compass-core/mibs/DISMAN-PING-MIB.mib

1612 lines
64 KiB
Plaintext

-- ===========================================================================
-- Copyright (C) . All rights reserved.
--
-- Description: REMOPS MIB
-- Reference: Module(DISMAN-PING-MIB) Extracted from RFC4560.TXT,from 29055 to 97234.Obsoletes: 2925
-- Version: V1.00
-- History:
--
-- ===========================================================================
DISMAN-PING-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32,
Unsigned32, Gauge32, mib-2,
NOTIFICATION-TYPE, OBJECT-IDENTITY
FROM SNMPv2-SMI -- RFC2578
TEXTUAL-CONVENTION, RowStatus,
StorageType, DateAndTime, TruthValue
FROM SNMPv2-TC -- RFC2579
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF -- RFC2580
InterfaceIndexOrZero -- RFC2863
FROM IF-MIB
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB -- RFC3411
InetAddressType, InetAddress
FROM INET-ADDRESS-MIB; -- RFC4001
pingMIB MODULE-IDENTITY
LAST-UPDATED "200606130000Z" -- 13 June 2006
ORGANIZATION "IETF Distributed Management Working Group"
CONTACT-INFO
"Juergen Quittek
NEC Europe Ltd.
Network Laboratories
Kurfuersten-Anlage 36
69115 Heidelberg
Germany
Phone: +49 6221 4342-115
Email: quittek@netlab.nec.de"
DESCRIPTION
"The Ping MIB (DISMAN-PING-MIB) provides the capability of
controlling the use of the ping function at a remote
host.
Copyright (C) The Internet Society (2006). This version of
this MIB module is part of RFC 4560; see the RFC itself for
full legal notices."
-- Revision history
REVISION "200606130000Z" -- 13 June 2006
DESCRIPTION
"Updated version, published as RFC 4560.
- Correctly considered IPv6 in DESCRIPTION
clause of pingCtlDataSize
- Replaced references to RFC 2575 by RFC 3415
- Replaced references to RFC 2571 by RFC 3411
- Replaced references to RFC 2851 by RFC 4001
- Added DEFVAL { {} } to definition of
pingCtlTrapGeneration
- Changed DEFVAL of object pingCtlDescr from
DEFVAL { '00'H } to DEFVAL { ''H }
- Changed DEFVAL of object pingCtlSourceAddressType
from DEFVAL { ipv4 } to DEFVAL { unknown }
- Extended DESCRIPTION clause of pingResultsTable
describing re-initialization of entries
- Changed SYNTAX of pingResultsProbeResponses and
pingResultsSentProbes from Unsigned32 to Gauge32
- Changed status of pingCompliance to deprecated
- Added pingFullCompliance and pingMinimumCompliance
- Changed status of pingGroup and pingTimeStampGroup
to deprecated
- Added pingMinimumGroup, pingCtlRowStatusGroup,
and pingHistoryGroup"
REVISION "200009210000Z" -- 21 September 2000
DESCRIPTION
"Initial version, published as RFC 2925."
::= { mib-2 80 }
-- Textual Conventions
OperationResponseStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Used to report the result of an operation:
responseReceived(1) - Operation is completed successfully.
unknown(2) - Operation failed due to unknown error.
internalError(3) - An implementation detected an error
in its own processing that caused an operation
to fail.
requestTimedOut(4) - Operation failed to receive a
valid reply within the time limit imposed on it.
unknownDestinationAddress(5) - Invalid destination
address.
noRouteToTarget(6) - Could not find a route to target.
interfaceInactiveToTarget(7) - The interface to be
used in sending a probe is inactive, and an
alternate route does not exist.
arpFailure(8) - Unable to resolve a target address to a
media-specific address.
maxConcurrentLimitReached(9) - The maximum number of
concurrent active operations would have been exceeded
if the corresponding operation was allowed.
unableToResolveDnsName(10) - The DNS name specified was
unable to be mapped to an IP address.
invalidHostAddress(11) - The IP address for a host
has been determined to be invalid. Examples of this
are broadcast or multicast addresses."
SYNTAX INTEGER {
responseReceived(1),
unknown(2),
internalError(3),
requestTimedOut(4),
unknownDestinationAddress(5),
noRouteToTarget(6),
interfaceInactiveToTarget(7),
arpFailure(8),
maxConcurrentLimitReached(9),
unableToResolveDnsName(10),
invalidHostAddress(11)
}
-- Top level structure of the MIB
pingNotifications OBJECT IDENTIFIER ::= { pingMIB 0 }
pingObjects OBJECT IDENTIFIER ::= { pingMIB 1 }
pingConformance OBJECT IDENTIFIER ::= { pingMIB 2 }
-- The registration node (point) for ping implementation types
pingImplementationTypeDomains OBJECT IDENTIFIER ::= { pingMIB 3 }
pingIcmpEcho OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indicates that an implementation is using the Internet
Control Message Protocol (ICMP) 'ECHO' facility."
::= { pingImplementationTypeDomains 1 }
pingUdpEcho OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indicates that an implementation is using the UDP echo
port (7)."
REFERENCE
"RFC 862, 'Echo Protocol'."
::= { pingImplementationTypeDomains 2 }
pingSnmpQuery OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indicates that an implementation is using an SNMP query
to calculate a round trip time."
::= { pingImplementationTypeDomains 3 }
pingTcpConnectionAttempt OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Indicates that an implementation is attempting to
connect to a TCP port in order to calculate a round
trip time."
