-- ===================================================================== -- Copyright (C) 2003 by HUAWEI TECHNOLOGIES. All rights reserved. -- -- Description: Huawei Configuration management MIB -- Reference: HUAWEI Enterprise MIB -- Version: V1.12 -- History: -- 2011-09-23 v1.13 hujian Added hwSysVoiceFileTable,hwSysVoiceFileNum,hwSysVoiceLicenseFile,hwSysCurVoiceFileIndex -- 2011-08-23 v1.12 niwei Added hwSysSwitchoverStateMultiTable -- 2011-04-26 V1.11 Zhang Yong Modified syntax of hwSysReloadReason, changed from size (1..255) to size (0..255). -- 2005-04-21 V1.10 Zhang Xianping Added traps for disk fault. -- 2003-05-28 V1.00 Yu Bo Initial version for first baseline. -- ===================================================================== HUAWEI-SYS-MAN-MIB DEFINITIONS ::= BEGIN IMPORTS PhysicalIndex FROM ENTITY-MIB EnabledStatus FROM P-BRIDGE-MIB OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP FROM SNMPv2-CONF Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, IpAddress, Unsigned32 FROM SNMPv2-SMI RowPointer, DateAndTime, DisplayString, RowStatus, TEXTUAL-CONVENTION FROM SNMPv2-TC hwDatacomm FROM HUAWEI-MIB; huaweiSystemManMIB MODULE-IDENTITY LAST-UPDATED "200212200000Z" -- December 20, 2002 GMT ORGANIZATION "Huawei Technologies Co., Ltd." CONTACT-INFO "VRP Team Huawei Technologies co.,Ltd. Huawei Bld.,NO.3 Xinxi Rd., Shang-Di Information Industry Base, Hai-Dian District Beijing P.R. China http://www.huawei.com Zip:100085" DESCRIPTION "The HUAWEI-SYS-MAN-MIB contains objects to manage the system. The module defines the information about system, such as system time, the current configuration file and system image file, system reload actions, and notifications. By querying the system time, configuration files and system image files, NMS can reboot the device in the specified time and the specified configuration and system image." ::= { hwDatacomm 19 } -- -- Node definitions -- HWPatchErrorType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION " description. " SYNTAX INTEGER { initNoMemory(1), initMemProtectFail(2), fetchInputIsNull(5), fetchFlagNotSame(6), fetchProgVerInvalid(7), fetchProgCrcInvalid(8), fetchPatNoInvalid(9), fetchTotalNumInvalid(10), fetchUnitCrcInvalid(11), fetchFuncNumTooMany(12), fetchTypeInvalid(13), fetchCommonAfterTemp(14), fetchLengthNotSuited(15), fetchCodeAddrNotSuited(16), fetchDataAddrNotSuited(17), fetchBaseAddrNotSuited(18), fetchCodeLenOverflow(19), fetchDataLenOverflow(20), fetchOldAfterIndependent(103), fetchUpdateDependency(104), chgproChangeModeFailed(30), activeNumInvalid(40), activeHasBeenActived(41), activeNotExist(42), activeStateInvalid(43), activeCodeAddrNotSuited(44), activeDataAddrNotSuited(45), activeBaseAddrNotSuited(46), activeFormatUnknown(47), runNumInvalid(55), runHasInRunning(56), runNotActive(57), runIdleState(58), runBadState(59), deactNumInvalid(70), deactRunOrActive(71), deactRunningState(72), deactBadState(73), removeNumInvalid(80), removeHasInIdle(81), removeBadStatus(82), caclcrcFileCrcInvalid(90), caclcrcUnitCrcInvalid(91), caclcrcOutputIsNull(92), caclcrcNumInvalid(93), caclcrcBadUnitCrc(95), showNumInvalid(100), showCodeLenIsZero(101), showDataLenIsZero(102), addlistBadParam(105), addlistMemAllocFail(106), depToListBadParamDep(107), depToListBadParamList(108), depToListMemFreeFail(109), depToListAddItemFail(110), listToDepBadParamDep(111), listToDepBadParamList(112), listToDepBadParamDepCount(113), updateDepBadParam(114), updateDepMemAllocFail(115), updateDepDepToListFail(116), updateDepToInterFail(117), updateDepFromInterFail(118), updateDepListToDepFail(119), depToInterBadParam(120), depToInterInvalidNo(121), depToInterAddFail(122), interToDepBadParam(123), interToDepAppendFail(124), appendListBadParam(125), appendListAddFail(126), indActiveBadParam(127), indActiveAlreadyActive(128), indActiveListFail(129), indActiveListGenFail(130), indActiveListAppendFail(131), indActiveMemFreeFail(132), indActiveDepIdle(133), indActiveDepInvalid(134), indActiveCodeAddrNotSuited(135), indActiveDataAddrNotSuited(136), indActiveBaseAddrNotSuited(137), indActiveNotLoaded(138), indActiveFuncFail(139), indPatchFileNoInd(140), indRunFail(141), indDeactiveFail(142), indRemoveFail(143), indGetDepOfPara(144), indGetDepOnPara(145), indGetDepOnFail(146), fetchBufferPara(147), fetchBufferFail(148), getStatePara(149), indActiveAlreadyRunning(150), indFreeListInputNull(151), indFreeListMemFreeErr(152), indBitTblToArrayInputNull(153), indBitTblToArrayFreeFail(154), indBitTblToArrayAllocFail(155), indBitTblToArrayBitsetMore(156), indBitTblToArrayBitsetLess(157), listToDepBadParamAllocFail(158), listToDepBadParamFreeFail(159), indDeactiveFreeNull(160), indRemoveFreeFail(161), getInfoBufNull(162), getInfoOutputNull(163), getInfoFlagNotSame(164), getInfoProgCrcInvalid(165), getInfoFileCrcInvalid(166), getInfoUnitCrcInvalid(167), indPatchOpNotconfig(169), normalOpNotconfig(170), indDeactiveDeative(173), indDeactiveRunning(174), indDeactiveInvalid(176), indRunDeactive(177), indRunRunning(178), indRunIdle(179), indRunInvalid(180), indActiveIdle(171), indActiveInvalid(172), indFetchActive(183), indFetchRunning(185), indFetchDeactive(184), indFetchInvalid(186), indRemoveIdle(181), indRemoveInvalid(182), patchFileNotExist(187), patchRestoreFailed(188), patchPackageError(189), unknown(65535) } huaweiSystemManMIBObjects OBJECT IDENTIFIER ::= { huaweiSystemManMIB 1 } hwSysClock OBJECT IDENTIFIER ::= { huaweiSystemManMIBObjects 1 } hwSysLocalClock OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the local time of the device." ::= { hwSysClock 1 } hwSysCurrent OBJECT IDENTIFIER ::= { huaweiSystemManMIBObjects 2 } hwSysCurTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSysCurEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The current status of system. A configuration file and an image file are used to describe the current status." ::= { hwSysCurrent 1 } hwSysCurEntry OBJECT-TYPE SYNTAX HwSysCurEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry of hwSysCurTable. It is indexed by hwSysCurEntPhysicalIndex." INDEX { hwSysCurEntPhysicalIndex } ::= { hwSysCurTable 1 } HwSysCurEntry ::= SEQUENCE { hwSysCurEntPhysicalIndex Integer32, hwSysCurCFGFileIndex Integer32, hwSysCurImageIndex Integer32, hwSysCurPafFileIndex Integer32, hwSysCurLicenseIndex Integer32, hwSysCurPatchFileIndex Integer32, hwSysCurVoiceFileIndex Integer32 } hwSysCurEntPhysicalIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of this object identifies the system index." ::= { hwSysCurEntry 1 } hwSysCurCFGFileIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the index of the configuration file in the configuration file list. The value is referenced from hwSysCFGFileTable. The value ranges from 1 to 2147483647. " ::= { hwSysCurEntry 2 } hwSysCurImageIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the index of the image file in the image file list. The value is referenced from hwSysImageTable. The value ranges from 1 to 2147483647. " ::= { hwSysCurEntry 3 } hwSysCurPafFileIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the index of the PAF file in the PAF file list. " ::= { hwSysCurEntry 4 } hwSysCurLicenseIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the index of the license file in the license file list. " ::= { hwSysCurEntry 5 } hwSysCurPatchFileIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the index of the patch file in the patch file list. " ::= { hwSysCurEntry 6 } hwSysCurVoiceFileIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the index of the configuration file in the configuration file list. The value is referenced from hwSysCFGFileTable. The value ranges from 1 to 2147483647. " ::= { hwSysCurEntry 7 } hwSysReload OBJECT IDENTIFIER ::= { huaweiSystemManMIBObjects 3 } hwSysReloadSchedule OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "The value of this object identifies the record number used when the device restarts. The value ranges from 0 to 2147483647. After the system restarts, the value returns to 0. 