VMAX Rocky doc - version information
Updating version information and adding supported features.
Change-Id: Ib19433d7d694f70cf47f2e654d02c19fc89e8469
(cherry picked from commit 7262964ce9)
This commit is contained in:
@@ -15,28 +15,28 @@ to perform VMAX storage operations.
|
|||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
KNOWN ISSUE:
|
KNOWN ISSUE:
|
||||||
Workload support was dropped in ucode 5978. If a VMAX All Flash array is
|
Workload support was dropped in PowerMax OS 5978. If a VMAX All Flash array
|
||||||
upgraded to 5978 or greater and existing volume types leveraged workload
|
is upgraded to PowerMax OS 5978 or greater and existing volume types
|
||||||
e.g. DSS, DSS_REP, OLTP and OLTP_REP, attaching and detaching will no
|
leveraged workload i.e. DSS, DSS_REP, OLTP and OLTP_REP, attaching and
|
||||||
longer work and the volume type will be unusable. Refrain from upgrading
|
detaching will no longer work and the volume type will be unusable.
|
||||||
to ucode 5978 or greater on an All Flash until a fix is merged. Please
|
Refrain from upgrading to PowerMax OS 5978 or greater on an All Flash
|
||||||
contact your Dell EMC VMAX customer support representative if in any
|
until a fix is merged. Please contact your Dell EMC VMAX customer support
|
||||||
doubt.
|
representative if in any doubt.
|
||||||
|
|
||||||
System requirements and licensing
|
System requirements and licensing
|
||||||
=================================
|
=================================
|
||||||
|
|
||||||
The Dell EMC VMAX Cinder driver supports the VMAX-3 hybrid series and VMAX
|
The Dell EMC VMAX Cinder driver supports the VMAX-3 hybrid series, VMAX
|
||||||
All-Flash arrays.
|
All-Flash series and the PowerMax arrays.
|
||||||
|
|
||||||
The array operating system software, Solutions Enabler 8.4.0.7 or later, and
|
The array operating system software, Solutions Enabler 9.0.0.0 or later, and
|
||||||
Unisphere for VMAX 8.4.0.15 or later are required to run Dell EMC VMAX Cinder
|
Unisphere for PowerMax 9.0.0.6 or later are required to run Dell EMC VMAX
|
||||||
driver.
|
Cinder driver.
|
||||||
|
|
||||||
You can download Solutions Enabler and Unisphere from the Dell EMC's support
|
Download Solutions Enabler and Unisphere from the Dell EMC's support web site
|
||||||
web site (login is required). See the ``Solutions Enabler 8.4.0 Installation
|
(login is required). See the ``Dell EMC Solutions Enabler 9.0 Installation
|
||||||
and Configuration Guide`` and ``Unisphere for VMAX 8.4.0 Installation Guide``
|
and Configuration Guide`` and ``Dell EMC Unisphere for PowerMax Installation
|
||||||
at ``support.emc.com``.
|
Guide`` at ``support.emc.com``.
|
||||||
|
|
||||||
Required VMAX software suites for OpenStack
|
Required VMAX software suites for OpenStack
|
||||||
-------------------------------------------
|
-------------------------------------------
|
||||||
@@ -110,6 +110,7 @@ VMAX drivers support these operations:
|
|||||||
- Volume replication SRDF/S, SRDF/A and SRDF Metro
|
- Volume replication SRDF/S, SRDF/A and SRDF Metro
|
||||||
- Quality of service (QoS)
|
- Quality of service (QoS)
|
||||||
- Manage and unmanage volumes and snapshots
|
- Manage and unmanage volumes and snapshots
|
||||||
|
- List Manageable Volumes/Snapshots
|
||||||
|
|
||||||
VMAX drivers also support the following features:
|
VMAX drivers also support the following features:
|
||||||
|
|
||||||
@@ -119,8 +120,14 @@ VMAX drivers also support the following features:
|
|||||||
- Oversubscription
|
- Oversubscription
|
||||||
- Service Level support
|
- Service Level support
|
||||||
- SnapVX support
|
- SnapVX support
|
||||||
- Compression support(All Flash only)
|
- Compression support(All Flash and PowerMax)
|
||||||
|
- Deduplication support(PowerMax)
|
||||||
- CHAP Authentication
|
- CHAP Authentication
|
||||||
|
- Multi-attach support
|
||||||
|
- Volume Metadata in logs
|
||||||
|
- Encrypted Volume support
|
||||||
|
- Extending attached volume
|
||||||
|
- Replicated volume retype support
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
@@ -186,7 +193,7 @@ contains ``child`` storage groups for each configured
|
|||||||
SRP/slo/workload/compression-enabled or disabled/replication-enabled or
|
SRP/slo/workload/compression-enabled or disabled/replication-enabled or
|
||||||
disabled combination.
|
disabled combination.
|
||||||
|
|
||||||
VMAX All Flash and Hybrid
|
PowerMax, VMAX All Flash and Hybrid
|
||||||
|
|
||||||
Parent storage group:
|
Parent storage group:
|
||||||
|
|
||||||
@@ -205,6 +212,11 @@ Child storage groups:
|
|||||||
CD and RE are only set if compression is explicitly disabled or replication
|
CD and RE are only set if compression is explicitly disabled or replication
|
||||||
explicitly enabled. See the compression and replication sections below.
|
explicitly enabled. See the compression and replication sections below.
