This update delivers redfish support for Power-On/Off, Reset and Netboot Reinstall handling to maintenance. Test Plan: (Testing Continues) PASS: Verify Redfish Power-Off action handling PASS: Verify Redfish Power-On action handling PASS: Verify Redfish Reset action handling PASS: Verify compute Redfish Reinstall action handling from controller-0 PASS: Verify compute Redfish Reinstall action handling from controller-1 PASS: Verify Redfish Power-Off Action failure handling PASS: Verify Redfish Power-On action failure handling PASS: Verify Redfish Reset action failure handling PASS: Verify Redfish Re-Install action failure handling PASS: verify Reset progression cycle does not leak memory. PASS: Verify bmc_handler failure handling does not leak memory. PASS: Verify Inservice BMC access (ping) failure and recovery handling. PASS: Verify BMC access failure alarm handling PASS: Verify BMC provisioning and deprovisioning soak (redfish - wolfpass) PASS: Verify BMC provisioning and deprovisioning does not leak memory. PASS: Verify BMC provisioning handling with bad ip and/or bad username PASS: Verify BMC reprovisioning to same protocol PASS: Verify BMC reprovisioning from ipmi host to redfish host PASS: Verify BMC reprovisioning from redfish host to ipmi host PASS: Verify mixed protocol support in same lab PASS: Verify mixed server support in same lab PASS: Verify Large System Install with BMCs provisioned (wp8-12) PASS: Verify bmc access method (learn,ipmi,redfish) learned from mtc.init PASS: Verify Swact with BMCs provisioned. PASS: Verify no segfaults. PASS: Verify AIO System Install in lab that supports redfish (WC3-6, WP8-12, Dell 720 3-7) PASS: Verify AIO Simplex Install with Redfish Support (SM1, SM3) PASS: Verify AIO Duplex Install with Redfish Support (SM 5-6, Dell 720 1-2 Useability: PASS: Verify handling of reprovisioning BMC between hosts that support different protocols. PASS: Verify handling of reprovisioning ip address to host that leads to a different protocol select. PASS: Verify manual relearn handling to recover from errors that result from the above case. PASS: Verify host BMC deprovisioning handling and cleanup. PASS: Verify sensor monitoring. PASS: Verify fault insertion for both protocols and action handling. PASS: Verify protocol select handover. PASS: Verify hwmond sticks with a selected protocol once a sensor model has been created using that protocol. PASS: Verify handling of missing bmc_access_method configuration select. PASS: Verify inservice bmc_access_method service parameter modification handling. Regression: PASS: Verify redfish BMC info query logging. PASS: Verify sensor monitoring and alarming still works. PASS: Verify all power/reset/netboot commands for IPMI PASS: Verify reprovisioning soak of Wolfpass servers PASS: Verify reprovisioning soak of SM servers Depends-on: https://review.opendev.org/#/c/679178/ Change-Id: I984057e04d7426e37d675cf4d334a4e35419f2e8 Story: 2005861 Task: 35826 Task: 36606 Task: 36467 Task: 36456 Signed-off-by: Eric MacDonald <eric.macdonald@windriver.com>
193 lines
6.4 KiB
C++
193 lines
6.4 KiB
C++
#ifndef __INCLUDE_HWMONTHREAD_HH__
|
|
#define __INCLUDE_HWMONTHREAD_HH__
|
|
|
|
/*
|
|
* Copyright (c) 2016-2017 Wind River Systems, Inc.