0: initial value. 65536: main board schedule method. " ::= { hwSysReload 1 } hwSysReloadAction OBJECT-TYPE SYNTAX INTEGER { reloadUnavailable(1), reloadOnSchedule(2), reloadAtOnce(3), reloadCancel(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object identifies restart types. 1: reloadUnavailable 2: reloadOnSchedule, indicating periodical restart 3: reloadAtOnce, indicating immediate restart without considering hwSysReloadScheduleTime 4: reloadCancel, indicating that all the planned restart activities are cancelled. If hwSysReloadSchedule is invalid or the rows that hwSysReloadScheduleEntry and hwSysReloadSchedule point to are not activated, all the restart activities are ignored and an inconsistent value is returned. When the restart of the system is complete or no restart activities exist, the value of this object is reloadUnavailable(1). " ::= { hwSysReload 2 } hwSysReloadScheduleTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSysReloadScheduleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A reload parameters table." ::= { hwSysReload 3 } hwSysReloadScheduleEntry OBJECT-TYPE SYNTAX HwSysReloadScheduleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hwSysReloadScheduleTable." INDEX { hwSysReloadScheduleIndex } ::= { hwSysReloadScheduleTable 1 } HwSysReloadScheduleEntry ::= SEQUENCE { hwSysReloadScheduleIndex Integer32, hwSysReloadEntity PhysicalIndex, hwSysReloadCfgFile Integer32, hwSysReloadImage Integer32, hwSysReloadReason DisplayString, hwSysReloadScheduleTime DateAndTime, hwSysReloadRowStatus RowStatus, hwSysReloadPafFile Integer32, hwSysReloadLicenseFile Integer32, hwSysReloadPatchFile Integer32, hwSysReloadPatchState INTEGER, hwSysReloadOperateDestType INTEGER, hwSysReloadOperateDestIndex DisplayString, hwSysReloadVoiceFile Integer32 } hwSysReloadScheduleIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of this object identifies the index of the instance. The value ranges from 0 to 2147483647." ::= { hwSysReloadScheduleEntry 1 } hwSysReloadEntity OBJECT-TYPE SYNTAX PhysicalIndex MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the index of the restarting entity. The value is referred to from entPhysicalTable. 1. When get/get-next, 1 means active main board, 2 means slave main board, 65535 means other board. 2. When set, 2 means slave main board, other values mean active main board. " ::= { hwSysReloadScheduleEntry 2 } hwSysReloadCfgFile OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object identifies the configuration file used after the restart. The value is limited by hwSysCFGFileTable. The value ranges from 0 to 2147483647. The default value is 0, which means the configuration file remains unchanged. " ::= { hwSysReloadScheduleEntry 3 } hwSysReloadImage OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object identifies the image file used after the restart. The value is limited by hwSysImageTable. The value ranges from 1 to 2147483647. " ::= { hwSysReloadScheduleEntry 4 } hwSysReloadReason OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the cause of the restart. The value is a string of 0 to 255 characters. After the system restarts, the character string is deleted. " ::= { hwSysReloadScheduleEntry 5 } hwSysReloadScheduleTime OBJECT-TYPE SYNTAX DateAndTime (SIZE(8)) MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the time of the restart. The only valid value of this object is an 8-byte string which indicates the local time of the switch. The maximum scheduled time is 30 days from the current system clock time. If the value set is earlier than the value of hwSysLocalClock or beyond the maximum scheduled time limit, a bad value error occurred. The value of all-zero octet strings indicates system restart at once if the reload action is reloadOnSchedule(1). " ::= { hwSysReloadScheduleEntry 6 } hwSysReloadRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "If one of values of hwSysReloadEntity, hwSysReloadCfgFile and hwSysReloadImage is invalid, the value of hwSysReloadRowStatus cannot be set to 'active'. A valid entry means the specified element is available in the current system. Reload an entity indexed by hwSysReloadEntity with the startup configuration file and the image may be not allowed. Herein the entry is invalid. " ::= { hwSysReloadScheduleEntry 7 } hwSysReloadPafFile OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object identifies the PAF file used after the restart." ::= { hwSysReloadScheduleEntry 8 } hwSysReloadLicenseFile OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object identifies the license file used after the restart." ::= { hwSysReloadScheduleEntry 9 } hwSysReloadPatchFile OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object identifies the patch file used after the restart." ::= { hwSysReloadScheduleEntry 10 } hwSysReloadPatchState OBJECT-TYPE SYNTAX INTEGER { run(1), unused(255) } MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object identifies the running status of the patch at the next startup. That is, whether the loaded patch is in the Run state at the next startup. run(1): indicates that the loaded patch is in the Run state at the next startup. unused(255): indicates that the loaded patch is in the original state at the next startup. " ::= { hwSysReloadScheduleEntry 11 } hwSysReloadOperateDestType OBJECT-TYPE SYNTAX INTEGER { all(1), slave(2), chassis(3), unused(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the object to be restarted." ::= { hwSysReloadScheduleEntry 12 } hwSysReloadOperateDestIndex OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the index of the board needs to be restarted. The get/get-next result is 'unused'. but, you can't use 'unused' to set. " ::= { hwSysReloadScheduleEntry 13 } hwSysReloadVoiceFile OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object identifies the license file used after the restart." ::= { hwSysReloadScheduleEntry 14 } hwSysReboot OBJECT-TYPE SYNTAX INTEGER { unused(1), rebootWholeRoute(2), rebootSlave(3), slaveSwitch(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object identifies the restart of the master and slave boards. Values are as follows unused(1): indicates that this value is not used. Generally, this value is read. rebootAllRoute(2): indicates that the integrated device is restarted. rebootSlave(3): indicates that the slave board is restarted. slaveSwitch(4): indicates that the switchover between the main and slave boards is performed. " ::= { hwSysReload 4 } hwSysSlaveSwitchEnable OBJECT-TYPE SYNTAX EnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object identifies whether the switchover between the main and the slave boards is enabled. enable(1): indicates that the switchover between the main and slave boards is enabled. disable(2): indicates that the switchover between the main and slave boards is not enabled. " ::= { hwSysReload 5 } hwSysLatestRebootErrorInfo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the cause of the last restart." ::= { hwSysReload 6 } hwSysSlaveSwitchTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSysSlaveSwitchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A slave switchover enable parameters table." ::= { hwSysReload 7 } hwSysSlaveSwitchEntry OBJECT-TYPE SYNTAX HwSysSlaveSwitchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hwSysSlaveSwitchTable." INDEX { hwSysSlaveSwitchIndex } ::= { hwSysSlaveSwitchTable 1 } HwSysSlaveSwitchEntry ::= SEQUENCE { hwSysSlaveSwitchIndex Integer32, hwSysSlaveSwitchChassisNum DisplayString, hwSysSlaveSwitchOperType INTEGER, hwSysSlaveSwitchEnableStatus EnabledStatus } hwSysSlaveSwitchIndex OBJECT-TYPE SYNTAX Integer32 (1..80) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of the object identifies the index of the table." ::= { hwSysSlaveSwitchEntry 1 } hwSysSlaveSwitchChassisNum OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the object identifies the chassis number." ::= { hwSysSlaveSwitchEntry 2 } hwSysSlaveSwitchOperType OBJECT-TYPE SYNTAX INTEGER { unused(1), slaveSwitch(2), slaveSwitchLock(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Operation type. The object has the following values: unused(1): means the default value. slaveswitch(2): perform force switchover. slaveswitchlock(3): enable the force switchover, this value should be used with the object of hwSysSlaveSwitchEnableStatus. " ::= { hwSysSlaveSwitchEntry 3 } hwSysSlaveSwitchEnableStatus OBJECT-TYPE SYNTAX EnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "The enable status of switchover for AMB (Active Main Board) and SMB (Standby Main Board). enable(1): enable the force switchover. disable(2): disable the force switchover. " ::= { hwSysSlaveSwitchEntry 4 } hwSysDelayReboot OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Restart the device at a delayed time. The delayed time can be set up to 43200 minutes. The node is used to set the delayed time, cancel the setting, or check the status of the delayed restart. If a value within the range of 0 to 43200 is entered, the delayed time is set. If the value 65535 is entered, the setting is cancelled. During system reboot, a return value 65534 is displayed if the Get or Walk operation is performed. Other values are invalid. " ::= { hwSysReload 8 } hwSysImage OBJECT IDENTIFIER ::= { huaweiSystemManMIBObjects 4 } hwSysImageNum OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the number of image files. The object calculates the number of image files given by hwSysImageTable. The value ranges from 0 to 2147483647. " ::= { hwSysImage 1 } hwSysImageTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSysImageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The system image management table." ::= { hwSysImage 2 } hwSysImageEntry OBJECT-TYPE SYNTAX HwSysImageEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A system image entry. Each entry consists of information of a system image. hwSysImageIndex exclusively decides an image file." INDEX { hwSysImageIndex } ::= { hwSysImageTable 1 } HwSysImageEntry ::= SEQUENCE { hwSysImageIndex Integer32, hwSysImageName DisplayString, hwSysImageSize Integer32, hwSysImageLocation DisplayString, hwSysImageVersion DisplayString, hwSysImageReason DisplayString } hwSysImageIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of this object identifies the index of the image file." ::= { hwSysImageEntry 1 } hwSysImageName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the name of the image file. A file name containing path and suffix is a string of 4 to 64 characters. " ::= { hwSysImageEntry 2 } hwSysImageSize OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the size of the image file. The value ranges from 0 to 2147483647, in bytes. The size depends on the actual file and is limited by the physical storage device. " ::= { hwSysImageEntry 3 } hwSysImageLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the location of the image file, namely the path. " ::= { hwSysImageEntry 4 } hwSysImageVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the version of the image file." ::= { hwSysImageEntry 5 } hwSysImageReason OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the error cause of the image file." ::= { hwSysImageEntry 6 } hwSysCFGFile OBJECT IDENTIFIER ::= { huaweiSystemManMIBObjects 5 } hwSysCFGFileNum OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the number of configuration files. The object calculates the number of configuration files given by hwSysCFGFileTable. The value ranges from 0 to 2147483647. " ::= { hwSysCFGFile 1 } hwSysCFGFileTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSysCFGFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of configuration files in this system." ::= { hwSysCFGFile 2 } hwSysCFGFileEntry OBJECT-TYPE SYNTAX HwSysCFGFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A configuration file entry. Each entry consists of information of a configuration file. hwSysCFGFileIndex exclusively decides a configuration file." INDEX { hwSysCFGFileIndex } ::= { hwSysCFGFileTable 1 } HwSysCFGFileEntry ::= SEQUENCE { hwSysCFGFileIndex Integer32, hwSysCFGFileName DisplayString, hwSysCFGFileSize Integer32, hwSysCFGFileLocation DisplayString, hwSysCFGFileReason DisplayString } hwSysCFGFileIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of this object identifies the index of the configuration file." ::= { hwSysCFGFileEntry 1 } hwSysCFGFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the name of the configuration file. Currently, Huawei products support two formats of configuration files, namely, .CFG and .ZIP. A file name containing path and suffix is a string of 4 to 64 characters. " ::= { hwSysCFGFileEntry 2 } hwSysCFGFileSize OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the size of the configuration file. The value ranges from 0 to 2147483647. " ::= { hwSysCFGFileEntry 3 } hwSysCFGFileLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the location of the configuration file, namely, the path." ::= { hwSysCFGFileEntry 4 } hwSysCFGFileReason OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the error cause of the configuration file." ::= { hwSysCFGFileEntry 5 } hwSysPafFile OBJECT IDENTIFIER ::= { huaweiSystemManMIBObjects 6 } hwSysPafFileNum OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the number of PAF files in the system." ::= { hwSysPafFile 1 } hwSysPafFileTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSysPafFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of paf files in this system." ::= { hwSysPafFile 2 } hwSysPafFileEntry OBJECT-TYPE SYNTAX HwSysPafFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A paf file entry. Each entry consists of information of a paf file. hwSysPafFileIndex exclusively decides a configuration file." INDEX { hwSysPafFileIndex } ::= { hwSysPafFileTable 1 } HwSysPafFileEntry ::= SEQUENCE { hwSysPafFileIndex Integer32, hwSysPafFileName DisplayString, hwSysPafFileSize Integer32, hwSysPafFileLocation DisplayString, hwSysPafFileVersion DisplayString } hwSysPafFileIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of this object identifies the index of this table." ::= { hwSysPafFileEntry 1 } hwSysPafFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the name of the PAF file." ::= { hwSysPafFileEntry 2 } hwSysPafFileSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the size of the PAF file." ::= { hwSysPafFileEntry 3 } hwSysPafFileLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the position of the PAF file." ::= { hwSysPafFileEntry 4 } hwSysPafFileVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the version of the PAF file." ::= { hwSysPafFileEntry 5 } hwSysLicenseFile OBJECT IDENTIFIER ::= { huaweiSystemManMIBObjects 7 } hwSysLicenseFileNum OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the number of license files in the system." ::= { hwSysLicenseFile 1 } hwSysLicenseFileTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSysLicenseFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of license files in this system." ::= { hwSysLicenseFile 2 } hwSysLicenseFileEntry OBJECT-TYPE SYNTAX HwSysLicenseFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A license file entry. Each entry consists of information of a license file. hwSysLicenseFileIndex exclusively decides a configuration file." INDEX { hwSysLicenseFileIndex } ::= { hwSysLicenseFileTable 1 } HwSysLicenseFileEntry ::= SEQUENCE { hwSysLicenseFileIndex Integer32, hwSysLicenseFileName DisplayString, hwSysLicenseFileSize Integer32, hwSysLicenseFileLocation DisplayString } hwSysLicenseFileIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of this object identifies the index of this table." ::= { hwSysLicenseFileEntry 1 } hwSysLicenseFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the name of the license