Files
deb-python-pyvmomi/docs/vim/host/StorageSystem.rst
Shawn Hartsock 15f7be9a52 pyVmomi reStructured Text Documentation
This external documentation for pyVmomi was generated using Googly Docs
(aka Google Standard Documentation) which renders very cleanly in
GitHub. Internal documentation for a class should be done in Sphinx
format because tools like pyCharm and Eclipse can use that documentation
as a hint for code completion.

Note: External docs as Googly Docs, internal docs as Sphinx.

Closes bug#15
2014-06-17 14:07:42 -04:00

49 KiB

vim.host.StorageSystem

This managed object gets and sets configuration information about the host's storage subsystem. The properties and operations are used to configure the host to make storage available for virtual machines. This object contains properties that are specific to ESX Server and general to both the ESX Server system and the hosted architecture.

extends

vim.ExtensibleManagedObject

Attributes

storageDeviceInfo (vim.host.StorageDeviceInfo):

Host storage information up to the device level.

fileSystemVolumeInfo (vim.host.FileSystemVolumeInfo):

File system volume information for the host. See the FileSystemVolumeInfo data object type for more information.

systemFile (str):

Datastore paths of files used by the host system on mounted volumes, for instance, the COS vmdk file of the host. For information on datastore paths, see Datastore .

multipathStateInfo (vim.host.MultipathStateInfo):

Runtime information about the state of a multipath path. A null value will be returned if path state information is not available for this system.In systems prior to the plug-store architecture, the state of a path may be accessible on the HostMultipathInfo data object of the storageDeviceInfo property.

Methods

RetrieveDiskPartitionInfo(devicePath):

Gets the partition information for the disks named by the device names.

Privilege:

System.Read

Args:
devicePath (str):

An array of device path names that identify disks. See ScsiDisk .

Returns:
vim.host.DiskPartitionInfo:

An array of information about the partitions.

ComputeDiskPartitionInfo(devicePath, layout, partitionFormat):

Computes the disk partition information given the desired disk layout. The server computes a new partition information object for a specific disk representing the desired layout.See HostDiskPartitionInfoPartitionFormat

Privilege:

Host.Config.Storage

Args:
devicePath (str):

The name of the device path for the specific disk.See HostDiskPartitionInfoPartitionFormat

layout (vim.host.DiskPartitionInfo.Layout):

A data object that describes the disk partition layout.See HostDiskPartitionInfoPartitionFormat

partitionFormat (str, optional, since vSphere API 5.0 ):

Specifies the desired partition format to be computed from the block range. If partitionFormat is not specified, the existing partitionFormat on disk is used, if the disk is not blank and mbr otherwise.See HostDiskPartitionInfoPartitionFormat

Returns:
vim.host.DiskPartitionInfo:

A data object that contains information about the partitions on a disk

Raises:

vim.fault.NotFound:

if the device could not be found.See HostDiskPartitionInfoPartitionFormat

vim.fault.HostConfigFault:

if unable to get the current partition information for the device.See HostDiskPartitionInfoPartitionFormat

vmodl.fault.InvalidArgument:

if the layout is invalid.See HostDiskPartitionInfoPartitionFormat

ComputeDiskPartitionInfoForResize(partition, blockRange, partitionFormat):

Computes the disk partition information for the purpose of resizing a given partition.See HostDiskPartitionInfoPartitionFormat since: vSphere API 4.0

Privilege:

Host.Config.Storage

Args:
partition (vim.host.ScsiDisk.Partition):

The disk partition to resize.See HostDiskPartitionInfoPartitionFormat

blockRange (vim.host.DiskPartitionInfo.BlockRange):

Specifies the desired block range for the resized partition. The start of the block range specified should match that of the current partition.See HostDiskPartitionInfoPartitionFormat

partitionFormat (str, optional, since vSphere API 5.0 ):

Specifies the desired partition format to be computed from the block range. If partitionFormat is not specified, the existing partitionFormat on disk is used, if the disk is not blank and mbr otherwise.See HostDiskPartitionInfoPartitionFormat

Returns:
vim.host.DiskPartitionInfo:

resized disk partition information

Raises:

vim.fault.NotFound:

if the device could not be found.See HostDiskPartitionInfoPartitionFormat

vim.fault.HostConfigFault:

if unable to get the current partition information for the device.See HostDiskPartitionInfoPartitionFormat

vmodl.fault.InvalidArgument:

if blockRange or partition is invalid.See HostDiskPartitionInfoPartitionFormat

UpdateDiskPartitions(devicePath, spec):

Changes the partitions on the disk by supplying a partition specification and the device name.

Privilege:

Host.Config.Storage

Args:
devicePath (str):

The name of the device path for the specific disk.

spec (vim.host.DiskPartitionInfo.Specification):

A data object that describes the disk partition table specification used to configure the partitions on a disk.