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
For PowerMax and any All Flash with PowerMax OS (5978) or greater, workload
|
||||||
|
is NONE
|
||||||
|
|
||||||
|
|
||||||
VMAX Driver Integration
|
VMAX Driver Integration
|
||||||
=======================
|
=======================
|
||||||
@@ -219,16 +231,15 @@ VMAX Driver Integration
|
|||||||
Solutions Enabler can be installed on a physical server, or as a Virtual
|
Solutions Enabler can be installed on a physical server, or as a Virtual
|
||||||
Appliance (a VMware ESX server VM). Additionally, starting with HYPERMAX
|
Appliance (a VMware ESX server VM). Additionally, starting with HYPERMAX
|
||||||
OS Q3 2015, you can manage VMAX3 arrays using the Embedded Management
|
OS Q3 2015, you can manage VMAX3 arrays using the Embedded Management
|
||||||
(eManagement) container application. See the ``Solutions Enabler 8.4.0
|
(eManagement) container application. See the ``Dell EMC Solutions Enabler
|
||||||
Installation and Configuration Guide`` on ``support.emc.com`` for more
|
9.0 Installation and Configuration Guide`` on ``support.emc.com`` for
|
||||||
details.
|
more details.
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
You must discover storage arrays before you can use the VMAX drivers.
|
You must discover storage arrays before you can use the VMAX drivers.
|
||||||
Follow instructions in ``Solutions Enabler 8.4.0 Installation and
|
Follow instructions in ```Dell EMC Solutions Enabler 9.0 Installation
|
||||||
Configuration Guide`` on ``support.emc.com`` for more
|
and Configuration Guide`` on ``support.emc.com`` for more details.
|
||||||
details.
|
|
||||||
|
|
||||||
#. Download Unisphere from ``support.emc.com`` and install it.
|
#. Download Unisphere from ``support.emc.com`` and install it.
|
||||||
|
|
||||||
@@ -236,8 +247,8 @@ VMAX Driver Integration
|
|||||||
- i.e., on the same server running Solutions Enabler; on a server
|
- i.e., on the same server running Solutions Enabler; on a server
|
||||||
connected to the Solutions Enabler server; or using the eManagement
|
connected to the Solutions Enabler server; or using the eManagement
|
||||||
container application (containing Solutions Enabler and Unisphere for
|
container application (containing Solutions Enabler and Unisphere for
|
||||||
VMAX). See ``Unisphere for VMAX 8.4.0 Installation Guide`` at
|
VMAX). See ``Dell EMC Solutions Enabler 9.0 Installation and Configuration
|
||||||
``support.emc.com``.
|
Guide`` at ``support.emc.com``.
|
||||||
|
|
||||||
|
|
||||||
2. FC Zoning with VMAX
|
2. FC Zoning with VMAX
|
||||||
@@ -296,6 +307,8 @@ complex and open-zoning would raise security concerns.
|
|||||||
Service Level and workload can be added to the cinder.conf when the
|
Service Level and workload can be added to the cinder.conf when the
|
||||||
backend is the default case and there is no associated volume type.
|
backend is the default case and there is no associated volume type.
|
||||||
This not a recommended configuration as it is too restrictive.
|
This not a recommended configuration as it is too restrictive.
|
||||||
|
Workload is NONE for PowerMax and any All Flash with PowerMax OS
|
||||||
|
(5978) or greater.
|
||||||
|
|
||||||
+-----------------+------------------------+---------+----------+
|
+-----------------+------------------------+---------+----------+
|
||||||
| VMAX parameter | cinder.conf parameter | Default | Required |
|
| VMAX parameter | cinder.conf parameter | Default | Required |
|
||||||
@@ -422,6 +435,8 @@ complex and open-zoning would raise security concerns.
|
|||||||
is the additional property which has to be set and is of the format:
|
is the additional property which has to be set and is of the format:
|
||||||
``<ServiceLevel>+<Workload>+<SRP>+<Array ID>``.
|
``<ServiceLevel>+<Workload>+<SRP>+<Array ID>``.
