@@ -0,0 +1,581 @@
|
|
|
|
|
.. meta::
|
|
|
|
|
:keywords: availability zones, AZ, fault tolerance, conductor groups,
|
|
|
|
|
shards, resource partitioning, high availability, scaling,
|
|
|
|
|
multiple deployments, nova compute
|
|
|
|
|
|
|
|
|
|
==========================================
|
|
|
|
|
Availability Zones and Resource Isolation
|
|
|
|
|
==========================================
|
|
|
|
|
|
|
|
|
|
Overview
|
|
|
|
|
========
|
|
|
|
|
|
|
|
|
|
While Ironic does not implement traditional OpenStack Availability Zones like
|
|
|
|
|
Nova and Neutron, it provides a **three-tier approach** for resource
|
|
|
|
|
partitioning and isolation that achieves comprehensive availability
|
|
|
|
|
zone functionality:
|
|
|
|
|
|
|
|
|
|
* **Multiple Ironic Deployments**: Completely separate Ironic services
|
|
|
|
|
targeted by different Nova compute nodes
|
|
|
|
|
* **Conductor Groups**: Physical/geographical resource partitioning within
|
|
|
|
|
a deployment
|
|
|
|
|
* **Shards**: Logical grouping for operational scaling within a deployment
|
|
|
|
|
|
|
|
|
|
This document explains how these mechanisms work together and how to achieve
|
|
|
|
|
sophisticated availability zone functionality across your infrastructure.
|
|
|
|
|
This document does **not** cover similar effect which can be achieved
|
|
|
|
|
through the use of API level Role Based Access Control through the
|
|
|
|
|
``owner`` and ``lessee`` fields.
|
|
|
|
|
|
|
|
|
|
.. contents:: Table of Contents
|
|
|
|
|
:local:
|
|
|
|
|
:depth: 2
|
|
|
|
|
|
|
|
|
|
Comparison with Other OpenStack Services
|
|
|
|
|
========================================
|
|
|
|
|
|
|
|
|
|
+------------------+-------------------+------------------------+
|
|
|
|
|
| Service | Mechanism | Purpose |
|
|
|
|
|
+==================+===================+========================+
|
|
|
|
|
| Nova | Availability | Instance placement |
|
|
|
|
|
| | Zones (host | across fault domains |
|
|
|
|
|
| | aggregates) | |
|
|
|
|
|
+------------------+-------------------+------------------------+
|
|
|
|
|
| Neutron | Agent AZs | Network service HA |
|
|
|
|
|
+------------------+-------------------+------------------------+
|
|
|
|
|
| **Ironic** | **Multiple | **Complete service |
|
|
|
|
|
| | Deployments + | isolation + physical |
|
|
|
|
|
| | Conductor Groups | partitioning + |
|
|
|
|
|
| | + Shards** | operational scaling** |
|
|
|
|
|
+------------------+-------------------+------------------------+
|
|
|
|
|
|
|
|
|
|
Ironic's Three-Tier Approach
|
|
|
|
|
=============================
|
|
|
|
|
|
|
|
|
|
Tier 1: Multiple Ironic Deployments
|
|
|
|
|
------------------------------------
|
|
|
|
|
|
|
|
|
|
The highest level of isolation involves running **completely separate
|
|
|
|
|
Ironic services** that Nova and other API users can target independently.
|
|
|
|
|
|
|
|
|
|
**Use Cases**:
|
|
|
|
|
|
|
|
|
|
* Complete geographic separation (different regions/countries)
|
|
|
|
|
* Regulatory compliance requiring full data isolation
|
|
|
|
|
* Independent upgrade cycles and operational teams
|
|
|
|
|
|
|
|
|
|
**Implementation**: Configure separate Nova compute services to target
|
|
|
|
|
different Ironic deployments using Nova's Ironic driver configuration.