Returns:

None

Raises:

vim.fault.NotFound:

if the device could not be found.

vim.fault.HostConfigFault:

for all other configuration failures.

vmodl.fault.InvalidArgument:

if the spec is invalid.

FormatVmfs(createSpec):

Formats a new VMFS on a disk partition.

Privilege:

Host.Config.Storage

Args:
createSpec (vim.host.VmfsVolume.Specification):

A data object that describes the VMware File System (VMFS) creation specification.

Returns:
vim.host.VmfsVolume:

A data object that represents the VMFS file system.

Raises:

vim.fault.AlreadyExists:

if the volume name is already being used by another volume on the host.

vim.fault.HostConfigFault:

for all other configuration failures.

vmodl.fault.InvalidArgument:

if VMFS version specified is not 2 or 3, if blocksize, lock mode, or volume label are invalid, the partition does not exist or is of an invalid type.

MountVmfsVolume(vmfsUuid):

Mount the unmounted Vmfs volume. A newly discovered vmfs volume will be mounted unless, it has been explicitly unmounted. The default mount behavior of Vmfs volumes is auto-mount. See UnmountVmfsVolume .mountVmfsVolume is part of the Unmount / Detach workflow used when a device will be permanently removed. See also DetachScsiLun . since: vSphere API 5.0

Privilege:

Host.Config.Storage

Args:

vmfsUuid (str):

Returns:

None

Raises:

vim.fault.NotFound:

if VMFS Uuid is not found on the host.

vim.fault.InvalidState:
if
  • The volume is already mounted.
  • The volume is inaccessible.
vim.fault.HostConfigFault:

for all other configuration failures.

vim.fault.ResourceInUse:

vim.fault.ResourceInUse

UnmountVmfsVolume(vmfsUuid):
Unmount the Vmfs volume. An unmounted volume cannot be used for any filesystem operation requiring I/O. In contrast to removal, this operation does not destroy or alter partitions on which vmfs volumes reside. The mountState will be persisted across filesystem rescans and host reboots. See MountVmfsVolume .unmountVmfsVolume is part of the Unmount / Detach workflow used when a device will be permanently removed.Mounted Vmfs Volume unmountVmfsVolume | ^ mountVmfsVolume V | Unmounted Vmfs Volume Attached Scsi Device (honors I/O) detachScsiLun | ^ attachScsiLun V | Detached Scsi Device (does not honor I/O)It is safe to unprovision a Lun from the Storage array only after a Scsi device is detached.The best practice for decommisioning a Lun would be to find out the set of subsystems that a Lun is being used for. Many of the systems are listed as exceptions in the function documentation.One typical workflow could be:
  • Find out if the device is used as a Vmfs Extent. (See VmfsVolume.Extent API)
  • Unmount the Vmfs Volume.
  • Find out if device is used by the Diagnostic system (See Diagnostic System API).
  • Deactivate the diagnostic system, if it is being used.
  • Find out if this device is used to back a VM's RDM (See VirtualMachine API).
  • Remove this device from the VM.
  • Detach the Scsi device.
  • On success, it is safe to decommision the Lun at this point.See also DetachScsiLun .

since: vSphere API 5.0

Privilege:

Host.Config.Storage

Args:

vmfsUuid (str):

Returns:

None

Raises:

vim.fault.NotFound:

if VMFS Uuid is not found on the host.

vim.fault.InvalidState:
if
  • The volume is already unmounted.
  • The volume is inaccessible.
vim.fault.HostConfigFault:

for all other configuration failures.

vim.fault.ResourceInUse:
if
  • There is any VM registered on this volume.
  • 1 or more programs have I/O outstanding on this volume.
DeleteVmfsVolumeState(vmfsUuid):

For previously unmounted VMFS volume, remove the state information from host. VMFS volumes mount state is maintained by host.deleteVmfsVolumeState is part of the Unmount/Detach workflow used when the device will be permanently removed. See also UnmountVmfsVolume . If the VMFS volume is unmounted using unmountVmfsVolume, ESX maintains the state of VMFS volume. This API will remove the state from the host. If the underlying storage device is going to be un-provisioned on the array side, please detach the storage device. See also DetachScsiLun . since: vSphere API 5.0

Privilege:

Host.Config.Storage

Args:
vmfsUuid (str):

The VMFS UUID.

Returns:

None

Raises:

vim.fault.HostConfigFault:

for any configuration failures.

RescanVmfs():

Rescans for new Virtual Machine File Systems (VMFS). The RefreshStorageSystem method also performs a VMFS rescan. RescanVmfs may update the HostSystem . config . fileSystemVolume property. The Server performs asynchronous updates to the inventory. Use the PropertyCollector . WaitForUpdatesEx method to obtain the property changes.

