Since iRMC S6 2.00, iRMC firmware disables IPMI over LAN with default iRMC firmware configuration. To deal with this firmware incompatibility, this commit modifies driver's methods which use IPMI to first try IPMI and, if IPMI fails, try to use Redfish API. Story: 2010396 Task: 46746 Change-Id: I1730279d2225f1248ecf7fe403a5e503b6c3ff87
694 lines
26 KiB
ReStructuredText
694 lines
26 KiB
ReStructuredText
.. _irmc:
|
|
|
|
===========
|
|
iRMC driver
|
|
===========
|
|
|
|
Overview
|
|
========
|
|
|
|
The iRMC driver enables control FUJITSU PRIMERGY via ServerView
|
|
Common Command Interface (SCCI). Support for FUJITSU PRIMERGY servers consists
|
|
of the ``irmc`` hardware type and a few hardware interfaces specific for that
|
|
hardware type.
|
|
|
|
Prerequisites
|
|
=============
|
|
|
|
* Install `python-scciclient <https://pypi.org/project/python-scciclient>`_
|
|
and `pysnmp <https://pypi.org/project/pysnmp>`_ packages::
|
|
|
|
$ pip install "python-scciclient>=0.7.2" pysnmp
|
|
|
|
Hardware Type
|
|
=============
|
|
|
|
The ``irmc`` hardware type is available for FUJITSU PRIMERGY servers. For
|
|
information on how to enable the ``irmc`` hardware type, see
|
|
:ref:`enable-hardware-types`.
|
|
|
|
Hardware interfaces
|
|
^^^^^^^^^^^^^^^^^^^
|
|
|
|
The ``irmc`` hardware type overrides the selection of the following
|
|
hardware interfaces:
|
|
|
|
* bios
|
|
Supports ``irmc`` and ``no-bios``.
|
|
The default is ``irmc``.
|
|
|
|
* boot
|
|
Supports ``irmc-virtual-media``, ``irmc-pxe``, and ``pxe``.
|
|
The default is ``irmc-virtual-media``. The ``irmc-virtual-media`` boot
|
|
interface enables the virtual media based deploy with IPA (Ironic Python
|
|
Agent).
|
|
|
|
.. warning::
|
|
We deprecated the ``pxe`` boot interface when used with ``irmc``
|
|
hardware type. Support for this interface will be removed in the
|
|
future. Instead, use ``irmc-pxe``. ``irmc-pxe`` boot interface
|
|
was introduced in Pike.
|
|
|
|
* console
|
|
Supports ``ipmitool-socat``, ``ipmitool-shellinabox``, and ``no-console``.
|
|
The default is ``ipmitool-socat``.
|
|
|
|
* inspect
|
|
Supports ``irmc``, ``inspector``, and ``no-inspect``.
|
|
The default is ``irmc``.
|
|
|
|
.. note::
|
|
:ironic-inspector-doc:`Ironic Inspector <>`
|
|
needs to be present and configured to use ``inspector`` as the
|
|
inspect interface.
|
|
|
|
* management
|
|
Supports only ``irmc``.
|
|
|
|
* power
|
|
Supports ``irmc``, which enables power control via ServerView Common
|
|
Command Interface (SCCI), by default. Also supports ``ipmitool``.
|
|
|
|
* raid
|
|
Supports ``irmc``, ``no-raid`` and ``agent``.
|
|
The default is ``no-raid``.
|
|
|
|
For other hardware interfaces, ``irmc`` hardware type supports the
|
|
Bare Metal reference interfaces. For more details about the hardware
|
|
interfaces and how to enable the desired ones, see
|
|
:ref:`enable-hardware-interfaces`.
|
|
|
|
Here is a complete configuration example with most of the supported hardware
|
|
interfaces enabled for ``irmc`` hardware type.