|
|
|
|
|
|
|
|
|
|
**Benefits**:
|
|
|
|
|
|
|
|
|
|
* Complete fault isolation - failure of one deployment doesn't affect others
|
|
|
|
|
* Independent scaling, upgrades, and maintenance
|
|
|
|
|
* Different operational policies per deployment
|
|
|
|
|
* Complete API endpoint separation
|
|
|
|
|
|
|
|
|
|
Tier 2: Conductor Groups (Physical Partitioning)
|
|
|
|
|
-------------------------------------------------
|
|
|
|
|
|
|
|
|
|
Within a single Ironic deployment, conductor groups provides
|
|
|
|
|
**physical resource partitioning**.
|
|
|
|
|
|
|
|
|
|
**Use Cases**:
|
|
|
|
|
|
|
|
|
|
* Separate nodes by datacenter/availability zone within a region
|
|
|
|
|
* Separate nodes by conductor groups for conductor resource management
|
|
|
|
|
* Isolate hardware types or vendors
|
|
|
|
|
* Create fault domains for high availability
|
|
|
|
|
* Manage nodes with different network connectivity
|
|
|
|
|
|
|
|
|
|
Conductor groups control **which conductor manages which nodes**.
|
|
|
|
|
Each conductor can be assigned to a specific group, and will only
|
|
|
|
|
manage nodes that belong to the same group.
|
|
|
|
|
|
|
|
|
|
A classical challenge of Ironic is that it is able to manage far more
|
|
|
|
|
Bare Metal nodes than a single ``nova-compute`` service is designed to
|
|
|
|
|
support. The primary answer for this issue is to leverage Shards first,
|
|
|
|
|
and then continue to evolve based upon operational needs.
|
|
|
|
|
|
|
|
|
|
See: :doc:`conductor-groups` for detailed configuration.
|
|
|
|
|
|
|
|
|
|
.. _availability-zones-shards:
|
|
|
|
|
|
|
|
|
|
Tier 3: Shards (Logical Partitioning)
|
|
|
|
|
--------------------------------------
|
|
|
|
|
|
|
|
|
|
The finest level of granularity for **operational and client-side grouping**.
|
|
|
|
|
|
|
|
|
|
**Use Cases**:
|
|
|
|
|
|
|
|
|
|
* Horizontal scaling of operations
|
|
|
|
|
* Parallelize maintenance tasks
|
|
|
|
|
* Create logical groupings for different teams
|
|
|
|
|
|
|
|
|
|
Shards can be used by clients, including Nova, to limit the scope of their
|
|
|
|
|
requests to a logical and declared subset of nodes which prevents multiple
|
|
|
|
|
``nova-compute`` services from being able to see and work with the same
|
|
|
|
|
node on multiple ``nova-compute`` services.
|
|
|
|
|
|
|
|
|
|
.. note::
|
|
|
|
|
Shards are client-side constructs - Ironic itself does not use shard
|
|
|
|
|
values internally.
|
|
|
|
|
|
|
|
|
|
.. versionadded:: 1.82
|
|
|
|
|
Shard support was added in API version 1.82.
|
|
|
|
|
|
|
|
|
|
.. warning::
|
|
|
|
|
Once set, a shard should not be changed. Nova's model of leveraging the
|
|
|
|
|
Ironic API does not permit this value to be changed after the fact.
