Open Virtual Network (OVN)
==========================
Overview
--------
Open Virtual Network (OVN) can be deployed to provide networking services as
part of an OpenStack cloud.
.. note::
There are feature `gaps from ML2/OVS`_ and deploying legacy ML2/OVS with
the OpenStack Charms is still available.
OVN charms:
* neutron-api-plugin-ovn
* ovn-central
* ovn-chassis
* ovn-dedicated-chassis
.. note::
OVN is supported by Charmed OpenStack starting with OpenStack Train. OVN is
the default configuration in the `OpenStack Base bundle`_ reference
implementation.
Deployment
----------
OVN makes use of Public Key Infrastructure (PKI) to authenticate and authorize
control plane communication. The charm requires a Certificate Authority to be
present in the model as represented by the ``certificates`` relation.
Certificates must be managed by Vault.
.. note::
For Vault deployment instructions see the `vault charm`_. For certificate
management information read the `Managing TLS certificates`_ section of this
guide.
To deploy OVN:
.. code-block:: none
juju config neutron-api manage-neutron-plugin-legacy-mode=false
juju deploy neutron-api-plugin-ovn
juju deploy ovn-central -n 3 --config source=cloud:bionic-ussuri
juju deploy ovn-chassis
juju add-relation neutron-api-plugin-ovn:certificates vault:certificates
juju add-relation neutron-api-plugin-ovn:neutron-plugin \
neutron-api:neutron-plugin-api-subordinate
juju add-relation neutron-api-plugin-ovn:ovsdb-cms ovn-central:ovsdb-cms
juju add-relation ovn-central:certificates vault:certificates
juju add-relation ovn-chassis:ovsdb ovn-central:ovsdb
juju add-relation ovn-chassis:certificates vault:certificates
juju add-relation ovn-chassis:nova-compute nova-compute:neutron-plugin
The OVN components used for the data plane is deployed by the ovn-chassis
subordinate charm. A subordinate charm is deployed together with a principle
charm, nova-compute in the example above.
If you require a dedicated software gateway you may deploy the data plane
components as a principle charm through the use of the
`ovn-dedicated-chassis charm`_.
.. note::
For a concrete example take a look at the `OpenStack Base bundle`_.
High availability
-----------------
OVN is HA by design; take a look at the `OVN section of the Infrastructure high
availability`_ page.
Configuration
-------------
OVN integrates with OpenStack through the OVN ML2 driver. On OpenStack Ussuri
and onwards the OVN ML2 driver is maintained as an in-tree driver in Neutron.
On OpenStack Train it is maintained separately as per the `networking-ovn
plugin`_.
General Neutron configuration is still done through the `neutron-api charm`_,
and the subset of configuration specific to OVN is done through the
`neutron-api-plugin-ovn charm`_.
Hardware offloading support
~~~~~~~~~~~~~~~~~~~~~~~~~~~
It is possible to configure chassis to prepare network interface cards (NICs)
for use with hardware offloading and make them available to OpenStack.
.. caution::
This feature is to be considered Tech Preview. OVN has more stringent
requirements for match/action support in the hardware than for example
Neutron ML2+OVS. Make sure to acquire hardware with appropriate support.
Depending on hardware vendor, it may be required to install third party
drivers (DKMS) in order to successfully use this feature.
Hardware offload support makes use of SR-IOV as an underlying mechanism to
accelerate the data path between a virtual machine instance and the NIC
hardware. But as opposed to traditional SR-IOV support the accelerated ports
can be connected to the Open vSwitch integration bridge which allows instances
to take part in regular tenant networks. The NIC also supports hardware
offloading of tunnel encapsulation and decapsulation.
With OVN the Layer3 routing features are implemented as flow rules in Open
vSwitch. This in turn may allow Layer 3 routing to also be offloaded to NICs
with appropriate driver and firmware support.
Prerequisites
^^^^^^^^^^^^^
* Ubuntu 22.04 LTS or later
* Linux kernel >= 5.15
* Open vSwitch 2.17
* OVN 22.03
* OpenStack Yoga or later
Please refer to the `SR-IOV for networking support`_ section for information on
kernel configuration.
Charm configuration
^^^^^^^^^^^^^^^^^^^
The below example bundle excerpt will enable hardware offloading for an OVN
deployment.
.. code-block:: yaml
applications:
ovn-chassis:
charm: cs:ovn-chassis
options:
enable-hardware-offload: true
sriov-numvfs: "enp3s0f0:32 enp3s0f1:32"
neutron-api:
charm: cs:neutron-api
options:
enable-hardware-offload: true
nova-compute:
charm: cs:nova-compute
options:
pci-passthrough-whitelist: '{"address": "*:03:*", "physical_network": null}'
.. caution::
After deploying the above example the machines hosting ovn-chassis
units must be rebooted for the changes to take effect.
Boot an instance
^^^^^^^^^^^^^^^^
Now we can tell OpenStack to boot an instance and attach it to an hardware
offloaded port. This must be done in two stages, first we create a port with
``vnic-type`` 'direct' and ``binding-profile`` with 'switchdev' capabilities.
Then we create an instance connected to the newly created port:
.. code-block:: none
openstack port create --network my-network --vnic-type direct \
--binding-profile '{"capabilities": ["switchdev"]}' direct_port1
openstack server create --flavor my-flavor --key-name my-key \
--nic port-id=direct_port1 my-instance
Validate that traffic is offloaded
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
The `traffic control monitor`_ command can be used to observe updates to
filters which is one of the mechanisms used to program the NIC switch hardware.