::= { pingImplementationTypeDomains 4 }
-- Simple Object Definitions
pingMaxConcurrentRequests OBJECT-TYPE
SYNTAX Unsigned32
UNITS "requests"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of concurrent active ping requests
that are allowed within an agent implementation. A value
of 0 for this object implies that there is no limit for
the number of concurrent active requests in effect.
The limit applies only to new requests being activated.
When a new value is set, the agent will continue processing
all the requests already active, even if their number
exceeds the limit just imposed."
DEFVAL { 10 }
::= { pingObjects 1 }
-- Ping Control Table
pingCtlTable OBJECT-TYPE
SYNTAX SEQUENCE OF PingCtlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the ping Control Table for providing, via SNMP,
the capability of performing ping operations at
a remote host. The results of these operations are
stored in the pingResultsTable and the
pingProbeHistoryTable."
::= { pingObjects 2 }
pingCtlEntry OBJECT-TYPE
SYNTAX PingCtlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the pingCtlTable. The first index
element, pingCtlOwnerIndex, is of type SnmpAdminString,
a textual convention that allows for use of the SNMPv3
View-Based Access Control Model (RFC 3415, VACM)
and that allows a management application to identify its
entries. The second index, pingCtlTestName (also an
SnmpAdminString), enables the same management
application to have multiple outstanding requests."
INDEX {
pingCtlOwnerIndex,
pingCtlTestName
}
::= { pingCtlTable 1 }
PingCtlEntry ::=
SEQUENCE {
pingCtlOwnerIndex SnmpAdminString,
pingCtlTestName SnmpAdminString,
pingCtlTargetAddressType InetAddressType,
pingCtlTargetAddress InetAddress,
pingCtlDataSize Unsigned32,
pingCtlTimeOut Unsigned32,
pingCtlProbeCount Unsigned32,
pingCtlAdminStatus INTEGER,
pingCtlDataFill OCTET STRING,
pingCtlFrequency Unsigned32,
pingCtlMaxRows Unsigned32,
pingCtlStorageType StorageType,
pingCtlTrapGeneration BITS,
pingCtlTrapProbeFailureFilter Unsigned32,
pingCtlTrapTestFailureFilter Unsigned32,
pingCtlType OBJECT IDENTIFIER,
pingCtlDescr SnmpAdminString,
pingCtlSourceAddressType InetAddressType,
pingCtlSourceAddress InetAddress,
pingCtlIfIndex InterfaceIndexOrZero,
pingCtlByPassRouteTable TruthValue,
pingCtlDSField Unsigned32,
pingCtlRowStatus RowStatus
}
pingCtlOwnerIndex OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"To facilitate the provisioning of access control by a
security administrator using the View-Based Access
Control Model (RFC 2575, VACM) for tables in which
multiple users may need to create or
modify entries independently, the initial index is used
as an 'owner index'. Such an initial index has a syntax
of SnmpAdminString and can thus be trivially mapped to a
securityName or groupName defined in VACM, in
accordance with a security policy.
When used in conjunction with such a security policy, all
entries in the table belonging to a particular user (or
group) will have the same value for this initial index.
For a given user's entries in a particular table, the
object identifiers for the information in these entries
will have the same subidentifiers (except for the 'column'
subidentifier) up to the end of the encoded owner index.
To configure VACM to permit access to this portion of the
table, one would create vacmViewTreeFamilyTable entries
with the value of vacmViewTreeFamilySubtree including
the owner index portion, and vacmViewTreeFamilyMask
'wildcarding' the column subidentifier. More elaborate
configurations are possible."
::= { pingCtlEntry 1 }
pingCtlTestName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The name of the ping test. This is locally unique, within
the scope of a pingCtlOwnerIndex."
::= { pingCtlEntry 2 }
pingCtlTargetAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the type of host address to be used at a remote
host for performing a ping operation."
DEFVAL { unknown }
::= { pingCtlEntry 3 }
pingCtlTargetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the host address to be used at a remote host for
performing a ping operation. The host address type is
determined by the value of the corresponding
pingCtlTargetAddressType.
A value for this object MUST be set prior to transitioning
its corresponding pingCtlEntry to active(1) via
pingCtlRowStatus."
DEFVAL { ''H }
::= { pingCtlEntry 4 }
pingCtlDataSize OBJECT-TYPE
SYNTAX Unsigned32 (0..65507)
UNITS "octets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the size of the data portion to be
transmitted in a ping operation, in octets. Whether this
value can be applied depends on the selected
implementation method for performing a ping operation,
indicated by pingCtlType in the same conceptual row.
If the method used allows applying the value contained
in this object, then it MUST be applied. If the specified
size is not appropriate for the chosen ping method, the
implementation SHOULD use whatever size (appropriate to
the method) is closest to the specified size.
The maximum value for this object was computed by
subtracting the smallest possible IP header size of
20 octets (IPv4 header with no options) and the UDP
header size of 8 octets from the maximum IP packet size.
An IP packet has a maximum size of 65535 octets
(excluding IPv6 Jumbograms)."
DEFVAL { 0 }
::= { pingCtlEntry 5 }
pingCtlTimeOut OBJECT-TYPE
SYNTAX Unsigned32 (1..60)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the time-out value, in seconds, for a
remote ping operation."
DEFVAL { 3 }
::= { pingCtlEntry 6 }
pingCtlProbeCount OBJECT-TYPE
SYNTAX Unsigned32 (1..15)
UNITS "probes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the number of times to perform a ping
operation at a remote host as part of a single ping test."