|
|
|
|
|
|
|
|
|
|
Common Deployment Patterns
|
|
|
|
|
===========================
|
|
|
|
|
|
|
|
|
|
Pattern 1: Multi-Region with Complete Isolation
|
|
|
|
|
------------------------------------------------
|
|
|
|
|
|
|
|
|
|
**Use Case**: Global deployment with regulatory compliance
|
|
|
|
|
|
|
|
|
|
**Implementation**:
|
|
|
|
|
|
|
|
|
|
- **Multiple Deployments**: ``ironic-us-east``, ``ironic-eu-west``, ``ironic-apac``
|
|
|
|
|
- **Nova Configuration**: Separate compute services per region
|
|
|
|
|
- **Conductor Groups**: Optional within each deployment
|
|
|
|
|
- **Shards**: Operational grouping within regions
|
|
|
|
|
|
|
|
|
|
**Example Nova Configuration**:
|
|
|
|
|
|
|
|
|
|
.. code-block:: ini
|
|
|
|
|
|
|
|
|
|
# nova-compute for US East region
|
|
|
|
|
[ironic]
|
|
|
|
|
auth_url = https://keystone-us-east.example.com/v3
|
|
|
|
|
endpoint_override = https://ironic-us-east.example.com
|
|
|
|
|
|
|
|
|
|
# nova-compute for EU West region
|
|
|
|
|
[ironic]
|
|
|
|
|
auth_url = https://keystone-eu-west.example.com/v3
|
|
|
|
|
endpoint_override = https://ironic-eu-west.example.com
|
|
|
|
|
|
|
|
|
|
.. note::
|
|
|
|
|
The above indicated ``endpoint_override`` configuration is provided
|
|
|
|
|
for illustrative purposes to stress endpoints would be distinctly
|
|
|
|
|
different.
|
|
|
|
|
|
|
|
|
|
Pattern 2: Single Region with Datacenter Separation
|
|
|
|
|
----------------------------------------------------
|
|
|
|
|
|
|
|
|
|
**Use Case**: Metro deployment across multiple datacenters
|
|
|
|
|
|
|
|
|
|
**Implementation**:
|
|
|
|
|
|
|
|
|
|
- **Single Deployment**: One Ironic service
|
|
|
|
|
- **Conductor Groups**: ``datacenter-1``, ``datacenter-2``, ``datacenter-3``
|
|
|
|
|
- **Nova Configuration**: Target specific conductor groups
|
|
|
|
|
- **Shards**: Optional operational grouping
|
|
|
|
|
|
|
|
|
|
In this case, we don't expect BMC management network access to occur between
|
|
|
|
|
datacenters. Thus each datacenter is configured with it's own group of
|
|
|
|
|
conductors.
|
|
|
|
|
|
|
|
|
|
**Example Configuration**:
|
|
|
|
|
|
|
|
|
|
.. code-block:: bash
|
|
|
|
|
|
|
|
|
|
# Configure Nova compute to target specific conductor group
|
|
|
|
|
[ironic]
|
|
|
|
|
conductor_group = datacenter-1
|
|
|
|
|
|
|
|
|
|
# Configure conductors (ironic.conf)
|
|
|
|
|
[conductor]
|
|
|
|
|
conductor_group = datacenter-1
|
|
|
|
|
|
|
|
|
|
# Assign nodes
|
|
|
|
|
baremetal node set --conductor-group datacenter-1 <node-uuid>
|
|
|
|
|
|
|
|
|
|
.. note::
|
|
|
|
|
Some larger operators who leverage conductor groups have suggested
|
|
|
|
|
that it is sometimes logical to have a conductor set without a
|
|
|
|
|
``conductor_group`` set. This helps prevent orphaning nodes because
|
|
|
|
|
Ironic routes all changes to the conductor which presently manages
|
|
|
|
|
the node.
