2bdc086783
* Supported Protocol - iSCSI - FC * Supported Feature - Volume Attach/Detach(FC) - Extend Attached Volume - Volume Manage/Unmanage - Revert to Snapshot - Multi-attach - Thin Provisioning ThirdPartySystems: TOYOU ACS5000 CI Change-Id: Id9bd2f880ea92e9f74ba286a1cb25aea174328c5
3.0 KiB
3.0 KiB
TOYOU NetStor Cinder driver
TOYOU NetStor series volume driver provides OpenStack Compute instances with access to TOYOU NetStor series storage systems.
TOYOU NetStor storage can be used with iSCSI or FC connection.
This documentation explains how to configure and connect the block storage nodes to TOYOU NetStor series storage.
Driver options
The following table contains the configuration options supported by the TOYOU NetStor iSCSI/FC driver.
cinder.volume.drivers.toyou.acs5000.acs5000_common
Supported operations
- Create, list, delete, attach (map), and detach (unmap) volumes.
- Create, list and delete volume snapshots.
- Create a volume from a snapshot.
- Copy an image to a volume.
- Copy a volume to an image.
- Clone a volume.
- Extend a volume.
- Migrate a volume.
- Manage/Unmanage volume.
- Revert to Snapshot.
- Multi-attach.
- Thin Provisioning.
- Extend Attached Volume.
Configure TOYOU NetStor iSCSI/FC backend
This section details the steps required to configure the TOYOU NetStor storage cinder driver.
- In the
cinder.conf
configuration file under the[DEFAULT]
section, set the enabled_backends parameter with the iSCSI or FC back-end group.For Fibre Channel:
[DEFAULT] enabled_backends = toyou-fc-1
For iSCSI:
[DEFAULT] enabled_backends = toyou-iscsi-1
- Add a backend group section for the backend group specified in the enabled_backends parameter.
- In the newly created backend group section, set the following
configuration options:
For Fibre Channel:
[toyou-fc-1] # The TOYOU NetStor driver path volume_driver = cinder.volume.drivers.toyou.acs5000.acs5000_fc.Acs5000FCDriver # Management IP of TOYOU NetStor storage array san_ip = 10.0.0.10 # Management username of TOYOU NetStor storage array san_login = cliuser # Management password of TOYOU NetStor storage array san_password = clipassword # The Pool used to allocated volumes acs5000_volpool_name = pool01 # Backend name volume_backend_name = toyou-fc
For iSCSI:
[toyou-iscsi-1] # The TOYOU NetStor driver path volume_driver = cinder.volume.drivers.toyou.acs5000.acs5000_iscsi.Acs5000ISCSIDriver # Management IP of TOYOU NetStor storage array san_ip = 10.0.0.10 # Management username of TOYOU NetStor storage array san_login = cliuser # Management password of TOYOU NetStor storage array san_password = clipassword # The Pool used to allocated volumes acs5000_volpool_name = pool01 # Backend name volume_backend_name = toyou-iscsi