DEFVAL { 1 }
::= { pingCtlEntry 7 }
pingCtlAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1), -- test should be started
disabled(2) -- test should be stopped
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Reflects the desired state that a pingCtlEntry should be
in:
enabled(1) - Attempt to activate the test as defined by
this pingCtlEntry.
disabled(2) - Deactivate the test as defined by this
pingCtlEntry.
Refer to the corresponding pingResultsOperStatus to
determine the operational state of the test defined by
this entry."
DEFVAL { disabled }
::= { pingCtlEntry 8 }
pingCtlDataFill OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..1024))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The content of this object is used together with the
corresponding pingCtlDataSize value to determine how to
fill the data portion of a probe packet. The option of
selecting a data fill pattern can be useful when links
are compressed or have data pattern sensitivities. The
contents of pingCtlDataFill should be repeated in a ping
packet when the size of the data portion of the ping
packet is greater than the size of pingCtlDataFill."
DEFVAL { '00'H }
::= { pingCtlEntry 9 }
pingCtlFrequency OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of seconds to wait before repeating a ping test
as defined by the value of the various objects in the
corresponding row.
A single ping test consists of a series of ping probes.
The number of probes is determined by the value of the
corresponding pingCtlProbeCount object. After a single
test is completed the number of seconds as defined by the
value of pingCtlFrequency MUST elapse before the
next ping test is started.
A value of 0 for this object implies that the test
as defined by the corresponding entry will not be
repeated."
DEFVAL { 0 }
::= { pingCtlEntry 10 }
pingCtlMaxRows OBJECT-TYPE
SYNTAX Unsigned32
UNITS "rows"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of corresponding entries allowed
in the pingProbeHistoryTable. An implementation of this
MIB will remove the oldest corresponding entry in the
pingProbeHistoryTable to allow the addition of an
new entry once the number of corresponding rows in the
pingProbeHistoryTable reaches this value.
Old entries are not removed when a new test is
started. Entries are added to the pingProbeHistoryTable
until pingCtlMaxRows is reached before entries begin to
be removed.
A value of 0 for this object disables creation of
pingProbeHistoryTable entries."
DEFVAL { 50 }
::= { pingCtlEntry 11 }
pingCtlStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The storage type for this conceptual row.
Conceptual rows having the value 'permanent' need not
allow write-access to any columnar objects in the row."
DEFVAL { nonVolatile }
::= { pingCtlEntry 12 }
pingCtlTrapGeneration OBJECT-TYPE
SYNTAX BITS {
probeFailure(0),
testFailure(1),
testCompletion(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object determines when and whether
to generate a notification for this entry:
probeFailure(0) - Generate a pingProbeFailed
notification subject to the value of
pingCtlTrapProbeFailureFilter. The object
pingCtlTrapProbeFailureFilter can be used
to specify the number of consecutive probe
failures that are required before a
pingProbeFailed notification can be generated.
testFailure(1) - Generate a pingTestFailed
notification. In this instance the object
pingCtlTrapTestFailureFilter can be used to
determine the number of probe failures that
signal when a test fails.
testCompletion(2) - Generate a pingTestCompleted
notification.
By default, no bits are set, indicating that
none of the above options is selected."
DEFVAL { {} } -- no bits set.
::= { pingCtlEntry 13 }
pingCtlTrapProbeFailureFilter OBJECT-TYPE
SYNTAX Unsigned32 (0..15)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is used to determine when
to generate a pingProbeFailed NOTIFICATION.
Setting BIT probeFailure(0) of object
pingCtlTrapGeneration to '1' implies that a
pingProbeFailed NOTIFICATION is generated only when
a number of consecutive ping probes equal to the
value of pingCtlTrapProbeFailureFilter fail within
a given ping test. After triggering the notification,
the probe failure counter is reset to zero."
DEFVAL { 1 }
::= { pingCtlEntry 14 }
pingCtlTrapTestFailureFilter OBJECT-TYPE
SYNTAX Unsigned32 (0..15)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is used to determine when
to generate a pingTestFailed NOTIFICATION.
Setting BIT testFailure(1) of object
pingCtlTrapGeneration to '1' implies that a
pingTestFailed NOTIFICATION is generated only when
a number of consecutive ping tests equal to the
value of pingCtlTrapProbeFailureFilter fail.
After triggering the notification, the test failure
counter is reset to zero."
DEFVAL { 1 }
::= { pingCtlEntry 15 }
pingCtlType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is used either to report or
to select the implementation method to be used for
calculating a ping response time. The value of this
object MAY be selected from pingImplementationTypeDomains.
Additional implementation types SHOULD be allocated as
required by implementers of the DISMAN-PING-MIB under
their enterprise-specific registration point and not
beneath pingImplementationTypeDomains."
DEFVAL { pingIcmpEcho }
::= { pingCtlEntry 16 }
pingCtlDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The purpose of this object is to provide a
descriptive name of the remote ping test."
DEFVAL { ''H }
::= { pingCtlEntry 17 }
pingCtlSourceAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the type of the source address,
pingCtlSourceAddress, to be used at a remote host
when a ping operation is performed."
DEFVAL { unknown }
::= { pingCtlEntry 18 }
pingCtlSourceAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Use the specified IP address (which must be given in
numeric form, not as a hostname) as the source address
in outgoing probe packets. On hosts with more than one
IP address, this option can be used to select the address
to be used. If the IP address is not one of this
machine's interface addresses, an error is returned and
nothing is sent. A zero-length octet string value for
this object disables source address specification.