|
|
|
|
|
|
|
|
|
|
Pattern 3: Operational Scaling Within Datacenters
|
|
|
|
|
--------------------------------------------------
|
|
|
|
|
|
|
|
|
|
**Use Case**: Large deployment requiring parallel operations
|
|
|
|
|
|
|
|
|
|
**Implementation**:
|
|
|
|
|
|
|
|
|
|
- **Single Deployment**: One Ironic service
|
|
|
|
|
- **Conductor Groups**: By datacenter or hardware type
|
|
|
|
|
- **Shards**: Operational batches for maintenance/upgrades
|
|
|
|
|
- **Nova Configuration**: May target specific conductor groups
|
|
|
|
|
|
|
|
|
|
**Example**:
|
|
|
|
|
|
|
|
|
|
.. code-block:: bash
|
|
|
|
|
|
|
|
|
|
# Set up conductor groups by hardware
|
|
|
|
|
baremetal node set --conductor-group dell-servers <node-uuid-1>
|
|
|
|
|
baremetal node set --conductor-group hpe-servers <node-uuid-2>
|
|
|
|
|
|
|
|
|
|
# Create operational shards for maintenance
|
|
|
|
|
baremetal node set --shard maintenance-batch-1 <node-uuid-1>
|
|
|
|
|
baremetal node set --shard maintenance-batch-2 <node-uuid-2>
|
|
|
|
|
|
|
|
|
|
Pattern 4: Hybrid Multi-Tier Approach
|
|
|
|
|
--------------------------------------
|
|
|
|
|
|
|
|
|
|
**Use Case**: Complex enterprise deployment
|
|
|
|
|
|
|
|
|
|
**Implementation**: All three tiers working together
|
|
|
|
|
|
|
|
|
|
**Example Architecture**:
|
|
|
|
|
|
|
|
|
|
.. code-block:: bash
|
|
|
|
|
|
|
|
|
|
# Deployment 1: Production East Coast
|
|
|
|
|
# Nova compute service targets ironic-prod-east
|
|
|
|
|
[ironic]
|
|
|
|
|
endpoint_override = https://ironic-prod-east.example.com
|
|
|
|
|
conductor_group = datacenter-east
|
|
|
|
|
|
|
|
|
|
# Within this deployment:
|
|
|
|
|
baremetal node set --conductor-group datacenter-east --shard prod-batch-a <node-uuid>
|
|
|
|
|
|
|
|
|
|
# Deployment 2: Production West Coast
|
|
|
|
|
# Nova compute service targets ironic-prod-west
|
|
|
|
|
[ironic]
|
|
|
|
|
endpoint_override = https://ironic-prod-west.example.com
|
|
|
|
|
conductor_group = datacenter-west
|
|
|
|
|
|
|
|
|
|
Nova Integration and Configuration
|
|
|
|
|
==================================
|
|
|
|
|
|
|
|
|
|
Targeting Multiple Ironic Deployments
|
|
|
|
|
--------------------------------------
|
|
|
|
|
|
|
|
|
|
Nova's Ironic driver can be configured to target different Ironic services:
|
|
|
|
|
|
|
|
|
|
**Per-Compute Service Configuration**:
|
|
|
|
|
|
|
|
|
|
.. code-block:: ini
|
|
|
|
|
|
|
|
|
|
# /etc/nova/nova.conf on compute-service-1
|
|
|
|
|
[ironic]
|
|
|
|
|
auth_url = https://keystone-region1.example.com/v3
|
|
|
|
|
endpoint_override = https://ironic-region1.example.com
|
|
|
|
|
conductor_group = region1-zone1
|
|
|
|
|
|
|
|
|
|
# /etc/nova/nova.conf on compute-service-2
|
|
|
|
|
[ironic]
|
|
|
|
|
auth_url = https://keystone-region2.example.com/v3
|
|
|
|
|
endpoint_override = https://ironic-region2.example.com
|
|
|
|
|
conductor_group = region2-zone1
|
|
|
|
|
|
|
|
|
|
**Advanced Options**:
|
|
|
|
|
|
|
|
|
|
.. code-block:: ini
|
|
|
|
|
|
|
|
|
|
[ironic]
|
|
|
|
|
# Target specific conductor group within deployment
|
|
|
|
|
conductor_group = datacenter-east
|
|
|
|
|
|
|
|
|
|
# Target specific shard within deployment
|
|
|
|
|
shard = production-nodes
|
|
|
|
|
|
|
|
|
|
# Connection retry configuration
|
|
|
|
|
api_max_retries = 60
|
|
|
|
|
api_retry_interval = 2
|
|
|
|
|
|
|
|
|
|
.. seealso::
|
|
|
|
|
`Nova Ironic Hypervisor Configuration <https://github.com/openstack/nova/blob/master/doc/source/admin/configuration/hypervisor-ironic.rst>`_
|
|
|
|
|
for complete Nova configuration details.
