Fixes RST documents to include list mark up when appropriate. closes: https://github.com/vmware/pyvmomi/issues/76
63 lines
2.2 KiB
ReStructuredText
63 lines
2.2 KiB
ReStructuredText
.. _int: https://docs.python.org/2/library/stdtypes.html
|
|
|
|
.. _str: https://docs.python.org/2/library/stdtypes.html
|
|
|
|
.. _bool: https://docs.python.org/2/library/stdtypes.html
|
|
|
|
.. _vim.KeyValue: ../../vim/KeyValue.rst
|
|
|
|
.. _vSphere API 4.0: ../../vim/version.rst#vimversionversion5
|
|
|
|
.. _vmodl.DynamicData: ../../vmodl/DynamicData.rst
|
|
|
|
.. _vim.host.PhysicalNic: ../../vim/host/PhysicalNic.rst
|
|
|
|
.. _vim.host.HostProxySwitch.Specification: ../../vim/host/HostProxySwitch/Specification.rst
|
|
|
|
.. _vim.host.HostProxySwitch.HostLagConfig: ../../vim/host/HostProxySwitch/HostLagConfig.rst
|
|
|
|
|
|
vim.host.HostProxySwitch
|
|
========================
|
|
The HostProxySwitch is a software entity which represents the component of a DistributedVirtualSwitch on a particular host.
|
|
:extends: vmodl.DynamicData_
|
|
:since: `vSphere API 4.0`_
|
|
|
|
Attributes:
|
|
dvsUuid (`str`_):
|
|
|
|
The uuid of the DistributedVirtualSwitch that the HostProxySwitch is a part of.
|
|
dvsName (`str`_):
|
|
|
|
The name of the DistributedVirtualSwitch that the HostProxySwitch is part of.
|
|
key (`str`_):
|
|
|
|
The proxy switch key.
|
|
numPorts (`int`_):
|
|
|
|
The number of ports that this switch currently has.
|
|
configNumPorts (`int`_, optional):
|
|
|
|
The configured number of ports that this switch has. If configured number of ports is changed, a host reboot is required for the new value to take effect.
|
|
numPortsAvailable (`int`_):
|
|
|
|
The number of ports that are available on this virtual switch.
|
|
uplinkPort ([`vim.KeyValue`_], optional):
|
|
|
|
The list of ports that can be potentially used by physical nics. This property contains the keys and names of such ports.
|
|
mtu (`int`_, optional):
|
|
|
|
The maximum transmission unit (MTU) associated with this switch in bytes.
|
|
pnic ([`vim.host.PhysicalNic`_], optional):
|
|
|
|
The set of physical network adapters associated with this switch.
|
|
spec (`vim.host.HostProxySwitch.Specification`_):
|
|
|
|
The specification of the switch.
|
|
hostLag ([`vim.host.HostProxySwitch.HostLagConfig`_], optional):
|
|
|
|
The Link Aggregation Control Protocol group and Uplink ports in the group.
|
|
networkReservationSupported (`bool`_, optional):
|
|
|
|
Indicates whether network reservation is supported on this switch
|