The address type (InetAddressType) that relates to
this object is specified by the corresponding value
of pingCtlSourceAddressType."
DEFVAL { ''H }
::= { pingCtlEntry 19 }
pingCtlIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Setting this object to an interface's ifIndex prior
to starting a remote ping operation directs
the ping probes to be transmitted over the
specified interface. A value of zero for this object
means that this option is not enabled."
DEFVAL { 0 }
::= { pingCtlEntry 20 }
pingCtlByPassRouteTable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The purpose of this object is to enable optional
bypassing the route table. If enabled, the remote
host will bypass the normal routing tables and send
directly to a host on an attached network. If the
host is not on a directly attached network, an
error is returned. This option can be used to perform
the ping operation to a local host through an
interface that has no route defined (e.g., after the
interface was dropped by the routing daemon at the host)."
DEFVAL { false }
::= { pingCtlEntry 21 }
pingCtlDSField OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the value to store in the Type of Service
(TOS) octet in the IPv4 header or in the Traffic
Class octet in the IPv6 header, respectively, of the
IP packet used to encapsulate the ping probe.
The octet to be set in the IP header contains the
Differentiated Services (DS) Field in the six most
significant bits.
This option can be used to determine what effect an
explicit DS Field setting has on a ping response.
Not all values are legal or meaningful. A value of 0
means that the function represented by this option is
not supported. DS Field usage is often not supported
by IP implementations, and not all values are supported.
Refer to RFC 2474 and RFC 3260 for guidance on usage of
this field."
REFERENCE
"Refer to RFC 1812 for the definition of the IPv4 TOS
octet and to RFC 2460 for the definition of the IPv6
Traffic Class octet. Refer to RFC 2474 and RFC 3260
for the definition of the Differentiated Services Field."
DEFVAL { 0 }
::= { pingCtlEntry 22 }
pingCtlRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows entries to be created and deleted
in the pingCtlTable. Deletion of an entry in this
table results in the deletion of all corresponding (same
pingCtlOwnerIndex and pingCtlTestName index values)
pingResultsTable and pingProbeHistoryTable entries.
A value MUST be specified for pingCtlTargetAddress
prior to acceptance of a transition to active(1) state.
When a value for pingCtlTargetAddress is set,
the value of object pingCtlRowStatus changes
from notReady(3) to notInService(2).
Activation of a remote ping operation is controlled
via pingCtlAdminStatus, not by changing
this object's value to active(1).
Transitions in and out of active(1) state are not
allowed while an entry's pingResultsOperStatus is
active(1), with the exception that deletion of
an entry in this table by setting its RowStatus
object to destroy(6) will stop an active
ping operation.
The operational state of a ping operation
can be determined by examination of its
pingResultsOperStatus object."
REFERENCE
"See definition of RowStatus in RFC 2579, 'Textual
Conventions for SMIv2.'"
::= { pingCtlEntry 23 }
-- Ping Results Table
pingResultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PingResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the Ping Results Table for providing
the capability of performing ping operations at
a remote host. The results of these operations are
stored in the pingResultsTable and the pingProbeHistoryTable.
An entry is added to the pingResultsTable when an
pingCtlEntry is started by successful transition
of its pingCtlAdminStatus object to enabled(1).
If the object pingCtlAdminStatus already has the value
enabled(1), and if the corresponding pingResultsOperStatus
object has the value completed(3), then successfully writing
enabled(1) to object pingCtlAdminStatus re-initializes the
already existing entry in the pingResultsTable. The values
of objects in the re-initialized entry are the same as the
values of objects in a new entry would be.
An entry is removed from the pingResultsTable when
its corresponding pingCtlEntry is deleted."
::= { pingObjects 3 }
pingResultsEntry OBJECT-TYPE
SYNTAX PingResultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the pingResultsTable. The
pingResultsTable has the same indexing as the
pingCtlTable so that a pingResultsEntry
corresponds to the pingCtlEntry that caused it to
be created."
INDEX {
pingCtlOwnerIndex,
pingCtlTestName
}
::= { pingResultsTable 1 }
PingResultsEntry ::=
SEQUENCE {
pingResultsOperStatus INTEGER,
pingResultsIpTargetAddressType InetAddressType,
pingResultsIpTargetAddress InetAddress,
pingResultsMinRtt Unsigned32,
pingResultsMaxRtt Unsigned32,
pingResultsAverageRtt Unsigned32,
pingResultsProbeResponses Gauge32,
pingResultsSentProbes Gauge32,
pingResultsRttSumOfSquares Unsigned32,
pingResultsLastGoodProbe DateAndTime
}
pingResultsOperStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1), -- test is in progress
disabled(2), -- test has stopped
completed(3) -- test is completed
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reflects the operational state of a pingCtlEntry:
enabled(1) - Test is active.
disabled(2) - Test has stopped.
completed(3) - Test is completed."
::= { pingResultsEntry 1 }
pingResultsIpTargetAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the type of address stored
in the corresponding pingResultsIpTargetAddress
object."
DEFVAL { unknown }
::= { pingResultsEntry 2 }
pingResultsIpTargetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports the IP address associated
with a pingCtlTargetAddress value when the destination
address is specified as a DNS name. The value of
this object should be a zero-length octet string
when a DNS name is not specified or when a
specified DNS name fails to resolve.