file." ::= { hwSysLicenseFileEntry 2 } hwSysLicenseFileSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the size of the license file." ::= { hwSysLicenseFileEntry 3 } hwSysLicenseFileLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the position of the license file." ::= { hwSysLicenseFileEntry 4 } hwPatch OBJECT IDENTIFIER ::= { huaweiSystemManMIBObjects 8 } hwPatchBase OBJECT IDENTIFIER ::= { hwPatch 1 } hwPatchFileNum OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the number of patches in the system." ::= { hwPatchBase 1 } hwPatchRecordReset OBJECT-TYPE SYNTAX INTEGER { unused(1), resetPatchHistory(2), resetPatchError(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clear the patch records. unused(1): unused. resetPatchHistory(2): clears the hwPatchHistoryTable record. resetPatchError(3): clears the hwPatchErrorTable record." ::= { hwPatchBase 2 } hwPatchHistoryTableMax OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Set the size of hwPatchHistoryTable." ::= { hwPatchBase 3 } hwPatchTrapEnble OBJECT-TYPE SYNTAX EnabledStatus MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object determines whether to generate the trap of HUAWEI-SYS-MAN-MIB. enable(1): Trap is enabled. disable(2): Trap is not enabled." ::= { hwPatchBase 4 } hwPatchErrorTableMax OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object identifies the maximum number of recorded errors supported by hwPatchErrorTable." ::= { hwPatchBase 5 } hwPatchId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the patch ID on the device." ::= { hwPatchBase 6 } hwPatchLatestId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the latest patch ID on the device." ::= { hwPatchBase 7 } hwPatchFailReason OBJECT-TYPE SYNTAX INTEGER { patchOpenErr(1), getPatchErr(2), patchSpaceShortage(3), patchConflict(4), versionErr(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is an index that specifies patch fail reason." ::= { hwPatchBase 8 } hwPatchFileTable OBJECT-TYPE SYNTAX SEQUENCE OF HwPatchFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Patch file query table." ::= { hwPatch 2 } hwPatchFileEntry OBJECT-TYPE SYNTAX HwPatchFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines an entry in the hwPatchFileTable." INDEX { hwPatchFileIndex } ::= { hwPatchFileTable 1 } HwPatchFileEntry ::= SEQUENCE { hwPatchFileIndex Unsigned32, hwPatchFileName DisplayString, hwPatchFileSize Integer32, hwPatchFileLocation DisplayString, hwPatchFileVersion DisplayString } hwPatchFileIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of this object identifies the index of this table." ::= { hwPatchFileEntry 1 } hwPatchFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the name of a patch file." ::= { hwPatchFileEntry 2 } hwPatchFileSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the size of a patch file." ::= { hwPatchFileEntry 3 } hwPatchFileLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the position of a patch file." ::= { hwPatchFileEntry 4 } hwPatchFileVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the version of the patch file." ::= { hwPatchFileEntry 5 } hwLoadPatchTable OBJECT-TYPE SYNTAX SEQUENCE OF HwLoadPatchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The load table of the patch file. Load the patch file to the memory: hwSlotIndex:The slot ID of the destination device to be loaded by the patch file, hwPatchFileIndex:The index of the patch file, If hwSlotIndex is 128, it indicates all slots of the device." ::= { hwPatch 4 } hwLoadPatchEntry OBJECT-TYPE SYNTAX HwLoadPatchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines an entry in the hwLoadPatchTable." INDEX { hwPatchSlotIndex, hwPatchFileIndex } ::= { hwLoadPatchTable 1 } HwLoadPatchEntry ::= SEQUENCE { hwPatchLoadDestType INTEGER, hwPatchLoadDestIndex DisplayString, hwPatchLoadState INTEGER, hwLoadPatchRowState RowStatus } hwPatchLoadDestType OBJECT-TYPE SYNTAX INTEGER { all(1), slave(2), slot(3), chassis(4), unused(5) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the type of the board to be loaded with the patch." ::= { hwLoadPatchEntry 1 } hwPatchLoadDestIndex OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the index of the board to be loaded with the patch." ::= { hwLoadPatchEntry 2 } hwPatchLoadState OBJECT-TYPE SYNTAX INTEGER { loading(1), success(2), failure(3), none(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Patch loading state: loading(1):Patch is loading. success(2):Patch loading succeeded. failure(3):Patch loading failed. none(4):Patch and board do not match." ::= { hwLoadPatchEntry 3 } hwLoadPatchRowState OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object identifies the status of a row." ::= { hwLoadPatchEntry 51 } hwPatchInfo OBJECT IDENTIFIER ::= { hwPatch 5 } hwPatchTable OBJECT-TYPE SYNTAX SEQUENCE OF HwPatchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Running status transfer and query of the patch. If hwSlotIndex is 128, it indicates all slots of the device. If hwPatchNum is 65535, it indicates all patches of the specified slot. If hwPatchNum is 0, it indicates the NP patch of the specified slot. If hwPatchNum is in range from 1 to 200, it indicates the C patch of the specified slot. " ::= { hwPatchInfo 1 } hwPatchEntry OBJECT-TYPE SYNTAX HwPatchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines an entry in the hwPatchTable." INDEX { hwPatchSlotIndex, hwPatchIndex } ::= { hwPatchTable 1 } HwPatchEntry ::= SEQUENCE { hwPatchSlotIndex Integer32, hwPatchIndex Unsigned32, hwPatchUsedFileName DisplayString, hwPatchVersion DisplayString, hwPatchDescription DisplayString, hwPatchProgramVersion DisplayString, hwPatchFuncNum Integer32, hwPatchTextLen Integer32, hwPatchDataLen Integer32, hwPatchType INTEGER, hwPatchBuildTime DateAndTime, hwPatchActiveTime DateAndTime, hwPatchAdminStatus INTEGER, hwPatchOperateState INTEGER, hwPatchOperateDestType INTEGER, hwPatchOperateDestIndex DisplayString } hwPatchSlotIndex OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of this object identifies the index of the slot." ::= { hwPatchEntry 1 } hwPatchIndex OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the index of the patch." ::= { hwPatchEntry 2 } hwPatchUsedFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the name of the patch file." ::= { hwPatchEntry 3 } hwPatchVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the version of the patch file." ::= { hwPatchEntry 4 } hwPatchDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the description of the patch." ::= { hwPatchEntry 5 } hwPatchProgramVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the object identifies the version number of the host software." ::= { hwPatchEntry 6 } hwPatchFuncNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the number functions contained in the patch." ::= { hwPatchEntry 7 } hwPatchTextLen OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the length of the patch code." ::= { hwPatchEntry 8 } hwPatchDataLen OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the length of the patch data." ::= { hwPatchEntry 9 } hwPatchType OBJECT-TYPE SYNTAX INTEGER { hotCommon(1), hotTemporary(2), coolCommon(3), coolTemporary(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the patch type. hotCommon(1): indicates the common hot patch. hotTemporary(2): indicates the temporary hot patch. coolCommon(3): indicates the common cool patch. coolTemporary(4): indicates the temporary cool patch." ::= { hwPatchEntry 10 } hwPatchBuildTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the time when a patch file is built." ::= { hwPatchEntry 11 } hwPatchActiveTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the time when a patch file is activated." ::= { hwPatchEntry 12 } hwPatchAdminStatus OBJECT-TYPE SYNTAX INTEGER { run(1), active(2), deactive(3), delete(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The value of this object identifies the operation status of a