SNMP driver
|
|
===========
|
|
|
|
The SNMP power driver enables control of power distribution units of the type
|
|
frequently found in data centre racks. PDUs frequently have a management
|
|
ethernet interface and SNMP support enabling control of the power outlets.
|
|
|
|
The SNMP power driver works with the PXE driver for network deployment and
|
|
network-configured boot.
|
|
|
|
List of supported devices
|
|
=========================
|
|
|
|
This is a non-exhaustive list of supported devices. Any device not listed in
|
|
this table could possibly work using a similar driver.
|
|
|
|
Please report any device status.
|
|
|
|
============== ========== ========== =====================
|
|
Manufacturer Model Supported? Driver name
|
|
============== ========== ========== =====================
|
|
APC AP7920 Yes apc_masterswitch
|
|
APC AP9606 Yes apc_masterswitch
|
|
APC AP9225 Yes apc_masterswitchplus
|
|
APC AP7155 Yes apc_rackpdu
|
|
APC AP7900 Yes apc_rackpdu
|
|
APC AP7901 Yes apc_rackpdu
|
|
APC AP7902 Yes apc_rackpdu
|
|
APC AP7911a Yes apc_rackpdu
|
|
APC AP7921 Yes apc_rackpdu
|
|
APC AP7922 Yes apc_rackpdu
|
|
APC AP7930 Yes apc_rackpdu
|
|
APC AP7931 Yes apc_rackpdu
|
|
APC AP7932 Yes apc_rackpdu
|
|
APC AP7940 Yes apc_rackpdu
|
|
APC AP7941 Yes apc_rackpdu
|
|
APC AP7951 Yes apc_rackpdu
|
|
APC AP7960 Yes apc_rackpdu
|
|
APC AP7990 Yes apc_rackpdu
|
|
APC AP7998 Yes apc_rackpdu
|
|
APC AP8941 Yes apc_rackpdu
|
|
APC AP8953 Yes apc_rackpdu
|
|
APC AP8959 Yes apc_rackpdu
|
|
APC AP8961 Yes apc_rackpdu
|
|
APC AP8965 Yes apc_rackpdu
|
|
Aten all? Yes aten
|
|
CyberPower all? Untested cyberpower
|
|
EatonPower all? Untested eatonpower
|
|
Teltronix all? Yes teltronix
|
|
============== ========== ========== =====================
|
|
|
|
|
|
Software Requirements
|
|
=====================
|
|
|
|
- The PySNMP package must be installed, variously referred to as ``pysnmp``
|
|
or ``python-pysnmp``
|
|
|
|
Enabling the SNMP Power Driver
|
|
==============================
|
|
|
|
#. Add ``snmp`` to the list of ``enabled_hardware_types`` in ``ironic.conf``.
|
|
Also update ``enabled_management_interfaces`` and
|
|
``enabled_power_interfaces`` in ``ironic.conf`` as shown below:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
enabled_hardware_types = snmp
|
|
enabled_management_interfaces = fake
|
|
enabled_power_interfaces = snmp
|
|
|
|
#. Alternatively, if you prefer using the classic driver instead of the
|
|
``snmp`` hardware type, add ``pxe_snmp`` to the list of ``enabled_drivers``
|
|
in ``ironic.conf``:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
enabled_drivers = pxe_snmp
|
|
|
|
#. To set the default boot option, update ``default_boot_option`` in
|
|
``ironic.conf``:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
default_boot_option = netboot
|
|
|
|
.. note::
|
|
Currently the default value of ``default_boot_option`` is ``netboot``
|
|
but it will be changed to ``local`` in the future. It is recommended
|
|
to set an explicit value for this option.
|
|
|
|
.. note::
|
|
It is important to set ``boot_option`` to ``netboot`` as SNMP drivers
|
|
do not support setting of boot devices. One can also configure a node
|
|
to boot using ``netboot`` by setting its ``capabilities`` and updating
|
|
Nova flavor as described below:
|
|
|
|
.. code-block:: console
|
|
|
|
openstack baremetal node set --property capabilities="boot_option:netboot" <node-uuid>
|
|
openstack flavor set --property "capabilities:boot_option"="netboot" ironic-flavor
|
|
|
|
|
|
#. Restart the Ironic conductor service.
|
|
|
|
.. code-block:: bash
|
|
|
|
service ironic-conductor restart
|
|
|
|
Ironic Node Configuration
|
|
=========================
|
|
|
|
Nodes configured to use the SNMP driver should have the ``driver`` field
|
|
set to the hardware type ``snmp`` (preferred) or to the classic driver
|
|
``pxe_snmp``.
|
|
|
|
The following property values have to be added to the node's
|
|
``driver_info`` field:
|
|
|
|
- ``snmp_driver``: PDU manufacturer driver
|
|
- ``snmp_address``: the IPv4 address of the PDU controlling this node.
|
|
- ``snmp_port``: (optional) A non-standard UDP port to use for SNMP operations.
|
|
If not specified, the default port (161) is used.
|
|
- ``snmp_outlet``: The power outlet on the PDU (1-based indexing).
|
|
- ``snmp_version``: (optional) SNMP protocol version
|
|
(permitted values ``1``, ``2c`` or ``3``). If not specified, SNMPv1
|
|
is chosen.
|
|
- ``snmp_community``: (Required for SNMPv1 and SNMPv2c) SNMP community
|
|
parameter for reads and writes to the PDU.
|
|
- ``snmp_security``: (Required for SNMPv3) SNMPv3 User-based Security Model
|
|
(USM) user name.
|
|
|
|
The following command can be used to enroll a node with the ``snmp`` driver:
|
|
|
|
.. code-block:: bash
|
|
|
|
openstack baremetal node create --os-baremetal-api-version=1.31 \
|
|
--driver snmp --driver-info snmp_driver=<pdu_manufacturer> \
|
|
--driver-info snmp_address=<ip_address> \
|
|
--driver-info snmp_outlet=<outlet_index> \
|
|
--driver-info snmp_community=<community_string> \
|
|
--properties capabilities=boot_option:netboot
|
|
|
|
PDU Configuration
|
|
=================
|
|
|
|
This version of the SNMP power driver does not support SNMPv3 authentication
|
|
or encryption features. When using SNMPv3, the SNMPv3 agent at the PDU must
|
|
be configured in ``noAuthNoPriv`` mode. Also, the ``snmp_security`` parameter
|
|
is used to configure SNMP USM user name to the SNMP manager at the power
|
|
driver. The same USM user name must be configured to the target SNMP agent.
|