The address type (InetAddressType) that relates to
this object is specified by the corresponding value
of pingResultsIpTargetAddressType."
DEFVAL { ''H }
::= { pingResultsEntry 3 }
pingResultsMinRtt OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum ping round-trip-time (RTT) received. A value
of 0 for this object implies that no RTT has been received."
::= { pingResultsEntry 4 }
pingResultsMaxRtt OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum ping round-trip-time (RTT) received. A value
of 0 for this object implies that no RTT has been received."
::= { pingResultsEntry 5 }
pingResultsAverageRtt OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current average ping round-trip-time (RTT)."
::= { pingResultsEntry 6 }
pingResultsProbeResponses OBJECT-TYPE
SYNTAX Gauge32
UNITS "responses"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of responses received for the corresponding
pingCtlEntry and pingResultsEntry. The value of this object
MUST be reported as 0 when no probe responses have been
received."
::= { pingResultsEntry 7 }
pingResultsSentProbes OBJECT-TYPE
SYNTAX Gauge32
UNITS "probes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object reflects the number of probes sent
for the corresponding pingCtlEntry and pingResultsEntry.
The value of this object MUST be reported as 0 when no probes
have been sent."
::= { pingResultsEntry 8 }
pingResultsRttSumOfSquares OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the sum of the squares for all ping
responses received. Its purpose is to enable standard
deviation calculation. The value of this object MUST
be reported as 0 when no ping responses have been
received."
::= { pingResultsEntry 9 }
pingResultsLastGoodProbe OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Date and time when the last response was received for
a probe."
::= { pingResultsEntry 10 }
-- Ping Probe History Table
pingProbeHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF PingProbeHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines a table for storing the results of ping
operations. The number of entries in this table is
limited per entry in the pingCtlTable by the value
of the corresponding pingCtlMaxRows object.
An entry in this table is created when the result of
a ping probe is determined. The initial 2 instance
identifier index values identify the pingCtlEntry
that a probe result (pingProbeHistoryEntry) belongs
to. An entry is removed from this table when
its corresponding pingCtlEntry is deleted.
An implementation of this MIB will remove the oldest
entry in the pingProbeHistoryTable of the
corresponding entry in the pingCtlTable to allow
the addition of an new entry once the number of rows
in the pingProbeHistoryTable reaches the value
specified by pingCtlMaxRows for the corresponding
entry in the pingCtlTable."
::= { pingObjects 4 }
pingProbeHistoryEntry OBJECT-TYPE
SYNTAX PingProbeHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines an entry in the pingProbeHistoryTable.
The first two index elements identify the
pingCtlEntry that a pingProbeHistoryEntry belongs
to. The third index element selects a single
probe result."
INDEX {
pingCtlOwnerIndex,
pingCtlTestName,
pingProbeHistoryIndex
}
::= { pingProbeHistoryTable 1 }
PingProbeHistoryEntry ::=
SEQUENCE {
pingProbeHistoryIndex Unsigned32,
pingProbeHistoryResponse Unsigned32,
pingProbeHistoryStatus OperationResponseStatus,
pingProbeHistoryLastRC Integer32,
pingProbeHistoryTime DateAndTime
}
pingProbeHistoryIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..'ffffffff'h)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table is created when the result of
a ping probe is determined. The initial 2 instance
identifier index values identify the pingCtlEntry
that a probe result (pingProbeHistoryEntry) belongs
to.
An implementation MUST start assigning
pingProbeHistoryIndex values at 1 and wrap after
exceeding the maximum possible value as defined by
the limit of this object ('ffffffff'h)."
::= { pingProbeHistoryEntry 1 }
pingProbeHistoryResponse OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time measured in milliseconds from when
a probe was sent to when its response was received or
when it timed out. The value of this object is reported
as 0 when it is not possible to transmit a probe."
::= { pingProbeHistoryEntry 2 }
pingProbeHistoryStatus OBJECT-TYPE
SYNTAX OperationResponseStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The result of a particular probe done by a remote host."
::= { pingProbeHistoryEntry 3 }
pingProbeHistoryLastRC OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last implementation-method-specific reply code received.
If the ICMP Echo capability is being used, then a successful
probe ends when an ICMP response is received that contains
the code ICMP_ECHOREPLY(0). The ICMP codes are maintained
by IANA. Standardized ICMP codes are listed at
http://www.iana.org/assignments/icmp-parameters.
The ICMPv6 codes are listed at
http://www.iana.org/assignments/icmpv6-parameters."
::= { pingProbeHistoryEntry 4 }
pingProbeHistoryTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp for when this probe result was determined."
::= { pingProbeHistoryEntry 5 }
-- Notification Definition section
pingProbeFailed NOTIFICATION-TYPE
OBJECTS {
pingCtlTargetAddressType,
pingCtlTargetAddress,
pingResultsOperStatus,
pingResultsIpTargetAddressType,
pingResultsIpTargetAddress,
pingResultsMinRtt,
pingResultsMaxRtt,
pingResultsAverageRtt,
pingResultsProbeResponses,
pingResultsSentProbes,
pingResultsRttSumOfSquares,
pingResultsLastGoodProbe
}
STATUS current
DESCRIPTION
"Generated when a probe failure is detected, when the
corresponding pingCtlTrapGeneration object is set to
probeFailure(0), subject to the value of
pingCtlTrapProbeFailureFilter. The object
pingCtlTrapProbeFailureFilter can be used to specify the
number of consecutive probe failures that are required
before this notification can be generated."
