual-CPU Intel® Xeon® E5 26xx family (SandyBridge) 8 cores/socket
|
|
|
|
.. note:: All cores are used for Ceph Storage Cluster.
|
|
|
|
- Dual-CPU Intel® Xeon® E5 26xx family (SandyBridge) 8 cores/socket
|
|
|
|
.. note::
|
|
|
|
* Platform: 1x physical cores (2x logical cores if hyper-threading),
|
|
(by default, configurable)
|
|
* Application: Remaining cores
|
|
|
|
* - Minimum memory
|
|
- 64 GB
|
|
- 64 GB
|
|
- 32 GB
|
|
* - Primary disk
|
|
- 500 GB SSD or |NVMe| (see :ref:`nvme_config`)
|
|
- 120 GB (min. 10k RPM)
|
|
- 120 GB (min. 10k RPM)
|
|
* - Additional disks
|
|
- None
|
|
- * 1 or more 500 GB (min. 10K RPM) for Ceph |OSD|
|
|
|
|
* Recommended, but not required: 1 or more |SSDs| or |NVMe| drives for
|
|
Ceph journals (min. 1024 MiB per |OSD| journal)
|
|
- For |prod-os|, we recommend 1 or more 500 GB (min. 10K RPM) for |VM| ephemeral
|
|
storage
|
|
|
|
Recommended, but not required: 1 or more 500G HDs (min. 10K RPM), |SSDs|
|
|
or |NVMe| drives for Container ephemeral disk storage.
|
|
|
|
* - Minimum network ports
|
|
- * MGMT: 1x1GE ( Recommended: MGMT 2x10GE LAG ).
|
|
* |OAM|: 1x1GE (Recommended: |OAM|: 2x1GE LAG)
|
|
* Data: 1 or more x 10GE (Recommended: Data: 2x10GE |LAG|)
|
|
- Mgmt: 1x10GE
|
|
- * Mgmt/Cluster: 1x10GE 1x10GE (Recommended: MGMT 2x10GE LAG)
|
|
|
|
* Data: 1 or more x 10GE (Recommended: Data 2x10GE LAG)
|
|
* - USB
|
|
- 1 (Only required if used for initial installation of controller-0).
|
|
-
|
|
-
|
|
* - Board Management
|
|
-
|
|
-
|
|
- 1 |BMC|
|
|
* - Boot order
|
|
- HD, PXE, USB
|
|
-
|
|
- HD, PXE
|
|
* - BIOS mode
|
|
- BIOS or UEFI
|
|
|
|
.. note::
|
|
|
|
|UEFI| Secure Boot and |UEFI| |PXE| boot over IPv6 are not supported. On
|
|
systems with an IPv6 management network, you can use a separate IPv4
|
|
network for |PXE| boot. For more information, see
|
|
:ref:`configuring-a-pxe-boot-server-r7`.
|
|
- BIOS or UEFI
|
|
- BIOS or UEFI
|
|
* - Bios settings
|
|
- * Hyper-Threading technology enabled
|
|
|
|
* Virtualization technology (VTD, VTX) enabled
|
|
|
|
* VT for directed I/O enabled
|
|
|
|
* CPU power and performance policy set to performance
|
|
|
|
* CPU C state control disabled
|
|
|
|
* Plug & play |BMC| detection disabled
|
|
- (Same as controller node)
|
|
- (Same as controller node)
|
|
|
|
.. end-min-hw-reqs-ded
|
|
|
|
--------------------------
|
|
Prepare bare metal servers
|
|
--------------------------
|
|
|
|
.. include:: prep_servers.txt
|
|
|
|
* Cabled for networking
|
|
|
|
* Far-end switch ports should be properly configured to realize the networking
|
|
shown in the diagram above.
|
|
|
|
|
|
.. end-prepare-servers-ded
|
|
|
|
.. start-prepare-servers-common
|
|
|
|
Preparing servers is the first step of the |prod| installation procedure.
|
|
|
|
|
|
Prior to starting the |prod| installation, ensure that the |bare-metal|
|
|
servers are in the following state:
|
|
|
|
- Physically installed.
|
|
|
|
- Cabled for power.
|
|
|
|
- Cabled for networking.
|
|
|
|
Far-end switch ports should be properly configured to realize the
|
|
networking shown in the diagram earlier in this topic.
|
|
|
|
- All disks are wiped.
|
|
|
|
This ensures that servers will boot from either the network or USB
|
|
storage, if present.
|
|
|
|
.. note::
|
|
|
|
The disks and disk partitions need to be wiped before the install.
|
|
Installing a Debian ISO may fail with a message that the system is
|
|
in emergency mode if the disks and disk partitions are not
|
|
completely wiped before the install, especially if the server was
|
|
previously running a CentOS ISO.
|
|
|
|
.. only:: partner
|
|
|
|
.. include:: /_includes/debian-rn-link-a90a7e432679.rest
|
|
|
|
- BIOS configured with Intel Virtualization (VTD, VTX)
|
|
|
|
- Disabled for controller-only servers and storage servers.
|
|
|
|
- Enabled for :hideable:`controller+worker (All-in-one) servers and` worker servers.
|
|
|
|
- The servers are powered off.
|
|
|
|
|
|
.. end-prepare-servers-common
|
|
|
|
|
|
.. ........