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
enabled_hardware_types = irmc
|
|
enabled_bios_interfaces = irmc
|
|
enabled_boot_interfaces = irmc-virtual-media,irmc-pxe
|
|
enabled_console_interfaces = ipmitool-socat,ipmitool-shellinabox,no-console
|
|
enabled_deploy_interfaces = direct
|
|
enabled_inspect_interfaces = irmc,inspector,no-inspect
|
|
enabled_management_interfaces = irmc
|
|
enabled_network_interfaces = flat,neutron
|
|
enabled_power_interfaces = irmc
|
|
enabled_raid_interfaces = no-raid,irmc
|
|
enabled_storage_interfaces = noop,cinder
|
|
enabled_vendor_interfaces = no-vendor,ipmitool
|
|
|
|
Here is a command example to enroll a node with ``irmc`` hardware type.
|
|
|
|
.. code-block:: console
|
|
|
|
baremetal node create \
|
|
--bios-interface irmc \
|
|
--boot-interface irmc-pxe \
|
|
--deploy-interface direct \
|
|
--inspect-interface irmc \
|
|
--raid-interface irmc
|
|
|
|
Node configuration
|
|
^^^^^^^^^^^^^^^^^^
|
|
|
|
Configuration via ``driver_info``
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
* Each node is configured for ``irmc`` hardware type by setting the following
|
|
ironic node object's properties:
|
|
|
|
- ``driver_info/irmc_address`` property to be ``IP address`` or
|
|
``hostname`` of the iRMC.
|
|
- ``driver_info/irmc_username`` property to be ``username`` for
|
|
the iRMC with administrator privileges.
|
|
- ``driver_info/irmc_password`` property to be ``password`` for
|
|
irmc_username.
|
|
|
|
.. note::
|
|
Fujitsu server equipped with iRMC S6 2.00 or later version of firmware
|
|
disables IPMI over LAN by default. However user may be able to enable IPMI
|
|
via BMC settings.
|
|
To handle this change, ``irmc`` hardware type first tries IPMI and,
|
|
if IPMI operation fails, ``irmc`` hardware type uses Redfish API of Fujitsu
|
|
server to provide Ironic functionalities.
|
|
So if user deploys Fujitsu server with iRMC S6 2.00 or later, user needs
|
|
to set Redfish related parameters in ``driver_info``.
|
|
|
|
- ``driver_info/redifsh_address`` property to be ``IP address`` or
|
|
``hostname`` of the iRMC. You can prefix it with protocol (e.g.
|
|
``https://``). If you don't provide protocol, Ironic assumes HTTPS
|
|
(i.e. add ``https://`` prefix).
|
|
iRMC with S6 2.00 or later only support HTTPS connection to Redfish API.
|
|
- ``driver_info/redfish_username`` to be user name of iRMC with administrative
|
|
privileges
|
|
- ``driver_info/redfish_password`` to be password of ``redfish_username``
|
|
- ``driver_info/redfish_verify_ca`` accepts values those accepted in
|
|
``driver_info/irmc_verify_ca``
|
|
- ``driver_info/redfish_auth_type`` to be one of ``basic``, ``session`` or
|
|
``auto``
|
|
|
|
* If ``port`` in ``[irmc]`` section of ``/etc/ironic/ironic.conf`` or
|
|
``driver_info/irmc_port`` is set to 443, ``driver_info/irmc_verify_ca``
|
|
will take effect:
|
|
|
|
``driver_info/irmc_verify_ca`` property takes one of 4 value (default value
|
|
is ``True``):
|
|
|
|
- ``True``: When set to ``True``, which certification file iRMC driver uses
|
|
is determined by ``requests`` Python module.
|
|
|
|
Value of ``driver_info/irmc_verify_ca`` is passed to ``verify`` argument
|
|
of functions defined in ``requests`` Python module. So which certification
|
|
will be used is depend on behavior of ``requests`` module.
|
|
(maybe certification provided by ``certifi`` Python module)
|
|
|
|
- ``False``: When set to ``False``, iRMC driver won't verify server
|
|
certification with certification file during HTTPS connection with iRMC.
|
|
Just stop to verify server certification, but does HTTPS.
|
|
|
|
.. warning::
|
|
When set to ``False``, user must notice that it can result in
|
|
vulnerable situation. Stopping verification of server certification
|
|
during HTTPS connection means it cannot prevent Man-in-the-middle
|
|
attack. When set to ``False``, Ironic user must take enough care
|
|
around infrastructure environment in terms of security.