::= { pingNotifications 1 }
pingTestFailed NOTIFICATION-TYPE
OBJECTS {
pingCtlTargetAddressType,
pingCtlTargetAddress,
pingResultsOperStatus,
pingResultsIpTargetAddressType,
pingResultsIpTargetAddress,
pingResultsMinRtt,
pingResultsMaxRtt,
pingResultsAverageRtt,
pingResultsProbeResponses,
pingResultsSentProbes,
pingResultsRttSumOfSquares,
pingResultsLastGoodProbe
}
STATUS current
DESCRIPTION
"Generated when a ping test is determined to have failed,
when the corresponding pingCtlTrapGeneration object is
set to testFailure(1). In this instance,
pingCtlTrapTestFailureFilter should specify the number of
probes in a test required to have failed in order to
consider the test failed."
::= { pingNotifications 2 }
pingTestCompleted NOTIFICATION-TYPE
OBJECTS {
pingCtlTargetAddressType,
pingCtlTargetAddress,
pingResultsOperStatus,
pingResultsIpTargetAddressType,
pingResultsIpTargetAddress,
pingResultsMinRtt,
pingResultsMaxRtt,
pingResultsAverageRtt,
pingResultsProbeResponses,
pingResultsSentProbes,
pingResultsRttSumOfSquares,
pingResultsLastGoodProbe
}
STATUS current
DESCRIPTION
"Generated at the completion of a ping test when the
corresponding pingCtlTrapGeneration object has the
testCompletion(2) bit set."
::= { pingNotifications 3 }
-- Conformance information
-- Compliance statements
pingCompliances OBJECT IDENTIFIER ::= { pingConformance 1 }
pingGroups OBJECT IDENTIFIER ::= { pingConformance 2 }
-- Compliance statements
pingFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities that
fully implement the DISMAN-PING-MIB."
MODULE -- this module
MANDATORY-GROUPS {
pingMinimumGroup,
pingCtlRowStatusGroup,
pingHistoryGroup,
pingNotificationsGroup
}
OBJECT pingMaxConcurrentRequests
MIN-ACCESS read-only
DESCRIPTION
"The agent is not required to support set
operations to this object."
OBJECT pingCtlStorageType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT pingCtlType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. In addition, the only
value that MUST be supported by an implementation is
pingIcmpEcho."
OBJECT pingCtlSourceAddressType
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
MIN-ACCESS read-only
DESCRIPTION
"Write access to this object is not required by
implementations that are not capable of binding the
send socket with a source address. An implementation
is only required to support IPv4 and IPv6 addresses."
OBJECT pingCtlSourceAddress
SYNTAX InetAddress (SIZE(0|4|16))
MIN-ACCESS read-only
DESCRIPTION
"Write access to this object is not required by
implementations that are not capable of binding the
send socket with a source address. An implementation
is only required to support IPv4 and IPv6 addresses."
OBJECT pingCtlIfIndex
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. If write access is
not supported, return a 0 as the value of this object.
A value of 0 means that the function represented by
this option is not supported."
OBJECT pingCtlByPassRouteTable
MIN-ACCESS read-only
DESCRIPTION
"Write access to this object is not required by
implementations that are not capable of its
implementation. The function represented by this
object is implementable if the setsockopt
SOL_SOCKET SO_DONTROUTE option is supported."
OBJECT pingCtlDSField
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. If write access is
not supported, return a 0 as the value of this object.
A value of 0 means that the function represented by
this option is not supported."
OBJECT pingResultsIpTargetAddressType
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
DESCRIPTION
"An implementation is only required to
support IPv4 and IPv6 addresses."
OBJECT pingResultsIpTargetAddress
SYNTAX InetAddress (SIZE(0|4|16))
DESCRIPTION
"An implementation is only required to
support IPv4 and globally unique IPv6 addresses."
OBJECT pingResultsLastGoodProbe
DESCRIPTION
"This object is mandatory for implementations that have
access to a system clock and that are capable of setting
the values for DateAndTime objects. It is RECOMMENDED
that when this object is not supported its values
be reported as '0000000000000000'H."
OBJECT pingProbeHistoryTime
DESCRIPTION
"This object is mandatory for implementations that have
access to a system clock and that are capable of setting
the values for DateAndTime objects. It is RECOMMENDED
that when this object is not supported its values
be reported as '0000000000000000'H."
::= { pingCompliances 2 }
pingMinimumCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The minimum compliance statement for SNMP entities
that implement the minimal subset of the
DISMAN-PING-MIB. Implementors might choose this
subset for small devices with limited resources."
MODULE -- this module
MANDATORY-GROUPS { pingMinimumGroup }
GROUP pingCtlRowStatusGroup
DESCRIPTION
"A compliant implementation does not have to implement
the pingCtlRowStatusGroup."
GROUP pingHistoryGroup
DESCRIPTION
"A compliant implementation does not have to implement
the pingHistoryGroup."
GROUP pingNotificationsGroup
DESCRIPTION
"A compliant implementation does not have to implement
the pingNotificationsGroup."
OBJECT pingMaxConcurrentRequests
MIN-ACCESS read-only
DESCRIPTION
"The agent is not required to support set
operations to this object."
OBJECT pingCtlDataFill
MIN-ACCESS read-only
DESCRIPTION
"The agent is not required to support set
operations to this object."
OBJECT pingCtlFrequency
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. If write access is
not supported, return a 0 as the value of this object.
A value of 0 means that the function represented by
this option is not supported."
OBJECT pingCtlMaxRows
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. If the
pingHistoryGroup is not implemented, then write
access to this object MUST be disabled, and the object
MUST return a value of 0 when retrieved."
OBJECT pingCtlStorageType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT pingCtlTrapGeneration
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. If the
pingNotificationsGroup is not implemented, then write
access to this object MUST be disabled, and the object
MUST return a value with no bit set when retrieved.
No bit set indicates that not notification is
generated."
OBJECT pingCtlTrapProbeFailureFilter
MIN-ACCESS read-only
DESCRIPTION
"If write access to pingCtlTrapGeneration is not
supported, then write access to this object must also
not be supported. In this case, return 0 as the value
of this object."
OBJECT pingCtlTrapTestFailureFilter
MIN-ACCESS read-only
DESCRIPTION
"If write access to pingCtlTrapGeneration is not
supported, then write access to this object must also
not be supported. In this case, return 0 as the value
of this object."
OBJECT pingCtlType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. In addition, the only
value that MUST be supported by an implementation is
pingIcmpEcho."
OBJECT pingCtlDescr
MIN-ACCESS read-only
DESCRIPTION
"The agent is not required to support set
operations to this object."
OBJECT pingCtlSourceAddressType
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
MIN-ACCESS read-only
DESCRIPTION
"Write access to this object is not required by
implementations that are not capable of binding the
send socket with a source address. An implementation
is only required to support IPv4 and IPv6 addresses."
OBJECT pingCtlSourceAddress
SYNTAX InetAddress (SIZE(0|4|16))
MIN-ACCESS read-only
DESCRIPTION
"Write access to this object is not required by
implementations that are not capable of binding the
send socket with a source address. An implementation
is only required to support IPv4 and IPv6 addresses."
OBJECT pingCtlIfIndex
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. If write access is
not supported, return a 0 as the value of this object.
A value of 0 means that the function represented by
this option is not supported."
OBJECT pingCtlByPassRouteTable
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. If write access is
not supported, return false(2) as the value of this
object. A value of false(2) means that the function
represented by this option is not supported."
OBJECT pingCtlDSField
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. If write access is
not supported, return a 0 as the value of this object.
A value of 0 means that the function represented by
this option is not supported."
OBJECT pingResultsIpTargetAddressType
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
DESCRIPTION
"An implementation is only required to
support IPv4 and IPv6 addresses."
OBJECT pingResultsIpTargetAddress
SYNTAX InetAddress (SIZE(0|4|16))
DESCRIPTION
"An implementation is only required to
support IPv4 and globally unique IPv6 addresses."
OBJECT pingResultsLastGoodProbe
DESCRIPTION
"This object is mandatory for implementations that have
access to a system clock and that are capable of setting
the values for DateAndTime objects. It is RECOMMENDED
that when this object is not supported its values
be reported as '0000000000000000'H."
OBJECT pingProbeHistoryTime
DESCRIPTION
"If the pingHistoryGroup is implemented, then this
object is mandatory for implementations that have
access to a system clock and that are capable of setting
the values for DateAndTime objects. It is RECOMMENDED
that when this object is not supported its values
be reported as '0000000000000000'H."
::= { pingCompliances 3 }
pingCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for the DISMAN-PING-MIB. This
compliance statement has been deprecated because the
group pingGroup and the pingTimeStampGroup have been
split and deprecated. The pingFullCompliance statement
is semantically identical to the deprecated
pingCompliance statement."
MODULE -- this module
MANDATORY-GROUPS {
pingGroup,
pingNotificationsGroup
}
GROUP pingTimeStampGroup
DESCRIPTION
"This group is mandatory for implementations that have
access to a system clock and that are capable of setting
the values for DateAndTime objects. It is RECOMMENDED
that when this group is not supported the values
for the objects in this group be reported as
'0000000000000000'H."
OBJECT pingMaxConcurrentRequests
MIN-ACCESS read-only
DESCRIPTION
"The agent is not required to support set
operations to this object."
OBJECT pingCtlStorageType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. It is also allowed
that implementations support only the volatile
StorageType enumeration."
OBJECT pingCtlType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. In addition, the only
value that MUST be supported by an implementation is
pingIcmpEcho."
OBJECT pingCtlByPassRouteTable
MIN-ACCESS read-only
DESCRIPTION
"This object is not required by implementations that
are not capable of its implementation. The function
represented by this object is implementable if the
setsockopt SOL_SOCKET SO_DONTROUTE option is
supported."
OBJECT pingCtlSourceAddressType
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
MIN-ACCESS read-only
DESCRIPTION
"This object is not required by implementations that
are not capable of binding the send socket with a
source address. An implementation is only required to
support IPv4 and IPv6 addresses."
OBJECT pingCtlSourceAddress
SYNTAX InetAddress (SIZE(0|4|16))
MIN-ACCESS read-only
DESCRIPTION
"This object is not required by implementations that
are not capable of binding the send socket with a
source address. An implementation is only required to
support IPv4 and globally unique IPv6 addresses."
OBJECT pingCtlIfIndex
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. When write access is
not supported, return a 0 as the value of this object.
A value of 0 means that the function represented by
this option is not supported."
OBJECT pingCtlDSField
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. When write access is
not supported, return a 0 as the value of this object.
A value of 0 means that the function represented by
this option is not supported."
OBJECT pingResultsIpTargetAddressType
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
DESCRIPTION
"An implementation is only required to
support IPv4 and IPv6 addresses."
OBJECT pingResultsIpTargetAddress
SYNTAX InetAddress (SIZE(0|4|16))
DESCRIPTION
"An implementation is only required to
support IPv4 and globally unique IPv6 addresses."
::= { pingCompliances 1 }
-- MIB groupings
pingMinimumGroup OBJECT-GROUP
OBJECTS {
pingMaxConcurrentRequests,
pingCtlTargetAddressType,
pingCtlTargetAddress,
pingCtlDataSize,
pingCtlTimeOut,
pingCtlProbeCount,
pingCtlAdminStatus,
pingCtlDataFill,
pingCtlFrequency,
pingCtlMaxRows,
pingCtlStorageType,
pingCtlTrapGeneration,
pingCtlTrapProbeFailureFilter,
pingCtlTrapTestFailureFilter,
pingCtlType,
pingCtlDescr,
pingCtlByPassRouteTable,
pingCtlSourceAddressType,
pingCtlSourceAddress,
pingCtlIfIndex,
pingCtlDSField,
pingResultsOperStatus,
pingResultsIpTargetAddressType,
pingResultsIpTargetAddress,
pingResultsMinRtt,
pingResultsMaxRtt,
pingResultsAverageRtt,
pingResultsProbeResponses,
pingResultsSentProbes,
pingResultsRttSumOfSquares,
pingResultsLastGoodProbe
}
STATUS current
DESCRIPTION
"The group of objects that constitute the remote ping
capability."
::= { pingGroups 4 }
pingCtlRowStatusGroup OBJECT-GROUP
OBJECTS {
pingCtlRowStatus
}
STATUS current
DESCRIPTION
"The RowStatus object of the pingCtlTable."
::= { pingGroups 5 }
pingHistoryGroup OBJECT-GROUP
OBJECTS {
pingProbeHistoryResponse,
pingProbeHistoryStatus,
pingProbeHistoryLastRC,
pingProbeHistoryTime
}
STATUS current
DESCRIPTION
"The group of objects that constitute the history
capability."
::= { pingGroups 6 }
pingNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS {
pingProbeFailed,
pingTestFailed,
pingTestCompleted
}
STATUS current
DESCRIPTION
"The notification that are required to be supported by
implementations of this MIB."
::= { pingGroups 3 }
pingGroup OBJECT-GROUP
OBJECTS {
pingMaxConcurrentRequests,
pingCtlTargetAddressType,
pingCtlTargetAddress,
pingCtlDataSize,
pingCtlTimeOut,
pingCtlProbeCount,
pingCtlAdminStatus,
pingCtlDataFill,
pingCtlFrequency,
pingCtlMaxRows,
pingCtlStorageType,
pingCtlTrapGeneration,
pingCtlTrapProbeFailureFilter,
pingCtlTrapTestFailureFilter,
pingCtlType,
pingCtlDescr,
pingCtlByPassRouteTable,
pingCtlSourceAddressType,
pingCtlSourceAddress,
pingCtlIfIndex,
pingCtlDSField,
pingCtlRowStatus,
pingResultsOperStatus,
pingResultsIpTargetAddressType,
pingResultsIpTargetAddress,
pingResultsMinRtt,
pingResultsMaxRtt,
pingResultsAverageRtt,
pingResultsProbeResponses,
pingResultsSentProbes,
pingResultsRttSumOfSquares,
pingProbeHistoryResponse,
pingProbeHistoryStatus,
pingProbeHistoryLastRC
}
STATUS deprecated
DESCRIPTION
"The group of objects that constitute the remote ping
capability."
::= { pingGroups 1 }
pingTimeStampGroup OBJECT-GROUP
OBJECTS {
pingResultsLastGoodProbe,
pingProbeHistoryTime
}
STATUS deprecated
DESCRIPTION
"The group of DateAndTime objects."
::= { pingGroups 2 }
END
-- ===========================================================================
-- Full Copyright Statement
--
-- Copyright (C) The Internet Society (2004). This document is subject
-- to the rights, licenses and restrictions contained in BCP 78, and
-- except as set forth therein, the authors retain all their rights.
--
-- This document and the information contained herein are provided on an
-- "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
-- OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET
-- ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,
-- INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE
-- INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
-- WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- Intellectual Property
--
-- The IETF takes no position regarding the validity or scope of any
-- Intellectual Property Rights or other rights that might be claimed to
-- pertain to the implementation or use of the technology described in
-- this document or the extent to which any license under such rights
-- might or might not be available; nor does it represent that it has
-- made any independent effort to identify any such rights. Information
-- on the procedures with respect to rights in RFC documents can be
-- found in BCP 78 and BCP 79.
--
-- Copies of IPR disclosures made to the IETF Secretariat and any
-- assurances of licenses to be made available, or the result of an
-- attempt made to obtain a general license or permission for the use of
-- such proprietary rights by implementers or users of this
-- specification can be obtained from the IETF on-line IPR repository at
-- http://www.ietf.org/ipr.
--
-- The IETF invites any interested party to bring to its attention any
-- copyrights, patents or patent applications, or other proprietary
-- rights that may cover technology that may be required to implement
-- this standard. Please address the information to the IETF at ietf-
-- ipr@ietf.org.
--
-- Acknowledgement
--
-- Funding for the RFC Editor function is currently provided by the
-- Internet Society.
-- ===========================================================================