|
|
|
|
|
|
|
|
|
|
Scaling Considerations
|
|
|
|
|
----------------------
|
|
|
|
|
|
|
|
|
|
**Nova Compute Service Scaling**:
|
|
|
|
|
|
|
|
|
|
* Single nova-compute can handle several hundred Ironic nodes efficiently.
|
|
|
|
|
* Consider multiple compute services for >1000 nodes per deployment.
|
|
|
|
|
Nova-compute is modeled on keeping a relatively small number of "instances"
|
|
|
|
|
per nova-compute process. For example, 250 baremetal nodes.
|
|
|
|
|
* One nova-compute process per conductor group or shard is expected.
|
|
|
|
|
* A ``conductor_group`` which is independent of a nova-compute service
|
|
|
|
|
configuration can be changed at any time. A shard should never be
|
|
|
|
|
changed once it has been introduced to a nova-compute process.
|
|
|
|
|
|
|
|
|
|
**Multi-Deployment Benefits**:
|
|
|
|
|
|
|
|
|
|
* Independent scaling per deployment
|
|
|
|
|
* Isolated failure domains
|
|
|
|
|
* Different operational schedules
|
|
|
|
|
|
|
|
|
|
Integration Considerations
|
|
|
|
|
==========================
|
|
|
|
|
|
|
|
|
|
Network Considerations
|
|
|
|
|
----------------------
|
|
|
|
|
|
|
|
|
|
Ironic's partitioning works alongside physical network configuration:
|
|
|
|
|
|
|
|
|
|
* Physical networks can span multiple conductor groups
|
|
|
|
|
* Consider network topology when designing conductor group boundaries
|
|
|
|
|
* Ensure network connectivity between conductors and their assigned nodes
|
|
|
|
|
|
|
|
|
|
.. seealso::
|
|
|
|
|
:doc:`networking` for detailed network configuration guidance
|
|
|
|
|
|
|
|
|
|
Nova Placement and Scheduling
|
|
|
|
|
------------------------------
|
|
|
|
|
|
|
|
|
|
When using Ironic with Nova:
|
|
|
|
|
|
|
|
|
|
* Nova's availability zones operate independently of Ironic's partitioning
|
|
|
|
|
* Use resource classes and traits for capability-based scheduling
|
|
|
|
|
|
|
|
|
|
.. seealso::
|
|
|
|
|
:doc:`../install/configure-nova-flavors` for flavor and scheduling configuration
|
|
|
|
|
|
|
|
|
|
API Client Usage
|
|
|
|
|
================
|
|
|
|
|
|
|
|
|
|
Working Across Multiple Deployments
|
|
|
|
|
------------------------------------
|
|
|
|
|
|
|
|
|
|
When managing multiple Ironic deployments, use separate client configurations:
|
|
|
|
|
|
|
|
|
|
.. code-block:: bash
|
|
|
|
|
|
|
|
|
|
# Configure client for deployment 1
|
|
|
|
|
export OS_AUTH_URL=https://keystone-east.example.com/v3
|
|
|
|
|
export OS_ENDPOINT_OVERRIDE=https://ironic-east.example.com
|
|
|
|
|
baremetal node list
|
|
|
|
|
|
|
|
|
|
# Configure client for deployment 2
|
|
|
|
|
export OS_AUTH_URL=https://keystone-west.example.com/v3
|
|
|
|
|
export OS_ENDPOINT_OVERRIDE=https://ironic-west.example.com
|
|
|
|
|
baremetal node list
|
|
|
|
|
|
|
|
|
|
Filtering by Conductor Group
|
|
|
|
|
-----------------------------
|
|
|
|
|
|
|
|
|
|
.. code-block:: bash
|
|
|
|
|
|
|
|
|
|
# List nodes by conductor group
|