patch. Run (1): indicates that the patch status is Run. Active(2): indicates the patch status is Active. Deactive(3): indicates the patch status is Deactive. Delete(4): indicates that the patch is deleted." ::= { hwPatchEntry 13 } hwPatchOperateState OBJECT-TYPE SYNTAX INTEGER { patchRunning(1), patchActive(2), patchDeactive(3), patchDeleting(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "status of the patch. patchRunning(1): indicates that current status of the patch is Run. patchActive(2): indicates that current status of the patch is Active. patchDeactive(3): indicates that current status of the patch is Deactive." ::= { hwPatchEntry 14 } hwPatchOperateDestType OBJECT-TYPE SYNTAX INTEGER { all(1), slave(2), slot(3), chassis(4), unused(5) } MAX-ACCESS read-create STATUS current DESCRIPTION "Patch operate object type,it combine with the hwPatchOperateDestIndex to note the operate object." ::= { hwPatchEntry 15 } hwPatchOperateDestIndex OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Patch operate object index,it combine with chassis,the value of the hwPatchOperateDestType to note the operate object.hwPatchOperateDestIndex is value such as ccc1,clc2 etc." ::= { hwPatchEntry 16 } hwPatchStateTable OBJECT-TYPE SYNTAX SEQUENCE OF HwPatchStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The statistics information of the C patch area on each slot." ::= { hwPatchInfo 2 } hwPatchStateEntry OBJECT-TYPE SYNTAX HwPatchStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines an entry in the hwPatchStateTable." INDEX { hwPatchSlotIndex } ::= { hwPatchStateTable 1 } HwPatchStateEntry ::= SEQUENCE { hwPatchNumMax Unsigned32, hwPatchIdleNum Integer32, hwPatchTextMax Integer32, hwPatchDataMax Integer32, hwPatchStateTextUsed Integer32, hwPatchStateDataUsed Integer32, hwPatchStateTotalPatchNum Integer32, hwPatchStateTempPatchNum Integer32, hwPatchStateCommonPatchNum Integer32, hwPatchStateRuningPatchNum Integer32, hwPatchStateActivePatchNum Integer32, hwPatchStateDeactivePatchNum Integer32 } hwPatchNumMax OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the maximum number of patches." ::= { hwPatchStateEntry 1 } hwPatchIdleNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the number of idle patches." ::= { hwPatchStateEntry 2 } hwPatchTextMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the size of the code in the patch area." ::= { hwPatchStateEntry 3 } hwPatchDataMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the size of the data in the patch area." ::= { hwPatchStateEntry 4 } hwPatchStateTextUsed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the size of the used code in the patch area." ::= { hwPatchStateEntry 5 } hwPatchStateDataUsed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the size of the used data in the patch area." ::= { hwPatchStateEntry 6 } hwPatchStateTotalPatchNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the total number of used patches." ::= { hwPatchStateEntry 7 } hwPatchStateTempPatchNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the total number of used temporary patches." ::= { hwPatchStateEntry 8 } hwPatchStateCommonPatchNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the total number of used common patches." ::= { hwPatchStateEntry 9 } hwPatchStateRuningPatchNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the number of patches in the Run state in the patch area." ::= { hwPatchStateEntry 10 } hwPatchStateActivePatchNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the number of patches in the Active state in the patch area." ::= { hwPatchStateEntry 11 } hwPatchStateDeactivePatchNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the number of patches in the Deactive state in the patch area." ::= { hwPatchStateEntry 12 } hwPatchHistoryTable OBJECT-TYPE SYNTAX SEQUENCE OF HwPatchHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Patch history table." ::= { hwPatchInfo 3 } hwPatchHistoryEntry OBJECT-TYPE SYNTAX HwPatchHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines an entry in the hwPatchHistoryTable." INDEX { hwPatchHistoryIndex } ::= { hwPatchHistoryTable 1 } HwPatchHistoryEntry ::= SEQUENCE { hwPatchHistoryIndex Unsigned32, hwPatchHistoryProgrameVersion DisplayString, hwPatchHistoryVersion DisplayString, hwSlotId Integer32, hwPacthBeginIndex Integer32, hwPatchEndIndex Integer32, hwPatchHistoryAction INTEGER, hwPatchHistoryBeginTime DateAndTime, hwPatchHistoryEndTime DateAndTime } hwPatchHistoryIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the index of the table." ::= { hwPatchHistoryEntry 1 } hwPatchHistoryProgrameVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the object identifies the version number of the image file." ::= { hwPatchHistoryEntry 2 } hwPatchHistoryVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the version of the patch." ::= { hwPatchHistoryEntry 3 } hwSlotId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the object identifies the slot number of the patch." ::= { hwPatchHistoryEntry 4 } hwPacthBeginIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the start ID of the loaded patch." ::= { hwPatchHistoryEntry 5 } hwPatchEndIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the end ID of the loaded patch." ::= { hwPatchHistoryEntry 6 } hwPatchHistoryAction OBJECT-TYPE SYNTAX INTEGER { running(1), active(2), deactive(3), delete(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the patch status." ::= { hwPatchHistoryEntry 7 } hwPatchHistoryBeginTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the start time of running the patch." ::= { hwPatchHistoryEntry 8 } hwPatchHistoryEndTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the end time of running the patch." ::= { hwPatchHistoryEntry 9 } hwPatchErrorTable OBJECT-TYPE SYNTAX SEQUENCE OF HwPatchErrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The error record table of patch operation." ::= { hwPatchInfo 4 } hwPatchErrorEntry OBJECT-TYPE SYNTAX HwPatchErrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines an entry in the hwPatchErrorTable." INDEX { hwPatchErrorIndex } ::= { hwPatchErrorTable 1 } HwPatchErrorEntry ::= SEQUENCE { hwPatchErrorIndex Unsigned32, hwPatchErrorSlot Unsigned32, hwPatchErrorPatchFileName DisplayString, hwPatchErrorPatchIndex Unsigned32, hwPatchErrorCode HWPatchErrorType } hwPatchErrorIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the index of the patch error." ::= { hwPatchErrorEntry 1 } hwPatchErrorSlot OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of the slot related to a patch error." ::= { hwPatchErrorEntry 2 } hwPatchErrorPatchFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the index of the patch file when the patch has an error." ::= { hwPatchErrorEntry 3 } hwPatchErrorPatchIndex OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the index of the patch when the patch has an error." ::= { hwPatchErrorEntry 4 } hwPatchErrorCode OBJECT-TYPE SYNTAX HWPatchErrorType MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the flag of the patch error." ::= { hwPatchErrorEntry 5 } hwBootRom OBJECT IDENTIFIER ::= { huaweiSystemManMIBObjects 11 } hwBootRomTable OBJECT-TYPE SYNTAX SEQUENCE OF HwBootRomEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Boot ROM startup parameter query table." ::= { hwBootRom 1 } hwBootRomEntry OBJECT-TYPE SYNTAX HwBootRomEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines an entry in the hwBootRomTable." INDEX { hwBootRomIndex } ::= { hwBootRomTable 1 } HwBootRomEntry ::= SEQUENCE { hwBootRomIndex INTEGER, hwBootRomBootDevice DisplayString, hwBootRomProcessorNo Integer32, hwBootRomHostName DisplayString, hwBootRomFileName DisplayString, hwBootRomIpOnEthernet IpAddress, hwBootRomIpOnBackPlane IpAddress, hwBootRomHostIp IpAddress, hwBootRomGatewayIp IpAddress, hwBootRomUserName DisplayString, hwBootRomPassword DisplayString, hwBootRomTargetName DisplayString, hwBootRomStartupScript