|
|
(e.g. make sure network between Ironic conductor and iRMC is secure)
|
|
|
|
- string representing filesystem path to directory which contains
|
|
certification file: In this case, iRMC driver uses certification file
|
|
stored at specified directory. Ironic conductor must be able to access
|
|
that directory. For iRMC to recongnize certification file, Ironic user
|
|
must run ``openssl rehash <path_to_dir>``.
|
|
|
|
- string representing filesystem path to certification file: In this case,
|
|
iRMC driver uses certification file specified. Ironic conductor must have
|
|
access to that file.
|
|
|
|
|
|
* The following properties are also required if ``irmc-virtual-media`` boot
|
|
interface is used:
|
|
|
|
- ``driver_info/deploy_iso`` property to be either deploy iso
|
|
file name, Glance UUID, or Image Service URL.
|
|
- ``instance info/boot_iso`` property to be either boot iso
|
|
file name, Glance UUID, or Image Service URL. This is used
|
|
with the ``ramdisk`` deploy interface.
|
|
|
|
.. note::
|
|
The ``deploy_iso`` and ``boot_iso`` properties used to be called
|
|
``irmc_deploy_iso`` and ``irmc_boot_iso`` accordingly before the Xena
|
|
release.
|
|
|
|
* The following properties are also required if ``irmc`` inspect interface is
|
|
enabled and SNMPv3 inspection is desired.
|
|
|
|
- ``driver_info/irmc_snmp_user`` property to be the SNMPv3 username. SNMPv3
|
|
functionality should be enabled for this user on iRMC server side.
|
|
- ``driver_info/irmc_snmp_auth_password`` property to be the auth protocol
|
|
pass phrase. The length of pass phrase should be at least 8 characters.
|
|
- ``driver_info/irmc_snmp_priv_password`` property to be the privacy protocol
|
|
pass phrase. The length of pass phrase should be at least 8 characters.
|
|
|
|
|
|
Configuration via ``properties``
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
* Each node is configured for ``irmc`` hardware type by setting the following
|
|
ironic node object's properties:
|
|
|
|
- ``properties/capabilities`` property to be ``boot_mode:uefi`` if
|
|
UEFI boot is required, or ``boot_mode:bios`` if Legacy BIOS is required.
|
|
If this is not set, ``default_boot_mode`` at ``[default]`` section in
|
|
``ironic.conf`` will be used.
|
|
- ``properties/capabilities`` property to be ``secure_boot:true`` if
|
|
UEFI Secure Boot is required. Please refer to `UEFI Secure Boot Support`_
|
|
for more information.
|
|
|
|
|
|
Configuration via ``ironic.conf``
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
* All of the nodes are configured by setting the following configuration
|
|
options in the ``[irmc]`` section of ``/etc/ironic/ironic.conf``:
|
|
|
|
- ``port``: Port to be used for iRMC operations; either 80
|
|
or 443. The default value is 443. Optional.
|
|
|
|
.. note::
|
|
Since iRMC S6 2.00, iRMC firmware doesn't support HTTP connection to
|
|
REST API. If you deploy server with iRMS S6 2.00 and later, please
|
|
set ``port`` to 443.
|
|
|
|
``irmc`` hardware type provides ``verify_step`` named
|
|
``verify_http_https_connection_and_fw_version`` to check HTTP(S)
|
|
connection to iRMC REST API. If HTTP(S) connection is successfully
|
|
established, then it fetches and caches iRMC firmware version.
|
|
If HTTP(S) connection to iRMC REST API failed, Ironic node's state
|
|
moves to ``enroll`` with suggestion put in log message.
|
|
Default priority of this verify step is 10.
|
|
|
|
If operator updates iRMC firmware version of node, operator should
|
|
run ``cache_irmc_firmware_version`` node vendor passthru method
|
|
to update iRMC firmware version stored in
|
|
``driver_internal_info/irmc_fw_version``.
|
|
|
|
- ``auth_method``: Authentication method for iRMC operations;
|
|
either ``basic`` or ``digest``. The default value is ``basic``. Optional.