|
|
|
|
baremetal node list --conductor-group datacenter-east
|
|
|
|
|
|
|
|
|
|
# List ports by node conductor group
|
|
|
|
|
baremetal port list --conductor-group datacenter-east
|
|
|
|
|
|
|
|
|
|
Filtering by Shard
|
|
|
|
|
-------------------
|
|
|
|
|
|
|
|
|
|
.. code-block:: bash
|
|
|
|
|
|
|
|
|
|
# List nodes by shard
|
|
|
|
|
baremetal node list --shard batch-a
|
|
|
|
|
|
|
|
|
|
# Get shard distribution
|
|
|
|
|
baremetal shard list
|
|
|
|
|
|
|
|
|
|
# Find nodes without a shard assignment
|
|
|
|
|
baremetal node list --unsharded
|
|
|
|
|
|
|
|
|
|
Combined Filtering Within Deployments
|
|
|
|
|
--------------------------------------
|
|
|
|
|
|
|
|
|
|
.. code-block:: bash
|
|
|
|
|
|
|
|
|
|
# Within a single deployment, filter by conductor group and shard
|
|
|
|
|
baremetal node list --conductor-group datacenter-1 --shard maintenance-batch-a
|
|
|
|
|
|
|
|
|
|
# Set both conductor group and shard on a node
|
|
|
|
|
baremetal node set --conductor-group datacenter-east --shard batch-a <node-uuid>
|
|
|
|
|
|
|
|
|
|
# Get overview of resource distribution
|
|
|
|
|
baremetal shard list
|
|
|
|
|
baremetal conductor list
|
|
|
|
|
|
|
|
|
|
Best Practices
|
|
|
|
|
==============
|
|
|
|
|
|
|
|
|
|
Deployment Strategy Planning
|
|
|
|
|
----------------------------
|
|
|
|
|
|
|
|
|
|
1. **Assess isolation requirements**: Determine if you need complete service separation
|
|
|
|
|
2. **Plan geographic distribution**: Use multiple deployments for true regional separation
|
|
|
|
|
3. **Design conductor groups**: Align with physical/network boundaries
|
|
|
|
|
4. **Implement shard strategy**: Plan for operational efficiency
|
|
|
|
|
5. **Configure Nova appropriately**: Match Nova compute services to your architecture
|
|
|
|
|
|
|
|
|
|
Operational Considerations
|
|
|
|
|
--------------------------
|
|
|
|
|
|
|
|
|
|
**Multiple Deployments**:
|
|
|
|
|
|
|
|
|
|
* Maintain consistent tooling across deployments
|
|
|
|
|
* Plan for cross-deployment migrations if needed
|
|
|
|
|
* Monitor each deployment independently
|
|
|
|
|
* Coordinate upgrade schedules
|
|
|
|
|
|
|
|
|
|
**Within Deployments**:
|
|
|
|
|
|
|
|
|
|
* Monitor conductor distribution: ``baremetal shard list``
|
|
|
|
|
* Ensure conductor redundancy per group
|
|
|
|
|
* Align network topology with conductor groups
|
|
|
|
|
* Automate shard management for balance
|
|
|
|
|
|
|
|
|
|
**Nova Integration**:
|
|
|
|
|
|
|
|
|
|
* Plan compute service distribution across deployments
|
|
|
|
|
* Monitor nova-compute to Ironic node ratios
|
|
|
|
|
* Test failover scenarios between compute services
|
|
|
|
|
|
|
|
|
|
Naming Conventions
|
|
|
|
|
------------------
|
|
|
|
|
|
|
|
|
|
Naming patterns can be defined by the infrastructure operator and below
|
|
|
|
|
are some basic suggestions which may be relevant based upon operational
|
|
|
|
|
requirements.