Privilege:

Host.Config.Storage

Args:

Returns:

None

Raises:

vim.fault.HostConfigFault:

if configuration fails.

AttachVmfsExtent(vmfsPath, extent):

Extends a VMFS by attaching a disk partition as an extent.

Privilege:

Host.Config.Storage

Args:
vmfsPath (str):

The path of the VMFS to extend. See FileSystemMountInfo .

extent (vim.host.ScsiDisk.Partition):

A data object that describes the specification of a Disk partition.

Returns:

None

Raises:

vim.fault.NotFound:

if the VMFS cannot be found or is unmounted.

vim.fault.HostConfigFault:

for all other configuration failures.

vmodl.fault.InvalidArgument:

if the new extent is already used by another vmfs volume, does not exist, or is of an invalid partition type.

ExpandVmfsExtent(vmfsPath, extent):

Expands a VMFS extent as specified by the Disk partition specification. since: vSphere API 4.0

Privilege:

Host.Config.Storage

Args:
vmfsPath (str):

The path of the VMFS to expand. See FileSystemMountInfo .

extent (vim.host.ScsiDisk.Partition):

The disk partition corresponding to the extent to be expanded.

Returns:

None

Raises:

vim.fault.NotFound:

if the VMFS cannot be found or is unmounted.

vim.fault.HostConfigFault:

for all other configuration failures.

vmodl.fault.InvalidArgument:

if the extent is not part of the VMFS volume.

UpgradeVmfs(vmfsPath):

Upgrades the VMFS to the latest supported VMFS version .Prerequisite:All hosts that have mounted the volume must support the VMFS version to which the volume will be upgraded.

Privilege:

Host.Config.Storage

Args:
vmfsPath (str):

The path of the VMFS.

Returns:

None

Raises:

vim.fault.NotFound:

if the VMFS cannot be found or is unmounted.

vim.fault.HostConfigFault:

if the prerequisite is not satisfied or for all other configuration failures.

UpgradeVmLayout():

Iterates over all registered virtual machines. For each VM which .vmx file is located on the service console and all disks are available on VMFS3 or NAS, it will relocate the disks into directories if stored in the ROOT, and relocate the VMX file into the directory too. Events are logged for each virtual machine that is relocated.On ESXi systems, this operation has no effect.

Privilege:

Host.Config.Storage

Args:

Returns:

None

QueryUnresolvedVmfsVolume():

Get the list of unbound VMFS volumes. For sharing a volume across hosts, a VMFS volume is bound to its underlying block device storage. When a low level block copy is performed to copy or move the VMFS volume, the copied volume will be unbound. since: vSphere API 4.0

Privilege:

System.Read

Args:

Returns:
vim.host.UnresolvedVmfsVolume:

An array of unbound VMFS volumes.

ResolveMultipleUnresolvedVmfsVolumes(resolutionSpec):

Resignature or 'Force Mount' list of unbound VMFS volumes. To safely enable sharing of the volume across hosts, a VMFS volume is bound to its underlying block device storage. When a low level block copy is performed to copy or move the VMFS volume, the copied volume will be unbound. In order for the VMFS volume to be usable, a resolution operation is needed to determine whether the VMFS volume should be treated as a new volume or not and what extents compose that volume in the event there is more than one unbound volume.Resignature results in a new VMFS volume on the host. Operations performed at the StorageSystem interface apply only to a specific host. Hence, callers of this method are responsible for issuing rescan operations to detect the new VMFS volume on other hosts. Alternatively, callers that want VirtualCenter to handle rescanning the necessary hosts should use the DatastoreSystem interface.When user wants to keep the original Vmfs Uuid and mount it on the host, set the 'resolutionSpec.uuidResolution' to 'forceMounted' This is per-host operation. It will return an array of ResolutionResult describing success or failure associated with each specification. since: vSphere API 4.0

Privilege:

Host.Config.Storage

Args:
resolutionSpec (vim.host.UnresolvedVmfsResolutionSpec):

List of data object that describes what the disk extents to be used for creating the new VMFS volume.

Returns:
vim.host.UnresolvedVmfsResolutionResult:

A data object that represents the VMFS file system and return status value.

Raises:

vim.fault.HostConfigFault:

if batch operation fails on the host. Because the returned array of ResolutionResult contains the new VMFS volume or fault for each operation, as of vSphere API 5.x, we won't throw fault when batch operation fails.