|
|
- ``client_timeout``: Timeout (in seconds) for iRMC
|
|
operations. The default value is 60. Optional.
|
|
- ``sensor_method``: Sensor data retrieval method; either
|
|
``ipmitool`` or ``scci``. The default value is ``ipmitool``. Optional.
|
|
|
|
* The following options are required if ``irmc-virtual-media`` boot
|
|
interface is enabled:
|
|
|
|
- ``remote_image_share_root``: Ironic conductor node's ``NFS`` or
|
|
``CIFS`` root path. The default value is ``/remote_image_share_root``.
|
|
- ``remote_image_server``: IP of remote image server.
|
|
- ``remote_image_share_type``: Share type of virtual media, either
|
|
``NFS`` or ``CIFS``. The default is ``CIFS``.
|
|
- ``remote_image_share_name``: share name of ``remote_image_server``.
|
|
The default value is ``share``.
|
|
- ``remote_image_user_name``: User name of ``remote_image_server``.
|
|
- ``remote_image_user_password``: Password of ``remote_image_user_name``.
|
|
- ``remote_image_user_domain``: Domain name of ``remote_image_user_name``.
|
|
|
|
* The following options are required if ``irmc`` inspect interface is enabled:
|
|
|
|
- ``snmp_version``: SNMP protocol version; either ``v1``, ``v2c`` or
|
|
``v3``. The default value is ``v2c``. Optional.
|
|
- ``snmp_port``: SNMP port. The default value is ``161``. Optional.
|
|
- ``snmp_community``: SNMP community required for versions ``v1``
|
|
and ``v2c``. The default value is ``public``. Optional.
|
|
- ``snmp_security``: SNMP security name required for version ``v3``.
|
|
Optional.
|
|
- ``snmp_auth_proto``: The SNMPv3 auth protocol. If using iRMC S4 or S5, the
|
|
valid value of this option is only ``sha``. If using iRMC S6, the valid
|
|
values are ``sha256``, ``sha384`` and ``sha512``. The default value is
|
|
``sha``. Optional.
|
|
- ``snmp_priv_proto``: The SNMPv3 privacy protocol. The valid value and
|
|
the default value are both ``aes``. We will add more supported valid values
|
|
in the future. Optional.
|
|
|
|
.. warning::
|
|
We deprecated the ``snmp_security`` option when use SNMPv3 inspection.
|
|
Support for this option will be removed in the future. Instead, set
|
|
``driver_info/irmc_snmp_user`` parameter for each node if SNMPv3
|
|
inspection is needed.
|
|
|
|
|
|
Override ``ironic.conf`` configuration via ``driver_info``
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
* Each node can be further configured by setting the following ironic
|
|
node object's properties which override the parameter values in
|
|
``[irmc]`` section of ``/etc/ironic/ironic.conf``:
|
|
|
|
- ``driver_info/irmc_port`` property overrides ``port``.
|
|
- ``driver_info/irmc_auth_method`` property overrides ``auth_method``.
|
|
- ``driver_info/irmc_client_timeout`` property overrides ``client_timeout``.
|
|
- ``driver_info/irmc_sensor_method`` property overrides ``sensor_method``.
|
|
- ``driver_info/irmc_snmp_version`` property overrides ``snmp_version``.
|
|
- ``driver_info/irmc_snmp_port`` property overrides ``snmp_port``.
|
|
- ``driver_info/irmc_snmp_community`` property overrides ``snmp_community``.
|
|
- ``driver_info/irmc_snmp_security`` property overrides ``snmp_security``.
|
|
- ``driver_info/irmc_snmp_auth_proto`` property overrides
|
|
``snmp_auth_proto``.
|
|
- ``driver_info/irmc_snmp_priv_proto`` property overrides
|
|
``snmp_priv_proto``.
|
|
|
|
|
|
Optional functionalities for the ``irmc`` hardware type
|
|
=======================================================
|
|
|
|
UEFI Secure Boot Support
|
|
^^^^^^^^^^^^^^^^^^^^^^^^
|
|
The hardware type ``irmc`` supports secure boot deploy, see :ref:`secure-boot`
|
|
for details.
|
|
|
|
.. warning::
|
|
Secure boot feature is not supported with ``pxe`` boot interface.