|
||||||
This can be obtained from the output of the ``cinder get-pools--detail``.
|
This can be obtained from the output of the ``cinder get-pools--detail``.
|
||||||
|
Workload is NONE for PowerMax or any All Flash with PowerMax OS (5978)
|
||||||
|
or greater.
|
||||||
|
|
||||||
.. code-block:: console
|
.. code-block:: console
|
||||||
|
|
||||||
@@ -465,9 +480,12 @@ complex and open-zoning would raise security concerns.
|
|||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
VMAX Hybrid supports Optimized, Diamond, Platinum, Gold, Silver, Bronze,
|
PowerMax and Hybrid support Optimized, Diamond, Platinum, Gold, Silver,
|
||||||
and NONE service levels. VMAX All Flash supports Diamond and None. Both
|
Bronze, and NONE service levels. VMAX All Flash supports Diamond and None.
|
||||||
support DSS_REP, DSS, OLTP_REP, OLTP, and None workloads.
|
Hybrid and All Flash support DSS_REP, DSS, OLTP_REP, OLTP, and None
|
||||||
|
workloads, the latter up until ucode 5977. There is no support for
|
||||||
|
workloads in PowerMax OS (5978) or greater.
|
||||||
|
|
||||||
|
|
||||||
7. Interval and Retries
|
7. Interval and Retries
|
||||||
-----------------------
|
-----------------------
|
||||||
@@ -1087,7 +1105,8 @@ uncompressed.
|
|||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
This feature is only applicable for All Flash arrays, 250F, 450F or 850F.
|
This feature is only applicable for All Flash arrays, 250F, 450F, 850F
|
||||||
|
and 950F and PowerMax 2000 and 8000.
|
||||||
|
|
||||||
Use case 1 - Compression disabled create, attach, detach, and delete volume
|
Use case 1 - Compression disabled create, attach, detach, and delete volume
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
@@ -1193,8 +1212,11 @@ Live migration configuration
|
|||||||
|
|
||||||
Please refer to the following for more information:
|
Please refer to the following for more information:
|
||||||
|
|
||||||
https://docs.openstack.org/nova/queens/admin/live-migration-usage.html
|
https://docs.openstack.org/nova/latest/admin/live-migration-usage.html
|
||||||
https://docs.openstack.org/nova/queens/admin/configuring-migrations.html
|
|
||||||
|
and
|
||||||
|
|
||||||
|
https://docs.openstack.org/nova/latest/admin/configuring-migrations.html
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
@@ -1373,6 +1395,55 @@ We then decide to detach the volume from ‘Multi-attach-Instance-B’ on HostB:
|
|||||||
storage group. The non-FAST managed storage group is cleaned up,
|
storage group. The non-FAST managed storage group is cleaned up,
|
||||||
if required.
|
if required.
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
Known issue - the multi-attach flag is still false after a retype. This
|
||||||
|
is being addressed in https://bugs.launchpad.net/cinder/+bug/1790840
|
||||||
|
|
||||||
|
|
||||||
|
15. Volume Encryption support
|
||||||
|
-----------------------------
|
||||||
|
|
||||||
|
Please refer to the following:
|
||||||
|
https://docs.openstack.org/cinder/latest/configuration/block-storage/volume-encryption.html
|
||||||
|
|
||||||
|
|
||||||
|
16. Volume metadata in logs
|
||||||
|
---------------------------
|
||||||
|
|
||||||
|
If debug is enabled in the default section of the cinder.conf, VMAX Cinder
|
||||||
|
driver will log additional volume information in the Cinder volume log,
|
||||||
|
on each successful operation. The facilitates bridging the gap between
|
||||||
|
OpenStack and the Array by tracing and describing the volume from a VMAX/
|
||||||
|
PowerMax view point.
