![Dmitry Tantsur](/assets/img/avatar_default.png)
This change adds a new introspection data field 'configuration' with two lists: managers and collectors. Change-Id: Ice0d7e6ecff3f319bc3a4f41617059fd6914e31c
230 lines
8.7 KiB
ReStructuredText
230 lines
8.7 KiB
ReStructuredText
How it works
|
|
============
|
|
|
|
Integration with Ironic
|
|
-----------------------
|
|
|
|
Compatible Deploy Drivers
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Agent Deploy Driver
|
|
<<<<<<<<<<<<<<<<<<<
|
|
IPA works with the agent Deploy driver in Ironic to provision nodes. Starting
|
|
with ironic-python-agent running on a ramdisk on an unprovisioned node,
|
|
Ironic makes API calls to ironic-python-agent to provision the machine. This
|
|
allows for greater control and flexibility of the entire deployment process.
|
|
|
|
PXE Deploy Driver
|
|
<<<<<<<<<<<<<<<<<
|
|
IPA may also be used with the original Ironic pxe driver as of the Kilo
|
|
OpenStack Ironic release.
|
|
|
|
Configuring Deploy Drivers
|
|
<<<<<<<<<<<<<<<<<<<<<<<<<<
|
|
For information on how to install and configure Ironic drivers, including
|
|
drivers for IPA, see the Ironic drivers documentation [0]_.
|
|
|
|
Lookup
|
|
~~~~~~
|
|
On startup, the agent performs a lookup in Ironic to determine its node UUID
|
|
by sending a hardware profile to the Ironic lookup endpoint:
|
|
``/v1/lookup``.
|
|
|
|
Heartbeat
|
|
~~~~~~~~~
|
|
After successfully looking up its node, the agent heartbeats via
|
|
``/v1/heartbeat/{node_ident}`` every N seconds, where
|
|
N is the Ironic conductor's agent.heartbeat_timeout value multiplied by a
|
|
number between .3 and .6.
|
|
|
|
For example, if your conductor's ironic.conf contains::
|
|
|
|
[agent]
|
|
heartbeat_timeout = 60
|
|
|
|
IPA will heartbeat between every 20 and 36 seconds. This is to ensure jitter
|
|
for any agents reconnecting after a network or API disruption.
|
|
|
|
After the agent heartbeats, the conductor performs any actions needed against
|
|
the node, including querying status of an already run command. For example,
|
|
initiating in-band cleaning tasks or deploying an image to the node.
|
|
|
|
Inspection
|
|
~~~~~~~~~~
|
|
IPA can conduct hardware inspection on start up and post data to the `Ironic
|
|
Inspector`_. Edit your default PXE/iPXE configuration or IPA options
|
|
baked in the image, and set ``ipa-inspection-callback-url`` to the
|
|
full endpoint of Ironic Inspector, for example::
|
|
|
|
ipa-inspection-callback-url=http://IP:5050/v1/continue
|
|
|
|
Make sure your DHCP environment is set to boot IPA by default.
|
|
|
|
For the cases where the infrastructure operator and cloud user are the same,
|
|
an additional tool exists that can be installed alongside the agent inside
|
|
a running instance. This is the ``ironic-collect-introspection-data``
|
|
command which allows for a node in ``ACTIVE`` state to publish updated
|
|
introspection data to ironic-inspector. This ability requires ironic-inspector
|
|
to be configured with ``[processing]permit_active_introspection`` set to
|
|
``True``. For example::
|
|
|
|
ironic-collect-introspection-data --inspection_callback_url http://IP:5050/v1/continue
|
|
|
|
Alternatively, this command may also be used with multicast DNS
|
|
functionality to identify the `Ironic Inspector`_ service endpoint.
|
|
For example::
|
|
|
|
ironic-collect-introspection-data --inspection_callback_url mdns
|
|
|
|
An additional daemon mode may be useful for some operators who wish to receive
|
|
regular updates, in the form of the ``[DEFAULT]introspection_daemon`` boolean
|
|
configuration option.
|
|
For example::
|
|
|
|
ironic-collect-introspection-data --inspection_callback_url mdns --introspection_daemon
|
|
|
|
The above command will attempt to connect to introspection and will then enter
|
|
a loop to publish every 300 seconds. This can be tuned with the
|
|
``[DEFAULT]introspection_daemon_post_interval`` configuration option.
|
|
|
|
.. _Ironic Inspector: https://docs.openstack.org/ironic-inspector/
|
|
|
|
Inspection Data
|
|
<<<<<<<<<<<<<<<
|
|
As part of the inspection process, data is collected on the machine and sent
|
|
back to `Ironic Inspector`_ for storage. It can be accessed via the
|
|
`introspection data API`_.
|
|
|
|
The exact format of the data depends on the enabled *collectors*, which can be
|
|
configured using the ``ipa-inspection-collectors`` kernel parameter. Each
|
|
collector appends information to the resulting JSON object. The in-tree
|
|
collectors are:
|
|
|
|
``default``
|
|
The default enabled collectors. Collects the following keys:
|
|
|
|
* ``inventory`` - `Hardware Inventory`_.
|
|
* ``root_disk`` - The default root device for this machine, which will be
|
|
used for deployment if root device hints are not provided.
|
|
* ``configuration`` - Inspection configuration, an object with two keys:
|
|
|
|
* ``collectors`` - List of enabled collectors.
|
|
* ``managers`` - List of enabled :ref:`Hardware Managers`: items with
|
|
keys ``name`` and ``version``.