|
|
|
|
.. _irmc_node_cleaning:
|
|
|
|
Node Cleaning Support
|
|
^^^^^^^^^^^^^^^^^^^^^
|
|
The ``irmc`` hardware type supports node cleaning.
|
|
For more information on node cleaning, see :ref:`cleaning`.
|
|
|
|
Supported **Automated** Cleaning Operations
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The automated cleaning operations supported are:
|
|
|
|
* ``restore_irmc_bios_config``:
|
|
Restores BIOS settings on a baremetal node from backup data. If this
|
|
clean step is enabled, the BIOS settings of a baremetal node will be
|
|
backed up automatically before the deployment. By default, this clean
|
|
step is disabled with priority ``0``. Set its priority to a positive
|
|
integer to enable it. The recommended value is ``10``.
|
|
|
|
.. warning::
|
|
``pxe`` boot interface, when used with ``irmc`` hardware type, does
|
|
not support this clean step. If uses ``irmc`` hardware type, it is
|
|
required to select ``irmc-pxe`` or ``irmc-virtual-media`` as the
|
|
boot interface in order to make this clean step work.
|
|
|
|
|
|
Configuration options for the automated cleaning steps are listed under
|
|
``[irmc]`` section in ironic.conf ::
|
|
|
|
clean_priority_restore_irmc_bios_config = 0
|
|
|
|
For more information on node automated cleaning, see :ref:`automated_cleaning`
|
|
|
|
Boot from Remote Volume
|
|
^^^^^^^^^^^^^^^^^^^^^^^
|
|
The ``irmc`` hardware type supports the generic PXE-based remote volume
|
|
booting when using the following boot interfaces:
|
|
|
|
* ``irmc-pxe``
|
|
* ``pxe``
|
|
|
|
In addition, the ``irmc`` hardware type supports remote volume booting without
|
|
PXE. This is available when using the ``irmc-virtual-media`` boot interface.
|
|
This feature configures a node to boot from a remote volume by using the API
|
|
of iRMC. It supports iSCSI and FibreChannel.
|
|
|
|
Configuration
|
|
~~~~~~~~~~~~~
|
|
|
|
In addition to the configuration for generic drivers to
|
|
:ref:`remote volume boot <boot-from-volume>`,
|
|
the iRMC driver requires the following configuration:
|
|
|
|
* It is necessary to set physical port IDs to network ports and volume
|
|
connectors. All cards including those not used for volume boot should be
|
|
registered.
|
|
|
|
The format of a physical port ID is: ``<Card Type><Slot No>-<Port No>`` where:
|
|
|
|
- ``<Card Type>``: could be ``LAN``, ``FC`` or ``CNA``
|
|
- ``<Slot No>``: 0 indicates onboard slot. Use 1 to 9 for add-on slots.
|
|
- ``<Port No>``: A port number starting from 1.
|
|
|
|
These IDs are specified in a node's ``driver_info[irmc_pci_physical_ids]``.
|
|
This value is a dictionary. The key is the UUID of a resource (Port or Volume
|
|
Connector) and its value is the physical port ID. For example::
|
|
|
|
{
|
|
"1ecd14ee-c191-4007-8413-16bb5d5a73a2":"LAN0-1",
|
|
"87f6c778-e60e-4df2-bdad-2605d53e6fc0":"CNA1-1"
|
|
}
|
|
|
|
It can be set with the following command::
|
|
|
|
baremetal node set $NODE_UUID \
|
|
--driver-info irmc_pci_physical_ids={} \
|
|
--driver-info irmc_pci_physical_ids/$PORT_UUID=LAN0-1 \
|
|
--driver-info irmc_pci_physical_ids/$VOLUME_CONNECTOR_UUID=CNA1-1
|
|
|
|
* For iSCSI boot, volume connectors with both types ``iqn`` and ``ip`` are
|
|
required. The configuration with DHCP is not supported yet.
|
|
|
|
* For iSCSI, the size of the storage network is needed. This value should be
|
|
specified in a node's ``driver_info[irmc_storage_network_size]``. It must be
|
|
a positive integer < 32.
