55d5f43edb
Maintenance heartbeat service should not be multicast messaging over an 'lo' interface which in IPv6 leads to socket failures, log flooding and the inability to detect and report pmond process failure. To fix that this update - configures pulse messaging to unicast for monitored networks configured as 'lo'. - prevents heartbeating over the cluster network if both it and the management network are both configured on the 'lo' interface. - improves logging to avoid flooding in the presence of socket setup or access errors. - stops logging netlink events (interface state changes) on unmonitored network interfaces. - maintains heartbeat disabled state until the management network is up. - modifies hbsAgent socket failure handling and its pmon conf file so that a persistent socket failure during startup is alarmed as an hbsAgent process failure. Test Plan: PASS: Verify logging over system install and socket errors PASS: Verify unicast messaging when cluster is set to 'lo' PASS: Verify no cluster network heartbeat when it and mgmnt are set to 'lo'. Regression: PASS: Verify heartbeat messaging and cluster info PASS: Verify pmond process failure alarm management PASS: Verify heartbeat failure detection and graceful recovery PASS: Verify AIO SX IPv6 system install and run PASS: Verify AIO DX IPv6 system install and run PASS: Verify Standard IPv6 system install and run PASS: Verify Storage system IPv6 install and run PASS: Verify Storage system IPv4 install and run PASS: Verify MNFA handling in IPv6 storage system Change-Id: I5a2a0b2dee0c690617c4e0b0e2ab8b1172b2dc49 Closes-Bug: 1884585 Signed-off-by: Eric MacDonald <eric.macdonald@windriver.com> |
||
---|---|---|
.. | ||