|
|
*
|
|
* SPDX-License-Identifier: Apache-2.0
|
|
*
|
|
*/
|
|
|
|
/**
|
|
* @file
|
|
* Wind River Titanium Cloud Hardware Monitor Threads Header
|
|
*
|
|
*/
|
|
|
|
#define IPMITOOL_MAX_LINE_LEN (200)
|
|
#define IPMITOOL_MAX_FIELD_LEN (64)
|
|
#define IPMITOOL_FIT_LINE_LEN (1000)
|
|
|
|
#define REDFISH_SENSOR_LABEL_VOLT "Voltages"
|
|
#define REDFISH_SENSOR_LABEL_TEMP "Temperatures"
|
|
#define REDFISH_SENSOR_LABEL_FANS "Fans"
|
|
#define REDFISH_SENSOR_LABEL_POWER_SUPPLY "PowerSupplies"
|
|
#define REDFISH_SENSOR_LABEL_POWER_CTRL "PowerControl"
|
|
|
|
#define REDFISH_SENSOR_LABEL_VOLT_READING "ReadingVolts"
|
|
#define REDFISH_SENSOR_LABEL_TEMP_READING "ReadingCelsius"
|
|
#define REDFISH_SENSOR_LABEL_FANS_READING "Reading"
|
|
#define REDFISH_SENSOR_LABEL_POWER_SUPPLY_READING "None"
|
|
#define REDFISH_SENSOR_LABEL_POWER_CTRL_READING "PowerConsumedWatts"
|
|
|
|
#define REDFISH_SEVERITY__GOOD "OK"
|
|
#define REDFISH_SEVERITY__MAJOR "Warning"
|
|
#define REDFISH_SEVERITY__CRITICAL "Critical"
|
|
|
|
#define BMC_SENSOR_DEFAULT_UNIT_TYPE_TEMP "degrees"
|
|
#define BMC_SENSOR_DEFAULT_UNIT_TYPE_VOLT "Volts"
|
|
#define BMC_SENSOR_DEFAULT_UNIT_TYPE_FANS "RPM"
|
|
#define BMC_SENSOR_DEFAULT_UNIT_TYPE_POWER "Watts"
|
|
|
|
#define BMC_SENSOR_POWER_GROUP 0
|
|
#define BMC_SENSOR_THERMAL_GROUP 1
|
|
|
|
void * hwmonThread_bmc ( void * );
|
|
|
|
/* --------------------
|
|
* ipmitool_sensor_data: outgoing message
|
|
* --------------------
|
|
*
|
|
* The sensor data is formatted in a json style string that is sent
|
|
* to the hardware monitor daemon on the active controller as
|
|
* specified by the aformentioned configuration command.
|
|
*
|
|
* The following is a brief 3 sensor example of the expected
|
|
* ipmitool output and json string conversion that is sent to
|
|
* hardware mon.
|
|
*
|
|
* ipmitool output:
|
|
*
|
|
* Temp_CPU0 | 54.000 | % degrees C | ok | na | na | na | 86.000 | 87.000 | na
|
|
* PSU2 Input | 0.000 | % Watts | cr | na | 0.000 | na | na | na | na
|
|
* Critical IRQ | 0x0 | discrete | 0x0080| na | na | na | na | na | na
|
|
* Fan_SYS0_2 | 4700.000 | % RPM | ok | na | 500.000 | 1000.000 | na | na | na
|
|
*
|
|
* Message Design Strategy:
|
|
* 1. Maintain all the ipmitool output information so that it is available
|
|
* to the hardware monitor for future enhancements without the need to
|
|
* change the client side messaging.
|
|
* 2. Validate the format of the ipmitool output and report on any errors
|
|
* observed in a status field of the response string.
|
|
* 3. Deliver an industry standard json string formated message
|
|
* 4. Provide an overall status field indicating any formatting errors
|
|
* detected in the sensor data output format. This is not a summary
|
|
* status of the sensor data.