ResolveMultipleUnresolvedVmfsVolumesEx(resolutionSpec):

Resignature or 'Force Mount' list of unbound VMFS volumes.To safely enable sharing of the volume across hosts, a VMFS volume is bound to its underlying block device storage. When a low level block copy is performed to copy or move the VMFS volume, the copied volume will be unbound. In order for the VMFS volume to be usable, a resolution operation is needed to determine whether the VMFS volume should be treated as a new volume or not and what extents compose that volume in the event there is more than one unbound volume.Resignature results in a new VMFS volume on the host. Operations performed at the HostStorageSystem interface apply only to a specific host. Hence, callers of this method are responsible for issuing rescan operations to detect the new VMFS volume on other hosts. Alternatively, callers that want VirtualCenter to handle rescanning the necessary hosts should use the HostDatastoreSystem interface.When user wants to keep the original VMFS UUID and mount it on the host, set the resolutionSpec.uuidResolution ( uuidResolution ) to forceMount . This is per-host operation.It will return an array of HostUnresolvedVmfsResolutionResult describing success or failure associated with each specification.This method behaves the same as ResolveMultipleUnresolvedVmfsVolumes except that it returns a task to support monitoring the operation. This is important for operations with large number of unresolved volumes which may take potentially dozens of minutes to complete. since: vSphere API 5.5

Privilege:

Host.Config.Storage

Args:
resolutionSpec (vim.host.UnresolvedVmfsResolutionSpec):

List of data object that describes what the disk extents to be used for creating the new VMFS volume.

Returns:

vim.Task:

Raises:

vim.fault.HostConfigFault:

if batch operation fails on the host. Because the returned array of ResolutionResult contains the new VMFS volume or fault for each operation, as of vSphere API 5.x, we won't throw fault when batch operation fails.

UnmountForceMountedVmfsVolume(vmfsUuid):

Unmount the 'forceMounted' Vmfs volume. When a low level block copy is performed to copy or move the VMFS volume, the copied volume is unresolved. For the VMFS volume to be usable, a resolution operation is applied. As part of resolution operation, user may decide to keep the original VMFS Uuid. Once the resolution is applied, the VMFS volume is mounted on the host for its use. User can unmount the VMFS volume if it is not being used by any registered VMs. since: vSphere API 4.0

Privilege:

Host.Config.Storage

Args:

vmfsUuid (str):

Returns:

None

Raises:

vim.fault.NotFound:

if VMFS Uuid is not found on the host.

vim.fault.HostConfigFault:

for all other configuration failures.

RescanHba(hbaDevice):

Issues a request to rescan a specific host bus adapter for new storage devices.

Privilege:

Host.Config.Storage

Args:
hbaDevice (str):

The device of the host bus adapter.

Returns:

None

Raises:

vim.fault.NotFound:

if the host bus adapter cannot be found.

vim.fault.HostConfigFault:

for all other configuration failures.

RescanAllHba():
Scans all host bus adapters to obtain the current list of devices and device topology. The RescanAllHba method looks for new devices, removed devices, and path changes.This method may update the following inventory elements:
Privilege:

Host.Config.Storage

Args:

Returns:

None

Raises:

vim.fault.HostConfigFault:

if rescan failed.

UpdateSoftwareInternetScsiEnabled(enabled):

Enables or disables Software iSCSI.

Privilege:

Host.Config.Storage

Args:
enabled (bool):

True to enable the iSCSI; false to disable it

Returns:

None

Raises:

vim.fault.HostConfigFault:

for any configuration failure.

UpdateInternetScsiDiscoveryProperties(iScsiHbaDevice, discoveryProperties):

Updates the Discovery properties for an iSCSI host bus adapter.

Privilege:

Host.Config.Storage

Args:
iScsiHbaDevice (str):

The device of the Internet SCSI HBA adapter.

discoveryProperties (vim.host.InternetScsiHba.DiscoveryProperties):

The discovery settings for this host bus adapter.

Returns:

None

Raises:

vim.fault.NotFound:

if the host bus adapter could not be found.

vim.fault.HostConfigFault:

for all other configuration failures.

UpdateInternetScsiAuthenticationProperties(iScsiHbaDevice, authenticationProperties, targetSet):

Updates the authentication properties for one or more targets or discovery addresses associated with an iSCSI host bus adapter.

Privilege:

Host.Config.Storage

Args:
iScsiHbaDevice (str):

The device of the Internet SCSI HBA adapter. associated with the target.

authenticationProperties (vim.host.InternetScsiHba.AuthenticationProperties):

The data object that represents the authentication settings to set.

targetSet (vim.host.InternetScsiHba.TargetSet, optional, since vSphere API 4.0 ):

The set the targets to configure. Optional, when obmitted will configura the authentication properties for the adapter instead.

Returns:

None

Raises:

vim.fault.NotFound:

if the host bus adapter could not be found.

vim.fault.HostConfigFault:

for all other configuration failures.