DisplayString, hwBootRomXModemBaudRate Integer32, hwBootRomVersion Integer32 } hwBootRomIndex OBJECT-TYPE SYNTAX INTEGER { master(1), slave(2) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of this object identifies the index of the BootROM table. " ::= { hwBootRomEntry 1 } hwBootRomBootDevice OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the name of the BootROM startup device." ::= { hwBootRomEntry 2 } hwBootRomProcessorNo OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the number of the BootROM processor." ::= { hwBootRomEntry 3 } hwBootRomHostName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The object indicates the name of the BootROM host." ::= { hwBootRomEntry 4 } hwBootRomFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The object indicates the name of the BootROM file." ::= { hwBootRomEntry 5 } hwBootRomIpOnEthernet OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The object indicates the IP address of the BootROM Ethernet interface." ::= { hwBootRomEntry 6 } hwBootRomIpOnBackPlane OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The object indicates the IP address of the BootROM backplane." ::= { hwBootRomEntry 7 } hwBootRomHostIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The object indicates the IP address of the BootROM host." ::= { hwBootRomEntry 8 } hwBootRomGatewayIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The object indicates the IP address of the BootROM gateway." ::= { hwBootRomEntry 9 } hwBootRomUserName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The object indicates the name of the BootROM user." ::= { hwBootRomEntry 10 } hwBootRomPassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The object indicates the BootROM password." ::= { hwBootRomEntry 11 } hwBootRomTargetName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The object indicates the name of the BootROM target." ::= { hwBootRomEntry 12 } hwBootRomStartupScript OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The object indicates the BootROM startup script." ::= { hwBootRomEntry 13 } hwBootRomXModemBaudRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the object identifies the baud rate for transmitting the XModem data." ::= { hwBootRomEntry 14 } hwBootRomVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Boot ROM version." ::= { hwBootRomEntry 15 } hwSysUpgrade OBJECT IDENTIFIER ::= { huaweiSystemManMIBObjects 12 } hwSysUpgradeTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSysUpgradeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "ISSU upgrade table." ::= { hwSysUpgrade 1 } hwSysUpgradeEntry OBJECT-TYPE SYNTAX HwSysUpgradeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines an entry in the hwSysUpgradeTable." INDEX { hwIssuIndex } ::= { hwSysUpgradeTable 1 } HwSysUpgradeEntry ::= SEQUENCE { hwIssuIndex Integer32, hwIssuMode INTEGER, hwIssuImageFile DisplayString, hwIssuPafFile DisplayString, hwIssuLicenseFile DisplayString } hwIssuIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Set system issu table index." ::= { hwSysUpgradeEntry 1 } hwIssuMode OBJECT-TYPE SYNTAX INTEGER { issuUpgrade(1), issuPrecheck(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set system issu upgrade mode." ::= { hwSysUpgradeEntry 2 } hwIssuImageFile OBJECT-TYPE SYNTAX DisplayString (SIZE (1..127)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the image file." ::= { hwSysUpgradeEntry 3 } hwIssuPafFile OBJECT-TYPE SYNTAX DisplayString (SIZE (1..127)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the paf file." ::= { hwSysUpgradeEntry 4 } hwIssuLicenseFile OBJECT-TYPE SYNTAX DisplayString (SIZE (1..127)) MAX-ACCESS read-write STATUS current DESCRIPTION "The name of the license file." ::= { hwSysUpgradeEntry 5 } hwIssuState OBJECT-TYPE SYNTAX INTEGER { noIssuUpgrading(1), issuUpgrading(2), issuExceptional(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "System issu upgrade state." ::= { hwSysUpgrade 2 } hwIssuConditionCheck OBJECT-TYPE SYNTAX INTEGER { normal(1), notRealtimeBackup(2), slotAbnormal(3), configurationChange(4), otherAbnormal(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "System issu upgrade condition check. The default check result is normal." ::= { hwSysUpgrade 3 } hwSysSourceIndex OBJECT IDENTIFIER ::= { huaweiSystemManMIBObjects 13 } hwSysSourceIndexTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSysSourceIndexEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "System file Index query table." ::= { hwSysSourceIndex 1 } hwSysSourceIndexEntry OBJECT-TYPE SYNTAX HwSysSourceIndexEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines an entry in the hwBootRomTable." INDEX { hwSysFileType,hwSysFileName} ::= { hwSysSourceIndexTable 1 } HwSysSourceIndexEntry ::= SEQUENCE { hwSysFileType INTEGER, hwSysFileName OCTET STRING, hwSysFileIndex Integer32 } hwSysFileType OBJECT-TYPE SYNTAX INTEGER { image(1), config(2), paf(3), license(4), patch(5) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of this object is an index that indicates the type of a file." ::= { hwSysSourceIndexEntry 1 } hwSysFileName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..110)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object is an index that indicates the name of a file on the main control board." ::= { hwSysSourceIndexEntry 2 } hwSysFileIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the index of a file in the specified table. If the value is 0, it indicates that this file does not exist in the specified table." ::= { hwSysSourceIndexEntry 3 } hwSysRebootInfo OBJECT IDENTIFIER ::= { huaweiSystemManMIBObjects 14 } hwSysRebootTimes OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the device reboot times. " ::= { hwSysRebootInfo 1 } hwSysRebootRecordTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSysRebootRecordEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A reboot information record table." ::= { hwSysRebootInfo 2 } hwSysRebootRecordEntry OBJECT-TYPE SYNTAX HwSysRebootRecordEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hwSysReloadScheduleTable." INDEX { hwSysRebootRecordIndex } ::= { hwSysRebootRecordTable 1 } HwSysRebootRecordEntry ::= SEQUENCE { hwSysRebootRecordIndex Integer32, hwSysRebootReason INTEGER, hwSysRebootTime DateAndTime } hwSysRebootRecordIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of hwSysRebootRecordTable." ::= { hwSysRebootRecordEntry 1 } hwSysRebootReason OBJECT-TYPE SYNTAX INTEGER { manual(1), powerOff(2), unknown(3), schedule(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The reason of system's reboot." ::= { hwSysRebootRecordEntry 2 } hwSysRebootTime OBJECT-TYPE SYNTAX DateAndTime (SIZE (8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The time at which the reboot action occurred. we will only take octet strings with length 8 for this object which indicates the local time of the switch. The maximum scheduled time is 30 days from the current system clock time. field octets contents range ----- ------ -------- ----- 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 " ::= { hwSysRebootRecordEntry 3 } hwSysDeviceCheck OBJECT IDENTIFIER ::= { huaweiSystemManMIBObjects 15 } hwSysDeviceCheckStart OBJECT-TYPE SYNTAX INTEGER { checkStart(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set system check start." ::= { hwSysDeviceCheck 1 } hwSysDeviceCheckState OBJECT-TYPE SYNTAX INTEGER { done(1), checking(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Get system check state." ::= { hwSysDeviceCheck 2 } hwSysSwitchoverState OBJECT IDENTIFIER ::= { huaweiSystemManMIBObjects 19 } hwSysSwitchoverStateTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSysSwitchoverStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { hwSysSwitchoverState 1 } hwSysSwitchoverStateEntry OBJECT-TYPE SYNTAX HwSysSwitchoverStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hwSysSwitchoverStateTable." INDEX { hwSysSwitchoverStateIndex } ::= { hwSysSwitchoverStateTable 1 } HwSysSwitchoverStateEntry ::= SEQUENCE { hwSysSwitchoverStateIndex Integer32, hwSysSwitchoverSlotId Integer32, hwSysSwitchoverBoardType INTEGER, hwSysSwitchoverInfo OCTET STRING } hwSysSwitchoverStateIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the index of the table." ::= { hwSysSwitchoverStateEntry 1 } hwSysSwitchoverSlotId OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the slot number of the board." ::= { hwSysSwitchoverStateEntry 2 } hwSysSwitchoverBoardType OBJECT-TYPE SYNTAX INTEGER { master(1), slave(2), systemMaster(3), systemSlave(4), issuOldMaster(5), issuNewMaster(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the type of the board." ::= { hwSysSwitchoverStateEntry 3 } hwSysSwitchoverInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..190)) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object descries the real-time information of HA status." ::= { hwSysSwitchoverStateEntry 4 } hwSysSwitchoverStateMultiTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSysSwitchoverStateMultiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= { hwSysSwitchoverState 2 } hwSysSwitchoverStateMultiEntry OBJECT-TYPE SYNTAX HwSysSwitchoverStateMultiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry of hwSysSwitchoverStateMultiTable." INDEX { hwSysMultiSwtStateIndex } ::= { hwSysSwitchoverStateMultiTable 1 } HwSysSwitchoverStateMultiEntry ::= SEQUENCE { hwSysMultiSwtStateIndex Integer32, hwSysMultiSwtChassisId OCTET STRING, hwSysMultiSwtSlotId Integer32, hwSysMultiSwtBoardType INTEGER, hwSysMultiSwtInfo OCTET STRING } hwSysMultiSwtStateIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the index of the table." ::= { hwSysSwitchoverStateMultiEntry 1 } hwSysMultiSwtChassisId OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the chassis id." ::= { hwSysSwitchoverStateMultiEntry 2 } hwSysMultiSwtSlotId OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the slot number of the board." ::= { hwSysSwitchoverStateMultiEntry 3 } hwSysMultiSwtBoardType OBJECT-TYPE SYNTAX INTEGER { master(1), slave(2), systemMaster(3), systemSlave(4), issuOldMaster(5), issuNewMaster(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the type of the board." ::= { hwSysSwitchoverStateMultiEntry 4 } hwSysMultiSwtInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..190)) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object descries the real-time information of HA status." ::= { hwSysSwitchoverStateMultiEntry 5 } hwSysVoiceFile OBJECT IDENTIFIER ::= { huaweiSystemManMIBObjects 20 } hwSysVoiceFileNum OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the number of configuration files. The object calculates the number of configuration files given by hwSysCFGFileTable. The value ranges from 0 to 2147483647. " ::= { hwSysVoiceFile 1 } hwSysVoiceFileTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSysVoiceFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of configuration files in this system." ::= { hwSysVoiceFile 2 } hwSysVoiceFileEntry OBJECT-TYPE SYNTAX HwSysVoiceFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A configuration file entry. Each entry consists of information of a configuration file. hwSysCFGFileIndex exclusively decides a configuration file." INDEX { hwSysVoiceFileIndex } ::= { hwSysVoiceFileTable 1 } HwSysVoiceFileEntry ::= SEQUENCE { hwSysVoiceFileIndex Integer32, hwSysVoiceFileName DisplayString, hwSysVoiceFileSize Integer32, hwSysVoiceFileLocation DisplayString } hwSysVoiceFileIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The value of this object identifies the index of the configuration file." ::= { hwSysVoiceFileEntry 1 } hwSysVoiceFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the name of the configuration file. Currently, Huawei products support two formats of configuration files, namely, .CFG and .ZIP. A file name containing path and suffix is a string of 4 to 64 characters. " ::= { hwSysVoiceFileEntry 2 } hwSysVoiceFileSize OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The value of this object identifies the size of the configuration file. The value ranges from 0 to 2147483647. " ::= { hwSysVoiceFileEntry 3 } hwSysVoiceFileLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the location of the configuration file, namely, the path." ::= { hwSysVoiceFileEntry 4 } -- ------------------------------------------------------------- -- HUAWEI-SYS-MAN-MIB MIB - Notification Information -- ------------------------------------------------------------- huaweiSystemManMIBNotifications OBJECT IDENTIFIER ::= { huaweiSystemManMIB 2 } hwSysClockChangedNotification NOTIFICATION-TYPE OBJECTS { hwSysLocalClock } STATUS current DESCRIPTION "This object indicates the notification sent when the system clock changes. When the system clock changes, this trap is triggered. For example, the system clock is changed through command lines. " ::= { huaweiSystemManMIBNotifications 1 } hwSysReloadNotification NOTIFICATION-TYPE OBJECTS { hwSysReloadImage, hwSysReloadCfgFile, hwSysReloadReason, hwSysReloadScheduleTime, hwSysReloadAction, hwSysReloadPafFile, hwSysReloadLicenseFile, hwSysReloadPatchFile } STATUS current DESCRIPTION "This object indicates the restart notification." ::= { huaweiSystemManMIBNotifications 2 } hwSysMasterHDError NOTIFICATION-TYPE STATUS current DESCRIPTION "When the hard disk on master board cannot be read and written because of a certain error, the hard disk on master board is unregistered and the notification is sent. " ::= { huaweiSystemManMIBNotifications 3 } hwSysSlaveHDError NOTIFICATION-TYPE STATUS current DESCRIPTION "When the hard disk on slave board cannot be read and written because of a certain error, the hard disk on slave board is unregistered and the notification is sent. " ::= { huaweiSystemManMIBNotifications 4 } hwPatchTrap OBJECT IDENTIFIER ::= { huaweiSystemManMIBNotifications 5 } hwPatchErrorTrap NOTIFICATION-TYPE OBJECTS { hwPatchErrorSlot, hwPatchErrorPatchIndex, hwPatchErrorCode, hwPatchErrorPatchFileName } STATUS current DESCRIPTION "The trap is generated when the patch operation error occurs." ::= { hwPatchTrap 1 } hwPatchActiveOverTimeTrap NOTIFICATION-TYPE OBJECTS { hwPatchOperateState } STATUS current DESCRIPTION "The patch is not run within 24 hours after it is activated." ::= { hwPatchTrap 2 } hwPatchMalfunctionComebackTrap NOTIFICATION-TYPE OBJECTS { hwPatchOperateState } STATUS current DESCRIPTION "The patch operation is restored." ::= { hwPatchTrap 3 } hwPatchUpdateTrap NOTIFICATION-TYPE OBJECTS { hwPatchVersion, hwPatchType, hwPatchOperateState} STATUS current DESCRIPTION "The patch state change notification." ::= { hwPatchTrap 4 } hwSysMasterCfcardError NOTIFICATION-TYPE STATUS current DESCRIPTION "When the cfcard on master board can't be read and written because of some error, the Cfcard on master board will be unregistered and the notification is sent. " ::= { huaweiSystemManMIBNotifications 6 } hwSysSlaveCfcardError NOTIFICATION-TYPE STATUS current DESCRIPTION "When the cfcard on slave board can't be read and written because of some error, the Cfcard on slave board will be unregistered and the notification is sent. " ::= { huaweiSystemManMIBNotifications 7 } hwSysSlaveSwitchSuccessNotification NOTIFICATION-TYPE OBJECTS { hwSysSlaveSwitchChassisNum } STATUS current DESCRIPTION "This object indicates that the hwSysSlaveSwitchChassisNum chassis is successfully switched." ::= { huaweiSystemManMIBNotifications 8 } hwSysSlaveSwitchFailNotification NOTIFICATION-TYPE OBJECTS { hwSysSlaveSwitchChassisNum } STATUS current DESCRIPTION "This object indicates that the hwSysSlaveSwitchChassisNum chassis fails to be switched." ::= { huaweiSystemManMIBNotifications 9 } hwSysIssuNotification NOTIFICATION-TYPE OBJECTS { hwIssuState, hwIssuConditionCheck } STATUS current DESCRIPTION "When the ISSU upgrade over, it will send success or failed