Look for the 'in_hw' and 'not_in_hw' labels.
.. code-block:: none
sudo tc monitor
.. code-block:: console
replaced filter dev eth62 ingress protocol ip pref 3 flower chain 0 handle 0x9
dst_mac fa:16:3e:b2:20:82
src_mac fa:16:3e:b9:db:c8
eth_type ipv4
ip_proto tcp
ip_tos 67deeb90
dst_ip 10.42.0.17/28
tcp_flags 22
ip_flags nofrag
in_hw
action order 1: tunnel_key set
src_ip 0.0.0.0
dst_ip 10.6.12.8
key_id 4
dst_port 6081
csum pipe
index 15 ref 1 bind 1
action order 2: mirred (Egress Redirect to device genev_sys_6081) stolen
index 18 ref 1 bind 1
cookie d4885b4d38419f7fd7ae77a11bc78b0b
Open vSwitch has a rich set of tools to monitor traffic flows and you can use
the `data path control tools`_ to monitor offloaded flows.
.. code-block:: none
sudo ovs-appctl dpctl/dump-flows type=offloaded
.. code-block:: console
tunnel(tun_id=0x4,src=10.6.12.3,dst=10.6.12.7,tp_dst=6081,geneve({class=0x102,type=0x80,len=4,0x20007/0x7fffffff}),flags(+key)),recirc_id(0),in_port(2),eth(src=fa:16:3e:f8:52:5c,dst=00:00:00:00:00:00/01:00:00:00:00:00),eth_type(0x0800),ipv4(proto=6,frag=no),tcp_flags(psh|ack), packets:2, bytes:204, used:5.710s, actions:7
tunnel(tun_id=0x4,src=10.6.12.3,dst=10.6.12.7,tp_dst=6081,geneve({class=0x102,type=0x80,len=4,0x20007/0x7fffffff}),flags(+key)),recirc_id(0),in_port(2),eth(src=fa:16:3e:f8:52:5c,dst=00:00:00:00:00:00/01:00:00:00:00:00),eth_type(0x0800),ipv4(proto=6,frag=no),tcp_flags(ack), packets:3, bytes:230, used:5.710s, actions:7
tunnel(tun_id=0x4,src=10.6.12.8,dst=10.6.12.7,tp_dst=6081,geneve({class=0x102,type=0x80,len=4,0x60007/0x7fffffff}),flags(+key)),recirc_id(0),in_port(2),eth(src=fa:16:3e:b2:20:82,dst=00:00:00:00:00:00/01:00:00:00:00:00),eth_type(0x0800),ipv4(proto=6,frag=no),tcp_flags(syn|ack), packets:0, bytes:0, used:6.740s, actions:7
tunnel(tun_id=0x4,src=10.6.12.8,dst=10.6.12.7,tp_dst=6081,geneve({class=0x102,type=0x80,len=4,0x60007/0x7fffffff}),flags(+key)),recirc_id(0),in_port(2),eth(src=fa:16:3e:b2:20:82,dst=00:00:00:00:00:00/01:00:00:00:00:00),eth_type(0x0800),ipv4(proto=6,frag=no),tcp_flags(ack), packets:180737, bytes:9400154, used:0.000s, actions:7
recirc_id(0),in_port(6),eth(src=26:8a:07:82:a7:2f,dst=01:80:c2:00:00:0e),eth_type(0x88cc), packets:5, bytes:990, used:14.340s, actions:drop
recirc_id(0),in_port(7),eth(src=fa:16:3e:b9:db:c8,dst=fa:16:3e:b2:20:82),eth_type(0x0800),ipv4(dst=10.42.0.16/255.255.255.240,proto=6,tos=0/0x3,frag=no),tcp_flags(syn), packets:0, bytes:0, used:6.910s, actions:set(tunnel(tun_id=0x4,dst=10.6.12.8,ttl=64,tp_dst=6081,key6(bad key length 1, expected 0)(01)geneve({class=0x102,type=0x80,len=4,0x70006}),flags(key))),2
recirc_id(0),in_port(7),eth(src=fa:16:3e:b9:db:c8,dst=fa:16:3e:b2:20:82),eth_type(0x0800),ipv4(dst=10.42.0.16/255.255.255.240,proto=6,tos=0/0x3,frag=no),tcp_flags(ack), packets:935904, bytes:7504070178, used:0.590s, actions:set(tunnel(tun_id=0x4,dst=10.6.12.8,ttl=64,tp_dst=6081,key6(bad key length 1, expected 0)(01)geneve({class=0x102,type=0x80,len=4,0x70006}),flags(key))),2
recirc_id(0),in_port(7),eth(src=fa:16:3e:b9:db:c8,dst=fa:16:3e:b2:20:82),eth_type(0x0800),ipv4(dst=10.42.0.16/255.255.255.240,proto=6,tos=0/0x3,frag=no),tcp_flags(psh|ack), packets:3873, bytes:31053714, used:0.590s, actions:set(tunnel(tun_id=0x4,dst=10.6.12.8,ttl=64,tp_dst=6081,key6(bad key length 1, expected 0)(01)geneve({class=0x102,type=0x80,len=4,0x70006}),flags(key))),2
SR-IOV for networking support
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Single root I/O virtualization (SR-IOV) enables splitting a single physical
network port into multiple virtual network ports known as virtual functions
(VFs). The division is done at the PCI level which allows attaching the VF
directly to a virtual machine instance, bypassing the networking stack of the
hypervisor hosting the instance.
