Upgrading to Hardware Types
|
|
===========================
|
|
|
|
Starting with the Rocky release, the Bare Metal service does not support
|
|
*classic drivers* any more. If you still use *classic drivers*, please
|
|
upgrade to *hardware types* immediately. Please see
|
|
:doc:`/install/enabling-drivers` for details on
|
|
*hardware types* and *hardware interfaces*.
|
|
|
|
Planning the upgrade
|
|
--------------------
|
|
|
|
It is necessary to figure out which hardware types and hardware interfaces
|
|
correspond to which classic drivers used in your deployment. The following
|
|
table lists the classic drivers with their corresponding hardware types and
|
|
the boot, deploy, inspect, management, and power hardware interfaces:
|
|
|
|
===================== ==================== ==================== ============== ========== ========== =========
|
|
Classic Driver Hardware Type Boot Deploy Inspect Management Power
|
|
===================== ==================== ==================== ============== ========== ========== =========
|
|
agent_ilo ilo ilo-virtual-media direct ilo ilo ilo
|
|
agent_ipmitool ipmi pxe direct inspector ipmitool ipmitool
|
|
agent_ipmitool_socat ipmi pxe direct inspector ipmitool ipmitool
|
|
agent_irmc irmc irmc-virtual-media direct irmc irmc irmc
|
|
iscsi_ilo ilo ilo-virtual-media iscsi ilo ilo ilo
|
|
iscsi_irmc irmc irmc-virtual-media iscsi irmc irmc irmc
|
|
pxe_drac idrac pxe iscsi idrac idrac idrac
|
|
pxe_drac_inspector idrac pxe iscsi inspector idrac idrac
|
|
pxe_ilo ilo ilo-pxe iscsi ilo ilo ilo
|
|
pxe_ipmitool ipmi pxe iscsi inspector ipmitool ipmitool
|
|
pxe_ipmitool_socat ipmi pxe iscsi inspector ipmitool ipmitool
|
|
pxe_irmc irmc irmc-pxe iscsi irmc irmc irmc
|
|
pxe_snmp snmp pxe iscsi no-inspect fake snmp
|
|
===================== ==================== ==================== ============== ========== ========== =========
|
|
|
|
.. note::
|
|
The ``inspector`` *inspect* interface was only used if
|
|
explicitly enabled in the configuration. Otherwise, ``no-inspect``
|
|
was used.
|
|
|
|
.. note::
|
|
``pxe_ipmitool_socat`` and ``agent_ipmitool_socat`` use
|
|
``ipmitool-socat`` *console* interface (the default for the ``ipmi``
|
|
hardware type), while ``pxe_ipmitool`` and ``agent_ipmitool`` use
|
|
``ipmitool-shellinabox``. See Console_ for details.
|
|
|
|
For out-of-tree drivers you may need to reach out to their maintainers or
|
|
figure out the appropriate interfaces by researching the source code.
|
|
|
|
Configuration
|
|
-------------
|
|
|
|
You will need to enable hardware types and interfaces that correspond to your
|
|
currently enabled classic drivers. For example, if you have the following
|
|
configuration in your ``ironic.conf``:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
enabled_drivers = pxe_ipmitool,agent_ipmitool
|
|
|
|
You will have to add this configuration as well:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
enabled_hardware_types = ipmi
|
|
enabled_boot_interfaces = pxe
|
|
enabled_deploy_interfaces = iscsi,direct
|
|
enabled_management_interfaces = ipmitool
|
|
enabled_power_interfaces = ipmitool
|
|
|
|
.. note::
|
|
For every interface type there is an option
|
|
``default_<INTERFACE>_interface``, where ``<INTERFACE>`` is the interface
|
|
type name. For example, one can make all nodes use the ``direct`` deploy
|
|
method by default by setting:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
default_deploy_interface = direct
|
|
|
|
Migrating nodes
|
|
---------------
|
|
|
|
After the required items are enabled in the configuration, each node's
|
|
``driver`` field has to be updated to a new value. You may need to also
|
|
set new values for some or all interfaces:
|
|
|
|
.. code-block:: console
|
|
|
|
export OS_BAREMETAL_API_VERSION=1.31
|
|
|
|
for uuid in $(baremetal node list --driver pxe_ipmitool -f value -c UUID); do
|
|
baremetal node set <node> --driver ipmi --deploy-interface iscsi
|
|
done
|
|
|
|
for uuid in $(baremetal node list --driver agent_ipmitool -f value -c UUID); do
|
|
baremetal node set <node> --driver ipmi --deploy-interface direct
|
|
done
|
|
|
|
See :doc:`/install/enrollment` for more details on setting hardware types and
|
|
interfaces.
|
|
|
|
.. warning::
|
|
It is not recommended to change the interfaces for ``active`` nodes. If
|
|
absolutely needed, the nodes have to be put in the maintenance mode first:
|
|
|
|
.. code-block:: console
|
|
|
|
baremetal node maintenance set $UUID \
|
|
--reason "Changing driver and/or hardware interfaces"
|
|
# do the update, validate its correctness
|
|
baremetal node maintenance unset $UUID
|
|
|
|
Other interfaces
|
|
----------------
|
|
|
|
Care has to be taken to migrate from classic drivers using non-default
|
|
interfaces. This chapter covers a few of the most commonly used.
|
|
|
|
Ironic Inspector
|
|
~~~~~~~~~~~~~~~~
|
|
|
|
Some classic drivers, notably ``pxe_ipmitool``, ``agent_ipmitool`` and
|
|
``pxe_drac_inspector``, use ironic-inspector_ for their *inspect* interface.