|
|
For example, if the storage network is 10.2.0.0/22, use the following
|
|
command::
|
|
|
|
baremetal node set $NODE_UUID --driver-info irmc_storage_network_size=22
|
|
|
|
Supported hardware
|
|
~~~~~~~~~~~~~~~~~~
|
|
|
|
The driver supports the PCI controllers, Fibrechannel Cards, Converged Network
|
|
Adapters supported by
|
|
`Fujitsu ServerView Virtual-IO Manager <http://www.fujitsu.com/fts/products/computing/servers/primergy/management/primergy-blade-server-io-virtualization.html>`_.
|
|
|
|
Hardware Inspection Support
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
The ``irmc`` hardware type provides the iRMC-specific hardware inspection
|
|
with ``irmc`` inspect interface.
|
|
|
|
.. note::
|
|
SNMP requires being enabled in ServerView® iRMC S4 Web Server(Network
|
|
Settings\SNMP section).
|
|
|
|
Configuration
|
|
~~~~~~~~~~~~~
|
|
|
|
The Hardware Inspection Support in the iRMC driver requires the following
|
|
configuration:
|
|
|
|
* It is necessary to set ironic configuration with ``gpu_ids`` and
|
|
``fpga_ids`` options in ``[irmc]`` section.
|
|
|
|
``gpu_ids`` and ``fpga_ids`` are lists of ``<vendorID>/<deviceID>`` where:
|
|
|
|
- ``<vendorID>``: 4 hexadecimal digits starts with '0x'.
|
|
- ``<deviceID>``: 4 hexadecimal digits starts with '0x'.
|
|
|
|
Here are sample values for ``gpu_ids`` and ``fpga_ids``::
|
|
|
|
gpu_ids = 0x1000/0x0079,0x2100/0x0080
|
|
fpga_ids = 0x1000/0x005b,0x1100/0x0180
|
|
|
|
* The python-scciclient package requires pyghmi version >= 1.0.22 and pysnmp
|
|
version >= 4.2.3. They are used by the conductor service on the conductor.
|
|
The latest version of pyghmi can be downloaded from `here
|
|
<https://pypi.org/project/pyghmi/>`__
|
|
and pysnmp can be downloaded from `here
|
|
<https://pypi.org/project/pysnmp/>`__.
|
|
|
|
Supported properties
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The inspection process will discover the following essential properties
|
|
(properties required for scheduling deployment):
|
|
|
|
* ``memory_mb``: memory size
|
|
|
|
* ``cpus``: number of cpus
|
|
|
|
* ``cpu_arch``: cpu architecture
|
|
|
|
* ``local_gb``: disk size
|
|
|
|
Inspection can also discover the following extra capabilities for iRMC
|
|
driver:
|
|
|
|
* ``irmc_firmware_version``: iRMC firmware version
|
|
|
|
* ``rom_firmware_version``: ROM firmware version
|
|
|
|
* ``server_model``: server model
|
|
|
|
* ``pci_gpu_devices``: number of gpu devices connected to the bare metal.
|
|
|
|
Inspection can also set/unset node's traits with the following cpu type for
|
|
iRMC driver:
|
|
|
|
* ``CUSTOM_CPU_FPGA``: The bare metal contains fpga cpu type.
|
|
|
|
.. note::
|
|
|
|
* The disk size is returned only when eLCM License for FUJITSU PRIMERGY
|
|
servers is activated. If the license is not activated, then Hardware
|
|
Inspection will fail to get this value.
|
|
* Before inspecting, if the server is power-off, it will be turned on
|
|
automatically. System will wait for a few second before start
|
|
inspecting. After inspection, power status will be restored to the
|
|
previous state.
|
|
|
|
The operator can specify these capabilities in compute service flavor, for
|
|
example::
|
|
|
|
openstack flavor set baremetal-flavor-name --property capabilities:irmc_firmware_version="iRMC S4-8.64F"
|
|
|
|
openstack flavor set baremetal-flavor-name --property capabilities:server_model="TX2540M1F5"
|
|
|
|
openstack flavor set baremetal-flavor-name --property capabilities:pci_gpu_devices="1"
|
|
|
|
See :ref:`capabilities-discovery` for more details and examples.