The main use case for this feature is to support applications with high
bandwidth requirements. For such applications the normal plumbing through the
userspace virtio driver in QEMU will consume too much resources from the host.
It is possible to configure chassis to prepare network interface cards (NICs)
for use with SR-IOV and make them available to OpenStack.
Prerequisites
^^^^^^^^^^^^^
To use the feature you need to use a NIC with support for SR-IOV.
Machines need to be pre-configured with appropriate kernel command-line
parameters. The charm does not handle this facet of configuration and it is
expected that the user configure this either manually or through the bare metal
provisioning layer (for example `MAAS`_). Example:
.. code-block:: none
intel_iommu=on iommu=pt probe_vf=0
Charm configuration
^^^^^^^^^^^^^^^^^^^
Enable SR-IOV, map physical network name 'physnet2' to the physical port named
'enp3s0f0' and create 4 virtual functions on it:
.. code-block:: none
juju config neutron-api enable-sriov=true
juju config ovn-chassis enable-sriov=true
juju config ovn-chassis sriov-device-mappings=physnet2:enp3s0f0
juju config ovn-chassis sriov-numvfs=enp3s0f0:4
.. caution::
After deploying the above example the machines hosting ovn-chassis
units must be rebooted for the changes to take effect.
After enabling the virtual functions you should take note of the ``vendor_id``
and ``product_id`` of the virtual functions:
.. code-block:: none
juju run --application ovn-chassis 'lspci -nn | grep "Virtual Function"'
.. code-block:: console
03:10.0 Ethernet controller [0200]: Intel Corporation 82599 Ethernet Controller Virtual Function [8086:10ed] (rev 01)
03:10.2 Ethernet controller [0200]: Intel Corporation 82599 Ethernet Controller Virtual Function [8086:10ed] (rev 01)
03:10.4 Ethernet controller [0200]: Intel Corporation 82599 Ethernet Controller Virtual Function [8086:10ed] (rev 01)
03:10.6 Ethernet controller [0200]: Intel Corporation 82599 Ethernet Controller Virtual Function [8086:10ed] (rev 01)
In the above example ``vendor_id`` is '8086' and ``product_id`` is '10ed'.
Add mapping between physical network name, physical port and Open vSwitch
bridge:
.. code-block:: none
juju config ovn-chassis ovn-bridge-mappings=physnet2:br-ex
juju config ovn-chassis bridge-interface-mappings br-ex:a0:36:9f:dd:37:a8
.. note::
The above configuration allows OVN to configure an 'external' port on one
of the chassis for providing DHCP and metadata to instances connected
directly to the network through SR-IOV.
For OpenStack to make use of the VFs the ``neutron-sriov-agent`` needs to talk
to RabbitMQ:
.. code:: bash
juju add-relation ovn-chassis:amqp rabbitmq-server:amqp
OpenStack Nova also needs to know which PCI devices it is allowed to pass
through to instances:
.. code:: bash
juju config nova-compute pci-passthrough-whitelist='{"vendor_id":"8086", "product_id":"10ed", "physical_network":"physnet2"}'
Boot an instance
^^^^^^^^^^^^^^^^
Now we can tell OpenStack to boot an instance and attach it to an SR-IOV port.
This must be done in two stages, first we create a port with ``vnic-type``
'direct' and then we create an instance connected to the newly created port:
.. code:: bash
openstack port create --network my-network --vnic-type direct my-port
openstack server create --flavor my-flavor --key-name my-key \
--nic port-id=my-port my-instance
DPDK support
~~~~~~~~~~~~
It is possible to configure chassis to use experimental DPDK userspace network
acceleration.
.. note::
Currently instances are required to be attached to a external network (also
known as provider network) for connectivity. OVN supports distributed DHCP
for provider networks. For OpenStack workloads use of `Nova config drive`_
is required to provide metadata to instances.
Prerequisites
^^^^^^^^^^^^^
To use the feature you need to use a supported CPU architecture and network
interface card (NIC) hardware. Please consult the `DPDK supported hardware
page`_.
Machines need to be pre-configured with appropriate kernel command-line
parameters. The charm does not handle this facet of configuration and it is
expected that the user configure this either manually or through the bare metal
provisioning layer (for example `MAAS`_).
Example:
.. code:: bash
default_hugepagesz=1G hugepagesz=1G hugepages=64 intel_iommu=on iommu=pt
For the communication between the host userspace networking stack and the guest
virtual NIC driver to work the instances need to be configured to use
hugepages. For OpenStack this can be accomplished by `Customizing instance huge
pages allocations`_.
Example:
.. code:: bash
openstack flavor set m1.large --property hw:mem_page_size=large
By default, the charm will configure Open vSwitch/DPDK to consume one processor
core + 1G of RAM from each NUMA node on the unit being deployed. This can be
tuned using the ``dpdk-socket-memory`` and ``dpdk-socket-cores`` configuration
options.
