[PTP SyncE] Update PTP alarm description

This commit updates the description and entity instance for the
PTP alarm for SyncE.

Story: 2009130
Task: 44497

Change-Id: Iefae1e75003ff2a45501e45d850f9556256d580f
Signed-off-by: Teresa Ho <teresa.ho@windriver.com>
This commit is contained in:
Teresa Ho 2022-02-15 08:48:26 -05:00
parent 6d30db1e0e
commit 6aeafb674d
1 changed files with 14 additions and 3 deletions

View File

@ -432,9 +432,16 @@
100.119:
Type: Alarm
Description:
major: "PTP configuration or out-of-tolerance timestamping conditions"
minor: "PTP out-of-tolerance timestamping condition"
Description: |-
<hostname> does not support the provisioned PTP mode
OR
<hostname> PTP clocking is out-of-tolerance
OR
<hostname> is not locked to remote PTP Grand Master
OR
<hostname> GNSS signal loss state:<state>
OR
<hostname> 1PPS signal loss state:<state>
Entity_Instance_ID: |-
host=<hostname>.ptp
OR
@ -447,6 +454,10 @@
host=<hostname>.ptp=<interface>.unsupported=legacy-timestamping
OR
host=<hostname>.ptp=out-of-tolerance
OR
host=<hostname>.instance=<instance>.ptp=out-of-tolerance
OR
host=<hostname>.interface=<interface>.ptp=signal-loss
Severity: [major, minor]
Proposed_Repair_Action: "Monitor and if condition persists, contact next level of support."
Maintenance_Action: none