|
|
|
|
The operator can add a trait in compute service flavor, for example::
|
|
|
|
baremetal node add trait $NODE_UUID CUSTOM_CPU_FPGA
|
|
|
|
A valid trait must be no longer than 255 characters. Standard traits are
|
|
defined in the os_traits library. A custom trait must start with the prefix
|
|
``CUSTOM_`` and use the following characters: A-Z, 0-9 and _.
|
|
|
|
RAID configuration Support
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
The ``irmc`` hardware type provides the iRMC RAID configuration with ``irmc``
|
|
raid interface.
|
|
|
|
.. note::
|
|
|
|
* RAID implementation for ``irmc`` hardware type is based on eLCM license
|
|
and SDCard. Otherwise, SP(Service Platform) in lifecycle management
|
|
must be available.
|
|
* RAID implementation only supported for RAIDAdapter 0 in Fujitsu Servers.
|
|
|
|
Configuration
|
|
~~~~~~~~~~~~~
|
|
|
|
The RAID configuration Support in the iRMC drivers requires the following
|
|
configuration:
|
|
|
|
* It is necessary to set ironic configuration into Node with
|
|
JSON file option::
|
|
|
|
$ baremetal node set <node-uuid-or-name> \
|
|
--target-raid-config <JSON file containing target RAID configuration>
|
|
|
|
Here is some sample values for JSON file::
|
|
|
|
{
|
|
"logical_disks": [
|
|
{
|
|
"size_gb": 1000,
|
|
"raid_level": "1"
|
|
]
|
|
}
|
|
|
|
or::
|
|
|
|
{
|
|
"logical_disks": [
|
|
{
|
|
"size_gb": 1000,
|
|
"raid_level": "1",
|
|
"controller": "FTS RAID Ctrl SAS 6G 1GB (D3116C) (0)",
|
|
"physical_disks": [
|
|
"0",
|
|
"1"
|
|
]
|
|
}
|
|
]
|
|
}
|
|
|
|
.. note::
|
|
|
|
RAID 1+0 and 5+0 in iRMC driver does not support property ``physical_disks``
|
|
in ``target_raid_config`` during create raid configuration yet. See
|
|
following example::
|
|
|
|
{
|
|
"logical_disks":
|
|
[
|
|
{
|
|
"size_gb": "MAX",
|
|
"raid_level": "1+0"
|
|
}
|
|
]
|
|
}
|
|
|
|
See :ref:`raid` for more details and examples.
|
|
|
|
Supported properties
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The RAID configuration using iRMC driver supports following parameters in
|
|
JSON file:
|
|
|
|
* ``size_gb``: is mandatory properties in Ironic.
|
|
* ``raid_level``: is mandatory properties in Ironic. Currently, iRMC Server
|
|
supports following RAID levels: 0, 1, 5, 6, 1+0 and 5+0.
|
|
* ``controller``: is name of the controller as read by the RAID interface.
|
|
* ``physical_disks``: are specific values for each raid array in
|
|
LogicalDrive which operator want to set them along with ``raid_level``.
|
|
|
|
The RAID configuration is supported as a manual cleaning step.
|
|
|
|
.. note::
|
|
|
|
* iRMC server will power-on after create/delete raid configuration is
|
|
applied, FGI (Foreground Initialize) will process raid configuration in
|
|
iRMC server, thus the operation will completed upon power-on and power-off
|
|
when created RAID on iRMC server.
|
|
|
|
See :ref:`raid` for more details and examples.
|
|
|
|
BIOS configuration Support
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
The ``irmc`` hardware type provides the iRMC BIOS configuration with ``irmc``
|
|
bios interface.
|
|
|
|
.. warning::
|
|
``irmc`` bios interface does not support ``factory_reset``.
