This change makes the admin guide use hardware types for examples and explanations. The in-band inspection document was updated with recent changes. Vendor driver documentation requires more careful review, and ideally should be updated by vendor representatives. Change-Id: I98a2eb905e352502a7f9f4cb1804c9d64489ec47 Partial-Bug: #1690185
332 lines
12 KiB
ReStructuredText
332 lines
12 KiB
ReStructuredText
.. _raid:
|
|
|
|
==================
|
|
RAID Configuration
|
|
==================
|
|
|
|
Overview
|
|
========
|
|
Ironic supports RAID configuration for bare metal nodes. It allows operators
|
|
to specify the desired RAID configuration via the OpenStackClient CLI or REST
|
|
API. The desired RAID configuration is applied on the bare metal during manual
|
|
cleaning.
|
|
|
|
The examples described here use the OpenStackClient CLI; please see the
|
|
`REST API reference <https://developer.openstack.org/api-ref/baremetal/>`_
|
|
for their corresponding REST API requests.
|
|
|
|
Prerequisites
|
|
=============
|
|
The bare metal node needs to use a hardware type that supports RAID
|
|
configuration. RAID interfaces may implement RAID configuration either in-band
|
|
or out-of-band.
|
|
|
|
In-band RAID configuration is done using the Ironic Python Agent
|
|
ramdisk. For in-band RAID configuration using agent ramdisk, a hardware
|
|
manager which supports RAID should be bundled with the ramdisk.
|
|
Whether a node supports RAID configuration could be found using the CLI
|
|
command ``openstack baremetal node validate <node-uuid>``.
|
|
|
|
Build agent ramdisk which supports RAID configuration
|
|
=====================================================
|
|
|
|
For doing in-band RAID configuration, Ironic needs an agent ramdisk bundled
|
|
with a hardware manager which supports RAID configuration for your hardware.
|
|
For example, the :ref:`DIB_raid_support` should be used for HPE
|
|
Proliant Servers.
|
|
|
|
RAID configuration JSON format
|
|
==============================
|
|
The desired RAID configuration and current RAID configuration are represented
|
|
in JSON format.
|
|
|
|
Target RAID configuration
|
|
-------------------------
|
|
This is the desired RAID configuration on the bare metal node. Using the
|
|
OpenStackClient CLI (or REST API), the operator sets ``target_raid_config``
|
|
field of the node. The target RAID configuration will be applied during manual
|
|
cleaning.
|
|
|
|
Target RAID configuration is a dictionary having ``logical_disks``
|
|
as the key. The value for the ``logical_disks`` is a list of JSON
|
|
dictionaries. It looks like::
|
|
|
|
{
|
|
"logical_disks": [
|
|
{<desired properties of logical disk 1>},
|
|
{<desired properties of logical disk 2>},
|
|
.
|
|
.
|
|
.
|
|
]
|
|
}
|
|
|
|
If the ``target_raid_config`` is an empty dictionary, it unsets the value of
|
|
``target_raid_config`` if the value was set with previous RAID configuration
|
|
done on the node.
|
|
|
|
Each dictionary of logical disk contains the desired properties of logical
|
|
disk supported by the hardware type or classic driver. These properties are
|
|
discoverable by::
|
|
|
|
openstack baremetal --os-baremetal-api-version 1.15 driver raid property list <driver name>
|
|
|
|
The RAID feature is available in ironic API version 1.15 and above.
|
|
If ``--os-baremetal-api-version`` is not used in the CLI, it will error out
|
|
with the following message::
|
|
|
|
No API version was specified and the requested operation was not
|
|
supported by the client's negotiated API version 1.9. Supported
|
|
version range is: 1.1 to ...
|
|
|
|
where the "..." in above error message would be the maximum version
|
|
supported by the service.
|
|
|
|
The RAID properties can be split into 4 different types:
|
|
|
|
#. Mandatory properties. These properties must be specified for each logical
|
|
disk and have no default values.
|
|
|
|
- ``size_gb`` - Size (Integer) of the logical disk to be created in GiB.
|
|
``MAX`` may be specified if the logical disk should use all of the
|
|
remaining space available. This can be used only when backing physical
|
|
disks are specified (see below).
|
|
|
|
- ``raid_level`` - RAID level for the logical disk. Ironic supports the
|
|
following RAID levels: 0, 1, 2, 5, 6, 1+0, 5+0, 6+0.
|
|
|
|
#. Optional properties. These properties have default values and
|
|
they may be overridden in the specification of any logical disk.
|
|
|
|
- ``volume_name`` - Name of the volume. Should be unique within the Node.
|
|
If not specified, volume name will be auto-generated.