|
|
|
|
The same functionality is available for all hardware types, but the appropriate
|
|
``inspect`` interface has to be enabled in the Bare Metal service configuration
|
|
file, for example:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
enabled_inspect_interfaces = inspector,no-inspect
|
|
|
|
See :doc:`/install/enabling-drivers` for more details.
|
|
|
|
.. note::
|
|
The configuration option ``[inspector]enabled`` does not affect hardware
|
|
types.
|
|
|
|
Then you can tell your nodes to use this interface, for example:
|
|
|
|
.. code-block:: console
|
|
|
|
export OS_BAREMETAL_API_VERSION=1.31
|
|
for uuid in $(baremetal node list --driver ipmi -f value -c UUID); do
|
|
baremetal node set <node> --inspect-interface inspector
|
|
done
|
|
|
|
.. note::
|
|
A node configured with the IPMI hardware type, will use the inspector
|
|
inspection implementation automatically if it is enabled. This is not
|
|
the case for the most of the vendor drivers.
|
|
|
|
.. _ironic-inspector: https://docs.openstack.org/ironic-inspector/
|
|
|
|
Console
|
|
~~~~~~~
|
|
|
|
Several classic drivers, notably ``pxe_ipmitool_socat`` and
|
|
``agent_ipmitool_socat``, use socat-based serial console implementation.
|
|
|
|
For the ``ipmi`` hardware type it is used by default, if enabled in the
|
|
configuration file:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
enabled_console_interfaces = ipmitool-socat,no-console
|
|
|
|
If you want to use the ``shellinabox`` implementation instead, it has to be
|
|
enabled as well:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
enabled_console_interfaces = ipmitool-shellinabox,no-console
|
|
|
|
Then you need to update some or all nodes to use it explicitly. For example,
|
|
to update all nodes use:
|
|
|
|
.. code-block:: console
|
|
|
|
export OS_BAREMETAL_API_VERSION=1.31
|
|
for uuid in $(baremetal node list --driver ipmi -f value -c UUID); do
|
|
baremetal node set <node> --console-interface ipmitool-shellinabox
|
|
done
|
|
|
|
RAID
|
|
~~~~
|
|
|
|
Many classic drivers, including ``pxe_ipmitool`` and ``agent_ipmitool`` use
|
|
the IPA-based in-band RAID implementation by default.
|
|
|
|
For the hardware types it is not used by default. To use it, you need to
|
|
enable it in the configuration first:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
enabled_raid_interfaces = agent,no-raid
|
|
|
|
Then you can update those nodes that support in-band RAID to use the ``agent``
|
|
RAID interface. For example, to update all nodes use:
|
|
|
|
.. code-block:: console
|
|
|
|
export OS_BAREMETAL_API_VERSION=1.31
|
|
for uuid in $(baremetal node list --driver ipmi -f value -c UUID); do
|
|
baremetal node set <node> --raid-interface agent
|
|
done
|
|
|
|
.. note::
|
|
The ability of a node to use the ``agent`` RAID interface depends on
|
|
the ramdisk (more specifically, a
|
|
:ironic-python-agent-doc:`hardware manager <contributor/hardware_managers.html>`
|
|
used in it), not on the driver.
|
|
|
|
Network and storage
|
|
~~~~~~~~~~~~~~~~~~~
|
|
|
|
The network and storage interfaces have always been dynamic, and thus do not
|
|
require any special treatment during upgrade.
|
|
|
|
Vendor
|
|
~~~~~~
|
|
|
|
Classic drivers are allowed to use the ``VendorMixin`` functionality
|
|
to combine and expose several node or driver vendor passthru methods
|
|
from different vendor interface implementations in one driver.
|
|
|
|
**This is no longer possible with hardware types.**
|
|
|
|
With hardware types, a vendor interface can only have a single active
|
|
implementation from the list of vendor interfaces supported by a given
|
|
hardware type.
|
|
|
|
Ironic no longer has in-tree drivers (both classic and hardware types) that
|
|
rely on this ``VendorMixin`` functionality support.
|
|
However if you are using an out-of-tree classic driver that depends on it,
|
|
you'll need to do the following in order to use vendor
|
|
passthru methods from different vendor passthru implementations:
|
|
|
|
#. While creating a new hardware type to replace your classic driver,
|
|
specify all vendor interface implementations your classic driver
|
|
was using to build its ``VendorMixin`` as supported vendor interfaces
|
|
(property ``supported_vendor_interfaces`` of the Python class
|
|
that defines your hardware type).
|
|
#. Ensure all required vendor interfaces are enabled in the ironic
|
|
configuration file under the ``[DEFAULT]enabled_vendor_interfaces``
|
|
option.
|
|
You should also consider setting the ``[DEFAULT]default_vendor_interface``
|
|
option to specify the vendor interface for nodes that do not have one set
|
|
explicitly.
|
|
#. Before invoking a specific vendor passthru method,
|
|
make sure that the node's vendor interface is set to the interface
|
|
with the desired vendor passthru method.
|
|
For example, if you want to invoke the vendor passthru method
|
|
``vendor_method_foo()`` from ``vendor_foo`` vendor interface:
|
|
|
|
.. code-block:: shell
|
|
|
|
# set the vendor interface to 'vendor_foo`
|
|
baremetal node set <node> --vendor-interface vendor_foo
|
|
|
|
# invoke the vendor passthru method
|
|
baremetal node passthru call <node> vendor_method_foo
|