UpdateInternetScsiDigestProperties(iScsiHbaDevice, targetSet, digestProperties):

Updates the digest properties for the iSCSI host bus adapter or the discovery addresses and targets associated with it. since: vSphere API 4.0

Privilege:

Host.Config.Storage

Args:
iScsiHbaDevice (str):

The device of the Internet SCSI HBA adapter.

targetSet (vim.host.InternetScsiHba.TargetSet, optional):

The set the targets to configure. If not provided, the settings will be applied to the host bus adapter itself.

digestProperties (vim.host.InternetScsiHba.DigestProperties):

The data object that represents the digest settings to set.

Returns:

None

Raises:

vim.fault.NotFound:

if the host bus adapter could not be found.

vim.fault.HostConfigFault:

for all other configuration failures.

UpdateInternetScsiAdvancedOptions(iScsiHbaDevice, targetSet, options):

Updates the advanced options the iSCSI host bus adapter or the discovery addresses and targets associated with it. since: vSphere API 4.0

Privilege:

Host.Config.Storage

Args:
iScsiHbaDevice (str):

The device of the Internet SCSI HBA adapter.

targetSet (vim.host.InternetScsiHba.TargetSet, optional):

The set the targets to configure. If not provided, the settings will be applied to the host bus adapter itself.

options (vim.host.InternetScsiHba.ParamValue):

The list of options to set.

Returns:

None

Raises:

vim.fault.NotFound:

if the host bus adapter could not be found.

vim.fault.HostConfigFault:

for all other configuration failures.

UpdateInternetScsiIPProperties(iScsiHbaDevice, ipProperties):

Updates the IP properties for an iSCSI host bus adapter.

Privilege:

Host.Config.Storage

Args:
iScsiHbaDevice (str):

The device of the Internet SCSI HBA adapter.

ipProperties (vim.host.InternetScsiHba.IPProperties):

A data object representing the IP properties for the host bus adapter

Returns:

None

Raises:

vim.fault.NotFound:

if the host bus adapter could not be found.

vim.fault.HostConfigFault:

for all other configuration failures.

UpdateInternetScsiName(iScsiHbaDevice, iScsiName):

Updates the name of an iSCSI host bus adapter.

Privilege:

Host.Config.Storage

Args:
iScsiHbaDevice (str):

The current name of the Internet SCSI HBA adapter.

iScsiName (str):

The new name for the Internet SCSI HBA adapter

Returns:

None

Raises:

vim.fault.NotFound:

if the host bus adapter could not be found.

vim.fault.HostConfigFault:

for all other configuration failures.

UpdateInternetScsiAlias(iScsiHbaDevice, iScsiAlias):

Updates the alias of an iSCSI host bus adapter.

Privilege:

Host.Config.Storage

Args:
iScsiHbaDevice (str):

The device of the Internet SCSI HBA adapter.

iScsiAlias (str):

The new value for the alias of the adapter.

Returns:

None

Raises:

vim.fault.NotFound:

if the host bus adapter could not be found.

vim.fault.HostConfigFault:

for all other configuration failures.

AddInternetScsiSendTargets(iScsiHbaDevice, targets):

Adds Send Target entries to the host bus adapter discovery list. The DiscoveryProperties.sendTargetsDiscoveryEnabled flag must be set to true.

Privilege:

Host.Config.Storage

Args:
iScsiHbaDevice (str):

The device of the Internet SCSI HBA adapter.

targets (vim.host.InternetScsiHba.SendTarget):

An array of iSCSI send targets.

Returns:

None

Raises:

vim.fault.NotFound:

if the discovery list could not be found.

vim.fault.HostConfigFault:

for all other configuration failures.

RemoveInternetScsiSendTargets(iScsiHbaDevice, targets):

Removes Send Target entries from the host bus adapter discovery list. The DiscoveryProperty.sendTargetsDiscoveryEnabled must be set to true. If any of the targets provided as parameters are not found in the existing list, the other targets are removed and an exception is thrown.

Privilege:

Host.Config.Storage

Args:
iScsiHbaDevice (str):

The device of the Internet SCSI HBA adapter.

targets (vim.host.InternetScsiHba.SendTarget):

An array of iSCSI send targets to remove.

Returns:

None

Raises:

vim.fault.NotFound:

if at least one target was not found.

vim.fault.HostConfigFault:

for all other configuration failures.

AddInternetScsiStaticTargets(iScsiHbaDevice, targets):

Adds Static Target entries to the host bus adapter discovery list. The DiscoveryProperty.staticTargetDiscoveryEnabled must be set to true.

Privilege:

Host.Config.Storage

Args:
iScsiHbaDevice (str):

The device of the Internet SCSI HBA adapter.

targets (vim.host.InternetScsiHba.StaticTarget):

An array of iSCSI static targets to add.