|
|
* 5. minimize the amount of data sent
|
|
* - use short sensor record labels
|
|
* n = name
|
|
* v = sensor reading value
|
|
* u = unit format used when interpreting the data
|
|
* s = correlated status
|
|
* - ipmitool labels for thresholds but only include labels for values that are not 'na'
|
|
* unr = Upper Non-Recoverable
|
|
* ucr = Upper Critical
|
|
* unc = Upper Non-Critical
|
|
* lnc = Lower Non-Critical
|
|
* lcr = Lower Critical
|
|
* lnr = Lower Non-Recoverable
|
|
*
|
|
* Json String: sensor data excluded
|
|
* -----------
|
|
*
|
|
* {
|
|
* "ipmitool_sensor_data":
|
|
* {
|
|
* "hostname" :"compute-0",
|
|
* "status" : 0,
|
|
* "status_string" : "pass",
|
|
* "sensors" :
|
|
* [
|
|
* { },
|
|
* { },
|
|
* { }
|
|
* ]
|
|
* }
|
|
*}
|
|
*
|
|
* Jason String: full
|
|
* -------------
|
|
*
|
|
*{
|
|
* "ipmitool_sensor_data":
|
|
* {
|
|
* "hostname" : "compute-0",
|
|
* "status" : 0,
|
|
* "status_string": "pass",
|
|
* "sensors":[
|
|
* {
|
|
* "n":"Temp_CPU0",
|
|
* "v":"54.000",
|
|
* "u":"% degrees C",
|
|
* "s":"ok",
|
|
* "unc":"86.000",
|
|
* "ucr":"87.000"
|
|
* },
|
|
* {
|
|
* "n":"PSU2 Input",
|
|
* "v":"0.000",
|
|
* "u":"% Watts",
|
|
* "s":"cr",
|
|
* "lcr":"0.000"
|
|
* },
|
|
* {
|
|
* "n":"Fan_SYS0_2",
|
|
* "v":"4700.00",
|
|
* "u":"% RPM",
|
|
* "s":"ok",
|
|
* "lcr":"500.000",
|
|
* "lnc":"1000.000"
|
|
* }
|
|
* ...
|
|
* ]
|
|
* }
|
|
*}
|
|
*
|
|
*
|
|
*/
|
|
|
|
#include <stdlib.h>
|
|
#include <string.h>
|
|
#include <unistd.h>
|
|
|
|
using namespace std;
|
|
|
|
#define THREAD_RETRY_DELAY_SECS (60)
|
|
#define MAX_THREAD_RETRIES (10)
|
|
|
|
#define BMC_JSON__SENSOR_DATA_MESSAGE_HEADER ((const char *)("bmc_sensor_data"))
|
|
|
|
#define BMC_JSON__SENSORS_LABEL ((const char *)("sensors"))
|
|
#define IPMITOOL_SENSOR_QUERY_CMD ((const char *)(" sensor list"))
|
|
|
|
#define BMC_POWER_SENSOR_OUTPUT_FILE_SUFFIX ((const char *)("_power_sensor_data"))
|
|
#define BMC_THERMAL_SENSOR_OUTPUT_FILE_SUFFIX ((const char *)("_thermal_sensor_data"))
|
|
|
|
#define REDFISHTOOL_READ_POWER_SENSORS_CMD ((const char *)("Chassis Power"))
|
|
#define REDFISHTOOL_READ_THERMAL_SENSORS_CMD ((const char *)("Chassis Thermal"))
|
|
|
|
typedef struct
|
|
{
|
|
char name [IPMITOOL_MAX_FIELD_LEN] ; /* sensor name */
|
|
char value [IPMITOOL_MAX_FIELD_LEN] ; /* sensor value */
|
|
char unit [IPMITOOL_MAX_FIELD_LEN] ; /* sensor unit type */
|
|
char status [IPMITOOL_MAX_FIELD_LEN] ; /* status - ok, nc, cr, nr */
|
|
char lnr [IPMITOOL_MAX_FIELD_LEN] ; /* Lower Non-Recoverable */
|
|
char lcr [IPMITOOL_MAX_FIELD_LEN] ; /* Lower Critical */
|
|
char lnc [IPMITOOL_MAX_FIELD_LEN] ; /* Lower Non-Critical */
|
|
char unc [IPMITOOL_MAX_FIELD_LEN] ; /* Upper Non-Critical */
|
|
char ucr [IPMITOOL_MAX_FIELD_LEN] ; /* Upper Critical */
|
|
char unr [IPMITOOL_MAX_FIELD_LEN] ; /* Upper Non-Recoverable */
|
|
} bmc_sample_type ;
|
|
|
|
typedef struct
|
|
{
|
|
string bm_ip ;
|
|
string bm_un ;
|
|
string bm_pw ;
|
|
|
|
int samples ;
|
|
} thread_extra_info_type ;
|
|
|
|
#endif // __INCLUDE_HWMONTHREAD_HH__
|