OSHA
|
|
==================
|
|
|
|
Osha, Openstack Compute node High Available provides compute node high availability for OpenStack.
|
|
Simply Osha monitors all compute nodes running in a cloud deployment and if there is any failure
|
|
in one of the compute nodes osha will fence this compute node then osha will try to evacuate all
|
|
running instances on this compute node, finally Osha will notify all users who have workload/instances
|
|
running on this compute node as well as will notify the cloud administrators.
|
|
|
|
Osha has a pluggable architecture so it can be used with:
|
|
|
|
1. Any monitoring system to monitor the compute nodes (currently we support only native openstack services status)
|
|
2. Any fencing driver (currently supports IPMI, libvirt, ...)
|
|
3. Any evacuation driver (currently supports evacuate api call, may be migrate ??)
|
|
4. Any notification system (currently supports email based notifications, ...)
|
|
|
|
just by adding a simple plugin and adjust the configuration file to use this
|
|
plugin or in future a combination of plugins if required
|
|
|
|
Osha should run in the control plane, however the architecture supports different scenarios.
|
|
For running osha under high availability mode, it should run with active passive mode.
|
|
|
|
|
|
-----------------
|
|
How it works
|
|
-----------------
|
|
|
|
Starting Osha
|
|
1. Osha Monitoring manager is going to load the required monitoring driver according to the configuration
|
|
2. Osha will query the monitoring system to check if it considers any compute nodes to be down ?
|
|
3.1. if no, Osha will exit displaying No failed nodes
|
|
3.2. if yes, Osha will call the fencing manager to fence the failed compute node
|
|
4. Fencing manager will load the correct fencer according to the configuration
|
|
5. once the compute node is fenced and is powered off now we will start the evacuation process
|
|
6. Osha will load the correct evacuation driver
|
|
7. Osha will evacuate all instances to another computes
|
|
8. Once the evacuation process completed, Osha will call the notification manager
|
|
9. The notification manager will load the correct driver based on the configurations
|
|
10. Osha will start the notification process ...
|