.. note::
Please check that the value of dpdk-socket-memory is large enough to
accommodate the MTU size being used. For more information please refer to
`DPDK shared memory calculations`_
The userspace kernel driver can be configured using the ``dpdk-driver``
configuration option. See config.yaml for more details.
.. note::
Changing dpdk related configuration options will trigger a restart of
Open vSwitch, and subsequently interrupt instance connectivity.
Charm configuration
^^^^^^^^^^^^^^^^^^^
The below example bundle excerpt will enable the use of DPDK for an OVN
deployment.
.. code-block:: yaml
ovn-chassis-dpdk:
options:
enable-dpdk: True
bridge-interface-mappings: br-ex:00:53:00:00:00:42
ovn-chassis:
options:
enable-dpdk: False
bridge-interface-mappings: br-ex:bond0
prefer-chassis-as-gw: True
.. caution::
As configured by the charms, the units configured to use DPDK will not
participate in the overlay network and will also not be able to provide
services such as external DHCP to SR-IOV enabled units in the same
deployment.
As such it is important to have at least one other named ovn-chassis
application in the deployment with ``enable-dpdk`` set to 'False' and the
``prefer-chassis-as-gw`` configuration option set to 'True'. Doing so will
inform the CMS (Cloud Management System) that shared services such as
gateways and external DHCP services should not be scheduled to the
DPDK-enabled nodes.
DPDK bonding
............
Once Network interface cards are bound to DPDK they will be invisible to the
standard Linux kernel network stack and subsequently it is not possible to use
standard system tools to configure bonding.
For DPDK interfaces the charm supports configuring bonding in Open vSwitch.
This is accomplished through the ``dpdk-bond-mappings`` and
``dpdk-bond-config`` configuration options. Example:
.. code:: yaml
ovn-chassis-dpdk:
options:
enable-dpdk: True
bridge-interface-mappings: br-ex:dpdk-bond0
dpdk-bond-mappings: "dpdk-bond0:00:53:00:00:00:42 dpdk-bond0:00:53:00:00:00:51"
dpdk-bond-config: ":balance-slb:off:fast"
ovn-chassis:
options:
enable-dpdk: False
bridge-interface-mappings: br-ex:bond0
prefer-chassis-as-gw: True
In this example, the network interface cards associated with the two MAC
addresses provided will be used to build a bond identified by a port named
'dpdk-bond0' which will be attached to the 'br-ex' bridge.
Internal DNS resolution
~~~~~~~~~~~~~~~~~~~~~~~
OVN supports Neutron internal DNS resolution. To configure this:
.. caution::
At the time of this writing the internal DNS support does not include
reverse lookup (PTR-records) of instance IP addresses, only forward lookup
(A and AAAA-records) of instance names. This is tracked in `LP #1857026`_.
.. code::
juju config neutron-api enable-ml2-dns=true
juju config neutron-api dns-domain=openstack.example.
juju config neutron-api-plugin-ovn dns-servers="1.1.1.1 8.8.8.8"
.. note::
The value for the ``dns-domain`` configuration option must
not be set to 'openstack.local.' as that will effectively disable the
feature.
It is also important to end the string with a '.' (dot).
When you set ``enable-ml2-dns`` to 'true' and set a value for ``dns-domain``,
Neutron will add details such as instance name and DNS domain name to each
individual Neutron port associated with instances. The OVN ML2 driver will
populate the ``DNS`` table of the Northbound and Southbound databases:
.. code::
# ovn-sbctl list DNS
_uuid : 2e149fa8-d27f-4106-99f5-a08f60c443bf
datapaths : [b25ed99a-89f1-49cc-be51-d215aa6fb073]
external_ids : {dns_id="4c79807e-0755-4d17-b4bc-eb57b93bf78d"}
records : {"c-1"="192.0.2.239", "c-1.openstack.example"="192.0.2.239"}
On the chassis, OVN creates flow rules to redirect UDP port 53 packets (DNS)
to the local ``ovn-controller`` process:
.. code::
cookie=0xdeaffed, duration=77.575s, table=22, n_packets=0, n_bytes=0, idle_age=77, priority=100,udp6,metadata=0x2,tp_dst=53 actions=controller(userdata=00.00.00.06.00.00.00.00.00.01.de.10.00.00.00.64,pause),resubmit(,23)
cookie=0xdeaffed, duration=77.570s, table=22, n_packets=0, n_bytes=0, idle_age=77, priority=100,udp,metadata=0x2,tp_dst=53 actions=controller(userdata=00.00.00.06.00.00.00.00.00.01.de.10.00.00.00.64,pause),resubmit(,23)
The local ``ovn-controller`` process then decides if it should respond to the
DNS query directly or if it needs to be forwarded to the real DNS server.
External connectivity
~~~~~~~~~~~~~~~~~~~~~
Interface and network to bridge mapping is done through the
`ovn-chassis charm`_.
OVN provides a more flexible way of configuring external Layer3 networking than
the legacy ML2+DVR configuration as OVN does not require every node
(``Chassis`` in OVN terminology) in a deployment to have direct external
connectivity. This plays nicely with Layer3-only datacenter fabrics (RFC 7938).
East/West traffic is distributed by default. North/South traffic is highly
available by default. Liveness detection is done using the Bidirectional
Forwarding Detection (BFD) protocol.