|
|
|
|
- ``is_root_volume`` - Set to ``true`` if this is the root volume. At
|
|
most one logical disk can have this set to ``true``; the other
|
|
logical disks must have this set to ``false``. The
|
|
``root device hint`` will be saved, if the RAID interface is capable of
|
|
retrieving it. This is ``false`` by default.
|
|
|
|
#. Backing physical disk hints. These hints are specified for each logical
|
|
disk to let Ironic find the desired disks for RAID configuration. This is
|
|
machine-independent information. This serves the use-case where the
|
|
operator doesn't want to provide individual details for each bare metal
|
|
node.
|
|
|
|
- ``share_physical_disks`` - Set to ``true`` if this logical disk can
|
|
share physical disks with other logical disks. The default value is
|
|
``false``.
|
|
|
|
- ``disk_type`` - ``hdd`` or ``ssd``. If this is not specified, disk type
|
|
will not be a criterion to find backing physical disks.
|
|
|
|
- ``interface_type`` - ``sata`` or ``scsi`` or ``sas``. If this is not
|
|
specified, interface type will not be a criterion to
|
|
find backing physical disks.
|
|
|
|
- ``number_of_physical_disks`` - Integer, number of disks to use for the
|
|
logical disk. Defaults to minimum number of disks required for the
|
|
particular RAID level.
|
|
|
|
#. Backing physical disks. These are the actual machine-dependent
|
|
information. This is suitable for environments where the operator wants
|
|
to automate the selection of physical disks with a 3rd-party tool based
|
|
on a wider range of attributes (eg. S.M.A.R.T. status, physical location).
|
|
The values for these properties are hardware dependent.
|
|
|
|
- ``controller`` - The name of the controller as read by the RAID interface.
|
|
- ``physical_disks`` - A list of physical disks to use as read by the
|
|
RAID interface.
|
|
|
|
.. note::
|
|
If properties from both "Backing physical disk hints" or
|
|
"Backing physical disks" are specified, they should be consistent with
|
|
each other. If they are not consistent, then the RAID configuration
|
|
will fail (because the appropriate backing physical disks could
|
|
not be found).
|
|
|
|
Examples for ``target_raid_config``
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
*Example 1*. Single RAID disk of RAID level 5 with all of the space
|
|
available. Make this the root volume to which Ironic deploys the image::
|
|
|
|
{
|
|
"logical_disks": [
|
|
{
|
|
"size_gb": "MAX",
|
|
"raid_level": "5",
|
|
"is_root_volume": true
|
|
}
|
|
]
|
|
}
|
|
|
|
*Example 2*. Two RAID disks. One with RAID level 5 of 100 GiB and make it
|
|
root volume and use SSD. Another with RAID level 1 of 500 GiB and use
|
|
HDD::
|
|
|
|
{
|
|
"logical_disks": [
|
|
{
|
|
"size_gb": 100,
|
|
"raid_level": "5",
|
|
"is_root_volume": true,
|
|
"disk_type": "ssd"
|
|
},
|
|
{
|
|
"size_gb": 500,
|
|
"raid_level": "1",
|
|
"disk_type": "hdd"
|
|
}
|
|
]
|
|
}
|
|
|
|
*Example 3*. Single RAID disk. I know which disks and controller to use::
|
|
|
|
{
|
|
"logical_disks": [
|
|
{
|
|
"size_gb": 100,
|
|
"raid_level": "5",
|
|
"controller": "Smart Array P822 in Slot 3",
|
|
"physical_disks": ["6I:1:5", "6I:1:6", "6I:1:7"],
|
|
"is_root_volume": true
|
|
}
|
|
]
|
|
}
|
|
|
|
*Example 4*. Using backing physical disks::
|
|
|
|
{
|
|
"logical_disks":
|
|
[
|
|
{
|
|
"size_gb": 50,
|
|
"raid_level": "1+0",
|
|
"controller": "RAID.Integrated.1-1",
|
|
"volume_name": "root_volume",
|
|
"is_root_volume": true,
|
|
"physical_disks": [
|
|
"Disk.Bay.0:Encl.Int.0-1:RAID.Integrated.1-1",
|
|
"Disk.Bay.1:Encl.Int.0-1:RAID.Integrated.1-1"
|
|
]
|
|
},
|
|
{
|
|
"size_gb": 100,
|
|
"raid_level": "5",
|
|
"controller": "RAID.Integrated.1-1",
|
|
"volume_name": "data_volume",
|
|
"physical_disks": [
|
|
"Disk.Bay.2:Encl.Int.0-1:RAID.Integrated.1-1",
|
|
"Disk.Bay.3:Encl.Int.0-1:RAID.Integrated.1-1",
|
|
"Disk.Bay.4:Encl.Int.0-1:RAID.Integrated.1-1"
|
|
]
|
|
}
|
|
]
|
|
}
|
|
|
|
|
|
Current RAID configuration
|
|
--------------------------
|
|
After target RAID configuration is applied on the bare metal node, Ironic
|
|
populates the current RAID configuration. This is populated in the
|
|
``raid_config`` field in the Ironic node. This contains the details about
|
|
every logical disk after they were created on the bare metal node. It
|
|
contains details like RAID controller used, the backing physical disks used,
|
|
WWN of each logical disk, etc. It also contains information about each
|
|
physical disk found on the bare metal node.