Returns:

None

Raises:

vim.fault.NotFound:

if the host bus adaptor discovery list was not found.

vim.fault.HostConfigFault:

for all other configuration failures.

RemoveInternetScsiStaticTargets(iScsiHbaDevice, targets):

Removes static target entries from the host bus adapter discovery list. The DiscoveryProperty.staticTargetDiscoveryEnabled must be set to true. If any of the targets provided as parameters are not found in the existing list, the other targets are removed and an exception is thrown.

Privilege:

Host.Config.Storage

Args:
iScsiHbaDevice (str):

The device of the Internet SCSI HBA adapter.

targets (vim.host.InternetScsiHba.StaticTarget):

An array of iSCSI static targets to remove.

Returns:

None

Raises:

vim.fault.NotFound:

if at least one target was not found.

vim.fault.HostConfigFault:

for all other configuration failures.

EnableMultipathPath(pathName):

Enables a disabled path for a Logical Unit. Use the path name from HostMultipathStateInfoPath or HostMultipathInfoPath .

Privilege:

Host.Config.Storage

Args:
pathName (str):

The name of the path to enable.

Returns:

None

Raises:

vim.fault.NotFound:

if the LUN could not be found.

vim.fault.HostConfigFault:

for all other configuration failures.

DisableMultipathPath(pathName):

Disables an enabled path for a Logical Unit. Use the path name from HostMultipathStateInfoPath or HostMultipathInfoPath .

Privilege:

Host.Config.Storage

Args:
pathName (str):

The name of the path to disable.

Returns:

None

Raises:

vim.fault.NotFound:

if the LUN could not be found.

vim.fault.HostConfigFault:

for all other configuration failures.

SetMultipathLunPolicy(lunId, policy):

Updates the path selection policy for a Logical Unit. Use the LUN uuid from HostMultipathInfoLogicalUnit .

Privilege:

Host.Config.Storage

Args:
lunId (str):

The logical unit ID

policy (vim.host.MultipathInfo.LogicalUnitPolicy):

A data object that describes a path selection policy for the logical unit.

Returns:

None

Raises:

vim.fault.NotFound:

if the LUN could not be found.

vim.fault.HostConfigFault:

for all other configuration failures.

vmodl.fault.InvalidArgument:

if the policy is invalid.

QueryPathSelectionPolicyOptions():

Queries the set of path selection policy options. The set of policy options indicates what path selection policies can be used by a device managed by native multipathing. Devices managed through native multipathing are described in the HostMultipathInfo data object.Filtering capabilities are not currently present but may be added in the future. since: vSphere API 4.0

Privilege:

System.Read

Args:

Returns:
vim.host.PathSelectionPolicyOption:

The list of path selection policy descriptions that match the search criteria. Details about the policies will also be provided in accordance to the query specification.

Raises:

vim.fault.HostConfigFault:

for system configuration failures.

QueryStorageArrayTypePolicyOptions():

Queries the set of storage array type policy options. The set of policy options indicates what storage array type policies can be used by a device managed by native multipathing. Devices managed through native multipathing are described in the HostMultipathInfo data object.Filtering capabilities are not currently present but may be added in the future. since: vSphere API 4.0

Privilege:

System.Read

Args:

Returns:
vim.host.StorageArrayTypePolicyOption:

The list of storage array type policy descriptions.

Raises:

vim.fault.HostConfigFault:

for system configuration failures.

UpdateScsiLunDisplayName(lunUuid, displayName):

Update the mutable display name associated with a ScsiLun. The ScsiLun to be updated is identified using the specified uuid. since: vSphere API 4.0

Privilege:

Host.Config.Storage

Args:
lunUuid (str):

The uuid of the ScsiLun to update.

displayName (str):

The new name to assign to the ScsiLun object.

Returns:

None

Raises:

vim.fault.NotFound:

if the device could not be found.

vim.fault.HostConfigFault:

for all other configuration failures.

vim.fault.InvalidName:

if the name does not meet name restrictions such as an 80 character limit.

vim.fault.DuplicateName:

if the name does not name uniqueness restrictions. Name uniqueness restrictions will vary based on the context in which this method is invoked.When this method is invoked on a host directly, no uniqueness checks will be performed on the name.When this method is invoked on a VC server, uniqueness checks will be performed on the name. The uniqueness check will ensure that the name is unique with respect to the entire VC instance.

DetachScsiLun(lunUuid):

Disallow I/O issue to the specified ScsiLun. The ScsiLun is detached, i.e. administratively configured off until a subsequent attachScsiLun is performed, if the operation is successful. See AttachScsiLun .detachScsiLun is part of the Unmount / Detach workflow used when a device will be permanently removed. See also UnmountVmfsVolume . since: vSphere API 5.0

Privilege:

Host.Config.Storage

Args:
lunUuid (str):

The uuid of the ScsiLun device to detach.