|
|
|
|
|
|
|
|
|
|
**Conductor Groups**:
|
|
|
|
|
|
|
|
|
|
* Geographic: ``datacenter-east``, ``region-us-west``, ``rack-01``
|
|
|
|
|
* Hardware: ``dell-servers``, ``hpe-gen10``, ``gpu-nodes``
|
|
|
|
|
* Network: ``vlan-100``, ``isolated-network``
|
|
|
|
|
|
|
|
|
|
**Shards**:
|
|
|
|
|
|
|
|
|
|
* Operational: ``maintenance-batch-1``, ``upgrade-group-a``
|
|
|
|
|
* Size-based: ``small-nodes``, ``large-memory``
|
|
|
|
|
* Temporal: ``weekend-maintenance``, ``business-hours``
|
|
|
|
|
|
|
|
|
|
Decision Matrix
|
|
|
|
|
---------------
|
|
|
|
|
|
|
|
|
|
Choose your approach based on requirements:
|
|
|
|
|
|
|
|
|
|
+-------------------------+-------------------+-----------------+---------------+
|
|
|
|
|
| **Requirement** | **Multiple | **Conductor | **Shards** |
|
|
|
|
|
| | Deployments** | **Groups** | |
|
|
|
|
|
+=========================+===================+=================+===============+
|
|
|
|
|
| Complete isolation | ✓ Best | ✓ Good | ✗ No |
|
|
|
|
|
+-------------------------+-------------------+-----------------+---------------+
|
|
|
|
|
| Independent upgrades | ✓ Complete | ✓ Partial | ✗ No |
|
|
|
|
|
+-------------------------+-------------------+-----------------+---------------+
|
|
|
|
|
| Geographic separation | ✓ Best | ✓ Good | ✗ No |
|
|
|
|
|
+-------------------------+-------------------+-----------------+---------------+
|
|
|
|
|
| Operational scaling | ✗ Overhead | ✓ Good | ✓ Best |
|
|
|
|
|
+-------------------------+-------------------+-----------------+---------------+
|
|
|
|
|
| Resource efficiency | ✗ Lower | ✓ Good | ✓ Best |
|
|
|
|
|
+-------------------------+-------------------+-----------------+---------------+
|
|
|
|
|
|
|
|
|
|
Troubleshooting
|
|
|
|
|
===============
|
|
|
|
|
|
|
|
|
|
Multiple Deployment Issues
|
|
|
|
|
---------------------------
|
|
|
|
|
|
|
|
|
|
**Connectivity Problems**:
|
|
|
|
|
|
|
|
|
|
.. code-block:: bash
|
|
|
|
|
|
|
|
|
|
# Test connectivity to each deployment
|
|
|
|
|
baremetal --os-endpoint-override https://ironic-east.example.com node list
|
|
|
|
|
baremetal --os-endpoint-override https://ironic-west.example.com node list
|
|
|
|
|
|
|
|
|
|
**Nova Configuration Issues**:
|
|
|
|
|
|
|
|
|
|
.. code-block:: bash
|
|
|
|
|
|
|
|
|
|
# Check Nova compute service registration
|
|
|
|
|
openstack compute service list --service nova-compute
|
|
|
|
|
|
|
|
|
|
# Verify Nova can reach Ironic
|
|
|
|
|
grep -i ironic /var/log/nova/nova-compute.log
|
|
|
|
|
|
|
|
|
|
**Cross-Deployment Node Migration**:
|
|
|
|
|
|
|
|
|
|
.. code-block:: bash
|
|
|
|
|
|
|
|
|
|
# Export node data from source deployment
|
|
|
|
|
baremetal node show --fields all <node-uuid>
|
|
|
|
|
|
|
|
|
|
# Import to destination deployment (manual process)
|
|
|
|
|
# Note: Requires careful planning and may need custom tooling
|