Networks for use with external Layer3 connectivity should have mappings on
chassis located in the vicinity of the datacenter border gateways. Having two
or more chassis with mappings for a Layer3 network will have OVN automatically
configure highly available routers with liveness detection provided by the
Bidirectional Forwarding Detection (BFD) protocol.
Chassis without direct external mapping to a external Layer3 network will
forward traffic through a tunnel to one of the chassis acting as a gateway for
that network.
Networks for use with external Layer2 connectivity should have mappings present
on all chassis with potential to host the consuming payload.
.. note::
It is not necessary nor recommended to add mapping for external
Layer3 networks to all chassis. Doing so will create a scaling problem at
the physical network layer that needs to be resolved with globally shared
Layer2 (does not scale) or tunneling at the top-of-rack switch layer (adds
complexity) and is generally not a recommended configuration.
Example configuration with explicit bridge-interface-mappings:
.. code:: bash
juju config neutron-api flat-network-providers=physnet1
juju config ovn-chassis ovn-bridge-mappings=physnet1:br-provider
juju config ovn-chassis \
bridge-interface-mappings='br-provider:00:00:5e:00:00:42 \
br-provider:00:00:5e:00:00:51'
openstack network create --external --share --provider-network-type flat \
--provider-physical-network physnet1 ext-net
openstack subnet create --network ext-net \
--subnet-range 192.0.2.0/24 \
--no-dhcp --gateway 192.0.2.1 \
ext
It is also possible to influence the scheduling of routers on a per named
ovn-chassis application basis. The benefit of this method is that you do not
need to provide MAC addresses when configuring Layer3 connectivity in the
charm. For example:
.. code-block:: none
juju config ovn-chassis-border \
ovn-bridge-mappings=physnet1:br-provider \
bridge-interface-mappings=br-provider:bond0 \
prefer-chassis-as-gw=true
juju config ovn-chassis \
ovn-bridge-mappings=physnet1:br-provider \
bridge-interface-mappings=br-provider:bond0 \
In the above example units of the ovn-chassis-border application with
appropriate bridge mappings will be eligible for router scheduling.
Usage
-----
Create networks, routers and subnets through the OpenStack API or CLI as you
normally would.
The OVN ML2 driver will translate the OpenStack network constructs into high
level logical rules in the OVN Northbound database.
The ``ovn-northd`` daemon in turn translates this into data in the Southbound
database.
The local ``ovn-controller`` daemon on each chassis consumes these rules and
programs flows in the local Open vSwitch database.
Information queries
~~~~~~~~~~~~~~~~~~~
The OVN databases are configured to use the `Clustered Database Service
Model`_. In this configuration only the leader processes transactions and the
administrative client tools are configured to require a connection to the
leader to operate.
The leader of the Northbound and Southbound databases does not have to coincide
with the charm leader, so before querying databases you must consult the output
of :command:`juju status` to check which unit is the leader of the database you
want to query. Example:
.. code-block:: none
juju status ovn-central
.. code-block:: console
Unit Workload Agent Machine Public address Ports Message
ovn-central/0* active idle 0/lxd/5 10.246.114.39 6641/tcp,6642/tcp Unit is ready (leader: ovnnb_db)
ovn-central/1 active idle 1/lxd/4 10.246.114.15 6641/tcp,6642/tcp Unit is ready (northd: active)
ovn-central/2 active idle 2/lxd/2 10.246.114.27 6641/tcp,6642/tcp Unit is ready (leader: ovnsb_db)
In the above example 'ovn-central/0' is the leader for the Northbound DB,
'ovn-central/1' has the active ``ovn-northd`` daemon and 'ovn-central/2' is the
leader for the Southbound DB.
OVSDB Cluster status
^^^^^^^^^^^^^^^^^^^^
The cluster status as conveyed through :command:`juju status` is updated each
time a hook is run, in some circumstances it may be necessary to get an
immediate view of the current cluster status.
To get an immediate view of the database clusters:
.. code-block:: none
juju run --application ovn-central 'ovn-appctl -t \
/var/run/ovn/ovnnb_db.ctl cluster/status OVN_Northbound'
juju run --application ovn-central 'ovn-appctl -t \
/var/run/ovn/ovnsb_db.ctl cluster/status OVN_Southbound'
Querying DBs
^^^^^^^^^^^^
To query the individual databases:
.. code-block:: none
juju run --unit ovn-central/0 'ovn-nbctl show'
juju run --unit ovn-central/2 'ovn-sbctl show'
juju run --unit ovn-central/2 'ovn-sbctl lflow-list'
As an alternative you may provide the administrative client tools with
command-line arguments for path to certificates and IP address of servers so
that you can run the client from anywhere:
.. code-block:: none
ovn-nbctl \
-p /etc/ovn/key_host \
-C /etc/ovn/ovn-central.crt \
-c /etc/ovn/cert_host \
--db ssl:10.246.114.39:6641,ssl:10.246.114.15:6641,ssl:10.246.114.27:6641 \
show
Note that for remote administrative write access to the Southbound DB you must
use port number '16642'. This is due to OVN RBAC being enabled on the standard
'6642' port:
.. code-block:: none
ovn-sbctl \
-p /etc/ovn/key_host \
-C /etc/ovn/ovn-central.crt \
-c /etc/ovn/cert_host \
--db ssl:10.246.114.39:16642,ssl:10.246.114.15:16642,ssl:10.246.114.27:16642 \
show
Data plane flow tracing
^^^^^^^^^^^^^^^^^^^^^^^
SSH into one of the chassis units to get access to various diagnostic tools:
.. code-block:: none
juju ssh ovn-chassis/0
sudo ovs-vsctl show
sudo ovs-ofctl -O OpenFlow13 dump-flows br-int
sudo ovs-appctl -t ovs-vswitchd \
ofproto/trace br-provider \
in_port=enp3s0f0,icmp,nw_src=192.0.2.1,nw_dst=192.0.2.100
sudo ovn-trace \
-p /etc/ovn/key_host \
-C /etc/ovn/ovn-chassis.crt \
-c /etc/ovn/cert_host \
--db ssl:10.246.114.39:6642,ssl:10.246.114.15:6642,ssl:10.246.114.27:6642 \
--ovs ext-net 'inport=="provnet-dde76bc9-0620-44f7-b99a-99cfc66e1095" && \
eth.src==30:e1:71:5c:7a:b5 && \
eth.dst==fa:16:3e:f7:15:73 && \
ip4.src==10.172.193.250 && \
ip4.dst==10.246.119.8 && \
icmp4.type==8 && \
ip.ttl == 64'
.. note::
OVN makes use of OpenFlow 1.3 or newer and as such the charm configures
bridges to use these protocols. To be able to successfully use the
:command:`ovs-ofctl` command you must specify the OpenFlow version as shown
in the example above.
