Ceph RADOS Block Device (RBD)
=============================
If you use KVM or QEMU as your hypervisor, you can configure the Compute
service to use `Ceph RADOS block devices
(RBD) <https://ceph.com/ceph-storage/block-storage/>`__ for volumes.
Ceph is a massively scalable, open source, distributed storage system.
It is comprised of an object store, block store, and a POSIX-compliant
distributed file system. The platform can auto-scale to the exabyte
level and beyond. It runs on commodity hardware, is self-healing and
self-managing, and has no single point of failure. Due to its open-source
nature, you can install and use this portable storage platform in
public or private clouds.
.. figure:: ../../figures/ceph-architecture.png
Ceph architecture
RADOS
~~~~~
Ceph is based on Reliable Autonomic Distributed Object Store (RADOS).
RADOS distributes objects across the storage cluster and replicates
objects for fault tolerance. RADOS contains the following major
components:
*Object Storage Device (OSD) Daemon*
The storage daemon for the RADOS service, which interacts with the
OSD (physical or logical storage unit for your data).
You must run this daemon on each server in your cluster. For each
OSD, you can have an associated hard drive disk. For performance
purposes, pool your hard drive disk with raid arrays, or logical volume
management (LVM). By default, the following pools are created: data,
metadata, and RBD.
*Meta-Data Server (MDS)*
Stores metadata. MDSs build a POSIX file
system on top of objects for Ceph clients. However, if you do not use
the Ceph file system, you do not need a metadata server.
*Monitor (MON)*
A lightweight daemon that handles all communications
with external applications and clients. It also provides a consensus
for distributed decision making in a Ceph/RADOS cluster. For
instance, when you mount a Ceph shared on a client, you point to the
address of a MON server. It checks the state and the consistency of
the data. In an ideal setup, you must run at least three ``ceph-mon``
daemons on separate servers.
Ways to store, use, and expose data
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
To store and access your data, you can use the following storage
systems:
*RADOS*
Use as an object, default storage mechanism.
*RBD*
Use as a block device. The Linux kernel RBD (RADOS block
device) driver allows striping a Linux block device over multiple
distributed object store data objects. It is compatible with the KVM
RBD image.
*CephFS*
Use as a file, POSIX-compliant file system.
Ceph exposes RADOS; you can access it through the following interfaces:
*RADOS Gateway*
OpenStack Object Storage and Amazon-S3 compatible
RESTful interface (see `RADOS_Gateway
<http://docs.ceph.com/docs/master/radosgw/>`__).
*librados*
and its related C/C++ bindings
*RBD and QEMU-RBD*
Linux kernel and QEMU block devices that stripe
data across multiple objects.
RBD pool
~~~~~~~~
The RBD pool used by the Cinder backend is configured with option ``rbd_pool``,
and by default the driver expects exclusive management access to that pool, as
in being the only system creating and deleting resources in it, since that's
the recommended deployment choice.
Pool sharing is strongly discouraged, and if we were to share the pool with
other services, within OpenStack (Nova, Glance, another Cinder backend) or
outside of OpenStack (oVirt), then the stats returned by the driver to the
scheduler would not be entirely accurate.
The inaccuracy would be that the actual size in use by the cinder volumes would
be lower than the reported one, since it would be also including the used space
by the other services.
We can set the ``rbd_exclusive_cinder_pool`` configuration option to ``false``
to fix this inaccuracy, but this has a performance impact.
.. warning::
Setting ``rbd_exclusive_cinder_pool`` to ``false`` will increase the burden
on the Cinder driver and the Ceph cluster, since a request will be made for
each existing image, to retrieve its size, during the stats gathering
process.
For deployments with large amount of volumes it is recommended to leave the
default value of ``true``, and accept the inaccuracy, as it should not be
particularly problematic.
Driver options
~~~~~~~~~~~~~~
The following table contains the configuration options supported by the
Ceph RADOS Block Device driver.
.. config-table::
:config-target: Ceph storage
cinder.volume.drivers.rbd