compass-core/mibs/HUAWEI-DATASYNC.mib

354 lines
13 KiB
Plaintext

--==================================================================
-- Copyright (C) 2006 by HUAWEI TECHNOLOGIES. All rights reserved.
--
-- Description: HUAWEI DATASYNC MIB
-- Reference:
-- Version: V1.0
-- History:
-- <author>, <date>, <contents>
-- fengchong 2009-03-17
-- ==================================================================
-- ==================================================================
--
-- Variables and types are imported
--
-- ==================================================================
HUAWEI-DATASYNC-MIB DEFINITIONS ::= BEGIN
IMPORTS
hwDatacomm
FROM HUAWEI-MIB
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
FROM SNMPv2-CONF
TimeTicks, Integer32, Gauge32, OBJECT-TYPE, MODULE-IDENTITY,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString, RowStatus, TEXTUAL-CONVENTION
FROM SNMPv2-TC;
hwDataSync MODULE-IDENTITY
LAST-UPDATED "200903171027Z"
ORGANIZATION
"Huawei Technologies Co.,Ltd."
CONTACT-INFO
"VRP Team Huawei Technologies Co.,Ltd.
Huawei Bld.,NO.3 Xinxi Rd.,
Shang-Di Information Industry Base,
Hai-Dian District Beijing P.R. China
http://www.huawei.com
Zip:100085
"
DESCRIPTION
"The MIB module for Data sync between host and netmanager."
REVISION "200903171027Z"
DESCRIPTION
"The initial revision of this MIB module ."
::= { hwDatacomm 191 }
DateAndTime ::= TEXTUAL-CONVENTION
DISPLAY-HINT "2d-1d-1d,1d:1d:1d.1d,1a1d:1d"
STATUS current
DESCRIPTION
"A date-time specification.
field octets contents range
----- ------ -------- -----
1 1-2 year* 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minutes 0..59
6 7 seconds 0..60
(use 60 for leap-second)
7 8 deci-seconds 0..9
8 9 direction from UTC '+' / '-'
9 10 hours from UTC* 0..13
10 11 minutes from UTC 0..59
* Notes:
- the value of year is in network-byte order
- daylight saving time in New Zealand is +13
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be
displayed as:
1992-5-26,13:30:15.0,-4:0
Note that if only local time is known, then timezone
information (fields 8-10) is not present."
SYNTAX OCTET STRING (SIZE (8 | 11))
--
-- Node definitions
--
-- ==================================================================
--
-- ======================= definition begin =========================
--
-- ==================================================================
hwDataSyncScalarObjects OBJECT IDENTIFIER ::= { hwDataSync 1 }
hwDataSyncTableObjects OBJECT IDENTIFIER ::= { hwDataSync 2 }
hwDataSyncNotifications OBJECT IDENTIFIER ::= { hwDataSync 3 }
hwCurrentCfgChgSeqID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the ID of the current configuration change.
The value ranges from 0 to 65535. After the ID of the configuration change reaches
the maximum value, the value of the ID starts from 1 again.
After the device is restarted, the value of the ID becomes 0."
::= { hwDataSyncScalarObjects 1 }
hwCfgChgSeqIDReveralCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the cycle count of the index of configuration change table."
::= { hwDataSyncScalarObjects 2 }
hwCfgChgTableMaxItem OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the maximum number of entries in hwCfgChgTable. "
::= { hwDataSyncScalarObjects 3 }
hwCfgBaselineTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the time of system confiuration was baseline."
::= { hwDataSyncScalarObjects 4 }
hwCfgChgTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwCfgChgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to record configuration changes.
In this table, you can find the configuration change based on the specific index."
::= { hwDataSyncTableObjects 1 }
hwCfgChgEntry OBJECT-TYPE
SYNTAX HwCfgChgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry of hwCfgChgTable."
INDEX { hwCfgChgSeqID }
::= { hwCfgChgTable 1 }
HwCfgChgEntry::=
SEQUENCE {
hwCfgChgSeqID
Integer32,
hwCfgChgTime
DateAndTime,
hwCfgChgTerminalType
INTEGER,
hwCfgChgTerminalID
Integer32,
hwCfgChgType
INTEGER,
hwCfgChgViewName
OCTET STRING,
hwCfgChgCmdID
Integer32,
hwCfgChgDetailInfo
OCTET STRING
}
hwCfgChgSeqID OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the configuration change ID.
When configuration is changed, the sequence id will plus 1."
::= { hwCfgChgEntry 1 }
hwCfgChgTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the configuration change time."
::= { hwCfgChgEntry 2 }
hwCfgChgTerminalType OBJECT-TYPE
SYNTAX INTEGER {snmp(1),telnet(2),netconf(3)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the type of the terminal."
::= { hwCfgChgEntry 3 }
hwCfgChgTerminalID OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the terminal ID."
::= { hwCfgChgEntry 4 }
hwCfgChgType OBJECT-TYPE
SYNTAX INTEGER {create(1),modify(2),delete(3)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the configuration change type."
::= { hwCfgChgEntry 5 }
hwCfgChgViewName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the name of the view in which the configuration change occurs.
For the command operation, the object is the name of the view in which the command is run.
For the SNMP operation, the object is the OID of the MIB table or the scalar object."
::= { hwCfgChgEntry 6 }
hwCfgChgCmdID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the ID of the configuration change command.
For the SNMP operation, the value is 0."
::= { hwCfgChgEntry 7 }
hwCfgChgDetailInfo OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates detailed configuration change information.
For the command operation, the object is the command line.
For the SNMP operation, the object is the index of the MIB table.
When there are multiple indexes, the format of index1.index2.index3 is adopted."
::= { hwCfgChgEntry 8 }
hwCollectTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwCollectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to enable the NMS to send the collecting script to the device to trigger the collection,
and then monitor the collection status."
::= { hwDataSyncTableObjects 2 }
hwCollectEntry OBJECT-TYPE
SYNTAX HwCollectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry of hwCollectTable."
INDEX { hwCollectIndex }
::= { hwCollectTable 1 }
HwCollectEntry ::=
SEQUENCE {
hwCollectIndex
Integer32,
hwCollectNetManageId
Integer32,
hwCollectOperation
INTEGER,
hwCollectInScriptFile
OCTET STRING,
hwCollectInResultFile
OCTET STRING,
hwCollectState
INTEGER,
hwCollectRowStatus
RowStatus
}
hwCollectIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object identifies the collection index."
::= { hwCollectEntry 1 }
hwCollectNetManageId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the NMS ID."
::= { hwCollectEntry 2 }
hwCollectOperation OBJECT-TYPE
SYNTAX INTEGER {begin(1),stop(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the instruction for the collection operation.
Default value is stop."
::= { hwCollectEntry 3 }
hwCollectInScriptFile OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the name of the script file. T
he length of the file name ranges from 1 character to 255 characters."
::= { hwCollectEntry 4 }
hwCollectInResultFile OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the name of the result file.
The length of the file name ranges from 1 character to 255 characters."
::= { hwCollectEntry 5 }
hwCollectState OBJECT-TYPE
SYNTAX INTEGER {idle(1),collecting(2)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the collection status."
::= { hwCollectEntry 6 }
hwCollectRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the row status."
::= { hwCollectEntry 7 }
hwCfgChgNotify NOTIFICATION-TYPE
OBJECTS {hwCurrentCfgChgSeqID, hwCfgChgSeqIDReveralCount, hwCfgChgTableMaxItem, hwCfgBaselineTime}
STATUS current
DESCRIPTION
"This trap is generated when a configuration change occurs
on the device within a specified period."
::= { hwDataSyncNotifications 1 }
END
--