Improve handling of major version upgrades
Setting the external_ids:ovn-match-northd-version value to 'true' will make the ovn-controller refrain from making updates to the data plane tables in the event of a version mismatch. This in combination with stopping the ovn-controller with the ovn-ctl stop_controller --restart command will allow upgrades to progress with little or no data plane downtime. (Note that we will accomplish this by a separate proposal to the OVN package itself in Ubuntu.) As soon as the central components are upgraded ovn-controller will notice and resume (re-)programming of the local Open vSwitch data plane. Closes-Bug: #1940043 Change-Id: I16fedbc455e25bec0de4a475a9daa55b700ab3a0