You may issue the :command:`ovs-vsctl list bridge` command to show what
protocols are enabled on the bridges.
Migration from Neutron ML2+OVS to ML2+OVN
-----------------------------------------
MTU considerations
~~~~~~~~~~~~~~~~~~
When migrating from ML2+OVS to ML2+OVN there will be a change of encapsulation
for the tunnels in the overlay network to ``geneve``. A side effect of the
change of encapsulation is that the packets transmitted on the physical network
get larger.
You must examine the existing configuration of network equipment, physical
links on hypervisors and configuration of existing virtual project networks to
determine if there is room for this growth.
Making room for the growth could be accomplished by increasing the MTU
configuration on the physical network equipment and hypervisor physical links.
If this can be done then steps #1 and #9 below can be skipped, where it is
shown how to **reduce** the MTU on all existing cloud instances.
Remember to take any other encapsulation used in your physical network
equipment into account when calculating the MTU (VLAN tags, MPLS labels etc.).
Encapsulation types and their overhead:
+---------------+----------+------------------------+
| Encapsulation | Overhead | Difference from Geneve |
+===============+==========+========================+
| Geneve | 38 Bytes | 0 Bytes |
+---------------+----------+------------------------+
| VXLAN | 30 Bytes | 8 Bytes |
+---------------+----------+------------------------+
| GRE | 22 Bytes | 16 bytes |
+---------------+----------+------------------------+
Confirmation of migration actions
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Many of the actions used for the migration require a confirmation from the
operator by way of the ``i-really-mean-it`` parameter.
This parameter accepts the values 'true' or 'false'. If 'false' the requested
operation will either not be performed, or will be performed in dry-run mode,
if 'true' the requested operation will be performed.
In the examples below the parameter will not be listed, this is deliberate to
avoid accidents caused by cutting and pasting the wrong command into a
terminal.
Prepare for migration
~~~~~~~~~~~~~~~~~~~~~
This section contains the preparation steps that will ensure minimal instance
down time during the migration. Ensure that you have studied them in advance
of the actual migration.
.. important::
Allow for at least 24 hours to pass between the completion of the
preparation steps and the commencement of the actual migration steps.
This is particularly necesseary because depending on your physical network
configuration, it may be required to reduce the MTU size on all cloud
instances as part of the migration.
1. Reduce MTU on all instances in the cloud if required
Please refer to the MTU considerations section above.
* Instances using DHCP can be controlled centrally by the cloud operator
by overriding the MTU advertised by the DHCP server.
.. code-block:: none
juju config neutron-gateway instance-mtu=1300
juju config neutron-openvswitch instance-mtu=1300
* Instances using IPv6 RA or SLAAC will automatically adjust
their MTU as soon as OVN takes over announcing the RAs.
* Any instances not using DHCP must be configured manually by the end user of
the instance.
2. Confirm cloud subnet configuration
* Confirm that all subnets have IP addresses available for allocation.
During the migration OVN may create a new port in subnets and allocate an
IP address to it. Depending on the type of network, this port will be used
for either the OVN metadata service or for the SNAT address assigned to an
external router interface.
.. warning::
If a subnet has no free IP addresses for allocation the migration will
fail.
* Confirm that all subnets have a valid DNS server configuration.
OVN handles instance access to DNS differently to how ML2+OVS does. Please
refer to the Internal DNS resolution paragraph in this document for
details.
When the subnet ``dns_nameservers`` attribute is empty the OVN DHCP server
will provide instances with the DNS addresses specified in the
neutron-api-plugin-ovn ``dns-servers`` configuration option. If any of
your subnets have the ``dns_nameservers`` attribute set to the IP address
ML2+OVS used for instance DNS (usually the .2 address of the project
subnet) you will need to remove this configuration.
3. Make a fresh backup copy of the Neutron database
4. Deploy the OVN components and Vault
In your Juju model you can have a charm deployed multiple times using
different application names. In the text below this will be referred to as
"named application". One example where this is common is for deployments
with Octavia where it is common to use a separate named application for
neutron-openvswtich for use with the Octavia units.
