iLO Virtual Media IPA Deploy Driver
Add ability to provision proliant baremetal nodes (having iLO4 and beyond) by booting the baremetal node with virtual media and using IPA to deploy the image. Change-Id: Ic2856a349f57dd15126740c128a2e24b7270810a
This commit is contained in:
parent
72624a540c
commit
820506329a
127
specs/juno/ilo-virtualmedia-ipa.rst
Normal file
127
specs/juno/ilo-virtualmedia-ipa.rst
Normal file
@ -0,0 +1,127 @@
|
||||
..
|
||||
This work is licensed under a Creative Commons Attribution 3.0 Unported
|
||||
License.
|
||||
|
||||
http://creativecommons.org/licenses/by/3.0/legalcode
|
||||
|
||||
=====================
|
||||
iLO IPA Deploy Driver
|
||||
=====================
|
||||
|
||||
https://blueprints.launchpad.net/ironic/+spec/ilo-virtualmedia-ipa
|
||||
|
||||
Add ability to provision proliant baremetal nodes (having iLO4 and beyond)
|
||||
by booting the baremetal node with virtual media and using IPA to deploy the
|
||||
image.
|
||||
|
||||
Problem description
|
||||
===================
|
||||
IPA project provides a more powerful ramdisk for doing deploy from the
|
||||
conductor node. But IPA has the following issues:
|
||||
|
||||
- Some customers don't prefer PXE protocol in their environment because of
|
||||
the following issues:
|
||||
|
||||
+ PXE uses TFTP to transfer the files which is unreliable because it uses
|
||||
UDP.
|
||||
+ PXE is not suited for some network topologies where the relaying of PXE
|
||||
requests might be required in routers to enable PXE working for the whole
|
||||
network.
|
||||
- Deployers require an extra tftp service to be running on the conductor node.
|
||||
- Currently the admin token required to call node's vendorpassthru cannot be
|
||||
transmitted securely to the baremetal node.
|
||||
|
||||
Proposed change
|
||||
===============
|
||||
The below review introduced a new mechanism for booting proliant machines with
|
||||
virtual media.
|
||||
http://specs.openstack.org/openstack/ironic-specs/specs/juno/ironic-ilo-virtualmedia-driver.html
|
||||
|
||||
The methods ``setup_virtual_media_boot`` introduced in the above review can be
|
||||
used to boot up a baremetal node with the deploy ISO image. A new class
|
||||
``IloVirtualMediaAgentDeploy`` can be added which will setup the machine to
|
||||
be booted with virtual media instead of PXE.
|
||||
|
||||
The vendor interface ``AgentVendorInterface`` can be reused to continue the
|
||||
deploy and complete it.
|
||||
|
||||
This change will also enable the admin token to be handed off securely to the
|
||||
baremetal node through OOB channel over virtual media.
|
||||
|
||||
Alternatives
|
||||
------------
|
||||
The proliant machines can continue to work booting the agent ramdisk with PXE.
|
||||
|
||||
Data model impact
|
||||
-----------------
|
||||
One new parameter ``deploy_iso`` will be used in driver_info to boot up the
|
||||
node for deploy. ``deploy_iso`` will contain the glance UUID of bootable
|
||||
ISO built with agent ramdisk.
|
||||
|
||||
REST API impact
|
||||
---------------
|
||||
None.
|
||||
|
||||
Driver API impact
|
||||
-----------------
|
||||
None.
|
||||
|
||||
Nova driver impact
|
||||
------------------
|
||||
None.
|
||||
|
||||
Security impact
|
||||
---------------
|
||||
None.
|
||||
|
||||
Other end user impact
|
||||
---------------------
|
||||
None.
|
||||
|
||||
Scalability impact
|
||||
------------------
|
||||
None.
|
||||
|
||||
Performance Impact
|
||||
------------------
|
||||
None.
|
||||
|
||||
Other deployer impact
|
||||
---------------------
|
||||
This method of deploy no longer requires an extra service (like tftp service
|
||||
in case of pxe driver) to be running on the conductor node.
|
||||
|
||||
Developer impact
|
||||
----------------
|
||||
None.
|
||||
|
||||
Implementation
|
||||
==============
|
||||
|
||||
Assignee(s)
|
||||
-----------
|
||||
Primary assignee:
|
||||
rameshg87
|
||||
|
||||
Work Items
|
||||
----------
|
||||
* Add ``IloVirtualMediaAgentDeploy`` which implements base.DeployInterface.
|
||||
|
||||
Dependencies
|
||||
============
|
||||
None.
|
||||
|
||||
Testing
|
||||
=======
|
||||
Unit tests will be added for all the code. Tempest tests for this will be
|
||||
considered later.
|
||||
|
||||
Documentation Impact
|
||||
====================
|
||||
The procedure for configuring the proliant baremetal node will need to be
|
||||
documented. This will be documented in rst format in doc/ directory in ironic
|
||||
source tree. The contents of this file can be put in ironic wiki as well.
|
||||
|
||||
References
|
||||
==========
|
||||
None.
|
Loading…