message." ::= { huaweiSystemManMIBNotifications 10 } hwPatchInstallFail NOTIFICATION-TYPE OBJECTS { hwPatchUsedFileName, hwPatchVersion, hwPatchFailReason } STATUS current DESCRIPTION "The patch package install fail notification." ::= { huaweiSystemManMIBNotifications 11 } hwPatchInstallFailClear NOTIFICATION-TYPE OBJECTS { hwPatchUsedFileName, hwPatchVersion, hwPatchFailReason } STATUS current DESCRIPTION "The patch package install fail clear notification." ::= { huaweiSystemManMIBNotifications 12 } hwSumUpgradeSuccess NOTIFICATION-TYPE OBJECTS { hwSysImageVersion } STATUS current DESCRIPTION "The patch package upgrade success notification" ::= { huaweiSystemManMIBNotifications 13 } hwSysCfgFileErrorNotification NOTIFICATION-TYPE OBJECTS { hwSysCFGFileName,hwSysCFGFileReason} STATUS current DESCRIPTION "This object notifies that some error occurs when the configuration file is specified as the next startup configuration file." ::= { huaweiSystemManMIBNotifications 14 } hwSysImageErrorNotification NOTIFICATION-TYPE OBJECTS { hwSysImageName,hwSysImageName,hwSysImageReason } STATUS current DESCRIPTION "The image file upgrade fail notification. The first hwSysImageName indicates the current image file, and the second hwSysImageName indicates the next startup image file." ::= { huaweiSystemManMIBNotifications 15 } huaweiSystemManMIBConformance OBJECT IDENTIFIER ::= { huaweiSystemManMIB 3 } huaweiSystemManMIBCompliances OBJECT IDENTIFIER ::= { huaweiSystemManMIBConformance 1 } huaweiSystemManMIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement the Huawei system management MIB." MODULE -- this module MANDATORY-GROUPS { huaweiSysClockGroup, huaweiSysReloadGroup, huaweiSysImageGroup, huaweiSysCFGFileGroup, huaweiSystemManNotificationGroup } ::= { huaweiSystemManMIBCompliances 1 } huaweiSystemManMIBGroups OBJECT IDENTIFIER ::= { huaweiSystemManMIBConformance 2 } huaweiSysClockGroup OBJECT-GROUP OBJECTS { hwSysLocalClock } STATUS current DESCRIPTION "A collection of objects providing mandatory system reload." ::= { huaweiSystemManMIBGroups 1 } huaweiSysReloadGroup OBJECT-GROUP OBJECTS { hwSysReloadSchedule, hwSysReloadAction, hwSysReloadImage, hwSysReloadCfgFile, hwSysReloadReason, hwSysReloadPatchFile, hwSysReloadLicenseFile, hwSysReloadPafFile, hwSysReloadPatchState, hwSysLatestRebootErrorInfo, hwSysReloadScheduleTime, hwSysReloadEntity, hwSysReloadRowStatus, hwSysReloadOperateDestType, hwSysReloadOperateDestIndex, hwSysSlaveSwitchChassisNum, hwSysSlaveSwitchOperType, hwSysSlaveSwitchEnableStatus,hwSysDelayReboot} STATUS current DESCRIPTION " A collection of objects providing mandatory system clock information." ::= { huaweiSystemManMIBGroups 2 } huaweiSysImageGroup OBJECT-GROUP OBJECTS { hwSysImageNum, hwSysImageName, hwSysImageSize, hwSysImageLocation, hwSysImageVersion } STATUS current DESCRIPTION "A collection of objects providing mandatory system image information." ::= { huaweiSystemManMIBGroups 3 } huaweiSysCFGFileGroup OBJECT-GROUP OBJECTS { hwSysCFGFileNum, hwSysCFGFileName, hwSysCFGFileSize, hwSysCFGFileLocation } STATUS current DESCRIPTION "A collection of objects providing mandatory system configureation file information." ::= { huaweiSystemManMIBGroups 4 } hwSysCurGroup OBJECT-GROUP OBJECTS { hwSysCurCFGFileIndex, hwSysCurImageIndex, hwSysCurPafFileIndex, hwSysCurLicenseIndex, hwSysCurPatchFileIndex, hwSysCurVoiceFileIndex } STATUS current DESCRIPTION "A collection of system current status." ::= { huaweiSystemManMIBGroups 5 } huaweiSystemManNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { hwSysClockChangedNotification, hwSysReloadNotification, hwSysSlaveSwitchSuccessNotification, hwSysSlaveSwitchFailNotification, hwSysIssuNotification, hwPatchInstallFail, hwPatchInstallFailClear, hwSumUpgradeSuccess, hwSysCfgFileErrorNotification, hwSysImageErrorNotification } STATUS current DESCRIPTION "A collection of notification." ::= { huaweiSystemManMIBGroups 6 } huaweiSystemHDNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { hwSysMasterHDError, hwSysSlaveHDError } STATUS current DESCRIPTION "A collection of notification about system hard disk." ::= { huaweiSystemManMIBGroups 7 } hwPatchLoadGroup OBJECT-GROUP OBJECTS { hwPatchLoadDestType, hwPatchLoadDestIndex, hwLoadPatchRowState } STATUS current DESCRIPTION "Description." ::= { huaweiSystemManMIBGroups 8 } hwPatchTrapsGrop NOTIFICATION-GROUP NOTIFICATIONS { hwPatchErrorTrap, hwPatchActiveOverTimeTrap, hwPatchMalfunctionComebackTrap } STATUS current DESCRIPTION "Patch operation error." ::= { huaweiSystemManMIBGroups 9 } hwPatchInfoGroup OBJECT-GROUP OBJECTS { hwPatchDescription, hwPatchFuncNum, hwPatchTextLen, hwPatchDataLen, hwPatchType, hwPatchAdminStatus, hwPatchStateTempPatchNum, hwPatchStateCommonPatchNum, hwPatchStateRuningPatchNum, hwPatchStateActivePatchNum, hwPatchStateDeactivePatchNum, hwPatchHistoryVersion, hwPatchStateTotalPatchNum, hwPatchStateDataUsed, hwPatchStateTextUsed, hwPatchDataMax, hwPatchTextMax, hwPatchIdleNum, hwPatchNumMax, hwPatchActiveTime, hwPatchBuildTime, hwPatchVersion, hwPatchHistoryProgrameVersion, hwPatchFileName, hwPatchUsedFileName, hwPatchErrorTableMax, hwPatchHistoryTableMax, hwPatchRecordReset, hwPatchProgramVersion, hwPatchOperateState, hwPatchErrorSlot, hwPatchErrorPatchIndex, hwPatchErrorCode, hwPatchHistoryBeginTime, hwPatchHistoryEndTime, hwPatchHistoryAction, hwPatchEndIndex, hwPatchTrapEnble, hwPacthBeginIndex, hwPatchId, hwPatchLatestId, hwSlotId, hwPatchErrorPatchFileName } STATUS current DESCRIPTION "Description." ::= { huaweiSystemManMIBGroups 10 } hwPatchFileGroup OBJECT-GROUP OBJECTS { hwPatchFileName, hwPatchFileSize, hwPatchFileLocation, hwPatchFileVersion, hwPatchFileNum } STATUS current DESCRIPTION "Description." ::= { huaweiSystemManMIBGroups 11 } hwSysPafFileGroup OBJECT-GROUP OBJECTS { hwSysPafFileName, hwSysPafFileSize, hwSysPafFileLocation, hwSysPafFileVersion, hwSysPafFileNum } STATUS current DESCRIPTION "Description." ::= { huaweiSystemManMIBGroups 13 } hwSysPafLicenseGroup OBJECT-GROUP OBJECTS { hwSysLicenseFileNum, hwSysLicenseFileName, hwSysLicenseFileSize, hwSysLicenseFileLocation } STATUS current DESCRIPTION "Description." ::= { huaweiSystemManMIBGroups 14 } hwSysRebootAndSwitchGrop OBJECT-GROUP OBJECTS { hwSysReboot, hwSysSlaveSwitchEnable } STATUS current DESCRIPTION "Description." ::= { huaweiSystemManMIBGroups 15 } hwBootRomGroup OBJECT-GROUP OBJECTS { hwBootRomBootDevice, hwBootRomHostName, hwBootRomFileName, hwBootRomIpOnEthernet, hwBootRomIpOnBackPlane, hwBootRomHostIp, hwBootRomGatewayIp, hwBootRomUserName, hwBootRomPassword, hwBootRomTargetName, hwBootRomStartupScript, hwBootRomXModemBaudRate, hwBootRomVersion, hwBootRomProcessorNo } STATUS current DESCRIPTION "Description." ::= { huaweiSystemManMIBGroups 16 } hwSystemCfcardNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { hwSysMasterCfcardError, hwSysSlaveCfcardError } STATUS current DESCRIPTION "A collection of notification about system cfcard." ::= { huaweiSystemManMIBGroups 17 } hwSysUpgradeGroup OBJECT-GROUP OBJECTS {hwIssuMode, hwIssuImageFile, hwIssuPafFile, hwIssuLicenseFile, hwIssuState, hwIssuConditionCheck} STATUS current DESCRIPTION "A collection of system upgrade." ::= { huaweiSystemManMIBGroups 18 } hwSysRebootInfoGroup OBJECT-GROUP OBJECTS { hwSysRebootTimes, hwSysRebootReason, hwSysRebootTime } STATUS current DESCRIPTION "A collection of system upgrade." ::= { huaweiSystemManMIBGroups 19 } hwSysDeviceCheckGroup OBJECT-GROUP OBJECTS {hwSysDeviceCheckStart, hwSysDeviceCheckState} STATUS current DESCRIPTION "A collection of system device checks." ::= { huaweiSystemManMIBGroups 20 } huaweiSysVoiceFileGroup OBJECT-GROUP OBJECTS { hwSysVoiceFileNum, hwSysVoiceFileName, hwSysVoiceFileSize, hwSysVoiceFileLocation } STATUS current DESCRIPTION "A collection of objects providing mandatory system configureation file information." ::= { huaweiSystemManMIBGroups 21 } END -- -- HUAWEI-SYS-MAN-MIB.mib --