In addition to the central components you should deploy an ovn-chassis
named application for every neutron-openvswitch named application in your
deployment. For every neutron-gateway named application you should deploy an
ovn-dedicated-chassis named application to the same set of machines.
At this point in time each hypervisor or gateway will have a Neutron
Open vSwitch (OVS) agent managing the local OVS instance. Network loops
may occur if an ovn-chassis unit is started as it will also attempt to
manage OVS. To avoid this, deploy ovn-chassis (or ovn-dedicated-chassis) in
a paused state by setting the ``new-units-paused`` configuration option to
'true':
.. code-block:: none
juju deploy ovn-central \
--series focal \
-n 3 \
--to lxd:0,lxd:1,lxd:2
juju deploy ovn-chassis \
--series focal \
--config new-units-paused=true \
--config bridge-interface-mappings='br-provider:00:00:5e:00:00:42' \
--config ovn-bridge-mappings=physnet1:br-provider
juju deploy ovn-dedicated-chassis \
--series focal \
--config new-units-paused=true \
--config bridge-interface-mappings='br-provider:00:00:5e:00:00:51' \
--config ovn-bridge-mappings=physnet1:br-provider \
-n 2 \
--to 3,4
juju deploy --series focal mysql-router vault-mysql-router
juju deploy --series focal vault
juju add-relation vault-mysql-router:db-router \
mysql-innodb-cluster:db-router
juju add-relation vault-mysql-router:shared-db vault:shared-db
juju add-relation ovn-central:certificates vault:certificates
juju add-relation ovn-chassis:certificates vault:certificates
juju add-relation ovn-chassis:ovsdb ovn-central:ovsdb
juju add-relation nova-compute:neutron-plugin ovn-chassis:nova-compute
The values to use for the ``bridge-interface-mappings`` and
``ovn-bridge-mappings`` configuration options can be found by looking at
what is set for the ``data-port`` and ``bridge-mappings`` configuration
options on the neutron-openvswitch and/or neutron-gateway applications.
.. note::
In the above example the placement given with the ``--to`` parameter to
:command:`juju` is just an example. Your deployment may also have
multiple named applications of the neutron-openvswitch charm and/or
mutliple applications related to the neutron-openvswitch named
applications. You must tailor the commands to fit with your deployments
topology.
5. Unseal Vault (see the `vault charm`_), set up TLS certificates (see
`Managing TLS certificates`_), and validate that the services on ovn-central
units are running as expected. Please refer to the `Usage`_ section for more
information.
Perform migration
~~~~~~~~~~~~~~~~~
6. Change firewall driver to 'openvswitch'
To be able to successfully clean up after the Neutron agents on hypervisors
we need to instruct the neutron-openvswitch charm to use the 'openvswitch'
firewall driver. This is accomplished by setting the ``firewall-driver``
configuration option to 'openvswitch'.
.. code-block:: none
juju config neutron-openvswitch firewall-driver=openvswitch
7. Pause neutron-openvswitch and/or neutron-gateway units.
If your deployments have two neutron-gateway units and four
neutron-openvswitch units the sequence of commands would be:
.. code-block:: none
juju run-action neutron-gateway/0 pause
juju run-action neutron-gateway/1 pause
juju run-action neutron-openvswitch/0 pause
juju run-action neutron-openvswitch/1 pause
juju run-action neutron-openvswitch/2 pause
juju run-action neutron-openvswitch/3 pause
8. Deploy the Neutron OVN plugin application
.. code-block:: none
juju deploy neutron-api-plugin-ovn \
--series focal \
--config dns-servers=="1.1.1.1 8.8.8.8"
juju add-relation neutron-api-plugin-ovn:neutron-plugin \
neutron-api:neutron-plugin-api-subordinate
juju add-relation neutron-api-plugin-ovn:certificates \
vault:certificates
juju add-relation neutron-api-plugin-ovn:ovsdb-cms ovn-central:ovsdb-cms
The values to use for the ``dns-servers`` configuration option can be
found by looking at what is set for the ``dns-servers`` configuration
option on the neutron-openvswitch and/or neutron-gateway applications.
.. note::
The plugin will not be activated until the neutron-api
``manage-neutron-plugin-legacy-mode`` configuration option is changed in
step 9.
9. Adjust MTU on overlay networks (if required)
Now that 24 hours have passed since we reduced the MTU on the instances
running in the cloud as described in step 1, we can update the MTU setting
for each individual Neutron network:
.. code-block:: none
juju run-action --wait neutron-api-plugin-ovn/0 migrate-mtu
10. Enable the Neutron OVN plugin
.. code-block:: none
juju config neutron-api manage-neutron-plugin-legacy-mode=false
Wait for the deployment to settle.
11. Pause the Neutron API units
.. code-block:: none
juju run-action neutron-api/0 pause
juju run-action neutron-api/1 pause
juju run-action neutron-api/2 pause
Wait for the deployment to settle.
12. Perform initial synchronization of the Neutron and OVN databases
.. code-block:: none
juju run-action --wait neutron-api-plugin-ovn/0 migrate-ovn-db
13. (Optional) Perform Neutron database surgery to update ``network_type`` of
overlay networks to 'geneve'.