|
|
|
|
* ``boot_interface`` - Deprecated, use the
|
|
``inventory.boot.pxe_interface`` field.
|
|
|
|
``logs``
|
|
Collect system logs. To yield useful results it must always go last in the
|
|
list of collectors. Provides one key:
|
|
|
|
* ``logs`` - base64 encoded tarball with various logs.
|
|
|
|
``pci-devices``
|
|
Collects the list of PCI devices. Provides one key:
|
|
|
|
* ``pci_devices`` - list of objects with keys ``vendor_id`` and
|
|
``product_id``.
|
|
|
|
``extra-hardware``
|
|
Collects a vast list of facts about the systems, using the hardware_
|
|
library, which is a required dependency for this collector. Adds one key:
|
|
|
|
* ``data`` - raw data from the ``hardware-collect`` utility. Is a list of
|
|
lists with 4 items each. It is recommended to use this collector together
|
|
with the ``extra_hardware`` processing hook on the `Ironic Inspector`_
|
|
side to convert it to a nested dictionary in the ``extra`` key.
|
|
|
|
If ``ipa-inspection-benchmarks`` is set, the corresponding benchmarks are
|
|
executed and their result is also provided.
|
|
|
|
``dmi-decode``
|
|
Collects information from ``dmidecode``. Provides one key:
|
|
|
|
* ``dmi`` DMI information in three keys: ``bios``, ``cpu`` and ``memory``.
|
|
|
|
.. TODO(dtantsur): figure out details
|
|
|
|
``numa-topology``
|
|
Collects NUMA_ topology information. Provides one key:
|
|
|
|
* ``numa_topology`` with three nested keys:
|
|
|
|
* ``ram`` - list of objects with keys ``numa_node`` (node ID) and
|
|
``size_kb``.
|
|
* ``cpus`` - list of objects with keys ``cpu`` (CPU ID), ``numa_node``
|
|
(node ID) and ``thread_siblings`` (list of sibling threads).
|
|
* ``nics`` - list of objects with keys ``name`` (NIC name) and
|
|
``numa_node`` (node ID).
|
|
|
|
.. _introspection data API: https://docs.openstack.org/ironic-inspector/latest/user/http-api.html#get-introspection-data
|
|
.. _hardware: https://pypi.org/project/hardware/
|
|
.. _NUMA: https://en.wikipedia.org/wiki/Non-uniform_memory_access
|
|
|
|
Hardware Inventory
|
|
------------------
|
|
IPA collects various hardware information using its
|
|
:doc:`Hardware Managers <../contributor/hardware_managers>`,
|
|
and sends it to Ironic on lookup and to Ironic Inspector on Inspection_.
|
|
|
|
The exact format of the inventory depends on the hardware manager used.
|
|
Here is the basic format expected to be provided by all hardware managers.
|
|
The inventory is a dictionary (JSON object), containing at least the following
|
|
fields:
|
|
|
|
``cpu``
|
|
CPU information: ``model_name``, ``frequency``, ``count``,
|
|
``architecture`` and ``flags``.
|
|
|
|
``memory``
|
|
RAM information: ``total`` (total size in bytes), ``physical_mb``
|
|
(physically installed memory size in MiB, optional).
|
|
|
|
.. note::
|
|
The difference is that the latter includes the memory region reserved
|
|
by the kernel and is always slightly bigger. It also matches what
|
|
the Nova flavor would contain for this node and thus is used by the
|
|
inspection process instead of ``total``.
|
|
|
|
``bmc_address``
|
|
IPv4 address of the node's BMC (aka IPMI v4 address), optional.
|
|
|
|
``bmc_v6address``
|
|
IPv6 address of the node's BMC (aka IPMI v6 address), optional.
|
|
|
|
``disks``
|
|
list of disk block devices with fields: ``name``, ``model``,
|
|
``size`` (in bytes), ``rotational`` (boolean), ``wwn``, ``serial``,
|
|
``vendor``, ``wwn_with_extension``, ``wwn_vendor_extension``, ``hctl``
|
|
and ``by_path`` (the full disk path, in the form
|
|
``/dev/disk/by-path/<rest-of-path>``).
|
|
|
|
``interfaces``
|
|
list of network interfaces with fields: ``name``, ``mac_address``,
|
|
``ipv4_address``, ``lldp``, ``vendor``, ``product``, and optionally
|
|
``biosdevname``(BIOS given NIC name). If configuration option
|
|
``collect_lldp`` is set to True the ``lldp`` field will be populated
|
|
by a list of type-length-value(TLV) fields retrieved using the
|
|
Link Layer Discovery Protocol (LLDP).
|
|
|
|
``system_vendor``
|
|
system vendor information from SMBIOS as reported by ``dmidecode``:
|
|
``product_name``, ``serial_number`` and ``manufacturer``.
|
|
|
|
``boot``
|
|
boot information with fields: ``current_boot_mode`` (boot mode used for
|
|
the current boot - BIOS or UEFI) and ``pxe_interface`` (interface used
|
|
for PXE booting, if any).
|
|
|
|
``hostname``
|
|
hostname for the system
|
|
|
|
.. note::
|
|
This is most likely to be set by the DHCP server. Could be localhost
|
|
if the DHCP server does not set it.
|
|
|
|
References
|
|
==========
|
|
.. [0] Enabling Drivers - https://docs.openstack.org/ironic/latest/admin/drivers/ipa.html
|