|
|
.. HW requirments for Worker nodes
|
|
.. ........
|
|
|
|
.. begin-worker-hw-reqs
|
|
|
|
.. list-table:: Worker Hardware Requirements
|
|
:widths: 6 25
|
|
:header-rows: 0
|
|
|
|
* - Minimum number of workers
|
|
- 2
|
|
* - Maximum number of workers
|
|
- |max-workers|
|
|
* - Minimum processor class
|
|
- Same as for controllers
|
|
* - Minimum memory
|
|
- 32 GB
|
|
* - Minimum Primary Disk (two-disk hardware RAID suggested)
|
|
- 120 GB (min. 10K RPM)
|
|
|
|
.. note:: Installation on software RAID is not supported.
|
|
* - Additional disks
|
|
- 500 GB (min. 10K RPM) - 1 or more
|
|
|
|
.. note::
|
|
|
|
Single-disk hosts are supported, but must not be used for local
|
|
ephemeral storage.
|
|
* - Network ports
|
|
|
|
(Typical deployment)
|
|
- * Mgmt and Cluster Host: 2 x 10GE LAG (shared interface)
|
|
* **Optional** external network ports 2 x 10GE LAG
|
|
* - Board Management Controller (BMC)
|
|
- 1 (required)
|
|
* - Bios settings
|
|
- * Boot order: HD, PXE
|
|
|
|
* Bios mode: BIOS or UEFI
|
|
|
|
.. note::
|
|
|
|
|UEFI| Secure Boot and |UEFI| |PXE| boot over IPv6 are not
|
|
supported. On systems with an IPv6 management network, you can use a
|
|
separate IPv4 network for |PXE| boot.
|
|
* Hyperthreading: Same as for controllers
|
|
* Power profile: Same as for controllers
|
|
* Intel Virtualization (VTD, VTX): Enabled
|
|
|
|
.. end-worker-hw-reqs
|
|
|
|
|
|
.. ........
|
|
.. HW requirments for Storage nodes
|
|
.. ........
|
|
|
|
.. begin-storage-hw-reqs
|
|
|
|
.. list-table:: Storage Hardware Requirements
|
|
:widths: 6 25
|
|
:header-rows: 0
|
|
|
|
* - Minimum number of nodes
|
|
|
|
(If Ceph storage is used)
|
|
- * 2 - 8 (for replication factor 2)
|
|
* 3 - 9 (for replication factor 3)
|
|
* - Minimum processor class
|
|
- Same as for controllers
|
|
* - Minimum memory
|
|
- Same as for controllers
|
|
* - Minimum Primary Disk (two-disk hardware RAID suggested)
|
|
- 120 GB (min. 10K RPM)
|
|
|
|
.. note:: Installation on software RAID is not supported.
|
|
* - Additional disks
|
|
- * 500 GB (min. 10K RPM) for OSD storage
|
|
* One or more |SSDs| or |NVMe| drives (recommended for Ceph journals);
|
|
min. 1024 MiB per journal.
|
|
* - Network ports
|
|
|
|
(Typical deployment)
|
|
- * Mgmt and Cluster Host: 2 x 10GE LAG (shared interface)
|
|
* - Board Management Controller (BMC)
|
|
- 1 (required)
|
|
* - Bios settings
|
|
- * Boot order: HD, PXE
|
|
* Bios mode: BIOS or UEFI
|
|
|
|
.. note::
|
|
|
|
|UEFI| Secure Boot and |UEFI| |PXE| boot over IPv6 are not
|
|
supported. On systems with an IPv6 management network, you can use a
|
|
separate IPv4 network for |PXE| boot.
|
|
* Hyperthreading: Same as for controllers
|
|
* Power profile: Same as for controllers
|
|
* Intel Virtualization (VTD, VTX): Disabled
|
|
|
|
.. end-storage-hw-reqs
|
|
|
|
.. ........
|
|
.. Prepare Servers for Installation
|
|
.. ........
|
|
|
|
.. begin-prep-servers-common
|
|
.. begin-prepare-servers
|
|
|
|
Prior to starting the |prod| installation, the servers must be in the following
|
|
state:
|
|
|
|
- Physically installed.
|
|
|
|
- Cabled for power.
|
|
|
|
- Cabled for networking.
|
|
|
|
Far-end switch ports should be properly configured to realize the networking
|
|
shown in :ref:`deployment-options` for the particular deployment configuration
|
|
you are installing.
|
|
|
|
- All disks are wiped.
|
|
|
|
This ensures that servers will boot from either the network or USB storage,
|
|
if present.
|
|
|
|
.. note::
|
|
|
|
The disks and disk partitions need to be wiped before the install.
|
|
Installing a Debian ISO may fail with a message that the system is in
|
|
emergency mode if the disks and disk partitions are not completely wiped
|
|
before the install, especially if the server was previously running a
|
|
CentOS ISO.
|
|
|
|
.. only:: partner
|
|
|
|
.. include:: /_includes/debian-rn-link-a90a7e432679.rest
|
|
|
|
- BIOS configured with Intel Virtualization (VTD, VTX)
|
|
|
|
- Disabled for controller-only servers and storage servers.
|
|
|
|
- Enabled for controller+worker (All-in-one) servers and worker servers.
|
|
|
|
- The servers are powered off.
|
|
|
|
.. end-prepare-servers
|
|