Returns:

None

Raises:

vim.fault.NotFound:

if the device could not be found.

vim.fault.HostConfigFault:

for all other configuration failures.

vim.fault.InvalidState:
if
vim.fault.ResourceInUse:
if
  • This device is backing a Vm with a Raw Device Mapped Virtual Disk.
  • 1 or more programs have I/O outstanding on this device.
  • 1 or more mounted vmfs volumes have extents residing on this device.
  • The device is configured for use by the host e.g. diagnostic partition is configured on this device.
DeleteScsiLunState(lunCanonicalName):

For previously detached SCSI Lun, remove the state information from host. Detach SCSI Lun marks the device where I/Os are not allowed. Host still maintains the entry of this device and its state. If a LUN is detached using detachScsiLun, ESX will not automatically attach this LUN durng a rescan or after a reboot. See DetachScsiLun . Please note: The API takes 'canonicalName' of the ScsiLun object instead of the ScsiLun.uuid.See canonicalName since: vSphere API 5.0

Privilege:

Host.Config.Storage

Args:
lunCanonicalName (str):

The 'canonicalName' of the ScsiLun whose state needs to be deleted.See canonicalName

Returns:

None

Raises:

vim.fault.HostConfigFault:

for any configuration failures.See canonicalName

AttachScsiLun(lunUuid):

Allow I/O issue to the specified detached ScsiLun. The ScsiLun is administratively configured on, if the attach operation is successful. See DetachScsiLun .attachScsiLun is part of the Unmount, Detach workflow used when a device will be permanently removed. See also UnmountVmfsVolume . since: vSphere API 5.0

Privilege:

Host.Config.Storage

Args:
lunUuid (str):

The uuid of the ScsiLun to update.

Returns:

None

Raises:

vim.fault.NotFound:

if the device could not be found.

vim.fault.HostConfigFault:

for all other configuration failures.

vim.fault.InvalidState:
if
RefreshStorageSystem():
Obtains the latest host storage information related to storage devices, topology, and file systems. The ESX host updates its storage information asynchronously. The RefreshStorageSystem method obtains information from the host platform and it performs a rescan of VMFS volumes. It does not look for new devices.This method may update the following inventory elements:
Privilege:

Host.Config.Storage

Args:

Returns:

None

DiscoverFcoeHbas(fcoeSpec):

Initiates FCoE discovery using the given FcoeSpecification. Upon success, discovered VNPorts will have registered with the system as FCoE HBAs. since: vSphere API 5.0

Privilege:

Host.Config.Storage

Args:

fcoeSpec (vim.host.FcoeConfig.FcoeSpecification):

Returns:

None

Raises:

vim.fault.FcoeFaultPnicHasNoPortSet:

vim.fault.FcoeFaultPnicHasNoPortSet

vim.fault.HostConfigFault:

if the host is unable to issue FCoE discovery.

vim.fault.NotFound:

if the given HBA could not be found.

vmodl.fault.InvalidArgument:

if any parameter in the given FcoeSpecification is invalid.

MarkForRemoval(hbaName, remove):

Mark or unmark the given FCoE HBA for removal from the host system. Marking an FCoE HBA for removal will result in the HBA not being discovered upon host reboot. Until reboot, the HBA remains visible in the storage topology. since: vSphere API 5.0

Privilege:

Host.Config.Storage

Args:

hbaName (str):

remove (bool):

Returns:

None

Raises:

vim.fault.NotFound:

if the given HBA could not be found.

vim.fault.HostConfigFault:

if the host does not support removing the given HBA.

vmodl.fault.InvalidArgument:

if the given HBA is not an FCoE HBA.

FormatVffs(createSpec):

Format a new VFFS on a SSD disk since: vSphere API 5.5

Privilege:

Host.Config.Storage

Args:
createSpec (vim.host.VffsVolume.Specification):

A data object that describes the VFFS volume creation specification.

Returns:
vim.host.VffsVolume:

A data object that represents the VFFS file system.

Raises:

vim.fault.AlreadyExists:

if the volume name is already being used by another volume on the host.

vim.fault.HostConfigFault:

for all other configuration failures.

vim.fault.ResourceInUse:

VFFS volume is being used.

vmodl.fault.InvalidArgument:

if VFFS version is invalid, the SSD disk does not exist or is of an invalid type.

