apiVersion: monitoring.coreos.com/v1
kind: PrometheusRule
metadata:
namespace: {{ .Release.Namespace }}
name: {{ include "dell-exporter.fullname" . }}
labels:
{{ include "dell-exporter.labels" . | indent 4 }}
spec:
groups:
- name: dell
rules:
- alert: DellSystemStatus
expr: |
dell_hw_system_status == 2
for: 1m
labels:
severity: P4
annotations:
summary: "[`{{`{{$labels.instance}}`}}`] System warning"
description: >
The host `{{`{{$labels.instance}}`}}` is reporting a non-critical status,
please investigate. If this is the only firing alert, please add
another one to handle the specific failure.
- alert: DellSystemStatus
expr: |
dell_hw_system_status == 1
for: 1m
labels:
severity: P3
annotations:
summary: "[`{{`{{$labels.instance}}`}}`] System failure"
description: >
The host `{{`{{$labels.instance}}`}}` is reporting a critical status,
please investigate. If this is the only firing alert, please add
another one to handle the specific failure.
- alert: DellFanFailure
expr: |
dell_hw_chassis_fan_status != 0
for: 1m
labels:
severity: P4
annotations:
summary: "[`{{`{{$labels.instance}}`}}`] Fan failure"
description: >
The `{{`{{$labels.fan}}`}}` on host `{{`{{$labels.instance}}`}}` is reporting
a failure, please replace it.
- alert: DellMemoryFailure
expr: |
dell_hw_chassis_memory_status != 0
for: 1m
labels:
severity: P4
annotations:
summary: "[`{{`{{$labels.instance}}`}}`] Memory failure"
description: >
The `{{`{{$labels.memory}}`}}` on host `{{`{{$labels.instance}}`}}` is reporting
a failure, please replace it.
- alert: DellPowerSupplyFailure
expr: |
dell_hw_ps_status != 0
for: 1m
labels:
severity: P3
annotations:
summary: "[`{{`{{$labels.instance}}`}}`] Power failure"
description: >
The PSU `{{`{{$labels.id}}`}}` on host `{{`{{$labels.instance}}`}}` is reporting
a failure, please investigate if power is lost or power supply
requires replacement.
- alert: DellHardwareStorageFailure
expr: |
dell_hw_storage_controller_status != 0
for: 1m
labels:
severity: P3
annotations:
summary: "[`{{`{{$labels.instance}}`}}`] Storage failure"
description: >
The storage controller `{{`{{$labels.id}}`}}` on host `{{`{{$labels.instance}}`}}`
is reporting a failure, please investigate inside the host and add the
appropriate alerting rules if no alerts except this one have fired.
- alert: DellChassisTemperature
expr: |
dell_hw_chassis_temps_reading > dell_hw_chassis_temps_max_warning
labels:
severity: P3
annotations:
summary: "[{{`{{$labels.instance}}`}}] {{`{{$labels.component}}`}}"
description: >
The component {{`{{$labels.component}}`}} is reporting temperatures
of {{`{{$value}}`}} which is above the critical reading for
{{`{{$labels.instance}}`}}.
- alert: DellChassisTemperature
expr: |
dell_hw_chassis_temps_reading > dell_hw_chassis_temps_max_warning
labels:
severity: P4
annotations:
summary: "[{{`{{$labels.instance}}`}}] {{`{{$labels.component}}`}}"
description: >
The component {{`{{$labels.component}}`}} is reporting temperatures
of {{`{{$value}}`}} which is above the warning reading for
{{`{{$labels.instance}}`}}.