
This external documentation for pyVmomi was generated using Googly Docs (aka Google Standard Documentation) which renders very cleanly in GitHub. Internal documentation for a class should be done in Sphinx format because tools like pyCharm and Eclipse can use that documentation as a hint for code completion. Note: External docs as Googly Docs, internal docs as Sphinx. Closes bug#15
39 lines
2.0 KiB
ReStructuredText
39 lines
2.0 KiB
ReStructuredText
.. _int: https://docs.python.org/2/library/stdtypes.html
|
|
|
|
.. _high: ../../vim/SharesInfo/Level.rst#high
|
|
|
|
.. _bool: https://docs.python.org/2/library/stdtypes.html
|
|
|
|
.. _normal: ../../vim/SharesInfo/Level.rst#normal
|
|
|
|
.. _shares: ../../vim/dvs/NetworkResourcePool/AllocationInfo.rst#shares
|
|
|
|
.. _SharesLevel: ../../vim/SharesInfo/Level.rst
|
|
|
|
.. _vSphere API 5.0: ../../vim/version.rst#vimversionversion7
|
|
|
|
.. _vmodl.DynamicData: ../../vmodl/DynamicData.rst
|
|
|
|
.. _DVSNetworkResourcePoolAllocationInfo: ../../vim/dvs/NetworkResourcePool/AllocationInfo.rst
|
|
|
|
|
|
vim.DistributedVirtualSwitch.NetworkResourceManagementCapability
|
|
================================================================
|
|
Dataobject representing the feature capabilities of network resource management supported by the vSphere Distributed Switch.
|
|
:extends: vmodl.DynamicData_
|
|
:since: `vSphere API 5.0`_
|
|
|
|
Attributes:
|
|
networkResourceManagementSupported (`bool`_):
|
|
|
|
Indicates whether network I/O control is supported on the vSphere Distributed Switch. Network I/O control is supported in vSphere Distributed Switch Version 4.1 or later.
|
|
networkResourcePoolHighShareValue (`int`_):
|
|
|
|
High share level ( `SharesLevel`_ . `high`_ ) for `DVSNetworkResourcePoolAllocationInfo`_ . `shares`_ .ThenetworkResourcePoolHighshareValueproperty implicitly defines the legal range of share values to be between 1 and this value. This property also defines values for other level types, such as `normal`_ being one half of this value and `low`_ being one fourth of this value. This feature is supported in vSphere Distributed Switch Version 4.1 or later.
|
|
qosSupported (`bool`_):
|
|
|
|
Indicates whether Qos Tag(802.1p priority tag)is supported on the vSphere Distributed Switch. Qos Tag is supported in vSphere Distributed Switch Version 5.0 or later.
|
|
userDefinedNetworkResourcePoolsSupported (`bool`_):
|
|
|
|
Indicates whether the switch supports creating user defined resource pools. This feature is supported in vSphere Distributed Switch Version 5.0 or later.
|