|
|
|
|
To get the current RAID configuration::
|
|
|
|
openstack baremetal --os-baremetal-api-version 1.15 node show <node-uuid-or-name>
|
|
|
|
Workflow
|
|
========
|
|
|
|
* Operator configures the bare metal node with a hardware type that has
|
|
a ``RAIDInterface`` other than ``no-raid`` (``None`` for classic drivers).
|
|
|
|
* For in-band RAID configuration, operator builds an agent ramdisk which
|
|
supports RAID configuration by bundling the hardware manager with the
|
|
ramdisk. See `Build agent ramdisk which supports RAID configuration`_ for
|
|
more information.
|
|
|
|
* Operator prepares the desired target RAID configuration as mentioned in
|
|
`Target RAID configuration`_. The target RAID configuration is set on
|
|
the Ironic node::
|
|
|
|
openstack baremetal --os-baremetal-api-version 1.15 node set <node-uuid-or-name> \
|
|
--target-raid-config <JSON file containing target RAID configuration>
|
|
|
|
The CLI command can accept the input from standard input also:
|
|
openstack baremetal --os-baremetal-api-version 1.15 node set <node-uuid-or-name> \
|
|
--target-raid-config -
|
|
|
|
* Create a JSON file with the RAID clean steps for manual cleaning. Add other
|
|
clean steps as desired::
|
|
|
|
|
|
[{
|
|
"interface": "raid",
|
|
"step": "delete_configuration"
|
|
},
|
|
{
|
|
"interface": "raid",
|
|
"step": "create_configuration"
|
|
}]
|
|
|
|
.. note::
|
|
'create_configuration' doesn't remove existing disks. It is recommended
|
|
to add 'delete_configuration' before 'create_configuration' to make
|
|
sure that only the desired logical disks exist in the system after
|
|
manual cleaning.
|
|
|
|
* Bring the node to ``manageable`` state and do a ``clean`` action to start
|
|
cleaning on the node::
|
|
|
|
openstack baremetal --os-baremetal-api-version 1.15 node clean <node-uuid-or-name> \
|
|
--clean-steps <JSON file containing clean steps created above>
|
|
|
|
* After manual cleaning is complete, the current RAID configuration can be
|
|
viewed using::
|
|
|
|
openstack baremetal --os-baremetal-api-version 1.15 node show <node-uuid-or-name>
|
|
|
|
Using RAID in nova flavor for scheduling
|
|
========================================
|
|
|
|
The operator can specify the `raid_level` capability in nova flavor for node to be selected
|
|
for scheduling::
|
|
|
|
nova flavor-key my-baremetal-flavor set capabilities:raid_level="1+0"
|
|
|
|
Developer documentation
|
|
=======================
|
|
In-band RAID configuration is done using IPA ramdisk. IPA ramdisk has
|
|
support for pluggable hardware managers which can be used to extend the
|
|
functionality offered by IPA ramdisk using stevedore plugins. For more
|
|
information, see Ironic Python Agent `Hardware Manager`_ documentation.
|
|
|
|
.. _`Hardware Manager`: https://docs.openstack.org/ironic-python-agent/latest/install/index.html#hardware-managers
|
|
|
|
The hardware manager that supports RAID configuration should do the following:
|
|
|
|
#. Implement a method named ``create_configuration``. This method creates
|
|
the RAID configuration as given in ``target_raid_config``. After successful
|
|
RAID configuration, it returns the current RAID configuration information
|
|
which ironic uses to set ``node.raid_config``.
|
|
|
|
#. Implement a method named ``delete_configuration``. This method deletes
|
|
all the RAID disks on the bare metal.
|
|
|
|
#. Return these two clean steps in ``get_clean_steps`` method with priority
|
|
as 0. Example::
|
|
|
|
return [{'step': 'create_configuration',
|
|
'interface': 'raid',
|
|
'priority': 0},
|
|
{'step': 'delete_configuration',
|
|
'interface': 'raid',
|
|
'priority': 0}]
|
|
|