|
|
|
|
Starting from version ``0.10.0`` of ``python-scciclient``,
|
|
the BIOS setting obtained may not be the latest. If you want to get the latest BIOS setting,
|
|
you need to delete the existing BIOS profile in iRMC. For example::
|
|
|
|
curl -u user:pass -H "Content-type: application/json" -X DELETE -i http://192.168.0.1/rest/v1/Oem/eLCM/ProfileManagement/BiosConfig
|
|
|
|
Configuration
|
|
~~~~~~~~~~~~~
|
|
|
|
The BIOS configuration in the iRMC driver supports the following settings:
|
|
|
|
- ``boot_option_filter``: Specifies from which drives can be booted. This
|
|
supports following options: ``UefiAndLegacy``, ``LegacyOnly``, ``UefiOnly``.
|
|
- ``check_controllers_health_status_enabled``: The UEFI FW checks the
|
|
controller health status. This supports following options: ``true``, ``false``.
|
|
- ``cpu_active_processor_cores``: The number of active processor cores 1...n.
|
|
Option 0 indicates that all available processor cores are active.
|
|
- ``cpu_adjacent_cache_line_prefetch_enabled``: The processor loads the requested
|
|
cache line and the adjacent cache line. This supports following options:
|
|
``true``, ``false``.
|
|
- ``cpu_vt_enabled``: Supports the virtualization of platform hardware and
|
|
several software environments, based on Virtual Machine Extensions to
|
|
support the use of several software environments using virtual computers.
|
|
This supports following options: ``true``, ``false``.
|
|
- ``flash_write_enabled``: The system BIOS can be written. Flash BIOS update
|
|
is possible. This supports following options: ``true``, ``false``.
|
|
- ``hyper_threading_enabled``: Hyper-threading technology allows a single
|
|
physical processor core to appear as several logical processors. This
|
|
supports following options: ``true``, ``false``.
|
|
- ``keep_void_boot_options_enabled``: Boot Options will not be removed from
|
|
"Boot Option Priority" list. This supports following options: ``true``,
|
|
``false``.
|
|
- ``launch_csm_enabled``: Specifies whether the Compatibility Support Module
|
|
(CSM) is executed. This supports following options: ``true``, ``false``.
|
|
- ``os_energy_performance_override_enabled``: Prevents the OS from overruling
|
|
any energy efficiency policy setting of the setup. This supports following
|
|
options: ``true``, ``false``.
|
|
- ``pci_aspm_support``: Active State Power Management (ASPM) is used to
|
|
power-manage the PCI Express links, thus consuming less power. This
|
|
supports following options: ``Disabled``, ``Auto``, ``L0Limited``,
|
|
``L1only``, ``L0Force``.
|
|
- ``pci_above_4g_decoding_enabled``: Specifies if memory resources above the
|
|
4GB address boundary can be assigned to PCI devices. This supports
|
|
following options: ``true``, ``false``.
|
|
- ``power_on_source``: Specifies whether the switch on sources for the system
|
|
are managed by the BIOS or the ACPI operating system. This supports
|
|
following options: ``BiosControlled``, ``AcpiControlled``.
|
|
- ``single_root_io_virtualization_support_enabled``: Single Root IO
|
|
Virtualization Support is active. This supports following
|
|
options: ``true``, ``false``.
|
|
|
|
The BIOS configuration is supported as a manual cleaning step. See :ref:`bios`
|
|
for more details and examples.
|
|
|
|
Supported platforms
|
|
===================
|
|
This driver supports FUJITSU PRIMERGY RX M4 servers and above.
|
|
|
|
When ``irmc`` power interface is used, Soft Reboot (Graceful Reset) and Soft
|
|
Power Off (Graceful Power Off) are only available if
|
|
`ServerView agents <http://manuals.ts.fujitsu.com/index.php?id=5406-5873-5925-5945-16159>`_
|
|
are installed. See `iRMC S4 Manual <http://manuals.ts.fujitsu.com/index.php?id=5406-5873-5925-5988>`_
|
|
for more details.
|
|
|
|
RAID configuration feature supports FUJITSU PRIMERGY servers with
|
|
RAID-Ctrl-SAS-6G-1GB(D3116C) controller and above.
|
|
For detail supported controller with OOB-RAID configuration, please see
|
|
`the whitepaper for iRMC RAID configuration <http://manuals.ts.fujitsu.com/file/12073/wp-svs-oob-raid-hdd-en.pdf>`_.
|