At the time of this writing the Neutron OVN ML2 driver will assume that all
chassis participating in a network are using the 'geneve' tunnel protocol
and it will ignore the value of the `network_type` field in any
non-physical network in the Neutron database. It will also ignore the
`segmentation_id` field and let OVN assign the VNIs.
The Neutron API currently does not support changing the type of a network,
so when doing a migration the above described behaviour is actually a
welcome one.
However, after the migration is done and all the primary functions are
working, i.e. packets are forwarded. The end user of the cloud will be left
with the false impression of their existing 'gre' or 'vxlan' typed networks
still being operational on said tunnel protocols, while in reality 'geneve'
is used under the hood.
The end user will also run into issues with modifying any existing networks
with `openstack network set` throwing error messages about networks of type
'gre' or 'vxlan' not being supported.
After running this action said networks will have their `network_type`
field changed to 'geneve' which will fix the above described problems.
.. code-block:: none
juju run-action --wait neutron-api-plugin-ovn/0 offline-neutron-morph-db
14. Resume the Neutron API units
.. code-block:: none
juju run-action neutron-api/0 resume
juju run-action neutron-api/1 resume
juju run-action neutron-api/2 resume
Wait for the deployment to settle.
15. Migrate hypervisors and gateways
The final step of the migration is to clean up after the Neutron agents
on the hypervisors/gateways and enable the OVN services so that they can
reprogram the local Open vSwitch.
This can be done one gateway / hypervisor at a time or all at once to your
discretion.
.. note::
During the migration instances running on a non-migrated hypervisor will
not be able to reach instances on the migrated hypervisors.
.. caution::
When migrating a cloud with Neutron ML2+OVS+DVR+SNAT topology care should
be taken to take into account on which hypervisors essential agents are
running to minimize downtime for any instances on other hypervisors with
dependencies on them.
.. code-block:: none
juju run-action --wait neutron-openvswitch/0 cleanup
juju run-action --wait ovn-chassis/0 resume
juju run-action --wait neutron-gateway/0 cleanup
juju run-action --wait ovn-dedicated-chassis/0 resume
16. Post migration tasks
Remove the now redundant Neutron ML2+OVS agents from hypervisors and
any dedicated gateways as well as the neutron-gateway and
neutron-openvswitch applications from the Juju model:
.. code-block:: none
juju run --application neutron-gateway '\
apt remove -y neutron-dhcp-agent neutron-l3-agent \
neutron-metadata-agent neutron-openvswitch-agent'
juju remove-application neutron-gateway
juju run --application neutron-openvswitch '\
apt remove -y neutron-dhcp-agent neutron-l3-agent \
neutron-metadata-agent neutron-openvswitch-agent'
juju remove-application neutron-openvswitch
Remove the now redundant Neutron ML2+OVS agents from the Neutron database:
.. code-block:: none
openstack network agent list
openstack network agent delete ...
.. LINKS
.. _vault charm: https://jaas.ai/vault/
.. _Managing TLS certificates: app-certificate-management.html
.. _Toward Convergence of ML2+OVS+DVR and OVN: http://specs.openstack.org/openstack/neutron-specs/specs/ussuri/ml2ovs-ovn-convergence.html
.. _ovn-dedicated-chassis charm: https://jaas.ai/u/openstack-charmers/ovn-dedicated-chassis/
.. _networking-ovn plugin: https://docs.openstack.org/networking-ovn/latest/
.. _neutron-api charm: https://jaas.ai/neutron-api/
.. _neutron-api-plugin-ovn charm: https://jaas.ai/u/openstack-charmers/neutron-api-plugin-ovn/
.. _ovn-chassis charm: https://jaas.ai/u/openstack-charmers/ovn-chassis/
.. _OpenStack Base bundle: https://github.com/openstack-charmers/openstack-bundles/tree/master/development/openstack-base-bionic-ussuri-ovn
.. _gaps from ML2/OVS: https://docs.openstack.org/neutron/latest/ovn/gaps.html
.. _OVN section of the Infrastructure high availability: https://docs.openstack.org/charm-guide/latest/admin/ha.html#ovn
.. _OpenStack Charms Deployment Guide: https://docs.openstack.org/project-deploy-guide/charm-deployment-guide/latest/
.. _Nova config drive: https://docs.openstack.org/nova/latest/user/metadata.html#config-drives
.. _DPDK supported hardware page: http://core.dpdk.org/supported/
.. _MAAS: https://maas.io/
.. _Customizing instance huge pages allocations: https://docs.openstack.org/nova/latest/admin/huge-pages.html#customizing-instance-huge-pages-allocations
.. _Hardware offloading: app-hardware-offload.html
.. _SR-IOV for networking support: app-ovn.html#sr-iov-for-networking-support
.. _traffic control monitor: http://manpages.ubuntu.com/manpages/focal/man8/tc.8.html#monitor
.. _data path control tools: http://manpages.ubuntu.com/manpages/focal/man8/ovs-dpctl.8.html
.. _Clustered Database Service Model: http://docs.openvswitch.org/en/latest/ref/ovsdb.7/#clustered-database-service-model
.. _DPDK shared memory calculations: https://docs.openvswitch.org/en/latest/topics/dpdk/memory/#shared-memory-calculations
.. _Usage: app-ovn#usage
.. BUGS
.. _LP #1857026: https://bugs.launchpad.net/ubuntu/+source/ovn/+bug/1857026