ExtendVffs(vffsPath, devicePath, spec):

Extends a VFFS by attaching a SSD.See devicePath since: vSphere API 5.5

Privilege:

Host.Config.Storage

Args:
vffsPath (str):

The path of the VFFS to extend. See FileSystemMountInfo .See devicePath

devicePath (str):

Device path of the SSD disk.See devicePath

spec (vim.host.DiskPartitionInfo.Specification, optional):

A data object that describes the SSD disk partition information. If this property is not provided, partition information will be computed and generated.See devicePath

Returns:

None

Raises:

vim.fault.NotFound:

if the VFFS cannot be found or is unmounted.See devicePath

vim.fault.HostConfigFault:

for all other configuration failures.See devicePath

vim.fault.ResourceInUse:

VFFS volume is being used.See devicePath

vmodl.fault.InvalidArgument:

if the new SSD is already used by another VFFS volume, does not exist, or is of an invalid partition type.See devicePath

DestroyVffs(vffsPath):

Destroy a VFFS volume. since: vSphere API 5.5

Privilege:

Host.Config.Storage

Args:
vffsPath (str):

The path of the VFFS to destroy. See FileSystemMountInfo .

Returns:

None

Raises:

vim.fault.NotFound:

if the VFFS cannot be found or is unmounted.

vim.fault.HostConfigFault:

for all other configuration failures.

vim.fault.ResourceInUse:

VFFS volume is being used.

MountVffsVolume(vffsUuid):

Mount the unmounted VFFS volume. See UnmountVffsVolume .mountVffsVolume is part of the Unmount / Detach workflow used when a device will be permanently removed. See also DetachScsiLun . since: vSphere API 5.5

Privilege:

Host.Config.Storage

Args:

vffsUuid (str):

Returns:

None

Raises:

vim.fault.NotFound:

if VFFS uuid is not found on the host.

vim.fault.InvalidState:
if
  • The volume is already mounted.
  • The volume is inaccessible.
vim.fault.HostConfigFault:

for all other configuration failures.

vim.fault.ResourceInUse:

VFFS volume is being used.

UnmountVffsVolume(vffsUuid):

Unmount the VFFS volume. An unmounted volume cannot be used for any filesystem operation requiring I/O. In contrast to removal, this operation does not destroy or alter partitions on which VFFS volumes reside. The mountState will be persisted across filesystem rescans and host reboots. See MountVffsVolume .unmountVffsVolume is part of the Unmount / Detach workflow used when a device will be permanently removed. See also DetachScsiLun . since: vSphere API 5.5

Privilege:

Host.Config.Storage

Args:

vffsUuid (str):

Returns:

None

Raises:

vim.fault.NotFound:

if VFFS uuid is not found on the host.

vim.fault.InvalidState:
if
  • The volume is already unmounted.
  • The volume is inaccessible.
vim.fault.HostConfigFault:

for all other configuration failures.

vim.fault.ResourceInUse:
if
  • 1 or more programs have I/O outstanding on this volume.
DeleteVffsVolumeState(vffsUuid):

For previously unmounted VFFS volume, remove the state information from host. VFFS volumes mount state is maintained by host.deleteVffsVolumeState is part of the Unmount/Detach workflow used when the device will be permanently removed. See also UnmountVffsVolume . If the VFFS volume is unmounted using unmountVffsVolume, ESX maintains the state of VFFS volume. This API will remove the state from the host. If the underlying storage device is going to be un-provisioned on the array side, please detach the storage device. See also DetachScsiLun . since: vSphere API 5.5

Privilege:

Host.Config.Storage

Args:
vffsUuid (str):

The VFFS UUID.

Returns:

None

Raises:

vim.fault.HostConfigFault:

for any configuration failures.

RescanVffs():

Rescans for new VFFS. The RefreshStorageSystem method also performs a VFFS rescan. RescanVffs may update the HostSystem . config . fileSystemVolume property. The Server performs asynchronous updates to the inventory. Use the PropertyCollector . WaitForUpdatesEx method to obtain the property changes. since: vSphere API 5.5

Privilege:

Host.Config.Storage

Args:

Returns:

None

Raises:

vim.fault.HostConfigFault:

if configuration fails.

QueryAvailableSsds(vffsPath):

Query the list SSD disks that can be used to contain a VFFS volume. If the optional parameter name is supplied, queries for the SSD disks that can be used to contain extents of the specified VFFS volume. Otherwise, the method retrieves the SSD disks that can be used to contain the new VFFS volume.This operation will filter out SSD disks that are currently in use by an existing VFFS volume. since: vSphere API 5.5

Privilege:

Host.Config.Storage

Args:
vffsPath (str, optional):

The path of the VFFS to extend. See FileSystemMountInfo .

Returns:
vim.host.ScsiDisk:

An array of data objects descrbing SSD disks.

Raises:

vim.fault.NotFound:

if the named VFFS volume is not found.

vim.fault.HostConfigFault:

if unable to query disk information.

vmodl.fault.InvalidArgument: