.. _str: https://docs.python.org/2/library/stdtypes.html
.. _int: https://docs.python.org/2/library/stdtypes.html
.. _isolated: ../../../vim/dvs/VmwareDistributedVirtualSwitch/PvlanPortType.rst#isolated
.. _community: ../../../vim/dvs/VmwareDistributedVirtualSwitch/PvlanPortType.rst#community
.. _pvlanType: ../../../vim/dvs/VmwareDistributedVirtualSwitch/PvlanMapEntry.rst#pvlanType
.. _promiscuous: ../../../vim/dvs/VmwareDistributedVirtualSwitch/PvlanPortType.rst#promiscuous
.. _ipfixEnabled: ../../../vim/dvs/VmwareDistributedVirtualSwitch/VmwarePortConfigPolicy.rst#ipfixEnabled
.. _primaryVlanId: ../../../vim/dvs/VmwareDistributedVirtualSwitch/PvlanMapEntry.rst#primaryVlanId
.. _vSphere API 4.0: ../../../vim/version.rst#vimversionversion5
.. _secondaryVlanId: ../../../vim/dvs/VmwareDistributedVirtualSwitch/PvlanMapEntry.rst#secondaryVlanId
.. _VMwareDVSPvlanMapEntry: ../../../vim/dvs/VmwareDistributedVirtualSwitch/PvlanMapEntry.rst
.. _LinkDiscoveryProtocolConfig: ../../../vim/host/LinkDiscoveryProtocolConfig.rst
.. _vim.host.LinkDiscoveryProtocolConfig: ../../../vim/host/LinkDiscoveryProtocolConfig.rst
.. _vim.DistributedVirtualSwitch.ConfigSpec: ../../../vim/DistributedVirtualSwitch/ConfigSpec.rst
.. _vim.dvs.VmwareDistributedVirtualSwitch.IpfixConfig: ../../../vim/dvs/VmwareDistributedVirtualSwitch/IpfixConfig.rst
.. _vim.dvs.VmwareDistributedVirtualSwitch.PvlanConfigSpec: ../../../vim/dvs/VmwareDistributedVirtualSwitch/PvlanConfigSpec.rst
.. _vim.dvs.VmwareDistributedVirtualSwitch.VspanConfigSpec: ../../../vim/dvs/VmwareDistributedVirtualSwitch/VspanConfigSpec.rst
vim.dvs.VmwareDistributedVirtualSwitch.ConfigSpec
=================================================
This class defines the VMware specific configuration for DistributedVirtualSwitch.
:extends: vim.DistributedVirtualSwitch.ConfigSpec_
:since: `vSphere API 4.0`_
Attributes:
pvlanConfigSpec (`vim.dvs.VmwareDistributedVirtualSwitch.PvlanConfigSpec`_, optional):
The PVLAN configuration specification.A `VMwareDVSPvlanMapEntry`_ that has the same value for `primaryVlanId`_ and `secondaryVlanId`_ is referred to as a primary PVLAN entry. Otherwise, the `VMwareDVSPvlanMapEntry`_ is referred to as a secondary PVLAN entry.The `pvlanType`_ of a primary PVLAN entry must be `promiscuous`_ . A secondary PVLAN entry can have a `pvlanType`_ of either `community`_ or `isolated`_ .Primary PVLAN entries must be explicitly added. If there is no primary PVLAN entry corresponding to the `primaryVlanId`_ of a secondary PVLAN entry, a fault is thrown.While deleting a primary PVLAN entry, any associated secondary PVLAN entries must be explicitly deleted.
vspanConfigSpec (`vim.dvs.VmwareDistributedVirtualSwitch.VspanConfigSpec`_, optional):
The Distributed Port Mirroring configuration specification. The VSPAN sessions in the array cannot be of the same key.
maxMtu (`int`_, optional):
The maximum MTU in the switch.
linkDiscoveryProtocolConfig (`vim.host.LinkDiscoveryProtocolConfig`_, optional):
See `LinkDiscoveryProtocolConfig`_ .
ipfixConfig (`vim.dvs.VmwareDistributedVirtualSwitch.IpfixConfig`_, optional):
Configuration for ipfix monitoring of the switch traffic. This must be set before ipfix monitoring can be enabled for the switch, or for any portgroup or port of the switch.See `ipfixEnabled`_
lacpApiVersion (`str`_, optional):
The Link Aggregation Control Protocol group version in the switch. See LacpApiVersion for valid values.