|
|
|
|
|
|
|
|
|
Common Issues Within Deployments
|
|
|
|
|
---------------------------------
|
|
|
|
|
|
|
|
|
|
**Orphaned nodes**: Nodes without matching conductor groups cannot be managed
|
|
|
|
|
|
|
|
|
|
.. code-block:: bash
|
|
|
|
|
|
|
|
|
|
# Find nodes without conductor groups
|
|
|
|
|
baremetal node list --conductor-group ""
|
|
|
|
|
|
|
|
|
|
# List available conductor groups
|
|
|
|
|
baremetal conductor list
|
|
|
|
|
|
|
|
|
|
**Unbalanced shards**: Monitor node distribution across shards
|
|
|
|
|
|
|
|
|
|
.. code-block:: bash
|
|
|
|
|
|
|
|
|
|
# Check shard distribution
|
|
|
|
|
baremetal shard list
|
|
|
|
|
|
|
|
|
|
# Find heavily loaded shards
|
|
|
|
|
baremetal node list --shard <shard-name> | wc -l
|
|
|
|
|
|
|
|
|
|
**Missing conductor groups**: Ensure all groups have active conductors
|
|
|
|
|
|
|
|
|
|
.. code-block:: bash
|
|
|
|
|
|
|
|
|
|
# Check conductor status
|
|
|
|
|
baremetal conductor list
|
|
|
|
|
|
|
|
|
|
# Verify conductor group configuration
|
|
|
|
|
# Check ironic.conf [conductor] conductor_group setting
|
|
|
|
|
|
|
|
|
|
Migration Scenarios
|
|
|
|
|
-------------------
|
|
|
|
|
|
|
|
|
|
**Moving nodes between conductor groups**:
|
|
|
|
|
|
|
|
|
|
.. code-block:: bash
|
|
|
|
|
|
|
|
|
|
# Move node to different conductor group
|
|
|
|
|
baremetal node set --conductor-group new-group <node-uuid>
|
|
|
|
|
|
|
|
|
|
**Reassigning shards**:
|
|
|
|
|
|
|
|
|
|
.. code-block:: bash
|
|
|
|
|
|
|
|
|
|
# Change node shard assignment
|
|
|
|
|
baremetal node set --shard new-shard <node-uuid>
|
|
|
|
|
|
|
|
|
|
# Remove shard assignment
|
|
|
|
|
baremetal node unset --shard <node-uuid>
|
|
|
|
|
|
|
|
|
|
.. warning::
|
|
|
|
|
Shards should never be changed once a nova-compute service has
|
|
|
|
|
identified a node in Ironic. Changing a shard at this point is
|
|
|
|
|
an unsupported action. As such, Ironic's API RBAC policy restricts
|
|
|
|
|
these actions to a "System-Scoped Admin" user. Normal Admin users
|
|
|
|
|
are denied this capability due the restriction and requirement
|
|
|
|
|
on the nova-compute side of the consumption of shards.
|
|
|
|
|
|
|
|
|
|
See Also
|
|
|
|
|
========
|
|
|
|
|
|
|
|
|
|
* :doc:`conductor-groups` - Detailed conductor group configuration
|
|
|
|
|
* :doc:`networking` - Physical network considerations
|
|
|
|
|
* :doc:`../install/refarch/index` - Reference architectures
|
|
|
|
|
* :doc:`multitenancy` - Multi-tenant deployments
|
|
|
|
|
* :doc:`tuning` - Performance tuning considerations
|
|
|
|
|
* `Nova Ironic Driver Documentation <https://github.com/openstack/nova/blob/master/doc/source/admin/configuration/hypervisor-ironic.rst>`_
|
|
|
|
|
* `Nova Ironic Configuration Options <https://github.com/openstack/nova/blob/master/nova/conf/ironic.py>`_
|
|
|
|
|
|