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
+-------------------------+---------------------------------------------------------+
|
||||||
|
| Key | Value |
|
||||||
|
+-------------------------+---------------------------------------------------------+
|
||||||
|
| service_level | Gold |
|
||||||
|
| is_compression_disabled | no |
|
||||||
|
| vmax_driver_version | 3.2.0 |
|
||||||
|
| identifier_name | OS-819470ab-a6d4-49cc-b4db-6f85e82822b7 |
|
||||||
|
| openstack_release | 13.0.0.0b3.dev3 |
|
||||||
|
| volume_id | 819470ab-a6d4-49cc-b4db-6f85e82822b7 |
|
||||||
|
| vmax_model | PowerMax_8000 |
|
||||||
|
| operation | delete |
|
||||||
|
| default_sg_name | OS-DEFAULT_SRP-Gold-NONE-SG |
|
||||||
|
| device_id | 01C03 |
|
||||||
|
| unisphere_version | V9.0.0.9 |
|
||||||
|
| workload | NONE |
|
||||||
|
| openstack_version | 13.0.0 |
|
||||||
|
| volume_updated_time | 2018-08-03 03:13:53 |
|
||||||
|
| platform | Linux-4.4.0-127-generic-x86_64-with-Ubuntu-16.04-xenial |
|
||||||
|
| python_version | 2.7.12 |
|
||||||
|
| volume_size | 20 |
|
||||||
|
| srp | DEFAULT_SRP |
|
||||||
|
| openstack_name | 91_Test_Vol56 |
|
||||||
|
| vmax_firmware_version | 5978.143.144 |
|
||||||
|
| serial_number | 000197600196 |
|
||||||
|
+-------------------------+---------------------------------------------------------+
|
||||||
|
|
||||||
|
|
||||||
Cinder supported operations
|
Cinder supported operations
|
||||||
@@ -1626,6 +1697,15 @@ retype, follow these steps:
|
|||||||
$ cinder retype --migration-policy on-demand <volume> <volume-type>
|
$ cinder retype --migration-policy on-demand <volume> <volume-type>
|
||||||
|
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
With the Rocky release the following is now supported
|
||||||
|
|
||||||
|
- Retype non-replicated volume to a replicated volume type
|
||||||
|
- Retype replicated volume to a non-replicated volume type
|
||||||
|
- Retype a replicated volume to a different replicated volume type
|
||||||
|
|
||||||
|
|
||||||
Generic volume group support
|
Generic volume group support
|
||||||
----------------------------
|
----------------------------
|
||||||
|
|
||||||
@@ -2105,6 +2185,55 @@ the VMAX backend will have the ``OS-`` prefix removed to indicate it is no
|
|||||||
longer OpenStack managed. In the example above, the snapshot after unmanaging
|
longer OpenStack managed. In the example above, the snapshot after unmanaging
|
||||||
from OpenStack will be named ``VMAXSnapshot`` on the storage backend.
|
from OpenStack will be named ``VMAXSnapshot`` on the storage backend.
|
||||||
|
|
||||||
|
List manageable volumes and snapshots
|
||||||
|
-------------------------------------
|
||||||
|
|
||||||
|
Manageable volumes
|
||||||
|
~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
Volumes that can be managed by and imported into Openstack.
|
||||||
|
|
||||||
|
List manageable volume is filtered by:
|
||||||
|
|
||||||
|
- Volume size should be 1026MB or greater (1GB VMAX Cinder Vol = 1026 MB)
|
||||||
|
- Volume size should be a whole integer GB capacity
|
||||||
|
- Volume should not be a part of masking view.
|
||||||
|
- Volume status should be ``Ready``
|
||||||
|
- Volume service state should be ``Normal``
|
||||||
|
- Volume emulation type should be ``FBA``
|
||||||
|
- Volume configuration should be ``TDEV``
|
||||||
|
- Volume should not be a system resource.
|
||||||
|
- Volume should not be ``private``
|
||||||
|
- Volume should not be ``encapsulated``
|
||||||
|
- Volume should not be ``reserved``
|
||||||
|
- Volume should not be a part of an RDF session
|
||||||
|
- Volume should not be a snapVX Target
|
||||||
|
- Volume identifier should not begin with ``OS-``.
|
||||||
|
|
||||||
|
Manageable snaphots
|
||||||
|
~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
Snapshots that can be managed by and imported into Openstack
|
||||||
|
|
||||||
|
List manageable snapshots is filtered by:
|
||||||
|
|
||||||
|
- The source volume should be marked as SnapVX source.
|
||||||
|
- The source volume should be 1026MB or greater
|
||||||
|
- The source volume should be a whole integer GB capacity.
|
||||||
|
- The source volume emulation type should be ``FBA``.
|
||||||
|
- The source volume configuration should be ``TDEV``.
|
||||||
|
- The source volume should not be ``private``.
|
||||||
|
- The source volume should be not be a system resource.
|
||||||
|
- The snapshot identifier should not start with ``OS-`` or ``temp-``.
|
||||||
|
- The snapshot should not be expired.
|
||||||
|
- The snapshot generation number should npt be greater than 0.
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
There is some delay in the syncing of the Unisphere for PowerMax database
|
||||||
|
when the state/properties of a volume is modified using ``symcli``. To
|
||||||
|
prevent this it is preferrable to modify state/properties of volumes within
|
||||||
|
Unisphere.
|
||||||
|
|
||||||
Upgrading from SMI-S based driver to RESTAPI based driver
|
Upgrading from SMI-S based driver to RESTAPI based driver
|
||||||
=========================================================
|
=========================================================
|
||||||
|
|||||||