RETIRED, Fuel plugin for Mellanox support
Go to file
Hamdy Khader f6a6cb4a4e Fix VXLAN iSER Bond issue
Change-Id: Ide0763d3a44c84019e2f8aab88a15f053bd1d1bf
2016-10-05 16:19:56 +03:00
bootstrap/sync Add support for ConnectX-4 LX FW configurations 2016-06-19 18:34:46 +03:00
deployment_scripts Fix VXLAN iSER Bond issue 2016-10-05 16:19:56 +03:00
doc ConnectX-4 RST user guide manual 2016-07-04 12:46:10 +00:00
repositories Initial commit 2015-03-25 10:40:57 +02:00
scripts Dynamically set maximum number of VFs in bootstrap stage 2016-06-08 11:10:18 +00:00
specs Changing plugin version to 8.0 2016-02-04 14:02:11 +02:00
.gitignore Changing plugin version to 8.0 2016-02-04 14:02:11 +02:00
.gitreview Update .gitreview for new namespace 2015-10-17 22:24:24 +00:00
.version Changing plugin version to 8.0 2016-02-04 14:02:11 +02:00
LICENSE Initial commit 2015-03-25 10:40:57 +02:00
README.md Fix README.md with ConnectX-4 release changes 2016-07-13 13:40:11 +00:00
build.sh Changing plugin version to 8.0 2016-02-04 14:02:11 +02:00
deployment_tasks.yaml Remove link_astute_file deployment task 2016-06-19 18:43:47 +03:00
environment_config.yaml Remove VXALN checkbox from UI 2016-06-13 07:58:54 +00:00
metadata.yaml Fix Mellanox ConnectX-4 serializer with bonding 2016-09-04 12:27:00 +00:00
post_install.sh Fixed post install script output message with MAX num vfs parameter 2016-06-19 18:48:32 +03:00
pre_build_hook Fixes to SRIOV VFs unbind 2016-06-13 17:17:24 +03:00
requirements-bootstrap.txt Added bootstrap replacement support 2015-04-01 16:55:30 +03:00
uninstall.sh Enhanced create_mellanox_bootstrap script 2016-05-10 06:40:49 +00:00

README.md

Mellanox Plugin for Fuel

Mellanox plugin overview

The Mellanox Fuel plugin is a bundle of scripts, packages and metadata that will extend Fuel and add Mellanox features such as SR-IOV for networking and iSER protocol for storage. Fuel can configure Mellanox ConnectX-4 network adapters to accelerate the performance of compute and storage traffic. This implements the following performance enhancements:

  • Compute nodes network enhancements:
    • SR-IOV based networking
    • VXLAN traffic offload
  • Cinder nodes use iSER block storage as the iSCSI transport rather than the default iSCSI over TCP.

These features reduce CPU overhead, boost throughput, reduce latency, and enable network traffic to bypass the software switch layer (e.g. Open vSwitch). Mellanox Plugin integration with Mellanox NEO SDN Controller enables switch VLAN auto provisioning and port configuration for Ethernet and SM PKey auto provisioning for InfiniBand networks, over private VLAN networks.

Developer's specification

Please refer to: HowTo Install Mellanox OpenStack Plugin for Mirantis Fuel 8.0

Requirements

Requirement Version/Comment
Mirantis OpenStack compatibility 8.0

The Mellanox ConnectX-4 adapters family supports up to 100 Gb/s. To reach 100 Gb/s speed in your network with ConnectX-4 adapters, you must use Mellanox Ethernet / Infiniband switches supporting 100 Gb (e.g. SN2700 (ETH), SB7700 (IB)). The switch ports should be configured specifically to use 100 Gb speed. No additional configuration is required on the adapter side.

Mellanox plugin configuration

For detailed setup configuration of Ethernet or Infiniband networks, please refer to Mellanox plugin configuration section in HowTo Install Mellanox OpenStack Plugin for Mirantis Fuel 8.0

Installation Guide

To install Mellanox plugin, follow these steps:

  1. Install Fuel Master node. For more information on how to create a Fuel Master node, please see Mirantis Fuel 8.0 documentation

  2. Download the plugin rpm file for MOS 8.0 from Fuel Plugin Catalog

  3. Copy the plugin on already installed Fuel Master. scp can be used for that:

    # scp mellanox-plugin-3.2-3.2.0-1.noarch.rpm root@<Fuel_Master_ip>:/tmp
    
  4. Install the plugin:

    # cd /tmp
    # fuel plugins --install mellanox-plugin-3.2-3.2.0-1.noarch.rpm
    
  5. Verify the plugin was installed successfully by having it listed using fuel plugins command:

    # fuel plugins
    #  id | name              | version | package_version
    #  ---|-------------------|---------|----------------
    #  1  | mellanox-plugin   | 3.2.0   | 3.0.0
    
  6. Create new bootstrap image for supporting infiniband networks create_mellanox_vpi_bootstrap can be used Example:

    [root@fuel ~]# create_mellanox_bootstrap --link_type eth --max_num_vfs 31
       Try to build image with data:
       bootstrap:
       certs: null
       container: {format: tar.gz, meta_file: metadata.yaml}
       . . .
       . . .
       . . .
       Bootstrap image f790e9f8-5bc5-4e61-9935-0640f2eed949 has been activated.
    
    [root@fuel ~]# create_mellanox_bootstrap --help
    
    usage: create_mellanox_bootstrap [-h] [--link_type {eth,ib,current}]
                                  [--max_num_vfs MAX_NUM_VFS]
    Available link_type values are:
    -------------------------------
    - eth for changing link type to Ethernet
    - ib for changing link type to Infiniband
    - current for leaving link type as is
    
    optional arguments:
      -h, --help show this help message and exit
      --link_type {eth,ib,current}
      --max_num_vfs MAX_NUM_VFS
                         an integer for the maximum number of vfs to be
                         burned in bootstrap
    
  7. In case of using the customized bootstrap image, you must reboot your target nodes with the new bootstrap image you just created. If you already have discovered nodes you can either reboot them manually or use reboot_bootstrap_nodes command. Run reboot_bootstrap_nodes -h for help.

User Guide

Please read the Mellanox Plugin User Guide.